ASTM D6005-03(2008)
(Test Method)Standard Test Method for Determining Slump Resistance of Carpet Adhesives
Standard Test Method for Determining Slump Resistance of Carpet Adhesives
SIGNIFICANCE AND USE
During application, end users typically remove the adhesive from the container using the trowel and spread it onto the desired substrate. Adhesives with good rheological characteristics, therefore, will allow trowel retention. Adhesives with poor rheological characteristics tend to be unacceptable because they cannot be picked up by a trowel.
Bead configuration is important in order to provide proper wetting/contact of the carpet backing. Beads drawn with a trowel, which show a nonslumping ridge, are preferred because they allow good contact to both substrates.
Measurement of the slump resistance of the adhesive will allow an end user to know if an adhesive is capable of both adhering well to the trowel during application and maintain a nonflowing adhesive ridge.
SCOPE
1.1 This test method describes a procedure to measure slump, or sag, resistance of a trowel-grade carpet adhesive using a button slump test apparatus.
1.2 This test method provides a visual evaluation to relate troweled bead profile and trowel pickup.
1.3 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Buy Standard
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:D6005–03(Reapproved2008)
Standard Test Method for
Determining Slump Resistance of Carpet Adhesives
This standard is issued under the fixed designation D6005; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope poor rheological characteristics tend to be unacceptable be-
cause they cannot be picked up by a trowel.
1.1 This test method describes a procedure to measure
4.2 Bead configuration is important in order to provide
slump, or sag, resistance of a trowel-grade carpet adhesive
properwetting/contactofthecarpetbacking.Beadsdrawnwith
using a button slump test apparatus.
a trowel, which show a nonslumping ridge, are preferred
1.2 This test method provides a visual evaluation to relate
because they allow good contact to both substrates.
troweled bead profile and trowel pickup.
4.3 Measurement of the slump resistance of the adhesive
1.3 The values stated in inch-pound units are to be regarded
will allow an end user to know if an adhesive is capable of both
as the standard. The values given in parentheses are for
adhering well to the trowel during application and maintain a
information only.
nonflowing adhesive ridge.
1.4 This standard does not purport to address all of the
safety concerns, if any, associated with its use. It is the
5. Apparatus
responsibility of the user of this standard to establish appro-
5.1 Slump Test Jig, constructed in accordance with Test
priate safety and health practices and determine the applica-
Method D2202.
bility of regulatory limitations prior to use.
5.2 Gravity Convection Oven, having a temperature con-
2. Referenced Documents trolled at 122 6 3.6°F (50 6 2°C).
5.3 Steel Spatula.
2.1 ASTM Standards:
D618 Practice for Conditioning Plastics for Testing
6. Materials
D907 Terminology of Adhesives
6.1 Adhesive—Any appropriate adhesive used to install
D2202 Test Method for Slump of Sealants
floorcovering.
3. Terminology 6.2 Solvent—Any appropriate reagent.
3.1 Definitions—Many of the terms in this test method are
7. Conditioning
defined in Terminology D907.
7.1 Condition the slump jig and adhesive to be tested 24 h
4. Significance and Use at 73.4 6 3.6°F (23 6 2°C) and 50 % 6 5 % relative humidity
prior to testing.
4.1 During application, end users typically remove the
adhesive from the container using the trowel and spread it onto
8. Procedure
the desired substrate.Adhesives with good rheological charac-
8.1 Place the slump jig on a level table with the front face
teristics, therefore, will allow trowel retention.Adhesives with
upward and the plunger depressed to the limit of its travel.
8.2 Apply the adhesive into the cavity of the slump jig. Use
This test method is under the jurisdiction of ASTM Committee D14
...
This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation:D6005–96 Designation: D 6005 – 03 (Reapproved 2008)
Standard Test Method for
Determining Slump Resistance of Carpet Adhesives
This standard is issued under the fixed designation D 6005; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 This test method describes a procedure to measure slump, or sag, resistance of a trowel-grade carpet adhesive using a button
slump test apparatus.
1.2 This test method provides a visual evaluation to relate troweled bead profile and trowel pickup.
1.3 The values stated in inch-pound units are to be regarded as the standard.The values given in parentheses are for information
only.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory
limitations prior to use.
2. Referenced Documents
2.1 ASTM Standards:
D 618 Practice for Conditioning Plastics for Testing
D 907 Terminology of Adhesives
D 2202 Test Method for Slump of Sealants
3. Terminology
3.1 Definitions—Many of the terms in this test method are defined in Terminology D 907.
4. Significance and Use
4.1 During application, end users typically remove the adhesive from the container using the trowel and spread it onto the
desired substrate. Adhesives with good rheological characteristics, therefore, will allow trowel retention. Adhesives with poor
rheological characteristics tend to be unacceptable because they cannot be picked up by a trowel.
4.2 Bead configuration is important in order to provide proper wetting/contact of the carpet backing. Beads drawn with a trowel,
which show a nonslumping ridge, are preferred because they allow good contact to both substrates.
4.3 Measurement of the slump resistance of the adhesive will allow an end user to know if an adhesive is capable of both
adhering well to the trowel during application and maintain a nonflowing adhesive ridge.
5. Apparatus
5.1 Slump Test Jig, constructed in accordance with Test Method D 2202.
5.2 Gravity Convection Oven, having a temperature controlled at 122 6 3.6°F (50 6 2°C).
5.3 Steel Spatula.
6. Materials
6.1 Adhesive—Any appropriate adhesive used to install floorcovering.
6.2 Solvent—Any appropriate reagent.
7. Conditioning
7.1 Condition the slump jig and adhesive to be tested 24 h at 73.4 6 3.6°F (23 6 2°C) and 50 % 6 5 % relative humidity prior
to testing.
This test method is under the jurisdiction ofASTM Committee D-14 onAdhesives and is the direct responsibility of Subcommittee D14.70 on ConstructionAdhesives.
Current edition approved Sept. 10, 1996. Published November 1996.
This test method is under the jurisdiction of
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.