ASTM C923M-07
(Specification)Standard Specification for Resilient Connectors Between Reinforced Concrete Manhole Structures, Pipes, and Laterals (Metric)
Standard Specification for Resilient Connectors Between Reinforced Concrete Manhole Structures, Pipes, and Laterals (Metric)
SCOPE
1.1 This specification covers the minimum performance and material requirements for resilient connectors used for connections between precast reinforced concrete manholes conforming to Specification C 478 and pipes, and between precast reinforced concrete pipe and laterals.
1.1.1 These connectors are designed to minimize leakage between the pipe and manhole, and between the pipe and lateral.
1.2 This specification is the metric counterpart of Specification C 923. Note 1This specification covers the design, material, and performance of the resilient connection only. Connections covered by this specification are adequate for hydrostatic pressures up to 70 kPa (7.1 m) without leakage when tested in accordance with Section . Infiltration or exfiltration quantities for an installed system are dependent upon many factors other than the connections between manhole structures and pipe, and allowable quantities must be covered by other specifications and suitable testing of the installed pipeline and system.
The following precautionary caveat pertains only to the test methods portion, Section 7, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For a specific precaution statement, see 7.2.5.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: C 923M – 07
METRIC
Standard Specification for
Resilient Connectors Between Reinforced Concrete Manhole
1
Structures, Pipes, and Laterals [Metric]
This standard is issued under the fixed designation C 923M; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope A 493 Specification for Stainless Steel Wire and Wire Rods
for Cold Heading and Cold Forging
1.1 This specification covers the minimum performance and
A 666 Specification for Annealed or Cold-Worked Austen-
material requirements for resilient connectors used for connec-
itic Stainless Steel Sheet, Strip, Plate, and Flat Bar
tions between precast reinforced concrete manholes conform-
C 478 Specification for Precast Reinforced Concrete Man-
ing to Specification C 478 and pipes, and between precast
hole Sections
reinforced concrete pipe and laterals.
C 822 Terminology Relating to Concrete Pipe and Related
1.1.1 These connectors are designed to minimize leakage
Products
between the pipe and manhole, and between the pipe and
C 913 Specification for Precast Concrete Water and Waste-
lateral.
water Structures
1.2 This specification is the metric counterpart of Specifi-
D 395 Test Methods for Rubber Property—Compression
cation C 923.
Set
NOTE 1—This specification covers the design, material, and perfor-
D 412 Test Methods for Vulcanized Rubber and Thermo-
mance of the resilient connection only. Connections covered by this
plastic Elastomers—Tension
specification are adequate for hydrostatic pressures up to 70 kPa (7.1 m)
D 471 Test Method for Rubber Property—Effect of Liquids
without leakage when tested in accordance with Section 7. Infiltration or
D 543 Practices for Evaluating the Resistance of Plastics to
exfiltration quantities for an installed system are dependent upon many
factors other than the connections between manhole structures and pipe, Chemical Reagents
and allowable quantities must be covered by other specifications and
D 573 Test Method for Rubber—Deterioration in an Air
suitable testing of the installed pipeline and system.
Oven
D 624 Test Method for Tear Strength of Conventional
1.3 The following precautionary caveat pertains only to the
Vulcanized Rubber and Thermoplastic Elastomers
test methods portion, Section 7, of this specification: This
D 746 Test Method for Brittleness Temperature of Plastics
standard does not purport to address all of the safety concerns,
and Elastomers by Impact
if any, associated with its use. It is the responsibility of the user
D 883 Terminology Relating to Plastics
of this standard to establish appropriate safety and health
D 1171 Test Method for Rubber Deterioration—Surface
practices and determine the applicability of regulatory limita-
Ozone Cracking Outdoors or Chamber (Triangular Speci-
tions prior to use. For a specific precaution statement, see
mens)
7.2.5.
D 1566 Terminology Relating to Rubber
2. Referenced Documents
D 2240 Test Method for Rubber Property—Durometer
2
2.1 ASTM Standards: Hardness
NOTE 2—For more information about wastewater structures, see Speci-
fication C 913.
1
This specification is under the jurisdiction of ASTM Committee C13 on
Concrete Pipe and is the direct responsibility of Subcommittee C13.06 on Manholes
3. Terminology
and Specials.
Current edition approved March 1, 2007. Published March 2007. Originally
3.1 Definitions:
approved in 1980. Last previous edition approved in 2002 as C 923M – 02.
3.1.1 Terms relating to plastics and rubber shall be as
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
defined in Terminologies D 883 and D 1566, respectively.
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
C923M–07
3.1.2 Terms relating to precast concrete pipe, manholes, and between the connector and the pipe. The seal between the
related products shall be as defined in Terminology C 822 and connector and the wall of the manhole or wastewater structure
as modified in 3.1.3-3.1.6. shall be made by either mechanical means, compression of the
3.1.3 connector—the entire assembly including resilient resilient material between the outside surface of the pipe and
seals and metallic or nonmetallic mechanical devices, if any,
the pipe opening in the wall of the manhole or wastewater
used therein. structure,orbycastingtheconnectorintegrallywiththewallof
3.1.4 lateral—the smal
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.