Standard Specification for Faced Rigid Cellular Polyisocyanurate Thermal Insulation Board

SCOPE
1.1 This specification covers the general requirements for faced thermal insulation boards composed of rigid cellular polyisocyanurate surfaced with other materials. The insulation boards are intended for use at temperatures between -40 and 200oF (40 and 93oC). This specification does not cover cryogenic applications. Consult the manufacturer for specific recommendations and properties in cryogenic conditions. For specific applications, the actual temperature limits shall be agreed upon by the manufacturer and the purchaser.
1.2 This standard is intended to apply to rigid cellular polyurethane-modified polyisocyanurate thermal insulation board products that are commercially acceptable as non-structural panels useful in building construction. The term polyisocyanurate encompasses the term polyurethane. For engineering and design purposes, users should follow specific product information provided by board manufacturers regarding physical properties, system design considerations and installation recommendations.
1.3 The use of thermal insulation materials covered by this specification may be regulated by building codes, or other agencies that address fire performance, or both. The fire performance of the material should be addressed through standard fire test methods established by the appropriate governing documents.
1.4 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only and may be approximate. For conversion to metric units other than those contained in this standard, refer to IEEE/ASTM SI 10.
1.5 The following safety hazards caveat pertains only to the test methods, Section 11, in this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
09-Jun-2002
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM C1289-02 - Standard Specification for Faced Rigid Cellular Polyisocyanurate Thermal Insulation Board
English language
8 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superceded and replaced by a new version or discontinued.
Contact ASTM International (www.astm.org) for the latest information.
Designation: C 1289 – 02
Standard Specification for
Faced Rigid Cellular Polyisocyanurate Thermal Insulation
1
Board
This standard is issued under the fixed designation C 1289; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope 2. Referenced Documents
1.1 This specification covers the general requirements for 2.1 The following documents, of the issue in effect on the
faced thermal insulation boards composed of rigid cellular date of material purchase, form a part of this specification to
polyisocyanurate surfaced with other materials. The insulation the extent specified herein:
boards are intended for use at temperatures between −40 and 2.2 ASTM Standards:
200°F (−40 and 93°C). This specification does not cover C 168 Terminology Relating to Thermal Insulating Materi-
2
cryogenic applications. Consult the manufacturer for specific als
recommendations and properties in cryogenic conditions. For C 177 Test Method for Steady-State Heat Flux Measure-
specific applications, the actual temperature limits shall be ments and Thermal Transmission Properties by Means of
2
agreed upon by the manufacturer and the purchaser. the Guarded-Hot-Plate Apparatus
1.2 This standard is intended to apply to rigid cellular C 203 Test Methods for Breaking Load and Flexural Prop-
2
polyurethane-modified polyisocyanurate thermal insulation erties of Block Type Thermal Insulation
2
board products that are commercially acceptable as non- C 208 Specification for Cellulosic Fiber Insulating Board
2
structural panels useful in building construction. The term C 209 Test Methods for Cellulosic Fiber Insulating Board
polyisocyanurate encompasses the term polyurethane. For C 303 Test Method for Density of Preformed Block-Type
2
engineering and design purposes, users should follow specific Thermal Insulation
product information provided by board manufacturers regard- C 390 Criteria for Sampling and Acceptance of Preformed
2
ing physical properties, system design considerations and Thermal Insulation Lots
installation recommendations. C 518 Test Method for Steady-State Heat Flux Measure-
1.3 The use of thermal insulation materials covered by this ments and Thermal Transmission Properties by Means of
2
specification may be regulated by building codes, or other the Heat Flow Meter Apparatus
agencies that address fire performance, or both. The fire C 550 Test Method for Measuring Trueness and Squareness
2
performance of the material should be addressed through of Rigid Block Thermal Insulation
2
standard fire test methods established by the appropriate C 728 Specification for Perlite Thermal Insulation Board
governing documents. C 1045 Practice for Calculating Thermal Transmission
2
1.4 The values stated in inch-pound units are to be regarded Properties from Steady-State Heat Flux Measurements
as the standard. The values given in parentheses are for C 1058 Practice for Selecting Temperatures for Evaluating
2
information only and may be approximate. For conversion to and Reporting Thermal Properties of Thermal Insulation
metric units other than those contained in this standard, refer to C 1114 Test Method for Steady-State Thermal Transmission
2
IEEE/ASTM SI 10. Properties by Means of the Thin-Heater Apparatus
1.5 The following safety hazards caveat pertains only to the C 1303 Test Method for Estimating the Long-Term Change
test methods, Section 11, in this specification. This standard in the Thermal Resistance of Unfaced Rigid Closed Cell
does not purport to address all of the safety concerns, if any, Plastic Foams by Slicing and Scaling Under Controlled
2
associated with its use. It is the responsibility of the user of this Laboratory Conditions
standard to establish appropriate safety and health practices C 1363 Test Method for Thermal Performance of Building
2
and determine the applicability of regulatory limitations prior Assemblies by Means of a Hot Box Apparatus
to use. D 226 Specification for Asphalt-Saturated Organic Felt
3
Used in Roofing and Waterproofing
1
This specification is under the jurisdiction of ASTM Committee C16 on
Thermal Insulation and is the direct responsibility of Subcommittee C16.22 on
Organic and Nonhomogeneous Inorganic Thermal Insulations.
2
Current edition approved June 10, 2002. Published July 2002. Originally Annual Book of ASTM Standards, Vol 04.06.
3
published as C 1289 – 95. Last previous edition C 1289 – 01. Annual Book of ASTM Standards, Vol 04.04.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ------------
...

Questions, Comments and Discussion