Standard Test Method for Length Change of Hardened Hydraulic-Cement Mortar and Concrete

SIGNIFICANCE AND USE
Measurement of length change permits assessment of the potential for volumetric expansion or contraction of mortar or concrete due to various causes other than applied force or temperature change. This test method is particularly useful for comparative evaluation of this potential in different hydraulic-cement mortar or concrete mixtures.
This test method provides useful information for experimental purposes or for products that require testing under nonstandard mixing, placing, handling, or curing conditions, such as high product workability or different demolding times. Standard conditions are described in 5.4.1.
If conditions for mixing, curing, sampling, and storage other than specified in this test method are required, they shall be reported but are not to be considered as standard conditions of this test method. Nonstandard conditions and the reasons for departure from standard conditions shall be reported clearly and prominently with comparator values.
SCOPE
1.1 This test method covers the determination of the length changes that are produced by causes other than externally applied forces and temperature changes in hardened hydraulic-cement mortar and concrete specimens made in the laboratory and exposed to controlled conditions of temperature and moisture.
1.2 The values stated in either inch-pound or SI units are to be regarded separately as standard. An exception is with regard to sieve sizes and nominal size of aggregate, in which the SI values are the standard as stated in Specification E 11. Within the text, the SI units are shown in brackets. The values stated in each system are not exact equivalents; therefore, each system must be used independently of the other, without combining values in any way.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
31-May-2006
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM C157/C157M-06 - Standard Test Method for Length Change of Hardened Hydraulic-Cement Mortar and Concrete
English language
7 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: C 157/C 157M – 06
Standard Test Method for
Length Change of Hardened Hydraulic-Cement Mortar and
1
Concrete
This standard is issued under the fixed designation C 157/C 157M; the number immediately following the designation indicates the year
of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.
A superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope* C 490 Practice for Use of Apparatus for the Determination
of Length Change of Hardened Cement Paste, Mortar, and
1.1 This test method covers the determination of the length
Concrete
changes that are produced by causes other than externally
C511 Specification for Mixing Rooms, Moist Cabinets,
applied forces and temperature changes in hardened hydraulic-
Moist Rooms, and Water Storage Tanks Used in the
cement mortar and concrete specimens made in the laboratory
Testing of Hydraulic Cements and Concretes
and exposed to controlled conditions of temperature and
C 596 Test Method for Drying Shrinkage of Mortar Con-
moisture.
taining Hydraulic Cement
1.2 The values stated in either inch-pound or SI units are to
C 1347 PracticeforPreparationandDissolutionofUranium
be regarded separately as standard.An exception is with regard
Materials for Analysis
to sieve sizes and nominal size of aggregate, in which the SI
E11 Specification for Wire Cloth and Sieves for Testing
values are the standard as stated in SpecificationE11. Within
Purposes
the text, the SI units are shown in brackets. The values stated
E 337 Test Method for Measuring Humidity with a Psy-
in each system are not exact equivalents; therefore, each
chrometer (the Measurement of Wet- and Dry-Bulb Tem-
system must be used independently of the other, without
peratures)
combining values in any way.
1.3 This standard does not purport to address all of the
3. Terminology
safety concerns, if any, associated with its use. It is the
3.1 Definitions—The terms used in this test method are
responsibility of the user of this standard to establish appro-
defined in Terminology C 125.
priate safety and health practices and determine the applica-
3.2 Definitions of Terms Specific to This Standard:
bility of regulatory limitations prior to use.
3.2.1 length change, n—an increase or decrease in the
2. Referenced Documents lengthofatestspecimenthathasbeencausedtochangebyany
2
factor other than externally applied forces and temperature
2.1 ASTM Standards:
changes.
C 125 Terminology Relating to Concrete and Concrete
Aggregates
4. Significance and Use
C 143/C 143M Test Method for Slump of Hydraulic-
4.1 Measurement of length change permits assessment of
Cement Concrete
the potential for volumetric expansion or contraction of mortar
C 172 Practice for Sampling Freshly Mixed Concrete
or concrete due to various causes other than applied force or
C 192/C 192M Practice for Making and Curing Concrete
temperature change. This test method is particularly useful for
Test Specimens in the Laboratory
comparative evaluation of this potential in different hydraulic-
C 305 PracticeforMechanicalMixingofHydraulicCement
cement mortar or concrete mixtures.
Pastes and Mortars of Plastic Consistency
4.2 This test method provides useful information for experi-
mental purposes or for products that require testing under
1
This test method is under the jurisdiction of ASTM Committee C09 on
nonstandard mixing, placing, handling, or curing conditions,
Concrete and ConcreteAggregates and is the direct responsibility of Subcommittee
such as high product workability or different demolding times.
C09.68 on Volume Change.
Standard conditions are described in 5.4.1.
CurrenteditionapprovedJune1,2006.PublishedJuly2006.Originallyapproved
in 1940. Last previous edition approved in 2004 as C 157/C 157M – 04.
4.3 If conditions for mixing, curing, sampling, and storage
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
other than specified in this test method are required, they shall
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
be reported but are not to be considered as standard conditions
Standards volume information, refer to the standard’s Document Summary page on
of this test method. Nonstandard conditions and the reasons for
the ASTM website.
*A Summary of Changes section appears at the end of this standard.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
C 157/C 157M – 06
departure from standard conditions shall be reported clearly until it just starts to slip. Mount the atmometer on a stand with
and prominently
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.