Standard Test Methods for Nonvolatile Matter in Halogenated Organic Solvents and Their Admixtures

SCOPE
1.1 These test methods cover the determination of nonvolatile matter in halogenated organic solvents and admixtures.
1.2 Five test methods are covered, as follows:
1.2.1 Test Method A—For halogenated organic solvents or admixtures having less than 50 ppm nonvolatile matter; or where precision greater than ±10 ppm is required.
1.2.2 Test Method B—For halogenated organic solvents or admixtures having more than 50 ppm nonvolatile matter or where precision of ±0.001 % (10 ppm) is satisfactory.
1.2.3 Test Method C—For low-boiling halogenated organic solvents or their admixtures (for example, methylene chloride, trichlorotrifluoroethane) that may superheat and cause bumping while evaporating to dryness with steam. A precision of greater than ± 10 ppm can be attained.
1.2.4 Test Method D—For rapid measurement of nonvolatile matter in halogenated organic solvents and their admistures and where precision better then ±10 ppm is required.
1.2.5 Test Method E—For halogenated organic solvents or admixtures and where precision better than ±10 ppm is required.
1.3 The values stated in SI units are to be regarded as the standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
09-Dec-2001
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM D2109-96(2000) - Standard Test Methods for Nonvolatile Matter in Halogenated Organic Solvents and Their Admixtures
English language
3 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


NOTICE: This standard has either been superseded and replaced by a new version or withdrawn. Contact ASTM
International (www.astm.org) for the latest information.
An American National Standard
Designation:D2109–96 (Reapproved 2000)
Standard Test Methods for
Nonvolatile Matter in Halogenated Organic
Solvents and Their Admixtures
This standard is issued under the fixed designation D 2109; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope 3. Significance and Use
1.1 These test methods cover the determination of nonvola- 3.1 Nonvolatile matter in solvents can adversely affect their
tile matter in halogenated organic solvents and admixtures. cleaning properties. These test methods can be used to control
1.2 Three test methods are covered, as follows: soil contamination in the boiling solvent, which if allowed to
1.2.1 Test Method A—For halogenated organic solvents or become too high, can decrease the stability of the solvent.
admixtures having less than 50 ppm nonvolatile matter; or 3.2 These test methods can be used to establish manufac-
where precision greater than 610 ppm is required. turing and purchasing specifications.
1.2.2 Test Method B—For halogenated organic solvents or
4. Apparatus
admixtures having more than 50 ppm nonvolatile matter or
where precision of 60.001 % (10 ppm) is satisfactory. 4.1 Oven, thermostatically controlled at 105 6 5°C.
4.2 Evaporating Dish, 125-mL capacity, platinum or high-
1.2.3 Test Method C—For low-boiling halogenated organic
solvents or their admixtures (for example, methylene chloride, silica glass.
4.3 Steam Bath (or hot plate).
trichlorotrifluoroethane) that may superheat and cause bump-
ing while evaporating to dryness with steam. A precision of 4.4 Analytical Balance.
4.5 1000-mL Volumetric Flask (Test Method A).
greater than 610 ppm can be attained.
1.3 The values stated in SI units are to be regarded as the 4.6 100-mL Volumetric Pipet (Test Method B).
4.7 1000-mL Graduated Cylinder (Test Method C).
standard.
1.4 This standard does not purport to address all of the 4.8 1500-mL Erlenmeyer Flask (Test Method C).
safety concerns, if any, associated with its use. It is the
TEST METHOD A
responsibility of the user of this standard to establish appro-
priate safety and health practices and determine the applica-
5. Procedure
bility of regulatory limitations prior to use.
5.1 Dry a 125-mL capacity platinum (or high-silica glass)
evaporating dish in an oven at 105 6 5°C and cool in a
2. Terminology
desiccator. Repeat until the weight is constant or within 0.1 mg
2.1 Definitions of Terms Specific to This Standard:
of the last weighing. Rinse a clean dry 1000-mL volumetric
2.1.1 The term nonvolatile matter should not be construed
flask with the solvent and fill to the 1000-mL mark with the
as equivalent to residue on ignition, ignition residue, or ash
solvent to be tested. Invert the evaporating dish, place it over
content. Particulates, sediments, and suspended matter should
the mouth of the flask, hold it firmly in place, and invert the
not be considered part of nonvolatile residue. If these solids are
flask. In this position place both dish and flask on a steam bath.
present in the sample, they should be removed by filtration or
Adjust a ring support to hold the flask so the mouth of the flask
decantation prior to beginning this test method. Nonvolatile
is approximately 25 mm above the bottom of the evaporating
matter is considered to be“ in solution” with the solvent and
dish. Thus held, the flask automatically feeds the solvent to the
that which will become residual upon drying the solvent at a
dish during the evaporation.
specified temperature.
NOTE 1—Caution: This test method must be run in a ventilated,
dust-free area.
1 5.2 Evaporate the 1000-mL sample to dryness. Remove the
These test methods are under the jurisdiction of ASTM Committee D26 on
dish from the steam bath with metal tongs and blot the outside
Halogenated Organic Solvents and Fire Extinguishing Agents and are the direct
responsibility of Subcommittee D26.04 on Test Methods.
of the dish with lint-free paper tissue.
Current edition approved June 10, 1996. Published August 1996. Originally
published as D 2109 – 62 T. Last previous edition D 2109 – 92. NOTE 2—Hot plates develop high temperatures on the plate surface. If
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn. Contact ASTM
International (www.astm.org) for the latest information.
D2109–96 (2000)
a hot plate is used to evaporate the solvent, the evaporating dish should be
10. Precision and Bias
placed inside a water bath while on the hot plate to prevent the sample
10.1 Precision—As the only significant difference between
from reaching temperatures exceeding 105°C.
Test Method B and Test Methods A and C is the sample size
5.3 Place the dish and contents in an oven at 105 6 5°C for
(100 mL versus
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.