SIGNIFICANCE AND USE
3.1 Saturated fatty acids solidify at a higher temperature than unsaturated fatty acids. This test method provides a means of measuring the solidification temperature of a sample containing both unsaturated and saturated fatty acids by cooling the specimen and measuring the temperature at which solidification occurs.
3.2 Samples containing higher levels of saturated acids will have a higher titer (solidification temperature) than those with lower levels of saturated acids.
3.3 Water present in the sample will raise the titer, so provisions are made in the test method to remove traces of moisture.
SCOPE
1.1 This test method covers the determination of the solidification (titer) point of fatty acids and is applicable to all fatty acids.
1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
General Information
Relations
Standards Content (Sample)
This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation: D1982 − 13 (Reapproved 2022)
Standard Test Method for
Titer of Fatty Acids
This standard is issued under the fixed designation D1982; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 3.2 Samples containing higher levels of saturated acids will
have a higher titer (solidification temperature) than those with
1.1 This test method covers the determination of the solidi-
lower levels of saturated acids.
fication (titer) point of fatty acids and is applicable to all fatty
acids.
3.3 Water present in the sample will raise the titer, so
provisions are made in the test method to remove traces of
1.2 The values stated in SI units are to be regarded as
moisture.
standard. No other units of measurement are included in this
standard.
4. Apparatus
1.3 This standard does not purport to address all of the
safety concerns, if any, associated with its use. It is the 4.1 Beaker, Griffin low-form, 2-L capacity.
responsibility of the user of this standard to establish appro-
4.2 Bottle, wide-mouth, 450-mL capacity, 190-mm height,
priate safety, health, and environmental practices and deter-
inside diameter of neck 40 mm.
mine the applicability of regulatory limitations prior to use.
1.4 This international standard was developed in accor- 4.3 Test Tubes, 100 mm in length, 25 mm in diameter, with
dance with internationally recognized principles on standard-
or without rim. These tubes may have an etched mark
ization established in the Decision on Principles for the extending around the tube at a distance of 57 mm from the
Development of International Standards, Guides and Recom-
bottom to show the height to which the tube is to be filled.
mendations issued by the World Trade Organization Technical
4.4 Stirrer,2mmto3mminoutsidediameter,withoneend
Barriers to Trade (TBT) Committee.
bent in the form of a loop 20 mm in outside diameter. Glass or
stainless steel wire may be used.The upper end can be formed
2. Referenced Documents
toaccommodatehandstirringortobeattachedtoamechanical
2.1 ASTM Standards:
stirrer.
E1Specification for ASTM Liquid-in-Glass Thermometers
4.5 Laboratory Thermometer, having a range from 0°C to
2.2 AOCS Standard:
150°C.
Specification H6-40
4.6 Titer Test Thermometer—An ASTM Titer Test Ther-
3. Significance and Use
mometer having a range from −2 °C to +68°C and conform-
3.1 Saturated fatty acids solidify at a higher temperature
ing to the requirements for Thermometer 36C as prescribed in
thanunsaturatedfattyacids.Thistestmethodprovidesameans
Specification E1. Thermometric devices such as RTDs, therm-
of measuring the solidification temperature of a sample con-
istors and liquid-in-glass thermometers of equal or better
taining both unsaturated and saturated fatty acids by cooling
accuracy in the specified temperature range, may be used.
the specimen and measuring the temperature at which solidi-
NOTE 1—Thermometers conforming to the requirements for theAOCS
fication occurs.
Titer Thermometer (AOCS Specification H6-40) meet these require-
ments.
This test method is under the jurisdiction of ASTM Committee D01 on Paint
and Related Coatings, Materials, andApplications and is the direct responsibility of
5. Procedure
Subcommittee D01.34 on Pine Chemicals and Hydrocarbon Resins.
Current edition approved Dec. 1, 2022. Published December 2
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.