This specification covers the composition and physical properties of spray-applied cellulosic fiber stabilized thermal insulation applied to open or closed ceiling spaces, regardless of slope. The basic material shall be recycled cellulosic fiber made from selected paper or paperboard stock. Stabilized cellulosic fiber thermal insulation is produced by the addition of adhesive(s) to loose-fill cellulosic fiber insulation. Additives are introduced to provide properties such as flame resistance, processing and handling characteristics. An adhesive is added to the insulation product to resist long-term settling of the insulation after installation and curing. Different test methods shall be performed in order to determine the following properties of thermal insulation: density, corrosiveness, critical radiant flux, fungi resistance, water vapor sorption, odor emission, smoldering combustion, thermal resistance, flame resistance permanency, shrinkage, and settling.
SCOPE
1.1 This specification covers the composition and physical properties of spray-applied cellulosic fiber stabilized thermal insulation applied to open or closed ceiling spaces, regardless of slope, where temperatures range from -49 to 194°F (-45 to 90°C).
1.2 Stabilized cellulosic fiber thermal insulation is produced by the addition of adhesive(s) to loose-fill cellulosic fiber insulation. The adhesive(s) may be added to the insulation at time of manufacture and, if necessary, activated by the addition of water when installed or the adhesive may be added to the insulation at the time of installation.
1.3 This is a material specification that is not intended to deal with methods of application that are supplied by the manufacturer.
1.4 The values stated in inch-pound units are to be regarded as standard. The SI units given in parentheses are for information only.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Buy Standard
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:C1497 −12
StandardSpecification for
1
Cellulosic Fiber Stabilized Thermal Insulation
This standard is issued under the fixed designation C1497; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope C739Specification for Cellulosic Fiber Loose-Fill Thermal
Insulation
1.1 This specification covers the composition and physical
C1149Specification for Self-Supported Spray Applied Cel-
properties of spray-applied cellulosic fiber stabilized thermal
lulosic Thermal Insulation
insulation applied to open or closed ceiling spaces, regardless
C1304Test Method for Assessing the Odor Emission of
of slope, where temperatures range from -49 to 194°F (-45 to
Thermal Insulation Materials
90°C).
C1338Test Method for Determining Fungi Resistance of
1.2 Stabilizedcellulosicfiberthermalinsulationisproduced
Insulation Materials and Facings
by the addition of adhesive(s) to loose-fill cellulosic fiber
E691Practice for Conducting an Interlaboratory Study to
insulation. The adhesive(s) may be added to the insulation at
Determine the Precision of a Test Method
timeofmanufactureand,ifnecessary,activatedbytheaddition
E970TestMethodforCriticalRadiantFluxofExposedAttic
of water when installed or the adhesive may be added to the
Floor Insulation Using a Radiant Heat Energy Source
insulation at the time of installation.
3. Terminology
1.3 This is a material specification that is not intended to
3.1 Definitions—For definitions of terms used in this
deal with methods of application that are supplied by the
specification, see Terminology C168.
manufacturer.
3.2 Definitions of Terms Specific to This Standard:
1.4 The values stated in inch-pound units are to be regarded
3.2.1 shrinkage—decrease in thickness that occurs from the
as standard. The SI units given in parentheses are for informa-
time of installation until the insulation achieves a stable
tion only.
moisture content.
1.5 This standard does not purport to address all of the
3.2.2 stabilized cellulose—a cellulosic insulation product
safety concerns, if any, associated with its use. It is the
treated to resist, after drying, further settling of no more than
responsibility of the user of this standard to establish appro-
5%.
priate safety and health practices and determine the applica-
bility of regulatory limitations prior to use.
4. Materials and Manufacture
4.1 The basic material shall be recycled cellulosic fiber
2. Referenced Documents
made from selected paper or paperboard stock. Additives are
2
2.1 ASTM Standards:
introduced to provide properties such as flame resistance,
C167Test Methods forThickness and Density of Blanket or
processing and handling characteristics. An adhesive is added
Batt Thermal Insulations
to the insulation product to resist long-term settling of the
C168Terminology Relating to Thermal Insulation
insulation after installation and curing.
C177Test Method for Steady-State Heat Flux Measure-
4.2 The materials are processed into a form suitable for
ments and Thermal Transmission Properties by Means of
installation by a pneumatic method.
the Guarded-Hot-Plate Apparatus
4.3 Theadhesivemaybeaddedtotheproductatthetimeof
manufacture or at the time of installation by means of a liquid
1 spray.
This specification is under the jurisdiction of ASTM Committee C16 on
Thermal Insulation and is the direct responsibility of Subcommittee C16.23 on
5. Physical and Chemical Properties
Blanket and Loose Fill Insulation.
Current edition approved Sept. 1, 2012. Published November 2012. Originally
5.1 Density—The density of conditioned stabilized insula-
approved in 2001. Last previous edition approved in 2004 as C149704. DOI:
3 3
tion in lb/ft (kg/m ) shall be determined in accordance with
10.1520/C1497-12.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or Section 7.
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
5.2 Corrosiveness—The loose-fill insulation material shall
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website. be tested for corrosiveness in accordance with Section 8. The
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
C1497−12
composition of the insulation material shall be such that after 7.1.1 Scope—This test method provides a basis for calcu-
testing, no perforation of the 0.003 in. (0.076 mm) metal lating the product coverage values and for conducting physical
specimens shall be evident when the specimens are observed property tests requirin
...
This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: C1497 − 04 C1497 − 12
Standard Specification for
1
Cellulosic Fiber Stabilized Thermal Insulation
This standard is issued under the fixed designation C1497; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 This specification covers the composition and physical properties of spray-applied cellulosic fiber stabilized thermal
insulation applied to open or closed ceiling spaces, regardless of slope, where temperatures range from -49 to 194°F (-45 to 90°C).
1.2 Stabilized cellulosic fiber thermal insulation is produced by the addition of adhesive(s) to loose-fill cellulosic fiber
insulation. The adhesive(s) may be added to the insulation at time of manufacture and, if necessary, activated by the addition of
water when installed or the adhesive may be added to the insulation at the time of installation.
1.3 This is a material specification that is not intended to deal with methods of application that are supplied by the manufacturer.
1.4 The values stated in inch-pound units are to be regarded as standard. The SI units given in parentheses are for information
only.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory
limitations prior to use.
2. Referenced Documents
2
2.1 ASTM Standards:
C167 Test Methods for Thickness and Density of Blanket or Batt Thermal Insulations
C168 Terminology Relating to Thermal Insulation
C177 Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the
Guarded-Hot-Plate Apparatus
C739 Specification for Cellulosic Fiber Loose-Fill Thermal Insulation
C1149 Specification for Self-Supported Spray Applied Cellulosic Thermal Insulation
C1304 Test Method for Assessing the Odor Emission of Thermal Insulation Materials
C1338 Test Method for Determining Fungi Resistance of Insulation Materials and Facings
E691 Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method
E970 Test Method for Critical Radiant Flux of Exposed Attic Floor Insulation Using a Radiant Heat Energy Source
3. Terminology
3.1 Definitions—For definitions of terms used in this specification, see Terminology C168.
3.2 Definitions of Terms Specific to This Standard:
3.2.1 shrinkage—decrease in thickness that occurs from the time of installation until the insulation achieves a stable moisture
content.
3.2.2 stabilized cellulose—a cellulosic insulation product treated to resist, after drying, further settling of no more than 5 %.
4. Materials and Manufacture
4.1 The basic material shall be recycled cellulosic fiber made from selected paper or paperboard stock. Additives are introduced
to provide properties such as flame resistance, processing and handling characteristics. An adhesive is added to the insulation
product to resist long-term settling of the insulation after installation and curing.
1
This specification is under the jurisdiction of ASTM Committee C16 on Thermal Insulation and is the direct responsibility of Subcommittee C16.23 on Blanket and Loose
Fill Insulation.
Current edition approved April 1, 2004Sept. 1, 2012. Published May 2004November 2012. Originally approved in 2001. Last previous edition approved in 20012004 as
ε1
C1497–0104. . DOI: 10.1520/C1497-04.10.1520/C1497-12.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
C1497 − 12
4.2 The materials are processed into a form suitable for installation by a pneumatic method.
4.3 The adhesive may be added to the product at the time of manufacture or at the time of installation by means of a liquid spray.
5. Physical and Chemical Properties
3 3
5.1 Density—The density of conditioned stabilized insulation in lb/ft (kg/m ) shall be determined in accordance with Section
7.
5.2 Corrosiveness—The loose-fill insulation material shall be te
...