ASTM F288-96(2002)
(Specification)Standard Specification for Tungsten Wire for Electron Devices and Lamps
Standard Specification for Tungsten Wire for Electron Devices and Lamps
ABSTRACT
This specification covers three types of drawn pure and thoriated tungsten wire suitable for fabrication into parts for electron tubes, lamps, and other electron devices, and one type of rod for metal-to-glass sealing (grid wire is excepted): Type 1A, Type 1B, Type 2A, and Type 2B. Types 1A and 1B are designated as UNS R07005; Type 2A is designated as UNS R07911; and Type 2B is designated as UNS R07912. The wire and rod shall conform to the prescribed chemical requirements for thoria and tungsten and to the specified physical properties such as tensile strength, ductility, and surface defects. The weight/diameter conversion formulas are given. Wires shall be furnished in the following specified finishes: Finish 1, Finish 2, Finish 3, Finish 4, Finish 5, Finish 6, and Finish 7. The material shall be smooth, free of twists, bends, kinks, curls, and as free of dents, swaging marks, scratches, die marks, laps, seams, splits, slivers, inclusions, bumps, pits, grooves, cracks, and other physical defects Unless black finish is specified, all types of wire shall have a clean finish, free of graphite, grease, oil, and lubricants. Wire for hooks, supports, springs, anchors, and mesh shall have a bright smooth surface free of cracks holes, or craters. The requirements for straightness, and coiling and spooling are detailed as well. The following analysis and tests shall be performed: chemical analysis, tensile test, ductility test, visual inspection, dimensional measurements, and examination for surface flaws.
SCOPE
1.1 This specification covers three types of drawn wire suitable for fabrication into parts for electron tubes, lamps, and other devices; and one type of rod for metal-to-glass sealing (grid wire is excepted):
1.1.1 Type 1—ACommercially pure nonsag wire (Note 2 and Note 3).
1.1.2 Type 1—BCommercially pure rod suitable for metal-to-glass sealing.
1.1.3 Type 2—AThoriated filament wire containing 1 % thoria.
1.1.4 Type 2BThoriated filament wire containing 2 % thoria.
1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.
1.3 Types 1A and 1B are designated as UNS R07005. Type 2A is designated as UNS R07911. Type 2B is designated as UNS R07912.
1.4 The following precautionary caveat pertains only to the Chemical Analysis, Section 12 of this specification:This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Note 1—A dimensional measurement method for testing nonsag tungsten wire above 0.030 in. (0.76 mm) in diameter is provided in Test Method F 269.
Note 2—Acceptance of nonsag wire characteristics for particular applications of size shall be by agreement between producer and consumer based on either a flashed microstructure as shown by photomicrographs, or on dimensional measurement limits determined in accordance with Test Method F 269.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: F 288 – 96 (Reapproved 2002)
Standard Specification for
1
Tungsten Wire for Electron Devices and Lamps
This standard is issued under the fixed designation F 288; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope F 16 Test Methods for Measuring Diameter or Thickness of
2
Wire and Ribbon for Electronic Devices and Lamps
1.1 This specification covers three types of drawn wire
F 204 Test Method for Surface Flaws in Tungsten Seal Rod
suitable for fabrication into parts for electron tubes, lamps, and
2
and Wire
other devices; and one type of rod for metal-to-glass sealing
F 205 Test Method for Measuring Diameter of FineWire by
(grid wire is excepted):
2
Weighing
1.1.1 Type 1A—Commercially pure nonsag wire (Note 2
F219 TestMethodsofTestingFineRoundandFlatWirefor
and Note 3).
2
Electron Devices and Lamps
1.1.2 Type 1B—Commercially pure rod suitable for metal-
2
F 269 Test Method for Sag of Tungsten Wire
to-glass sealing.
2.2 Military Standards:
1.1.3 Type 2A—Thoriated filament wire containing 1 %
MIL-STD-105 Sampling Procedures and Tables for Inspec-
thoria.
3
tion by Attributes
1.1.4 Type 2B—Thoriated filament wire containing 2 %
3
MIL-STD-129 Marking for Shipment and Storage
thoria.
1.2 The values stated in inch-pound units are to be regarded
3. Terminology
as the standard. The values given in parentheses are for
3.1 Definition of Terms Specific to This Standard:
information only.
3.1.1 wire—The term wire as used in this specification
1.3 Types 1A and 1B are designated as UNS R07005. Type
applies to all drawn material that is spooled or coiled, and to
2A is designated as UNS R07911. Type 2B is designated as
short cut lengths 0.020 in. (0.51 mm) or less in diameter.
UNS R07912.
3.1.2 nonsag or doped tungsten wire—This term designates
1.4 The following precautionary caveat pertains only to the
a wire which, when recrystallized, shows elongated interlock-
Chemical Analysis, Section 12 of this specification: This
ing grains.
standard does not purport to address all of the safety concerns,
3.1.3 rod—The term rod as used in this specification applies
if any, associated with its use. It is the responsibility of the user
to centerless ground material 0.020 in. (0.51 mm) or larger in
of this standard to establish appropriate safety and health
diameter, in short cut lengths or random cut lengths.
practices and determine the applicability of regulatory limita-
tions prior to use.
4. Ordering Information
NOTE 1—Adimensional measurement method for testing nonsag tung-
4.1 Orders for wire and rod furnished to this specification
sten wire above 0.030 in. (0.76 mm) in diameter is provided in Test
shall include the following information:
Method F 269.
4.1.1 Length in metres, or quantity of short cut lengths,
NOTE 2—Acceptance of nonsag wire characteristics for particular
4.1.2 Type and UNS No. (Section 1),
applicationsofsizeshallbebyagreementbetweenproducerandconsumer
4.1.3 Straightness (Section 10),
based on either a flashed microstructure as shown by photomicrographs,
orondimensionalmeasurementlimitsdeterminedinaccordancewithTest 4.1.4 Finish (Section 8),
Method F 269.
4.1.5 Weight or size (Section 7) and tolerance, and
4.1.6 Specification number.
2. Referenced Documents
NOTE 3—Atypical ordering description for straight chemically cleaned
2.1 ASTM Standards:
wire is as follows: xxxx metres, tungsten wire, Type 1A UNS R07005,
straightened, Finish 2; 280.8 mg/200 mm (63 %), to ASTM F288 – XX.
1
This specification is under the jurisdiction of ASTM Committee F01 on
Electronics and is the direct responsibility of Subcommittee F01.03 on Metallic
Materials.
2
Current edition approved June 10, 1996. Published August 1996. Originally Annual Book of ASTM Standards, Vol 10.04.
3
published as B 288 – 54 T; redesignated F 288 in 1955. Last previous edition AvailablefromStandardizationDocumentsOrderDesk,Bldg.4SectionD,700
F 288 – 81 (1991). Robbins Ave., Philadelphia, PA 19111-5094, Attn: NPODS.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
F 288
2
5. Chemical Composition
wt in mg/200 mm5~diameter in mils! 3 1.905, or
2
~diameter in mm! 3 2953
5.1 The wire and rod shall conform to the chemical require-
ments specified in Table 1. The sample for analysis shall be
representative of the lot submitted. Lot size, sample size, and 7.3.3 The weight of Type 2B wire (density 18.50), is as
sampling method shall be as agreed upo
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.