ASTM C56-04
(Specification)Standard Specification for Structural Clay Non-Load-Bearing Tile
Standard Specification for Structural Clay Non-Load-Bearing Tile
SCOPE
1.1 This specification covers structural clay non-load-bearing tile (partition, fireproofing, and furring). One grade of tile is covered, designated Grade NB.
1.2 The property requirements of this standard apply at the time of purchase. The use of results from testing of tile extracted from masonry structures for determining conformance or non-conformance to the property requirements (Section 3) of this standard is beyond the scope of this standard.
1.3 Tile covered by this standard are manufactured from clay, shale, or similar naturally occurring substances and subjected to a heat treatment at elevated temperatures (firing). The heat treatment must develop sufficient fired bond between the particulate constituents to provide the strength and durability requirements of this specification. (See firing and fired bond in Terminology C 43.)
1.4 Fireproofing tile intended for use in load-bearing masonry shall conform to Specification C 34.
1.5 If tile having a particular color (Note 1), texture, or finish are desired, these features shall be specified separately by the purchaser.
Note 1—Color of tile varies with the type of clay used and degree of burning; hence, it cannot be taken as indicative of classification until after it has been related to absorption by actual tests.
1.6 The text of this specification references notes and footnotes that provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of this specification.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn. Contact ASTM
International (www.astm.org) for the latest information.
Designation: C 56 – 04
Standard Specification for
1
Structural Clay Non-Load-Bearing Tile
ThisstandardisissuedunderthefixeddesignationC 56;thenumberimmediatelyfollowingthedesignationindicatestheyearoforiginal
adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.Asuperscript
epsilon (e) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope C34 Specification for Structural Clay Load-Bearing Wall
Tile
1.1 This specification covers structural clay non-load-
C43 Terminology of Structural Clay Products
bearing tile (partition, fireproofing, and furring). One grade of
C67 Test Methods of Sampling and Testing Brick and
tile is covered, designated Grade NB.
Structural Clay Tile
1.2 The property requirements of this standard apply at the
time of purchase. The use of results from testing of tile
3. Absorption
extracted from masonry structures for determining conform-
3.1 Structural clay non-load-bearing tile shall conform to
anceornon-conformancetothepropertyrequirements(Section
the following requirements for absorption:
3) of this standard is beyond the scope of this standard.
A
Absorption by 1-h Boiling, %
1.3 Tile covered by this standard are manufactured from
Grade
clay, shale, or similar naturally occurring substances and
Individual Maximum
subjected to a heat treatment at elevated temperatures (firing). NB 28
The heat treatment must develop sufficient fired bond between
the particulate constituents to provide the strength and dura-
A
Therangeinpercentageabsorptionfortiledeliveredtoanyonejobshallbenot
bility requirements of this specification. (See firing and fired
more than 12.
bond in TerminologyC43.)
1.4 Fireproofing tile intended for use in load-bearing ma-
4. Number of Cells and Weights
sonry shall conform to SpecificationC34.
4.1 Partition and split furring tile shall conform to the
1.5 If tile having a particular color (Note 1), texture, or
requirements prescribed in Table 1 for total number of cells,
finish are desired, these features shall be specified separately
number of cells in the direction of wall thickness, and dry
by the purchaser.
weights per square foot of tile.
NOTE 1—Color of tile varies with the type of clay used and degree of
4.2 The requirements for minimum weights of structural
burning; hence, it cannot be taken as indicative of classification until after
clay non-load-bearing tile shall be waived if the over-all
it has been related to absorption by actual tests.
thickness of the shells, measured between the inner and
5
1.6 The text of this specification references notes and extreme outer surfaces of scored tile, is not less than ⁄8 in.
footnotes that provide explanatory material. These notes and
(15.9 mm) and the mean shell thickness of unscored tile is not
1
footnotes (excluding those in tables and figures) shall not be less than ⁄2 in. (12.7 mm). Thickness of webs shall be not less
1
considered as requirements of this specification.
than ⁄2 in.
2. Referenced Documents 5. Dimensions and Permissible Variations
2
2.1 ASTM Standards:
5.1 No over-all dimension shall vary more than 3 % over or
under the specified dimension for any form or size of tile. See
Note 2.
1
This specification is under the jurisdiction of ASTM Committee C15 on
NOTE 2—Purchasers and designers should ascertain the type and size of
Manufactured Masonry Units and is the direct responsibility of Subcommittee
tile, modular or non-modular, available in the locality under consideration
C15.02 on Brick and Structural Clay Tile.
and should specify accordingly, stating the size and type represented by
Current edition approved Dec. 1, 2004. Published January 2005. Originally
the available tile.
approved in 1924. Last previous edition approved in 2001 as C 56 – 96 (2001).
2 Modular sizes are designated by the specified nominal dimensions
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
which are equal to the actual manufactured dimensions plus the thickness
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
1
of one mortar joint, not to exceed ⁄2 in. (12.7 mm) (see Section 6.) For
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website. example, if the modular, specified, or nominal dimensions of a unit are 4
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn. Contact ASTM
International (www.astm.org) for the latest information.
C56–04
TABLE 1 Number of Cells and Weight of Tile
A 2 2
Minimum Number of Cells Minimum
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.