ASTM F539-01(2011)
(Practice)Standard Practice for Fitting Athletic Footwear
Standard Practice for Fitting Athletic Footwear
SIGNIFICANCE AND USE
Improperly fitted footwear can cause discomfort, but more importantly, prolonged use causes disfiguration of the bone structure, bunions, corns, callouses, and finally fatigue, often leading to serious accidents. Footwear performance may also be diminished if improperly fitted.
SCOPE
1.1 This practice covers a practical method for fitting athletic footwear. This practice is applicable to the following general flexible types of footwear: running baseball, basketball, football, and tennis.
1.2 There are as many variations in shoe forms and materials available to users as there are variations in the anatomy of the user's feet. Shoe forms are different due to manufacturer's materials, type of construction, and also the type of activity anticipated in its end use.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: F539 − 01 (Reapproved 2011) An American National Standard
Standard Practice for
1
Fitting Athletic Footwear
ThisstandardisissuedunderthefixeddesignationF539;thenumberimmediatelyfollowingthedesignationindicatestheyearoforiginal
adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.Asuperscript
epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 4. Apparatus
2
4.1 Measuring Device, suitableforperformingthemeasure-
1.1 This practice covers a practical method for fitting
ments described in this practice.
athletic footwear. This practice is applicable to the following
generalflexibletypesoffootwear:runningbaseball,basketball,
5. Measurement Procedure
football, and tennis.
5.1 Prepare the measuring device by setting the movable
1.2 There are as many variations in shoe forms and mate-
width bar to its widest position and with the movable ball to
rials available to users as there are variations in the anatomy of
heel length indicator (pointer) slid back, so that the foot can be
the user’s feet. Shoe forms are different due to manufacturer’s
easily positioned in the device (Fig. 1).
materials, type of construction, and also the type of activity
5.2 The subject should be in a standing position during
anticipated in its end use.
measurement of the foot with footwear removed from both
1.3 This standard does not purport to address all of the
feet. The subject should wear a sock similar to one that will be
safety concerns, if any, associated with its use. It is the
worn while wearing the footwear being fitted.
responsibility of the user of this standard to establish appro-
5.3 Have the subject place their right heel in the area
priate safety and health practices and determine the applica-
marked for the right heel. The person being measured should
bility of regulatory limitations prior to use.
stand with their weight distributed equally between both feet to
ensure that the foot has elongated to it’s maximum size. To
2. Terminology
ensure the heel is properly located in the back of the heel cup,
2.1 Definitions:
grasp the ankle and device together (Fig. 2).
2.1.1 end use, n—theuseforwhichthefootwearisintended.
5.4 Determination of Toe-to-Heel Length (Toe Length)—
2.1.2 last, n—a block or form shaped like a person’s foot,
Take measurement by looking straight down over the end of
used by shoemakers in building or repairing shoes and boots.
the toes. Make sure the sock is pulled tightly over the toes
without drawing the toes back. Press the toes down so that they
2.1.3 improperly fitted—a term descriptive of footwear that
lie flat against the base of the device and read the size of the
is either too loose or too tight on the foot for its intended
longest toe (not always the first toe). This is the toe-to-heel
purpose or protection thereof.
measurement (see Fig. 3).
2.1.4 subject—person on whom foot measurements are
5.5 Determination of Ball-to-Heel Length (Arch Length)—
made.
Place the thumb over the ball joint of the foot as shown in Fig.
4 and move the pointer so that the inner curved side of the
3. Significance and Use
pointer fits around the ball joint of the foot and the two high
3.1 Improperly fitted footwear can cause discomfort, but ribs of the pointer come in contact with the thumb as shown in
Fig. 4. When the pointer is in proper adjustment, the low
more importantly, prolonged use causes disfiguration of the
bone structure, bunions, corns, callouses, and finally fatigue, middle rib (marked A in Fig. 4) will be touching the bone on
the side of the foot (marked B in Fig. 4). This may be checked
often leading to serious accidents. Footwear performance may
also be diminished if improperly fitted. with the index finger. Read the size indicated by the pointer as
the arch length.
1
This practice is under the jurisdiction of ASTM Committee F08 on Sports
2
Equipment, Playing Surfaces, and Facilitiesand is the direct responsibility of The sole source of supply of the apparatus known to the committee at this time
Subcommittee F08.54 on Athletic Footwear. is the Brannock Device Co., 509 East Fayette St., Syracuse, NY 13202. If you are
Current edition approved Nov. 1, 2011. Published February 2012. Originally aware of alternative suppliers, please provide this information to ASTM Interna-
approved in 1978. Last previous edition approved in 2007 as F539 – 01 (2007). tional Headquarters. Your comments will receive careful consideration at a meeting
1
DOI: 10.1520/F0539-01R11. of the responsible technical committee, which you may attend.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
F539 − 01 (2011)
FIG. 1 Measuring Device
FIG. 2 Placemen
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.