Aerospace series - Cables, electrical, aircraft use - Test methods - Part 605: Wet short circuit test

This standard specifies a method for appraising the behaviour of cable insulation subjected to an electric arc initiated and maintained by a contaminating fluid.
This standard shall be used together with EN 3475-100.
The primary aim of this test is:
-   to produce, in a controlled fashion, continuous failure effects which are representative of those which may occur in service when a typical cable bundle is damaged and subjected to aqueous fluid contamination such that electrical arcing occurs, between cables; and
-   to examine the aptitude of the insulation to track, to propagate electric arc  to the electrical origin.
Originally defined for 115 Vac network, this test also proposes conditions for 230 Vac network. Unless otherwise specified in product standard, only 115 Vac conditions shall be satisfied.
Six levels of prospective fault current have been specified for concerned cable sizes (see Clause 7). It is generally agreed that larger sizes need not be assessed since the short-circuit phenomenon becomes dominant at low line impedances.
Unless otherwise specified in the technical/product standard sizes 002, 006 and 020 cable shall be assessed.

Luft- und Raumfahrt - Elektrische Leitungen für Luftfahrtverwendung - Teil 605: Verhalten nach Kurzschluss, feucht

Diese Norm legt ein Verfahren zur Beurteilung des Verhaltens der Isolierung einer Leitung gegenüber einem elektrischen Lichtbogen fest, der durch eine Verunreinigungsflüssigkeit erzeugt und aufrechterhalten wird.
Diese Norm ist in Verbindung mit EN 3475 100 anzuwenden.
Der Hauptzweck dieser Prüfung besteht darin,
-   auf geregelte Weise andauernde Fehlereffekte zu erzeugen, die repräsentativ sind für solche, die im Betrieb auftreten können, wenn ein typisches Leitungsbündel beschädigt und einer Verunreinigung durch eine wässrige Flüssigkeit ausgesetzt wird, so dass zwischen den Leitungen Lichtbogen entstehen;
-   zu untersuchen, ob die Isolierung zur Kriechwegbildung neigt, d. h. den Lichtbogen bis zur elektrischen Spannungsquelle auszubreiten.
Diese Prüfung, die ursprünglich für das 115-VAC-Netz festgelegt war, schlägt auch Bedingungen für das 230 VAC-Netz vor. Wenn nicht anders in der Produktnorm festgelegt, sind nur die 115-VAC-Bedinungen einzuhalten.
Sechs prospektive Fehlerstromwerte wurden für die entsprechenden Leitungsgrößen (siehe Abschnitt 7) fest¬gelegt. Es ist im Allgemeinen vereinbart, dass größere Größen nicht bewertet zu werden brauchen, da der Kurz¬schlusseffekt bei niedrigen Leitungsimpedanzen dominierend wird.
Falls in den technischen Normen/Produktnormen nicht anders festgelegt, sind Leitungen der Größen 002, 006 und 020 zu bewerten.

Série aérospatiale - Câbles électriques à usage aéronautique - Méthodes d'essais - Partie 605 : Essai de court-circuit humide

Aeronavtika - Električni kabli za uporabo v zračnih plovilih - Preskusne metode - 605. del: Mokri preskus kratkega stika

Ta evropski standard določa metodo za ocenjevanje obnašanja kabelske izolacije, ki je podvržena električnemu obloku, ki ga ustvarja in vzdržuje kontaminantna tekočina. Ta standard se mora uporabljati skupaj z EN 3475-100. Glavni namen tega testa je: - proizvajati, na nadzorovan način, nepretrgane učinke izpada delovanja, ki so reprezentativni za učinke, do katerih lahko pride med uporabo, kadar je tipičen sveženj kablov poškodovan zaradi kontaminacije z vodno tekočino, tako da pride do električnega obloka, med kabli; in – pregledati sposobnost izolacije za sledenje, za širjenje električnega obloka do električnega vira. Izvirno je definiran za omrežje 115 V izmeničnega toka, a ta preskus predlaga pogoje tudi za omrežje 230 V izmeničnega toka. Razen če je drugače opredeljeno v standardu za izdelke, morajo biti zadovoljeni le pogoji za 115 V izmeničnega toka. Za zadevne velikosti kablov je določenih šest ravni morebitnih okvarnih tokov (glej Klavzulo 7). Splošni dogovor je, da večjih velikosti ni potrebno ocenjevati, ker pojav kratkega stika postane prevladujoč pri nizkih impedancah voda. Razen če je drugače navedeno v tehničnem standardu /standardu za izdelek, je treba ocenjevati kable standardnih velikosti 002, 006 in 020.

General Information

Status
Withdrawn
Publication Date
13-Jul-2010
Withdrawal Date
09-Jan-2018
Technical Committee
Drafting Committee
Current Stage
9960 - Withdrawal effective - Withdrawal
Completion Date
10-Jan-2018

Relations

Buy Standard

Standard
EN 3475-605:2010
English language
10 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Luft- und Raumfahrt - Elektrische Leitungen für Luftfahrtverwendung - Prüfverfahren - Teil 605: Verhalten nach Kurzschluß, feuchtSérie aérospatiale - Câbles électriques à usage aéronautique - Méthodes d'essais - Partie 605 : Essai de court-circuit humideAerospace series - Cables, electrical, aircraft use - Test methods - Part 605: Wet short circuit test49.060Aerospace electric equipment and systemsICS:Ta slovenski standard je istoveten z:EN 3475-605:2010SIST EN 3475-605:2010en01-oktober-2010SIST EN 3475-605:2010SLOVENSKI
STANDARDSIST EN 3475-605:20041DGRPHãþD



SIST EN 3475-605:2010



EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 3475-605
July 2010 ICS 49.060 Supersedes EN 3475-605:2002English Version
Aerospace series - Cables, electrical, aircraft use - Test methods - Part 605: Wet short circuit test
Série aérospatiale - Câbles électriques à usage aéronautique - Méthodes d'essais - Partie 605 : Essai de court-circuit humide
Luft- und Raumfahrt - Elektrische Leitungen für Luftfahrtverwendung - Prüfverfahren - Teil 605: Verhalten nach Kurzschluß, feucht This European Standard was approved by CEN on 27 February 2010.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2010 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 3475-605:2010: ESIST EN 3475-605:2010



EN 3475-605:2010 (E) 2 Contents Page Foreword .31Scope .42Normative references .43Specimen requirements .44Preparation of specimen .55Apparatus .66Method .87Requirements .9 SIST EN 3475-605:2010



EN 3475-605:2010 (E) 3 Foreword This document (EN 3475-605:2010) has been prepared by the Aerospace and Defence Industries Association of Europe - Standardization (ASD-STAN). After enquiries and votes carried out in accordance with the rules of this Association, this Standard has received the approval of the National Associations and the Official Services of the member countries of ASD, prior to its presentation to CEN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by January 2011, and conflicting national standards shall be withdrawn at the latest by January 2011. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 3475-605:2002. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.