ASTM A418/A418M-10
(Test Method)Standard Practice for Ultrasonic Examination of Turbine and Generator Steel Rotor Forgings
Standard Practice for Ultrasonic Examination of Turbine and Generator Steel Rotor Forgings
SIGNIFICANCE AND USE
This practice shall be used when ultrasonic inspection is required by the order or specification for inspection purposes where the acceptance of the forging is based on limitations of the number, amplitude, or location of discontinuities, or a combination thereof, which give rise to ultrasonic indications.
The acceptance criteria shall be clearly stated as order requirements.
SCOPE
1.1 This practice for ultrasonic examination covers turbine and generator steel rotor forgings covered by Specifications A469/A469M, A470/A470M, A768/A768M, and A940/A940M. This standard shall be used for contact testing only.
1.2 This practice describes a basic procedure of ultrasonically inspecting turbine and generator rotor forgings. It does not restrict the use of other ultrasonic methods such as reference block calibrations when required by the applicable procurement documents nor is it intended to restrict the use of new and improved ultrasonic test equipment and methods as they are developed.
General Information
Relations
Buy Standard
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: A418/A418M − 10
StandardPractice for
Ultrasonic Examination of Turbine and Generator Steel
1
Rotor Forgings
This standard is issued under the fixed designationA418/A418M; the number immediately following the designation indicates the year
of original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.
A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope* should be recognized as a possibility. Rigid control of the
actual frequency used, the coil bandpass width if tuned
1.1 This practice for ultrasonic examination covers turbine
instruments are used, and so forth, tend to reduce the overall
and generator steel rotor forgings covered by Specifications
inaccuracy which is apt to develop.
A469/A469M, A470/A470M, A768/A768M, and A940/
1.5 This practice for inspection applies to solid cylindrical
A940M. This standard shall be used for contact testing only.
forgings having outer diameters of not less than 2.5 in. [64
1.2 This practice describes a basic procedure of ultrasoni-
mm] nor greater than 100 in. [2540 mm]. It also applies to
cally inspecting turbine and generator rotor forgings. It does
cylindrical forgings with concentric cylindrical bores having
not restrict the use of other ultrasonic methods such as
wall thicknesses of 2.5 [64 mm] in. or greater, within the same
reference block calibrations when required by the applicable
outer diameter limits as for solid cylinders. For solid sections
procurement documents nor is it intended to restrict the use of
less than 15 in. [380 mm] in diameter and for bored cylinders
new and improved ultrasonic test equipment and methods as
oflessthan7.5in.[190mm]wallthicknessthetransducerused
they are developed.
for the inspection will be different than the transducer used for
1.3 This practice is intended to provide a means of inspect-
larger sections.
ing cylindrical forgings so that the inspection sensitivity at the
1.6 Supplementary requirements of an optional nature are
forging center line or bore surface is constant, independent of
provided for use at the option of the purchaser. The supple-
the forging or bore diameter.To this end, inspection sensitivity
mentary requirements shall apply only when specified indi-
multiplication factors have been computed from theoretical
vidually by the purchaser in the purchase order or contract.
analysis, with experimental verification. These are plotted in
1.7 This practice is expressed in both inch-pound units and
Fig. 1 (bored rotors) and Fig. 2 (solid rotors), for a true
in SI units; however, unless the purchase order or contract
inspection frequency of 2.25 MHz, and an acoustic velocity of
5 5
specifies the applicable M specification designation (SI units),
2.30×10 in./s[5.85×10 cm/s].Meansofconvertingtoother
the inch-pound units shall apply. The values stated in either
sensitivity levels are provided in Fig. 3. (Sensitivity multipli-
inch-pound units or SI units are to be regarded separately as
cation factors for other frequencies may be derived in accor-
standard. Within the practice, the SI units are shown in
dance with X1.1 and X1.2 of Appendix X1.)
brackets. The values stated in each system may not be exact
1.4 Considerableverificationdataforthismethodhavebeen
equivalents;therefore,eachsystemshallbeusedindependently
generated which indicate that even under controlled conditions
of the other. Combining values from the two systems may
very significant uncertainties may exist in estimating natural
result in nonconformance with the standard.
discontinuities in terms of minimum equivalent size flat-
1.8 This standard does not purport to address all of the
bottom holes. The possibility exists that the estimated mini-
safety concerns, if any, associated with its use. It is the
mum areas of natural discontinuities in terms of minimum
responsibility of the user of this standard to establish appro-
areas of the comparison flat-bottom holes may differ by 20 dB
priate safety and health practices and determine the applica-
(factorof10)intermsofactualareasofnaturaldiscontinuities.
bility of regulatory limitations prior to use.
This magnitude of inaccuracy does not apply to all results but
2. Referenced Documents
1
2.1 The reference is to the latest issue of these designations
This practice is under the jurisdiction of ASTM Committee A01 on Steel,
Stainless Steel and RelatedAlloys and is the direct responsibility of Subcommittee
that appear in the Annual Book of ASTM Standards or are
A01.06 on Steel Forgings and Billets.
available as separate reprints. It shall also apply to product
Current edition approved Nov. 1, 2010. Published December 2010. Originally
specifications, which may be issued when specifically refer-
approved in 1957. Last previous edition
...
This document is not anASTM standard and is intended only to provide the user of anASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation:A418/A418M–09 Designation: A418/A418M – 10
Standard Practice for
Ultrasonic Examination of Turbine and Generator Steel
1
Rotor Forgings
This standard is issued under the fixed designationA418/A418M; the number immediately following the designation indicates the year
of original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.
A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope*
1.1 This practice for ultrasonic examination covers turbine and generator steel rotor forgings covered by Specifications
A469/A469M, A470/A470M, A768/A768M, and A940/A940M. This standard shall be used for contact testing only.
1.2 Thispracticedescribesabasicprocedureofultrasonicallyinspectingturbineandgeneratorrotorforgings.Itdoesnotrestrict
the use of other ultrasonic methods such as reference block calibrations when required by the applicable procurement documents
nor is it intended to restrict the use of new and improved ultrasonic test equipment and methods as they are developed.
1.3 Thispracticeisintendedtoprovideameansofinspectingcylindricalforgingssothattheinspectionsensitivityattheforging
centerlineorboresurfaceisconstant,independentoftheforgingorborediameter.Tothisend,inspectionsensitivitymultiplication
factorshavebeencomputedfromtheoreticalanalysis,withexperimentalverification.TheseareplottedinFig.1(boredrotors)and
5 5
Fig. 2 (solid rotors), for a true inspection frequency of 2.25 MHz, and an acoustic velocity of 2.30 3 10 in./s [5.85 3 10 cm/s].
Means of converting to other sensitivity levels are provided in Fig. 3. (Sensitivity multiplication factors for other frequencies may
be derived in accordance with X1.1 and X1.2 of Appendix X1.)
1.4 Considerable verification data for this method have been generated which indicate that even under controlled conditions
verysignificantuncertaintiesmayexistinestimatingnaturaldiscontinuitiesintermsofminimumequivalentsizeflat-bottomholes.
The possibility exists that the estimated minimum areas of natural discontinuities in terms of minimum areas of the comparison
flat-bottomholesmaydifferby20dB(factorof10)intermsofactualareasofnaturaldiscontinuities.Thismagnitudeofinaccuracy
doesnotapplytoallresultsbutshouldberecognizedasapossibility.Rigidcontroloftheactualfrequencyused,thecoilbandpass
width if tuned instruments are used, and so forth, tend to reduce the overall inaccuracy which is apt to develop.
1.5 This practice for inspection applies to solid cylindrical forgings having outer diameters of not less than 2.5 in. [64 mm] nor
greater than 100 in. [2540 mm]. It also applies to cylindrical forgings with concentric cylindrical bores having wall thicknesses
of 2.5 [64 mm] in. or greater, within the same outer diameter limits as for solid cylinders. For solid sections less than 15 in. [380
mm] in diameter and for bored cylinders of less than 7.5 in. [190 mm] wall thickness the transducer used for the inspection will
be different than the transducer used for larger sections.
1.6 Supplementary requirements of an optional nature are provided for use at the option of the purchaser. The supplementary
requirements shall apply only when specified individually by the purchaser in the purchase order or contract.
1.7 This practice is expressed in both inch-pound units and in SI units; however, unless the purchase order or contract specifies
theapplicableMspecificationdesignation(SIunits),theinch-poundunitsshallapply.Thevaluesstatedineitherinch-poundunits
or SI units are to be regarded separately as standard. Within the practice, the SI units are shown in brackets. The values stated in
eachsystemmaynotbeexactequivalents;therefore,eachsystemshallbeusedindependentlyoftheother.Combiningvaluesfrom
the two systems may result in nonconformance with the standard.
1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory
limitations prior to use.
2. Referenced Documents
2.1 The reference is to the latest issue of these designations that appear in the Annual Book of ASTM Standards or are available
as separate reprints. It shall also apply to product specifications, which may be issued when specifically referenced therein.
2
2.2 ASTM Standards:
1
This practice is under the jurisdiction of ASTM Committee A01 on Steel, Stainless Steel and Related Alloys and i
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.