EN 13126-5:2011
(Main)Building hardware - Hardware for windows and door height windows - Requirements and test methods - Part 5: Devices that restrict the opening of windows and door height windows
Building hardware - Hardware for windows and door height windows - Requirements and test methods - Part 5: Devices that restrict the opening of windows and door height windows
This part of EN 13126 specifies requirements and test methods for durability, strength, security and functionality of devices that restrict the opening of windows and door height windows.
NOTE 1 Restrictors and reverse restrictors can be either a separate item of hardware or an integral part of hardware, for example a part of the operating gear or an integral part of a hinge.
NOTE 2 Windows may be fitted with more than one restrictor.
NOTE 3 The requirements included within this standard take the needs for child safety into consideration, child protective window restrictors intended to be installed by the end consumers are beyond the scope of this standard. Therefore for the DIY market refer to PC398.
Baubeschläge - Beschläge für Fenster und Fenstertüren - Anforderungen und Prüfverfahren - Teil 5: Vorrichtungen zur Begrenzung des Öffnungswinkels von Fenstern
Der vorliegende Teil von EN 13126 legt die Anforderungen an und Prüfverfahren für die Dauerfunktions-tüchtigkeit, Festigkeit, Schutzwirkung und Funktionsweise von Vorrichtungen zur Begrenzung des Öffnungs-winkels von Fenstern und Fenstertüren fest.
ANMERKUNG 1 Begrenzer und Rückstellbegrenzer können sowohl ein einzelnes Beschlagselement als auch ein integraler Teil der Beschläge, wie z.B. ein Teil der Betätigungsvorrichtung oder ein eingebauter Teil eines Türbands sein.
ANMERKUNG 2 Fenster können mit mehr als einem Begrenzer ausgerüstet sein.
ANMERKUNG 3 Die in der vorliegenden Norm enthaltenen Anforderungen berücksichtigen die Erfordernisse der Sicher¬heit von Kindern; für den Einbau durch den Endverbraucher vorgesehene Öffnungsbegrenzer für Fenster, die dem Kinderschutz dienen, sind in der vorliegenden Norm nicht enthalten. Für die Angebote von Baumärkten wird auf PC398 und prEN 16281 verwiesen.
Quincaillerie pour le bâtiment - Exigences et méthodes d'essai des ferrures de fenêtres et portes-fenêtres - Partie 5: Dispositifs limiteurs d’ouverture des fenêtres et portes-fenêtres
La présente partie du prEN 13126 spécifie les exigences et les méthodes d’essai relatives à l’endurance, à la résistance, à la sécurité des biens et aux fonctionnalités des dispositifs limiteurs d’ouverture des fenêtres et des portes-fenêtres.
NOTE 1 Les limiteurs et les limiteurs réversibles peuvent soit être des éléments individuels de quincaillerie, soit faire partie intégrante de la quincaillerie, par exemple une partie du mécanisme de manoeuvre ou une partie intégrante de la paumelle.
NOTE 2 Les fenêtres peuvent être munies de plusieurs limiteurs.
NOTE 3 Les exigences incluses dans la présente norme tiennent compte des besoins liés à la sécurité des enfants ; les limiteurs de fenêtre de sécurité pour enfant destinés à être installés par le consommateur final sont en dehors du domaine d’application de la présente norme. Par conséquent, pour le marché DIY faire référence au PC 398 et au prEN 16281.
Stavbno okovje - Okovje za okna in zastekljena vrata - Zahteve in preskusne metode - 5. del: Naprave, ki preprečujejo odpiranje oken in zastekljenih vrat
Ta del EN 13126 opredeljuje zahteve in preskusne postopke za trajnost, trdnost, varnost in funkcionalnost naprav, ki preprečujejo odpiranje oken in zastekljenih vrat.
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Baubeschläge - Beschläge für Fenster und Fenstertüren - Anforderungen und Prüfverfahren - Teil 5: Vorrichtungen zur Begrenzung des Öffnungswinkels von FensternQuincaillerie pour le bâtiment - Exigences et méthodes d'essai des ferrures de fenêtres et portes-fenêtres - Partie 5: Dispositifs limiteurs d’ouverture des fenêtres et portes-fenêtresBuilding hardware - Hardware for windows and door height windows - Requirements and test methods - Part 5: Devices that restrict the opening of windows and door height windows91.190Stavbna opremaBuilding accessoriesICS:Ta slovenski standard je istoveten z:EN 13126-5:2011SIST EN 13126-5:2012en,fr,de01-januar-2012SIST EN 13126-5:2012SLOVENSKI
STANDARDSIST-TS CEN/TS 13126-5:20051DGRPHãþD
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 13126-5
November 2011 ICS 91.190 Supersedes CEN/TS 13126-5:2004English Version
Building hardware - Hardware for windows and door height windows - Requirements and test methods - Part 5: Devices that restrict the opening of windows and door height windows
Quincaillerie pour le bâtiment - Exigences et méthodes d'essai des ferrures de fenêtres et portes-fenêtres - Partie 5: Dispositifs limiteurs d'ouverture des fenêtres et portes-fenêtres
Baubeschläge - Beschläge für Fenster und Fenstertüren - Anforderungen und Prüfverfahren - Teil 5: Vorrichtungen zur Begrenzung des Öffnungswinkels von Fenstern This European Standard was approved by CEN on 15 October 2011.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2011 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 13126-5:2011: ESIST EN 13126-5:2012
Test equipment . 18Annex B (normative)
Test flow chart . 22Bibliography . 23 SIST EN 13126-5:2012
Clause 3, Terms and definitions: Child safety restrictor added in 3.5; Clause 4, Classification: additional grades added in 4.6 (Safety in use); additional grades added in 4.9 (Application); table with test sizes added in 4.10 (Test sizes); example of classification added in 4.11; Clause 5, Requirements: requirements in whole Clause 5 have been completely revised; Clause 7, Test methods: test methods in whole Clause 7 have been completely revised; SIST EN 13126-5:2012
3.2 holding restrictor (including peg type casement stays) mechanical device which is intended to hold the active sash in a predetermined position
3.3 reverse restrictor mechanical device which holds a reversed active sash securely for cleaning 3.4 safety restrictor robust mechanical device intended to limit the initial movement of an active sash in a predetermined position, maximum 100 mm, to prevent accidental passage through the window SIST EN 13126-5:2012
Grades shall be in accordance with EN 13126-1. 4.6 Safety in use (5 – fifth digit) One grade shall be id
...