Standard Specification for Ready-Mixed Concrete

ABSTRACT
This specification covers ready-mixed concrete manufactured and delivered to a purchaser in freshly mixed and unhardened state as hereinafter specified. Requirements for quality of concrete shall be either as hereinafter specified or as specified by the purchase. In any case where the requirements of the purchaser differ from these in this specification, the purchaser's specification shall govern. In the absence of designated applicable materials specifications, materials specifications specified shall be used for cementitious materials, hydraulic cement, supplementary cementitious materials, cementitious concrete mixtures, aggregates, air-entraining admixtures, and chemical admixtures. Except as otherwise specifically permitted, cement, aggregate, and admixtures shall be measured by mass. Mixers will be stationary mixers or truck mixers. Agitators will be truck mixers or truck agitators. Test methods for compression, air content, slump, temperature shall be performed. For s strength test, at least two standard test specimens shall be made.
SCOPE
1.1 This specification covers ready-mixed concrete manufactured and delivered to a purchaser in a freshly mixed and unhardened state as hereinafter specified. Requirements for quality of concrete shall be either as hereinafter specified or as specified by the purchaser. In any case where the requirements of the purchaser differ from these in this specification, the purchaser's specification shall govern. This specification does not cover the placement, consolidation, curing, or protection of the concrete after delivery to the purchaser.
1.2 The values stated in either SI units, shown in brackets, or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.
1.3 As used throughout this specification the manufacturer produces ready-mixed concrete. The purchaser buys ready-mixed concrete.
1.4 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.
This standard does not purport to address all the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. (Warning-Fresh hydraulic cementitious mixtures are caustic and may cause chemical burns to skin and tissue upon prolonged use.)

General Information

Status
Historical
Publication Date
31-Dec-2006
Current Stage
Ref Project

Buy Standard

Technical specification
ASTM C94/C94M-07 - Standard Specification for Ready-Mixed Concrete
English language
12 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: C 94/C 94M – 07
Standard Specification for
1
Ready-Mixed Concrete
This standard is issued under the fixed designation C 94/C 94M; the number immediately following the designation indicates the year
of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.
A superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope* C 31/C 31M Practice for Making and Curing Concrete Test
Specimens in the Field
1.1 This specification covers ready-mixed concrete manu-
C33 Specification for Concrete Aggregates
factured and delivered to a purchaser in a freshly mixed and
C 39/C 39M Test Method for Compressive Strength of Cy-
unhardened state as hereinafter specified. Requirements for
lindrical Concrete Specimens
quality of concrete shall be either as hereinafter specified or as
C 125 Terminology Relating to Concrete and Concrete
specified by the purchaser. In any case where the requirements
Aggregates
of the purchaser differ from these in this specification, the
C 138/C 138M Test Method for Density (Unit Weight),
purchaser’s specification shall govern. This specification does
Yield, and Air Content (Gravimetric) of Concrete
not cover the placement, consolidation, curing, or protection of
C 143/C 143M Test Method for Slump of Hydraulic-
the concrete after delivery to the purchaser.
Cement Concrete
1.2 The values stated in either SI units, shown in brackets,
C 150 Specification for Portland Cement
or inch-pound units are to be regarded separately as standard.
C 172 Practice for Sampling Freshly Mixed Concrete
The values stated in each system may not be exact equivalents;
C 173/C 173M Test Method for Air Content of Freshly
therefore,eachsystemshallbeusedindependentlyoftheother.
Mixed Concrete by the Volumetric Method
Combining values from the two systems may result in non-
C 231 Test Method for Air Content of Freshly Mixed
conformance with the standard.
Concrete by the Pressure Method
1.3 As used throughout this specification the manufacturer
C 260 Specification forAir-EntrainingAdmixtures for Con-
produces ready-mixed concrete. The purchaser buys ready-
crete
mixed concrete.
C 330 Specification for Lightweight Aggregates for Struc-
1.4 The text of this standard references notes and footnotes
tural Concrete
which provide explanatory material. These notes and footnotes
C 494/C 494M Specification for Chemical Admixtures for
(excluding those in tables and figures) shall not be considered
Concrete
as requirements of the standard.
C 567 Test Method for Determining Density of Structural
1.5 This standard does not purport to address all the safety
Lightweight Concrete
concerns, if any, associated with its use. It is the responsibility
C 595 Specification for Blended Hydraulic Cements
of the user of this standard to establish appropriate safety and
C 618 Specification for Coal Fly Ash and Raw or Calcined
health practices and determine the applicability of regulatory
Natural Pozzolan for Use in Concrete
limitations prior to use. (Warning—Fresh hydraulic cementi-
C 637 Specification for Aggregates for Radiation-Shielding
tious mixtures are caustic and may cause chemical burns to
2 Concrete
skin and tissue upon prolonged use. )
C 989 Specification for Ground Granulated Blast-Furnace
2. Referenced Documents Slag for Use in Concrete and Mortars
3
C 1017/C 1017M Specification for Chemical Admixtures
2.1 ASTM Standards:
for Use in Producing Flowing Concrete
1
This specification is under the jurisdiction of ASTM Committee C09 on
Concrete and ConcreteAggregates and is the direct responsibility of Subcommittee
C09.40 on Ready-Mixed Concrete.
Current edition approved Jan. 1, 2007. Published February 2007. Originally
approved in 1933. Last previous edition approved in 2005 as C 94/C 94M–05.
2
See Section on Safety Precautions, Manual ofAggregate and Concrete Testing,
Annual Book of ASTM Standards, Vol. 04.02.
3
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website.
*ASummary of Changes section appears at the end of this standard.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
C 94/C 94M – 07
C 1064/C 1064M Test Method for Temperature of Freshly 5.2.1 Hydraulic Cement—Hydraulic cement shall conform
Mixed Hydraulic-Cement Concrete to Specification C 150, Specification C 595, or Specification
C 1077 PracticeforLaboratoriesTestingConcreteandCon- C 1157.
crete Aggregates for Use in Construct
...

Questions, Comments and Discussion