ASTM C923M-98
(Specification)Standard Specification for Resilient Connectors Between Reinforced Concrete Manhole Structures, Pipes, and Laterals (Metric)
Standard Specification for Resilient Connectors Between Reinforced Concrete Manhole Structures, Pipes, and Laterals (Metric)
SCOPE
1.1 This specification covers the minimum performance and material requirements for resilient connectors used for connections between precast reinforced concrete manholes conforming to Specification C478 and pipes, and between precast reinforced concrete pipe and laterals.
1.1.1 These connectors are designed to minimize leakage between the pipe and manhole, and between the pipe and lateral.
1.2 This specification is the metric counterpart of Specification C 923. Note 1-This specification covers the design, material, and performance of the resilient connection only. Connections covered by this specification are adequate for hydrostatic pressures up to 70 kPa (7.1 m) without leakage when tested in accordance with Section 7. Infiltration or exfiltration quantities for an installed system are dependent upon many factors other than the connections between manhole structures and pipe, and allowable quantities must be covered by other specifications and suitable testing of the installed pipeline and system.
1.3 The following precautionary caveat pertains only to the test methods portion, Section 7, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For a specific precaution statement, see 7.2.5.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or
withdrawn. Contact ASTM International (www.astm.org) for the latest information.
Designation: C 923M – 98
METRIC
AMERICAN SOCIETY FOR TESTING AND MATERIALS
100 Barr Harbor Dr., West Conshohocken, PA 19428
Reprinted from the Annual Book of ASTM Standards. Copyright ASTM
Standard Specification for
Resilient Connectors Between Reinforced Concrete Manhole
1
Structures, Pipes, and Laterals [Metric]
This standard is issued under the fixed designation C 923M; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope C 822 Terminology Relating to Concrete Pipe and Related
3
Products
1.1 This specification covers the minimum performance and
D 395 Test Methods for Rubber Property—Compression
material requirements for resilient connectors used for connec-
4
Set
tions between precast reinforced concrete manholes conform-
D 412 Test Methods for Vulcanized Rubber and Thermo-
ing to Specification C 478 and pipes, and between precast
4
plastic Rubbers and Thermoplastic Elastomers—Tension
reinforced concrete pipe and laterals.
D 471 Test Method for Rubber Property—Effect of Liq-
1.1.1 These connectors are designed to minimize leakage
4
uids
between the pipe and manhole, and between the pipe and
D 543 Test Method for Resistance of Plastics to Chemical
lateral.
5
Reagents
1.2 This specification is the metric counterpart of Specifi-
D 573 Test Method for Rubber—Deterioration in an Air
cation C 923.
4
Oven
NOTE 1—This specification covers the design, material, and perfor-
D 624 Test Method for Tear Strength of Conventional
mance of the resilient connection only. Connections covered by this
4
Vulcanized Rubber and Thermoplastic Elastomer
specification are adequate for hydrostatic pressures up to 70 kPa (7.1 m)
D 746 Test Method for Brittleness Temperature of Plastics
without leakage when tested in accordance with Section 7. Infiltration or
5
and Elastomers by Impact
exfiltration quantities for an installed system are dependent upon many
5
factors other than the connections between manhole structures and pipe, D 883 Terminology Relating to Plastics
and allowable quantities must be covered by other specifications and
D 1171 Test Method for Rubber Deterioration—Surface
suitable testing of the installed pipeline and system.
Ozone Cracking Outdoors or Chamber (Triangular Speci-
4
mens)
1.3 The following precautionary caveat pertains only to the
4
D 1566 Terminology Relating to Rubber
test methods portion, Section 7, of this specification: This
D 2240 Test Method for Rubber Property—Durometer
standard does not purport to address all of the safety concerns,
4
Hardness
if any, associated with its use. It is the responsibility of the user
of this standard to establish appropriate safety and health
3. Terminology
practices and determine the applicability of regulatory limita-
3.1 Definitions:
tions prior to use. For a specific precaution statement, see
3.1.1 Terms relating to plastics and rubber shall be as
7.2.5.
defined in Terminologies D 883 and D 1566, respectively.
2. Referenced Documents
3.1.2 Terms relating to precast concrete pipe, manholes, and
related products shall be as defined in Terminology C 822 and
2.1 ASTM Standards:
as modified in 3.1.3-3.1.6.
A 167 Specification for Stainless and Heat–Resisting
2
3.1.3 connector—the entire assembly including resilient
Chromium—Nickel Steel Plate, Sheet, and Stripe
seals and metallic or nonmetallic mechanical devices, if any,
C 478 Specification for Precast Reinforced Concrete Man-
3
used therein.
hole Sections
3.1.4 lateral—the small diameter pipe connected to the
main line.
1 3.1.5 pipe—the inlet or outlet pipe connected to the man-
This specification is under the jurisdiction of ASTM Committee C-13 on
hole.
Concrete Pipe and is the direct responsibility of Subcommittee C13.06 on Manholes
and Specials.
Current edition approved July 10, 1998. Published March 1999.
Originally published as C 923M – 80. Last previous edition C 923M – 96.
2 4
Annual Book of ASTM Standards, Vol 01.03. Annual Book of ASTM Standards, Vol 09.01.
3 5
Annual Book of ASTM Standards, Vol 04.05. Annual Book of ASTM Standards, Vol 08.01.
1
---------------------- Page: 1 ----------------------
NOTICE:¬This¬standard¬has¬either¬been¬superseded¬and¬replaced¬by¬a¬new¬version¬or
discontinued.¬Contact¬ASTM¬International¬(www.astm.org)¬for¬the¬latest¬information.¬
C 923M
3.1.6 pipe stub—a capped or plugged pipe, or section of under the performance conditions in accordance with Section
pipe, installed in a manhole to allow for future connections. 7. Devices used to effect mechanical seals shall conform to the
requirements specified in Section 4.
4. Materials and Manufacture
5.2 For lateral to pipe connectors, t
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.