Standard Specification for Concrete Masonry Units for Construction of Catch Basins and Manholes

ABSTRACT
This specification covers solid precast segmental concrete masonry units made from hydraulic cement, water, and suitable mineral aggregates, with or without the inclusion of other materials. The units are intended for use in the construction of catch basins and manholes. All units shall be sound and free of cracks or other defects that interfere with the proper placing of the unit.
SCOPE
1.1 This specification covers solid precast segmental concrete masonry units made from hydraulic cement, water, and suitable mineral aggregates, with or without the inclusion of other materials. The units are intended for use in the construction of catch basins and manholes.
1.2 The text of this standard referenced notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.

General Information

Status
Historical
Publication Date
14-May-2005
Current Stage
Ref Project

Relations

Effective Date
15-May-2005

Buy Standard

Technical specification
ASTM C139-05 - Standard Specification for Concrete Masonry Units for Construction of Catch Basins and Manholes
English language
2 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: C139 – 05
Standard Specification for
Concrete Masonry Units for Construction of Catch Basins
1
and Manholes
This standard is issued under the fixed designation C139; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope* C1232 Terminology of Masonry
1.1 This specification covers solid precast segmental con-
3. Terminology
crete masonry units made from hydraulic cement, water, and
3.1 Terminology defined in Terminology C1209 and Termi-
suitable mineral aggregates, with or without the inclusion of
nology C1232 shall apply for this specification.
other materials. The units are intended for use in the construc-
tion of catch basins and manholes.
4. Materials
1.2 The text of this standard referenced notes and footnotes
4.1 Cementitious materials shall conform to the following
which provide explanatory material. These notes and footnotes
ASTM specifications:
(excluding those in tables and figures) shall not be considered
4.1.1 Portland Cement— Specification C150.
as requirements of the standard.
4.1.2 Blended Hydraulic Cements—Specification C595.
4.1.3 Hydraulic Cement—Specification C1157.
2. Referenced Documents
2
4.1.4 Ground Blast-Furnace Slag—Specification C989.
2.1 ASTM Standards:
4.1.5 Hydrated Lime— Type S of Specification C207.
C33 Specification for Concrete Aggregates
4.1.6 Fly Ash—Specification C618.
C140 Test Methods for Sampling and Testing Concrete
4.1.7 Siliceous and Pozzolanic Materials—Siliceous and
Masonry Units and Related Units
pozzolanic materials shall conform to applicable ASTM stan-
C150 Specification for Portland Cement
dards, or shall be shown by test or experience to be not
C207 Specification for Hydrated Lime for Masonry Pur-
detrimental to the durability of the concrete.
poses
4.2 Aggregates—Aggregates shall conform to Specification
C595 Specification for Blended Hydraulic Cements
C33, except grading requirements shall not apply.
C618 Specification for Coal Fly Ash and Raw or Calcined
4.3 Other Constituents—Air-entraining agents, coloring
Natural Pozzolan for Use in Concrete
pigments, integral water repellents, finely ground silica, and
C989 Specification for Slag Cement for Use in Concrete
otherconstituentsshallbepreviouslyestablishedassuitablefor
and Mortars
use in concrete masonry units and shall conform to applicable
C1157 Performance Specification for Hydraulic Cement
ASTM standards or shall be shown by test or experience not to
C1209 Terminology of Concrete Masonry Units and Re-
3 be detrimental to the durability of the concrete masonry units
lated Units
or any material customarily used in masonry construction.
1
5. Physical Requirements Physical Requirements
This specification is under the jurisdiction of ASTM Committee C15 on
Manufactured Masonry Units and is the direct responsibility of Subcommittee
5.1 At the time of delivery to the site of the work, the units
C15.03 on Concrete Masonry Units and Related Units.
shall conform to the requirements prescribed in Table 1.
Current edition approved May 15, 2005. Published June 2005. Originally
approved in 1938. Last previous edition approved in 2003 as C139 – 03. DOI:
6. Dimensions and Permissible Variations
10.1520/C0139-05.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
6.1 Thethicknessofanyunitshallbenotlessthan5in.(127
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
mm).
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website. 6.2 Overall dimensions shall not vary by more than 63%
3
Withdrawn. The last approved version of this historical standard is referenced
from the specified dimensions.
on www.astm.org.
*ASummary of Changes section appears at the end of this standard.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
C139 – 05
TABLE 1 Strength and Absorption Requirements
9. Compliance
Compressive Strength, min, psi (MPa) Water Absorption,
9.1 If a sample fails to conform to the specified require-
3 3
(Average Gross Area) max, lb/ft (kg/m )
ments, the manufacturer shall be permitted to remove units
Average of 3 Units Individual Unit (Average of 3 Units)
2500 (17) 2000 (13) 10 (16) from the shipment. A new sample shall be selected by the
purchaser from remaining units from the shipment with a
similar configuration and dimension and tested at the expense
of the manufacturer. If the second sample meets the specified
7. Sampling and
...