Standard Test Method for Portable High Anchor Devices

SIGNIFICANCE AND USE
4.1 Static Load Test—This test verifies that the portable high anchor device can support the design load without permanent deformation and continue to function in a safe manner.  
4.2 Load Test for Failure—This test determines the force at which the portable high anchor device fails.
SCOPE
1.1 This test method applies to portable high anchor devices that may be used by rescue personnel during both training exercises and actual rescue operations.  
1.2 This test method covers two mechanical tests, the Static Load Test and the Load Test for Failure.  
1.3 Tests contained herein are destructive in nature. Portable high anchor devices subjected to any of these tests shall not be used in any way after testing except in evaluating the results of such testing.  
1.4 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the standard.  
1.5 This specification does not imply approval of any method of use of portable high anchor devices. In addition, the tests described are laboratory tests and do not duplicate field conditions. Furthermore, the test load values contained herein are not to be interpreted as the forces which a portable high anchor device may be subjected to, or may be expected to sustain, in actual field use.  
1.6 See Section 6 on Hazards for safety warning.  
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Published
Publication Date
31-Oct-2022
Current Stage
Ref Project

Buy Standard

Standard
ASTM F2684/F2684M-07(2022) - Standard Test Method for Portable High Anchor Devices
English language
3 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation: F2684/F2684M − 07 (Reapproved 2022)
Standard Test Method for
Portable High Anchor Devices
This standard is issued under the fixed designation F2684/F2684M; the number immediately following the designation indicates the year
of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.
A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 2. Referenced Documents
1.1 This test method applies to portable high anchor devices
2.1 ANSI Standard:
that may be used by rescue personnel during both training
Z359.1-2007 American National Standard Safety Require-
exercises and actual rescue operations.
ments for Personal Fall Arrest Systems, Subsystems and
Components
1.2 This test method covers two mechanical tests, the Static
Load Test and the Load Test for Failure.
3. Terminology
1.3 Tests contained herein are destructive in nature. Portable
3.1 Definitions:
high anchor devices subjected to any of these tests shall not be
3.1.1 portable high anchor, n—a manufactured device de-
used in any way after testing except in evaluating the results of
signed to support human loads. Examples include, but are not
such testing.
limited to: davits, A-frames, tripods, quadpods, and cantile-
1.4 The values stated in either SI units or inch-pound units
vered devices.
are to be regarded separately as standard. The values stated in
each system may not be exact equivalents; therefore, each
4. Significance and Use
system shall be used independently of the other. Combining
4.1 Static Load Test—This test verifies that the portable high
values from the two systems may result in nonconformance
anchor device can support the design load without permanent
with the standard.
deformation and continue to function in a safe manner.
1.5 This specification does not imply approval of any
4.2 Load Test for Failure—This test determines the force at
method of use of portable high anchor devices. In addition, the
which the portable high anchor device fails.
tests described are laboratory tests and do not duplicate field
conditions. Furthermore, the test load values contained herein
5. Apparatus
are not to be interpreted as the forces which a portable high
5.1 For both tests, the portable high anchor device shall be
anchor device may be subjected to, or may be expected to
positioned on a flat concrete surface in the manner described by
sustain, in actual field use.
the manufacturer’s instructions for use.
1.6 This standard does not purport to address all of the
5.1.1 Where portable high anchor devices are designed to be
safety concerns, if any, associated with its use. It is the
affixed to a base or structural member that is not part of the
responsibility of the user of this standard to establish appro-
device, the manufacturer shall provide a test base that most
priate safety, health, and environmental practices and deter-
closely resembles the structural element to which the device is
mine the applicability of regulatory limitations prior to use.
designed to be affixed. This test base shall be completely stable
See Section 6 on Hazards for safety warning.
and shall be permitted to be bolted down to prevent movement
1.7 This international standard was developed in accor-
during the test.
dance with internationally recognized principles on standard-
5.1.2 Portable high anchors designed to be attached to
ization established in the Decision on Principles for the
flanged rims of vessel openings would require a test base to
Development of International Standards, Guides and Recom-
simulate the flanged portal to which the device is designed to
mendations issued by the World Trade Organization Technical
be affixed.
Barriers to Trade (TBT) Committee.
5.1.3 Portable high anchors such as beam clamps that are
designed to be attached to a structural element would require a
compatible section of the beam to which the device is designed
This test method is under the jurisdiction of ASTM Committee F32 on Search
to be affixed.
and Rescue and is the direct responsibility of Subcommittee F32.01 on Equipment,
Testing, and Maintenance.
Current edition approved Nov. 1, 2022. Published November 2022. Originally
approved in 2007. Last previous edition approved in 2017 as F2684/F2684M – 07 Available from American National Standards Institute (ANSI), 25 W. 43rd St.,
(2017). DOI: 10.1520/F2684_F2684M-07R22. 4th Floor, New York, NY 10036, http://www.ansi.org.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
F2684/F2684M − 07 (2022)
6. Hazards 8.2.3 The force shall be held for 30 6 1.0 s, and then the
tension shall be completely released over a maximum of 1 min.
6.1 This standard does not purport to address all of the
8.2.4 The force shall be reapplied immediately and shall be
safety concerns, if any, associated with its use. It is the
increased to the same maximum force as previously exerted
responsibility of the user of this standard to establish appro-
and held for 5 min 6 10.0 s before release.
priate safety, health, and environmental practices and deter-
mine the applicability of regulatory limitations prior to use. 8.2.5 At the conclusion of the Static Load Test described in
8.2, the sample portable high anchor device shall be inspected
7. Sampling, Test Specimens, and Test Units to determine pass/fail. A portable high anchor device shall be
considered to fail if any of the following is observed:
7.1 Two samples of each model of portable high anchor
8.2.5.1 If any of the load-bearing members remains de-
device shall be required.
flected by more than 1 % of the length of the member from its
7.1.1 Samples of each model of each portable high anchor
original position.
device shall be selected randomly for te
...