Standard Test Methods for Determining the Izod Pendulum Impact Resistance of Plastics

SIGNIFICANCE AND USE
5.1 Before proceeding with these test methods, reference should be made to the specification of the material being tested. Any test specimen preparation, conditioning, dimensions, and testing parameters covered in the materials specification shall take precedence over those mentioned in these test methods. If there is no material specification, then the default conditions apply.  
5.2 The pendulum impact test indicates the energy to break standard test specimens of specified size under stipulated parameters of specimen mounting, notching, and pendulum velocity-at-impact.  
5.3 The energy lost by the pendulum during the breakage of the specimen is the sum of the following:  
5.3.1 Energy to initiate fracture of the specimen;  
5.3.2 Energy to propagate the fracture across the specimen;  
5.3.3 Energy to throw the free end (or ends) of the broken specimen (“toss correction”);  
5.3.4 Energy to bend the specimen;  
5.3.5 Energy to produce vibration in the pendulum arm;  
5.3.6 Energy to produce vibration or horizontal movement of the machine frame or base;  
5.3.7 Energy to overcome friction in the pendulum bearing and in the indicating mechanism, and to overcome windage (pendulum air drag);  
5.3.8 Energy to indent or deform plastically the specimen at the line of impact; and  
5.3.9 Energy to overcome the friction caused by the rubbing of the striker (or other part of the pendulum) over the face of the bent specimen.  
5.4 For relatively brittle materials, for which fracture propagation energy is small in comparison with the fracture initiation energy, the indicated impact energy absorbed is, for all practical purposes, the sum of factors 5.3.1 and 5.3.3. The toss correction (see 5.3.3) may represent a very large fraction of the total energy absorbed when testing relatively dense and brittle materials. Test Method C shall be used for materials that have an Izod impact resistance of less than 27 J/m (0.5 ft·lbf/in.). (See Appendix X4 for optional units.) T...
SCOPE
1.1 These test methods cover the determination of the resistance of plastics to “standardized” (see Note 1) pendulum-type hammers, mounted in “standardized” machines, in breaking standard specimens with one pendulum swing (see Note 2). The standard tests for these test methods require specimens made with a milled notch (see Note 3). In Test Methods A, C, and D, the notch produces a stress concentration that increases the probability of a brittle, rather than a ductile, fracture. In Test Method E, the impact resistance is obtained by reversing the notched specimen 180° in the clamping vise. The results of all test methods are reported in terms of energy absorbed per unit of specimen width or per unit of cross-sectional area under the notch. (See Note 4.)
Note 1: The machines with their pendulum-type hammers have been “standardized” in that they must comply with certain requirements, including a fixed height of hammer fall that results in a substantially fixed velocity of the hammer at the moment of impact. However, hammers of different initial energies (produced by varying their effective weights) are recommended for use with specimens of different impact resistance. Moreover, manufacturers of the equipment are permitted to use different lengths and constructions of pendulums with possible differences in pendulum rigidities resulting. (See Section 5.) Be aware that other differences in machine design may exist. The specimens are “standardized” in that they are required to have one fixed length, one fixed depth, and one particular design of milled notch. The width of the specimens is permitted to vary between limits.
Note 2: Results generated using pendulums that utilize a load cell to record the impact force and thus impact energy, may not be equivalent to results that are generated using manually or digitally encoded testers that measure the energy remaining in the pendulum after impact.
Note 3: The notch in the Iz...

General Information

Status
Historical
Publication Date
14-Mar-2023
Technical Committee
Current Stage
Ref Project

Buy Standard

Standard
ASTM D256-23 - Standard Test Methods for Determining the Izod Pendulum Impact Resistance of Plastics
English language
20 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
REDLINE ASTM D256-23 - Standard Test Methods for Determining the Izod Pendulum Impact Resistance of Plastics
English language
20 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: D256 − 23
Standard Test Methods for
Determining the Izod Pendulum Impact Resistance of
1
Plastics
This standard is issued under the fixed designation D256; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the U.S. Department of Defense.
NOTE 4—Caution must be exercised in interpreting the results of these
1. Scope
standard test methods. The following testing parameters may affect test
1.1 These test methods cover the determination of the
results significantly:
resistance of plastics to “standardized” (see Note 1) pendulum-
Method of fabrication, including but not limited to processing
type hammers, mounted in “standardized” machines, in break- technology, molding conditions, mold design, and thermal
treatments;
ing standard specimens with one pendulum swing (see Note 2).
Method of notching;
The standard tests for these test methods require specimens
Speed of notching tool;
made with a milled notch (see Note 3). In Test Methods A, C,
Design of notching apparatus;
Quality of the notch;
and D, the notch produces a stress concentration that increases
Time between notching and test;
the probability of a brittle, rather than a ductile, fracture. In
Test specimen thickness,
Test Method E, the impact resistance is obtained by reversing Test specimen width under notch, and
Environmental conditioning.
the notched specimen 180° in the clamping vise. The results of
1.2 The values stated in SI units are to be regarded as
all test methods are reported in terms of energy absorbed per
unit of specimen width or per unit of cross-sectional area under standard. The values given in parentheses are for information
only.
the notch. (See Note 4.)
1.3 This standard does not purport to address all of the
NOTE 1—The machines with their pendulum-type hammers have been
safety concerns, if any, associated with its use. It is the
“standardized” in that they must comply with certain requirements,
including a fixed height of hammer fall that results in a substantially fixed
responsibility of the user of this standard to establish appro-
velocity of the hammer at the moment of impact. However, hammers of
priate safety, health, and environmental practices and deter-
different initial energies (produced by varying their effective weights) are
mine the applicability of regulatory limitations prior to use.
recommended for use with specimens of different impact resistance.
Moreover, manufacturers of the equipment are permitted to use different
NOTE 5—These test methods resemble ISO 180:1993 in regard to title
lengths and constructions of pendulums with possible differences in
only. The contents are significantly different.
pendulum rigidities resulting. (See Section 5.) Be aware that other
1.4 This international standard was developed in accor-
differences in machine design may exist. The specimens are “standard-
dance with internationally recognized principles on standard-
ized” in that they are required to have one fixed length, one fixed depth,
and one particular design of milled notch. The width of the specimens is
ization established in the Decision on Principles for the
permitted to vary between limits.
Development of International Standards, Guides and Recom-
NOTE 2—Results generated using pendulums that utilize a load cell to
mendations issued by the World Trade Organization Technical
record the impact force and thus impact energy, may not be equivalent to
Barriers to Trade (TBT) Committee.
results that are generated using manually or digitally encoded testers that
measure the energy remaining in the pendulum after impact.
2. Referenced Documents
NOTE 3—The notch in the Izod specimen serves to concentrate the
stress, minimize plastic deformation, and direct the fracture to the part of 2
2.1 ASTM Standards:
the specimen behind the notch. Scatter in energy-to-break is thus reduced.
D618 Practice for Conditioning Plastics for Testing
However, because of differences in the elastic and viscoelastic properties
D883 Terminology Relating to Plastics
of plastics, response to a given notch varies among materials. A measure
of a plastic’s “notch sensitivity” may be obtained with Test Method D by D3641 Practice for Injection Molding Test Specimens of
comparing the energies to break specimens having different radii at the
Thermoplastic Molding and Extrusion Materials
base of the notch.
D4066 Classification System for Nylon Injection and Extru-
sion Materials (PA)
1
These test methods are under the jurisdiction of ASTM Committee D20 on
Plastics and are the direct responsibil
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: D256 − 10 (Reapproved 2018) D256 − 23
Standard Test Methods for
Determining the Izod Pendulum Impact Resistance of
1
Plastics
This standard is issued under the fixed designation D256; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the U.S. Department of Defense.
1. Scope
1.1 These test methods cover the determination of the resistance of plastics to “standardized” (see Note 1) pendulum-type
hammers, mounted in “standardized” machines, in breaking standard specimens with one pendulum swing (see Note 2). The
standard tests for these test methods require specimens made with a milled notch (see Note 3). In Test Methods A, C, and D, the
notch produces a stress concentration that increases the probability of a brittle, rather than a ductile, fracture. In Test Method E,
the impact resistance is obtained by reversing the notched specimen 180° in the clamping vise. The results of all test methods are
reported in terms of energy absorbed per unit of specimen width or per unit of cross-sectional area under the notch. (See Note 4.)
NOTE 1—The machines with their pendulum-type hammers have been “standardized” in that they must comply with certain requirements, including a
fixed height of hammer fall that results in a substantially fixed velocity of the hammer at the moment of impact. However, hammers of different initial
energies (produced by varying their effective weights) are recommended for use with specimens of different impact resistance. Moreover, manufacturers
of the equipment are permitted to use different lengths and constructions of pendulums with possible differences in pendulum rigidities resulting. (See
Section 5.) Be aware that other differences in machine design may exist. The specimens are “standardized” in that they are required to have one fixed
length, one fixed depth, and one particular design of milled notch. The width of the specimens is permitted to vary between limits.
NOTE 2—Results generated using pendulums that utilize a load cell to record the impact force and thus impact energy, may not be equivalent to results
that are generated using manually or digitally encoded testers that measure the energy remaining in the pendulum after impact.
NOTE 3—The notch in the Izod specimen serves to concentrate the stress, minimize plastic deformation, and direct the fracture to the part of the specimen
behind the notch. Scatter in energy-to-break is thus reduced. However, because of differences in the elastic and viscoelastic properties of plastics, response
to a given notch varies among materials. A measure of a plastic’s “notch sensitivity” may be obtained with Test Method D by comparing the energies
to break specimens having different radii at the base of the notch.
NOTE 4—Caution must be exercised in interpreting the results of these standard test methods. The following testing parameters may affect test results
significantly:
Method of fabrication, including but not limited to processing
technology, molding conditions, mold design, and thermal
treatments;
Method of notching;
Speed of notching tool;
Design of notching apparatus;
Quality of the notch;
Time between notching and test;
Test specimen thickness,
Test specimen width under notch, and
Environmental conditioning.
1
These test methods are under the jurisdiction of ASTM Committee D20 on Plastics and are the direct responsibility of Subcommittee D20.10 on Mechanical Properties.
Current edition approved Nov. 1, 2018March 15, 2023. Published November 2018March 2023. Originally approved in 1926. Last previous edition approved in 20102018
ɛ1
as D256 -10 -10(2018). . DOI: 10.1520/D0256-10R18.10.1520/D0256-23.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
D256 − 23
1.2 The values stated in SI units are to be regarded as standard. The values given in parentheses are for information only.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety, health, and environmental practices and
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.