ASTM C1611/C1611M-18
(Test Method)Standard Test Method for Slump Flow of Self-Consolidating Concrete
Standard Test Method for Slump Flow of Self-Consolidating Concrete
SIGNIFICANCE AND USE
5.1 This test method provides a procedure to determine the slump flow of self-consolidating concrete in the laboratory or the field.
5.2 This test method is used to monitor the consistency of fresh, unhardened self-consolidating concrete and its unconfined flow potential.
5.3 It is difficult to produce self-consolidating concrete that is both flowable and nonsegregating using coarse aggregates larger than 25 mm [1 in.]. Therefore, this test method is considered applicable to self-consolidating concrete having coarse aggregate up to 25 mm [1 in.] in size. Appendix X1 provides non-mandatory visual rating criteria that may be used to classify the ability of a self-consolidating concrete mixture to resist segregation (stability).
5.4 The rate at which the concrete spreads is related to its viscosity. Appendix X1 provides a non-mandatory procedure that may be used to provide an indication of relative viscosity of self-consolidating concrete mixtures.
SCOPE
1.1 This test method covers the determination of slump flow of self-consolidating concrete (SCC).
1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.
1.3 The text of this standard references notes and footnotes that provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard. (Warning—Fresh hydraulic cementitious mixtures are caustic and may cause chemical burns to skin and tissue upon prolonged exposure.2)
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. (Warning—Fresh hydraulic cementitious mixtures are caustic and may cause chemical burns to skin and tissue upon prolonged exposure.3)
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
General Information
Buy Standard
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: C1611/C1611M − 18
Standard Test Method for
1
Slump Flow of Self-Consolidating Concrete
ThisstandardisissuedunderthefixeddesignationC1611/C1611M;thenumberimmediatelyfollowingthedesignationindicatestheyear
of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.
A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope* 2. Referenced Documents
4
1.1 This test method covers the determination of slump flow 2.1 ASTM Standards:
of self-consolidating concrete (SCC). C125 Terminology Relating to Concrete and Concrete Ag-
gregates
1.2 The values stated in either SI units or inch-pound units
C143/C143M Test Method for Slump of Hydraulic-Cement
are to be regarded separately as standard. The values stated in
Concrete
each system may not be exact equivalents; therefore, each
C172 Practice for Sampling Freshly Mixed Concrete
system shall be used independently of the other. Combining
C173/C173M Test Method forAir Content of Freshly Mixed
values from the two systems may result in non-conformance
Concrete by the Volumetric Method
with the standard.
C670 Practice for Preparing Precision and Bias Statements
1.3 The text of this standard references notes and footnotes
for Test Methods for Construction Materials
that provide explanatory material. These notes and footnotes
C1758/C1758M Practice for Fabricating Test Specimens
(excluding those in tables and figures) shall not be considered
with Self-Consolidating Concrete
as requirements of the standard. (Warning—Fresh hydraulic
cementitious mixtures are caustic and may cause chemical
3. Terminology
2
burns to skin and tissue upon prolonged exposure. )
3.1 For definitions of terms used in this test method, refer to
1.4 This standard does not purport to address all of the
Terminology C125.
safety concerns, if any, associated with its use. It is the
3.2 Definitions of Terms Specific to This Standard:
responsibility of the user of this standard to establish appro-
3.2.1 halo, n—an observed cement paste or mortar ring that
priate safety, health, and environmental practices and deter-
has clearly separated from the coarse aggregate, around the
mine the applicability of regulatory limitations prior to use.
outside circumference of concrete after flowing from the mold.
(Warning—Fresh hydraulic cementitious mixtures are caustic
3.2.2 spread, n—the distance of lateral flow of concrete
and may cause chemical burns to skin and tissue upon
3
during the slump-flow test.
prolonged exposure. )
1.5 This international standard was developed in accor- 3.2.3 stability, n—the ability of a concrete mixture to resist
dance with internationally recognized principles on standard- segregation of the paste from the aggregates.
ization established in the Decision on Principles for the
3.2.4 viscosity, n—resistance of a material to flow under an
Development of International Standards, Guides and Recom-
applied shearing stress.
mendations issued by the World Trade Organization Technical
Barriers to Trade (TBT) Committee. 4. Summary of Test Method
4.1 A sample of freshly mixed concrete is placed in a mold
1
This test method is under the jurisdiction of ASTM Committee C09 on
eitherintheuprightorinvertedposition.Theconcreteisplaced
Concrete and ConcreteAggregates and is the direct responsibility of Subcommittee
inoneliftwithouttampingorvibration.Themoldisraised,and
C09.47 on Self-Consolidating Concrete.
the concrete is allowed to spread. After spreading ceases, two
Current edition approved July 1, 2018. Published October 2018. Originally
approved in 2009. Last previous edition approved in 2014 as C1611/C1611M – 14.
DOI: 10.1520/C1611_C1611M-18.
2 4
Section on Safety Precautions, Manual of Aggregate and Concrete Testing, For referenced ASTM standards, visit the ASTM website, www.astm.org, or
Annual Book of ASTM Standards, Vol 04.02. contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
3
Section on Safety Precautions, Manual of Aggregate and Concrete Testing, Standards volume information, refer to the standard’s Document Summary page on
Annual Book of ASTM Standards, Vol 04.02. the ASTM website.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
C1611/C1611M − 18
diameters of the concrete mass are measured in approximately shim the base plate so that it is fully supported. Dampen the
orthogonal directions. Slump flow is the average of the two work surface, removing any standing water. Do not subject the
diameters. work surface or mold to vibration or disturbance.
8.1.1 Whenperformingtheslumpflowtestforagivenstudy
5. S
...
This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: C1611/C1611M − 14 C1611/C1611M − 18
Standard Test Method for
1
Slump Flow of Self-Consolidating Concrete
This standard is issued under the fixed designation C1611/C1611M; the number immediately following the designation indicates the year
of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.
A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope*
1.1 This test method covers the determination of slump flow of self-consolidating concrete (SCC).
1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each
system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the
two systems may result in non-conformance with the standard.
1.3 The text of this standard references notes and footnotes that provide explanatory material. These notes and footnotes
(excluding those in tables and figures) shall not be considered as requirements of the standard. (Warning—Fresh hydraulic
2
cementitious mixtures are caustic and may cause chemical burns to skin and tissue upon prolonged exposure. )
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety safety, health, and healthenvironmental practices and determine the
applicability of regulatory limitations prior to use. (Warning—Fresh hydraulic cementitious mixtures are caustic and may cause
3
chemical burns to skin and tissue upon prolonged exposure. )
1.5 This international standard was developed in accordance with internationally recognized principles on standardization
established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued
by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
2. Referenced Documents
4
2.1 ASTM Standards:
C125 Terminology Relating to Concrete and Concrete Aggregates
C143/C143M Test Method for Slump of Hydraulic-Cement Concrete
C172 Practice for Sampling Freshly Mixed Concrete
C173/C173M Test Method for Air Content of Freshly Mixed Concrete by the Volumetric Method
C670 Practice for Preparing Precision and Bias Statements for Test Methods for Construction Materials
C1758/C1758M Practice for Fabricating Test Specimens with Self-Consolidating Concrete
3. Terminology
3.1 For definitions of terms used in this test method, refer to Terminology C125.
3.2 Definitions of Terms Specific to This Standard:
3.2.1 halo, n—an observed cement paste or mortar ring that has clearly separated from the coarse aggregate, around the outside
circumference of concrete after flowing from the mold.
3.2.2 spread, n—the distance of lateral flow of concrete during the slump-flow test.
3.2.3 stability, n—the ability of a concrete mixture to resist segregation of the paste from the aggregates.
3.2.4 viscosity, n—resistance of a material to flow under an applied shearing stress.
1
This test method is under the jurisdiction of ASTM Committee C09 on Concrete and Concrete Aggregates and is the direct responsibility of Subcommittee C09.47 on
Self-Consolidating Concrete.
Current edition approved April 1, 2014July 1, 2018. Published May 2014October 2018. Originally approved in 2009. Last previous edition approved in 20092014 as
ε1
C1611/C1611M – 09b14. . DOI: 10.1520/C1611_C1611M-14.10.1520/C1611_C1611M-18.
2
Section on Safety Precautions, Manual of Aggregate and Concrete Testing, Annual Book of ASTM Standards, Vol 04.02.
3
Section on Safety Precautions, Manual of Aggregate and Concrete Testing, Annual Book of ASTM Standards, Vol 04.02.
4
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
C1611/C1611M − 18
4. Summary of Test Method
4.1 A sample of freshly mixed concrete is placed in a mold either in the upright or inverted position. The concrete is placed in
one lift without tamping or vibration. The mold is raised, and the concrete is allowed to
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.