Standard Specification for Candle Fire Safety Labeling

ABSTRACT
This specification covers requirements for fire safety information to be placed on candle units of sale. It also includes requirements that retailers and distributors shall follow. Fire safety warnings will help ensure that information concerning the safe use of candles is presented to consumers to help prevent fires. The fire safety warning must be placed on the unit of sale and shall be visible to the consumer at the point of sale. The fire safety warning shall not be covered, obstructed, or removed by the manufacturer, distributor or retailer. The text-only fire safety warning shall consist of the safety alert symbol followed immediately by the signal word WARNING in uppercase boldface letters. The text-and-pictogram fire safety warning shall consist of the safety alert symbol followed immediately by the pictograms.
SIGNIFICANCE AND USE
5.1 Fire safety warnings will help ensure that information concerning the safe use of candles is presented to consumers to help prevent fires.
SCOPE
1.1 This specification covers requirements for fire safety information to be placed on candle units of sale. It also includes requirements that retailers and distributors shall follow. It is not the intent of this specification to address any other labeling requirements.2

General Information

Status
Historical
Publication Date
30-Sep-2014
Technical Committee
Drafting Committee
Current Stage
Ref Project

Buy Standard

Technical specification
ASTM F2058-07(2014) - Standard Specification for Candle Fire Safety Labeling
English language
9 pages
sale 15% off
Preview
sale 15% off
Preview
Technical specification
REDLINE ASTM F2058-07(2014) - Standard Specification for Candle Fire Safety Labeling
English language
9 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:F2058 −07 (Reapproved 2014)
Standard Specification for
Candle Fire Safety Labeling
This standard is issued under the fixed designation F2058; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 3.1.2 filled candle, n—a candle produced and used within
the same vessel.
1.1 This specification covers requirements for fire safety
3.1.3 fire safety warning, n—precautionary information on
information to be placed on candle units of sale. It also
includes requirements that retailers and distributors shall fol- the label, consisting of the safety alert symbol, the signal word
(ifpresent),thefiresafetywarningstatement(s)andpictograms
low.Itisnottheintentofthisspecificationtoaddressanyother
(if present) required by this standard to appear on the unit of
labeling requirements.
sale.
2. Referenced Documents
3.1.4 fire safety warning statement(s), n—specific warning
message(s) required by this standard.
2.1 ASTM Standards:
F1972Guide for Terminology Relating to Candles and
3.1.5 freestanding candle, n—rigid candle (for example,
Associated Accessory Items
pillar-shaped,column-shaped,orfigurine)thatisintendedtobe
burned only on a heat-resistant, noncombustible surface or on
3. Terminology
a heat-resistant, noncombustible candle accessory.
3.1 Definitions of Terms Specific to This Standard:
3.1.6 label, n—display of textual or graphic matter on the
3.1.1 Certain candle-related terminology is addressed in
unit of sale.
Guide F1972, and the reader is directed to that guide for
3.1.7 packaging, n—external container, such as a box, case,
definitions not found in the following:
bag or sleeve in which a candle(s) is sold. Packaging does not
include the vessel of a filled candle.
3.1.8 pictogram, n—graphic symbol intended to convey a
This specification is under the jurisdiction of ASTM Committee F15 on
Consumer Products and is the direct responsibility of Subcommittee F15.45 on
message without the use of words.
Candle Products.
3.1.9 safety alert symbol, n—graphic symbol consisting of
Current edition approved Oct. 1, 2014. Published December 2014. Originally
approved in 2000. Last previous edition approved in 2007 as F2058–07. DOI: an exclamation point inside of an equilateral triangle with the
10.1520/F2058-07R14.
point of the triangle oriented upward (see 4.1).
It is possible that labels for use or distribution in certain countries, states,
3.1.10 signal word, n—thewordWARNINGasitappearsin
communitiesorlocationswillrequireotherinformationnotcoveredinthisstandard
or additional language(s). It is the responsibility of the manufacturer to determine
the fire safety warning.
what additional information is necessary to comply with other applicable labeling
3.1.11 unit of sale, n—thecandle,orcandleanditscontainer
regulations.
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
or package, as purchased by the consumer.
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
3.1.12 warning panel, n—entire surface of the panel on
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website. which the fire safety warning appears on the unit of sale.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
F2058−07 (2014)
4. Graphic Symbols Specific To This Standard (1)The fire safety warning shall appear on the top or sides
of the packaging, or must be otherwise attached to the
4.1 Safety Alert Symbol:
packaging (such as a tag). It cannot be on the bottom of the
package as intended for display at retail unless the statement
“See bottom panel for safety information” or its practical
equivalent appears on the top or a side of the packaging with
a minimum letter height of 1.5 mm (0.06 in.) based on the
height of a capital or upper case letter.
(2) For free standing and filled candles (excluding
4.2 Pictogram for “Burn within sight”:
tealights), the fire safety warning must appear on the top,
bottom, or a side of the candle as well as on the packaging.
(3)When the sole packaging consists of a transparent
material (such as a clear shrink wrap) and the fire safety
warningisvisibleonthetop,bottomorasideofthecandle,the
fire safety warning and the statement “See bottom panel for
safety information” is not required on the packaging.
4.3 Pictogram for “Keep away from things that catch fire”:
6.2.2 The fire safety warning shall be in distinct contrast
from its background. Its message(s) shall be in a legible
sans-serif font, such as Helvetica, Century Gothic, or equiva-
lent typeface, in combinations of uppercase and lowercase
letters unless otherwise specified.
6.2.3 The fire safety warning need not be limited to a
4.4 Pictogram for “Keep away from children”: specific shape. It can conform to the shape of the overall label
to allow for the most efficient use of available space. It is
permissible to outline the fire safety warning with a border.
6.2.4 There are two fire safety warning options. One is a
text-onlyoption(see6.3)andtheotherisatext-and-pictogram
option(see6.4).Allunitsofsaleshallcomplywithoneofthese
two labeling options.
6.2.5 The fire safety warning statement(s) specified in this
5. Significance and Use
standard represent minimum fire safety warning requirements.
5.1 Fire safety warnings will help ensure that information
Additionalappropriatemanufacturers’warningsorinstructions
concerningthesafeuseofcandlesispresentedtoconsumersto
are permitted. These warnings or instructions can precede or
help prevent fires.
follow the fire safety warning or appear elsewhere on the unit
of sale, but cannot interrupt the fire safety warning.
6. Requirements
6.2.6 Thetotalsurfaceareaofthewarningpaneldetermines
6.1 Exclusions—Thisspecificationdoesnotpertaintobirth-
the minimum letter height, graphic symbol size and content of
day candles or candles intended for places of worship, com-
thefiresafetywarning.Guidanceonhowtodeterminethetotal
mercial institutions, or industrial use.
surface area of the warning panel is shown in Appendix X1.
6.2.7 Example labels are provided in Appendix X2.
6.2 General:
6.2.1 The fire safety warning must be placed on the unit of
6.3 Fire Safety Warning (Text-Only Option):
sale and shall be visible to the consumer at the point of sale.
6.3.1 The text-only fire safety warning shall consist of the
The fire safety warning shall not be covered, obstructed, or
safety alert symbol followed immediately by the signal word
removed by the manufacturer, distributor or retailer.
“WARNING” in uppercase boldface letters, after which the
6.2.1.1 When the unit of sale consists solely of a candle
following fire safety warning statements or their practical
(including its vessel if present), the fire safety warning shall
equivalents shall appear in this order:
appear on the top, bottom, or a side of the candle, or be
Burn within sight.
attached to the candle (such as a tag).
Keep away from things that catch fire.
6.2.1.2 When the unit of sale consists of a candle and its
Keep away from children.
packaging:
It is permissible for these statements to appear in stacked
format or in paragraph form.
2 2
4 6.3.2 For candles with warning panels of 21 cm (3.3 in. )
The fire-safety pictograms in Section 4 were created by the National Candle
or less, and for all individually labeled taper candles, manu-
Association for the express purpose of developing universally recognized graphic
symbols depicting important candle fire-safety precautions. The National Candle
facturers have the option of using an abbreviated text-only fire
Association has granted to the public the free, universal, and unrestricted rights to
safety warning consisting solely of the safety alert symbol and
use these candle fire-safety symbols without its permission or consideration.
the single fire safety warning statement “Burn within sight” or
Reproduction-quality images of the fire-safety pictograms can be accessed by the
public, without charge, at www.candles.org/pictograms. its practical equivalent.
F2058−07 (2014)
TABLE 1 Minimum Size Requirements for the Components of the
Text-Only Fire Safety Warning Option
Surface Area Minimum Height of Minimum Height of
of the Warning the Safety Alert Symbol Fire Safety Warning
Panel and the Signal Word Statements
“WARNING”
2 2 B
21 cm (3.3 in. ) 1.5 mm (0.06 in.) 1.3 mm (0.05 in.)
A
or less
B
Greater than 1.5 mm (0.06 in.) 1.3 mm (0.05 in.)
2 2
21 cm (3.3 in. )
but less than
2 2
60 cm (9.3 in. )
2 2 B
60 cm (9.3 in. ) 1.8 mm (0.07 in.) 1.5 mm (0.06 in.)
or greater
A
This size label qualifies for the abbreviated text-only fire safety warning option.
See 6.3.2.
B
Minimum height of letters is based on the height of a capital or upper case letter.
TABLE 2 Minimum Size Requirements for the Components of the Text-and-Pictogram Fire Safety Warning Option
Surface Area of Minimum Height of Minimum Diameter of Minimum Height of
the Warning Panel the Safety Alert Symbol the Pictograms the Fire Safety Warning
Statements
2 2 A B C
21 cm (3.3 in. )orless 4mm(0.15 in.) 8 mm (0.31 in.) 1.3 mm (0.05 in.)
2 2 B C
Greater than 21 cm (3.3 in. ) 5mm(0.20 in.) 10 mm (0.39 in.) 1.3 mm (0.05 in.)
2 2
but less than 60 cm (9.3 in. )
2 2 B C
60 cm (9.3 in. ) or greater 8 mm (0.31 in.) 16 mm (0.63 in.) 1.5 mm (0.06 in.)
A
This size label qualifies for the abbreviated text-and-pictogram fire safety warning option. See 6.4.2.
B
The minimum height of the safety alert symbol must always be at least half the height of the pictogram(s). If the pictogram(s) is larger than the minimum size, the safety
alert symbol must be enlarged to at least half of the pictogram’s height.
C
Minimum height of letters is based on the height of a capital or upper case letter.
2 2
6.3.3 The minimum size requirements for components of 6.4.2 Forcandleswithwarningpanelsof21cm (3.3in. )or
the text-only fire safety warning (including the abbreviated less, and for all individually labeled taper candles, manufac-
text-only fire safety warning) are indicated in Table 1.
turers have the option of using an abbreviated text-and-
pictogram fire safety warning consisting solely of the safety
6.4 Fire Safety Warning (Text-and-Pictogram Option):
alert symbol followed by the “Burn within sight” pictogram
6.4.1 The text-and-pictogram fire safety warning shall con-
(see 4.2) and the fire safety warning statement “Burn within
sist of the safety alert symbol followed immediately by the
sight” or its practical equivalent.
pictograms shown in 4.2, 4.3, and 4.4, in that order. Immedi-
ately following or in close proximity to the pictograms, the
6.4.3 The minimum size requirements for the components
following fire safety warning statements or their p
...


This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: F2058 − 07 F2058 − 07 (Reapproved 2014)
Standard Specification for
Candle Fire Safety Labeling
This standard is issued under the fixed designation F2058; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 This specification covers requirements for fire safety information to be placed on candle units of sale. It also includes
requirements that retailers and distributors shall follow. It is not the intent of this specification to address any other labeling
requirements.
2. Referenced Documents
2.1 ASTM Standards:
F1972 Guide for Terminology Relating to Candles and Associated Accessory Items
3. Terminology
3.1 Definitions of Terms Specific to This Standard:
3.1.1 Certain candle-related terminology is addressed in Guide F1972, and the reader is directed to that guide for definitions not
found in the following:
3.1.2 filled candle, n—a candle produced and used within the same vessel.
3.1.3 fire safety warning, n—precautionary information on the label, consisting of the safety alert symbol, the signal word (if
present), the fire safety warning statement(s) and pictograms (if present) required by this standard to appear on the unit of sale.
3.1.4 fire safety warning statement(s), n—specific warning message(s) required by this standard.
3.1.5 freestanding candle, n—rigid candle (for example, pillar-shaped, column-shaped, or figurine) that is intended to be burned
only on a heat-resistant, noncombustible surface or on a heat-resistant, noncombustible candle accessory.
3.1.6 label, n—display of textual or graphic matter on the unit of sale.
3.1.7 packaging, n—external container, such as a box, case, bag or sleeve in which a candle(s) is sold. Packaging does not
include the vessel of a filled candle.
3.1.8 pictogram, n—graphic symbol intended to convey a message without the use of words.
3.1.9 safety alert symbol, n—graphic symbol consisting of an exclamation point inside of an equilateral triangle with the point
of the triangle oriented upward (see 4.1).
3.1.10 signal word, n—the word WARNING as it appears in the fire safety warning.
3.1.11 unit of sale, n—the candle, or candle and its container or package, as purchased by the consumer.
3.1.12 warning panel, n—entire surface of the panel on which the fire safety warning appears on the unit of sale.
This specification is under the jurisdiction of ASTM Committee F15 on Consumer Products and is the direct responsibility of Subcommittee F15.45 on Candle Products.
Current edition approved Aug. 1, 2007Oct. 1, 2014. Published November 2007December 2014. Originally approved in 2000. Last previous edition approved in 20002007
as F2058 – 00.F2058 – 07. DOI: 10.1520/F2058-07.10.1520/F2058-07R14.
It is possible that labels for use or distribution in certain countries, states, communities or locations will require other information not covered in this standard or additional
language(s). It is the responsibility of the manufacturer to determine what additional information is necessary to comply with other applicable labeling regulations.
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
F2058 − 07 (2014)
4. Graphic Symbols Specific To This Standard
4.1 Safety Alert Symbol:
4.2 Pictogram for “Burn within sight”:
4.3 Pictogram for “Keep away from things that catch fire”:
4.4 Pictogram for “Keep away from children”:
5. Significance and Use
5.1 Fire safety warnings will help ensure that information concerning the safe use of candles is presented to consumers to help
prevent fires.
6. Requirements
6.1 Exclusions—This specification does not pertain to birthday candles or candles intended for places of worship, commercial
institutions, or industrial use.
6.2 General:
6.2.1 The fire safety warning must be placed on the unit of sale and shall be visible to the consumer at the point of sale. The
fire safety warning shall not be covered, obstructed, or removed by the manufacturer, distributor or retailer.
6.2.1.1 When the unit of sale consists solely of a candle (including its vessel if present), the fire safety warning shall appear
on the top, bottom, or a side of the candle, or be attached to the candle (such as a tag).
6.2.1.2 When the unit of sale consists of a candle and its packaging:
(1) The fire safety warning shall appear on the top or sides of the packaging, or must be otherwise attached to the packaging
(such as a tag). It cannot be on the bottom of the package as intended for display at retail unless the statement “See bottom panel
for safety information” or its practical equivalent appears on the top or a side of the packaging with a minimum letter height of
1.5 mm (0.06 in.) based on the height of a capital or upper case letter.
(2) For free standing and filled candles (excluding tealights), the fire safety warning must appear on the top, bottom, or a side
of the candle as well as on the packaging.
(3) When the sole packaging consists of a transparent material (such as a clear shrink wrap) and the fire safety warning is
visible on the top, bottom or a side of the candle, the fire safety warning and the statement “See bottom panel for safety
information” is not required on the packaging.
6.2.2 The fire safety warning shall be in distinct contrast from its background. Its message(s) shall be in a legible sans-serif font,
such as Helvetica, Century Gothic, or equivalent typeface, in combinations of uppercase and lowercase letters unless otherwise
specified.
The fire-safety pictograms in Section 4 were created by the National Candle Association for the express purpose of developing universally recognized graphic symbols
depicting important candle fire-safety precautions. The National Candle Association has granted to the public the free, universal, and unrestricted rights to use these candle
fire-safety symbols without its permission or consideration. Reproduction-quality images of the fire-safety pictograms can be accessed by the public, without charge, at
www.candles.org/pictograms.
F2058 − 07 (2014)
6.2.3 The fire safety warning need not be limited to a specific shape. It can conform to the shape of the overall label to allow
for the most efficient use of available space. It is permissible to outline the fire safety warning with a border.
6.2.4 There are two fire safety warning options. One is a text-only option (see 6.3) and the other is a text-and-pictogram option
(see 6.4). All units of sale shall comply with one of these two labeling options.
6.2.5 The fire safety warning statement(s) specified in this standard represent minimum fire safety warning requirements.
Additional appropriate manufacturers’ warnings or instructions are permitted. These warnings or instructions can precede or follow
the fire safety warning or appear elsewhere on the unit of sale, but cannot interrupt the fire safety warning.
6.2.6 The total surface area of the warning panel determines the minimum letter height, graphic symbol size and content of the
fire safety warning. Guidance on how to determine the total surface area of the warning panel is shown in Appendix X1.
6.2.7 Example labels are provided in Appendix X2.
6.3 Fire Safety Warning (Text-Only Option):
6.3.1 The text-only fire safety warning shall consist of the safety alert symbol followed immediately by the signal word
“WARNING” in uppercase boldface letters, after which the following fire safety warning statements or their practical equivalents
shall appear in this order:
Burn within sight.
Keep away from things that catch fire.
Keep away from children.
It is permissible for these statements to appear in stacked format or in paragraph form.
2 2
6.3.2 For candles with warning panels of 21 cm (3.3 in. ) or less, and for all individually labeled taper candles, manufacturers
have the option of using an abbreviated text-only fire safety warning consisting solely of the safety alert symbol and the single
fire safety warning statement “Burn within sight” or its practical equivalent.
6.3.3 The minimum size requirements for components of the text-only fire safety warning (including the abbreviated text-only
fire safety warning) are indicated in Table 1.
6.4 Fire Safety Warning (Text-and-Pictogram Option):
6.4.1 The text-and-pictogram fire safety warning shall consist of the safety alert symbol followed immediately by the
pictograms shown in 4.2, 4.3, and 4.4, in that order. Immediately following or in close proximity to the pictograms, the following
fire safety warning statements or their practical equivalents shall appear in this order:
Burn within sight.
Keep away from things that catch fire.
Keep away from children.
It is permissible for these statements to appear in stacked format or in paragraph form.
2 2
6.4.2 For candles with warning panels of 21 cm (3.3 in. ) or less, and for all individually labeled taper candles, manufacturers
have the option of using an abbreviated text-and-pictogram fire safety warning consisting solely of the safety alert symbol followed
by the “Burn within sight” pictogram (see 4.2) and the fire safety warning statement “Burn within sight” or its practical equivalent.
6.4.3 The minimum size requirements for the components of the text-and-pictogram fire safety warning (including the
abbreviated text-and-pictogram fire safety warning) are indicated in Table 2.
7. Keywords
7.1 candle; labeling; pictograms; safety
TABLE 1 Minimum Size Requirements for the Components of the
Text-Only Fire Safety Warning Option
Surface Area Minimum Height of Minimum Height of
of the Warning the Safety Alert Symbol Fire Safety Warning
Panel and the Signal Word Statements
“WARNING”
2 2 B
21 cm (3.3 in. ) 1.5 mm (0.06 in.) 1.3 mm (0.05 in.)
A
or less
B
Greater than 1.5 mm (0.06 in.) 1.3 mm (0.05 in.)
2 2
21 cm (3.3 in. )
but less than
2 2
60 cm (9.3 in. )
2 2 B
60 cm (9.3 in. ) 1.8 mm (0.07 in.) 1.5 mm (0.06 in.)
or greater
A
This size label qualifies for the abbreviated text-only fire safety warning option.
See 6.3.2.
B
Minimum height of letters is based on the height of a capital or upper case letter.
F2058 − 07 (2014)
TABLE 2 Minimum Size Requirements for the Components of the Text-and-Pictogram Fire Safety Warning Option
Surface Area of Minimum Height of Minimum Diameter of Minimum Height of
the Warning Panel the Safety Alert Symbol the Pictograms the Fire Safety Warning
Statements
2 2 A B C
21 cm (3.3 in. ) or less 4 mm (0.15 in.) 8 mm (0.31 in.) 1.3 mm (0.05 in.)
2 2 B C
Greater than 21 cm (3.3 in. ) 5 mm (0.20 in.) 10 mm (0.39 in.) 1.3 mm (0.05 in.)
2 2
but less than 60 cm (9.3 in. )
2 2 B C
60 cm (9.3 in. ) or greater 8 mm (0.31 in.) 16 mm (0.63 in.) 1.5 mm (0.06 in.)
A
This size label qualifies for the abbreviated text-and-pictogram fire safety warning option. See 6.4.2.
B
The minimum height of the safety alert symbol must always be at least half the height of the pictogram(s). If the pictogram(s) is larger than the minimum size, the safety
alert symbol must be enlarged to at least half of the pictogram’s height.
C
Minimum height of letters is based on the height of a capital or upper case letter.
APPENDIXES
(Nonmandatory Information)
X1. CALCULATING THE WARNING PANEL SURFACE AREA
X1.1 The letter height and pictogram size requirements of the fire safety warnings depend on the surface area of the panel on
which it appears. This appendix provides information for calculating the warning panel surface area.
X1.2 The first step to determine the minimum size of the components of the fire safety warning is to calculate the entire surface
area of the warning panel. Using that result, refer to Table 1 (for text-only) or Table 2 (for text and pictogram) in the standard to
determine the minimum size requirements for the components of the fire safety warning. It is important to note that it is the total
surface area of the warning panel that is calculated, not the size of the labeled area or only the spot where the fire safety warning
appears. Thus, if a manufacturer uses a 4 by 4 cm adhesive label to place the fire safety warning on the side of a box measuring
10 by 10 cm, the required size of the warning’s text and graphic elements is based on a warning panel surface area of 100 cm
(the surface area of one side of the box), not 16 cm (the surface area of just the adhesive label).
CALCULATIONS FOR SURFACE AREAS
X1.3 Squares and Rectangles—For square or rectangle surfaces, multiply the width (w) by the height (h) to obtain the surface
area. See Fig. X1.1.
NOTE 1—Surface area = w × h
FIG. X1.1 Surface Area of Squares and Rectangles
X1.4 Circles —For round or circular surfaces, multiply the square of the radius (r) by 3.14 (π) to obtain the surface area. See Fig.
X1.2.
X1.5 Cylinders —For the side of cylindrical surfaces, the warning panel is considered to be 40 % of the total surface of the height
of the cylinder. This 40 % represents approximately the area that can be seen at one time by someone looking at the side surface
of the cylinder. To calculate the surface area multiply 0.4 times the diameter (d) times the height (h) times 3.14 (π) (that is, 0.4
× d × h × 3.14). See Fig. X1.3.
F2058 − 07 (2014)
NOTE 1—Surface area = 3.14 × r
FIG. X1.2 Surface Area of Circles
NOTE 1—Surface area = 0.4 × d × h × 3.14. For cylindrical surfaces that
have a rounded neck or shoulder, the height measurement excludes the
neck and shoulder of the container.
FIG. X1.3 Surface Area of Cylinders
F2058 − 07 (2014)
X2. EXAMPLE LABELS
X2.1 The following example labels are provided solely to assist the reader in envisioning some of the many ways in which the
fire safety warning can be used on different candle label formats. The use and placement of the fire safety warning within the
specifications of this standard are at the discretion of the manufacturer.
X2.2 Examples include labels that might appear on the bottom or side
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.