ASTM C728-97
(Specification)Standard Specification for Perlite Thermal Insulation Board
Standard Specification for Perlite Thermal Insulation Board
SCOPE
1.1 This specification covers the composition and physical properties for perlite thermal insulation board used principally above structural roof decks and as a base for built-up, modified, and elastomeric membrane roofing in building construction.
1.2 The use of thermal insulation materials covered by this specification may be regulated by building codes or other agencies that address fire performance, or both. The fire performance of the material should be addressed through standard fire test methods established by the appropriate governing documents.
1.3 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.
1.4 The following safety hazards caveat pertains only to the test methods, Section , in this specification:This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or discontinued.
Contact ASTM International (www.astm.org) for the latest information.
Designation: C 728 – 97
Standard Specification for
1
Perlite Thermal Insulation Board
This standard is issued under the fixed designation C 728; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
2
1. Scope Thermal Insulation Lots
C 518 Test Method for Steady-State Heat Flux Measure-
1.1 This specification covers the composition and physical
ments and Thermal Transmission Properties by Means of
properties for perlite thermal insulation board used principally
2
the Heat Flow Meter Apparatus
above structural roof decks and as a base for built-up, modified,
C 1289 Specification for Faced Rigid Cellular Polyisocya-
and elastomeric membrane roofing in building construction.
2
nurate Thermal Insulation Board
1.2 The use of thermal insulation materials covered by this
E 84 Test Method for Surface Burning Characteristics of
specification may be regulated by building codes or other
3
Building Materials
agencies that address fire performance, or both. The fire
performance of the material should be addressed through
3. Terminology
standard fire test methods established by the appropriate
3.1 For complete descriptions of terms used in this specifi-
governing documents.
cation, refer to Terminology C 168.
1.3 The values stated in inch-pound units are to be regarded
as the standard. The values given in parentheses are for
4. Classification
information only.
4.1 Perlite thermal insulation board is classified as follows:
1.4 The following safety hazards caveat pertains only to the
1
4.1.1 Type 1, Roof Insulation Board—The ⁄2 in. (13 mm)
test methods, Section 11, in this specification: This standard
thick version of this product is available only to manufacturers
does not purport to address all of the safety concerns, if any,
of laminated rigid foam products as specified in Specification
associated with its use. It is the responsibility of the user of this
C 1289.
standard to establish appropriate safety and health practices
4.1.2 Type 2, Roof Cover/Recover Board—This is used
and determine the applicability of regulatory limitations prior
primarily as a field-applied cover board over other roof
to use.
insulations or in reroofing applications.
2. Referenced Documents
5. Ordering Information
2.1 The following standards, of the issue in effect on the
5.1 Orders shall at least include the following information:
date of material purchase, form a part of this specification to
5.1.1 Title and designation Specification C 728.
the extent specified herein:
5.1.2 Product name, nominal thickness and dimensions.
2.2 ASTM Standards:
5.1.3 Quantity of material ordered.
C 165 Test Method for Measuring Compressive Properties
2 5.1.4 Manufacturer’s name, address, and telephone number.
of Thermal Insulations
C 168 Terminology Relating to Thermal Insulating Materi-
6. Materials and Manufacture
2
als
6.1 Composition—The basic material of the insulation
C 177 Test Method for Steady-State Heat Flux Measure-
board shall be perlite expanded by the application of heat to
ments and Thermal Transmission Properties by Means of
form glassy, cellular aggregates. The insulation board shall be
2
the Guarded-Hot-Plate Apparatus
composed of expanded perlite and fibers formed into rigid, flat,
C 203 Test Methods for Breaking Load and Flexural Prop-
rectangular units with a suitable sizing material incorporated in
2
erties of Block-Type Thermal Insulation
the product. It may have on one or both surfaces a facing or
2
C 209 Test Methods for Cellulosic Fiber Insulating Board
coating to prevent excessive hot bitumen strike-in during
C 390 Criteria for Sampling and Acceptance of Preformed
roofing installation.
6.2 Lamination—The finished board may be either single-
1
This specification is under the jurisdiction of ASTM Committee C-16 on
ply or multiple-ply. When multiple-ply boards are supplied, a
Thermal Insulation and is the direct responsibility of Subcommittee C16.22 on
suitable adhesive shall be used to join the plies.
Organic and Nonhomogeneous Inorganic Thermal Insulations.
Current edition approved May 10, 1997. Published August 1997. Originally
published as C 728 – 72. Last previous edition C 728 – 91.
2 3
Annual Book of ASTM Standards, Vol 04.06. Annual Book of ASTM Standards, Vol 04.07.
Copyright © ASTM, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
C 728
7. Physical Properties 10. Sampling
7.1 Thermal Resistance—Perlite thermal insulation boards 10.1 Unless otherwise specified, sampling for qualification
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.