Inlet valves for flushing cisterns with internal overflow

The purpose of this document is to specify:
- the dimensional, hygiene, tightness, pressure performance, hydraulic, acoustic, mechanical and physico chemical characteristics which inlet valves for flushing cisterns shall comply with;
- the test methods for  testing these characteristics;
- marking and presentation.
This document applies exclusively to the valve itself and it does not prejudge compliance with health regulations as the inlet valve is being fitted into the cistern.
This document does not cover valves intended to equip flushing cisterns with external overflow.
This document applies to valves such as float valves limit operating at pressures up to NP 10 (whose operating range is from 0,05 MPa to 1 MPa - 0,5 bar to 10 bar) designed to supply cold water to flushing cisterns for use with WC pans, that are permanently connected to a potable water supply system.
The working range can be extended downwards (< 0,05 MPa - 0,5 bar) down to 0,01 MPa (0,1 bar), in which case the manufacturer's instructions shall indicate this possibility as well as the recommended working range.

Füllventile für Spülkästen mit integriertem Überlauf

Diese Europäische Norm dient der Festlegung von:
¾   Anforderungen an Maße, Hygiene, Dichtheit, Druckbeständigkeit, hydraulischer Eigenschaften, Geräuschverhalten, mechanischer Festigkeit und physikalisch-chemischer Eigenschaften, denen die Füllventile für Spülkästen entsprechen müssen;
¾   Prüfverfahren zum Nachweis dieser Anforderungen;
¾   Anforderung an Kennzeichnung und Darstellung.
Diese Norm gilt ausschließlich für das Füllventil selbst und beinhaltet nicht die Einhaltung von Gesundheits-vorschriften, da das Füllventil in den Spülkasten eingebaut wird.
Füllventile zum Einbau in Spülkästen mit externem Überlauf werden in dieser Norm nicht behandelt.
Diese Norm gilt für Füllventile für einen maximalen Betriebsdruck DN 10 (deren Funktionsbereich von 0,05 MPa bis 1 MPa - von 0,5 bar bis 10 bar - reicht) zur Kaltwasserversorgung von Spülkästen für WC Becken, die ständig an die Trinkwasserinstallation angeschlossen sind.
Füllventile können einen erweiterten Funktionsbereich unterhalb 0,05 MPa (0,5 bar) bis 0,01 MPa (0,1 bar) aufweisen. In diesem Fall muss die Herstelleranweisung diese Möglichkeit sowie den empfohlenen Funktionsbereich angeben.
Diese Norm gilt nicht für Füllventile für andere Anwendungsbereiche, z. B. für den Einbau in Pumpen- und Nachspeisebehälter

Robinet pour remplissage de réservoir de chasse avec trop-plein intérieur

Le présent document a pour objet de fixer :
-   les caractéristiques dimensionnelles, d'hygiène, d'étanchéité, de tenue en pression, hydrauliques, acoustiques, mécaniques, physico-chimiques auxquelles doivent répondre les robinets pour réservoir de chasse ;
-   la technique des essais ;
-   le marquage et la présentation.
Le présent document s'applique exclusivement au robinet lui-même, et ne préjuge pas de la conformité aux réglementations sanitaires du robinet installé dans le réservoir de chasse.
Les robinets destinés à équiper les réservoirs à trop-plein extérieur ne sont pas traités dans le présent document.
Il s'applique aux robinets de remplissage de PN 10, dont la plage de fonctionnement est de 0,05 MPa à 1 MPa (0,5 bar à 10 bar), destinés à l'alimentation en eau froide des réservoirs de chasse équipant les cuvettes de WC raccordés de façon permanente au réseau d'eau potable.
La plage de fonctionnement peut être étendue vers le bas en-dessous de 0,05 MPa (0,5 bar) jusqu'à 0,01 MPa (0,1 bar) ; dans ce cas, la notice du fabricant devra indiquer cette possibilité ainsi que la plage de fonctionnement recommandée.

Inlet valves for flushing cisterns with internal overflow

General Information

Status
Published
Publication Date
31-Aug-2004
Current Stage
9020 - Submission to 2 Year Review Enquiry - Review Enquiry
Start Date
15-Jul-2024
Completion Date
15-Jul-2024

Buy Standard

Standard
EN 14124:2004
English language
21 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Inlet valves for flushing cisterns with internal overflowFüllventile für Spülkästen mit integriertem ÜberlaufRobinet pour remplissage de réservoir de chasse avec trop-plein intérieurInlet valves for flushing cisterns with internal overflow91.140.70Sanitarne napraveSanitary installationsICS:Ta slovenski standard je istoveten z:EN 14124:2004SIST EN 14124:2004en01-oktober-2004SIST EN 14124:2004SLOVENSKI
STANDARD
EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 14124September 2004ICS 91.140.70 English versionInlet valves for flushing cisterns with internal overflowRobinet pour remplissage de réservoir de chasse avectrop-plein intérieurFüllventile für Spülkästen mit integriertem ÜberlaufThis European Standard was approved by CEN on 9 July 2004.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Central Secretariat or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia,Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2004 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 14124:2004: ESIST EN 14124:2004

Test method used to verify the acoustic characteristics.21
testing these characteristics;  marking and presentation. This document applies exclusively to the valve itself and it does not prejudge compliance with health regulations as the inlet valve is being fitted into the cistern. This document does not cover valves intended to equip flushing cisterns with external overflow. This document applies to valves such as float valves limit operating at pressures up to NP 10 (whose operating range is from 0,05 MPa to 1 MPa – 0,5 bar to 10 bar) designed to supply cold water to flushing cisterns for use with WC pans, that are permanently connected to a potable water supply system. The working range can be extended downwards (< 0,05 MPa – 0,5 bar) down to 0,01 MPa (0,1 bar), in which case the manufacturer’s instructions shall indicate this possibility as well as the recommended working range.
Range which shall be covered
Optional range This document does not apply to valves used for other applications: pumping tanks, storage tanks, etc. Table 1 — Working conditions for flushing cistern inlet valves
Operating limits Limit recommended for proper functioning (dynamic pressure) Minimum dynamic pressure P ≥ 0,05 MPa (0,5 bar) a 0,1 MPa ≤ P ≤ 0,5 Mpa (1 bar ≤ P ≤ 5 bar) Maximum static pressure P ≤ 1 MPa (10 bar)
a According to
the manufacturer’s indication, the dynamic pressure (opening-closing) can be lowered. SIST EN 14124:2004
...