Animal feeding stuffs: Methods of sampling and analysis - Detection of tylosin, spiramycin and virginiamycin - Thin Layer Chromatography and bioautography

The method makes it possible to detect and identify spiramycin, tylosin and virginiamycin in animal feeding stuffs (feed raw materials of mainly plant origin and compound feeds) excluding mineral feeds and premixtures. The limit of detection is about 2 mg/kg for spiramycin, 1 mg/kg for tylosin and 1 mg/kg for virginiamycin. In some milk replacers, it can be slightly higher than 1 mg/kg for virginiamycin.
Reported limits of detection are probably little overestimated but were fully validated during the collaborative study (see Annex B). In each laboratory, each day of analysis, spiked blank samples at 1 mg/kg for spiramycin and virginiamycin and at 0,5 mg/kg for tylosin are analysed for checking lower detection limits (see 9.2 and 9.3). These lower limits of detection are achievable, but should be established with an in-house validation first.
Some other antibiotics can interfere in the detection of these 3 specific macrolide antibiotics. The known interferences are specified in Annex A of the method.
That method should be used as a qualitative screening and/or a post-screening method (after microbiological plate test, for example). The follow-up of the antibiotics presence may be done by other analytical technics (LC and/or LC-MS technics) ([4], [10]). For confirmatory purposes, LCMS is required.

Futtermittel - Probenahme- und Untersuchungsverfahren - Nachweis von Tylosin, Spiramycin und Virginiamycin - Dünnschichtchromatographie und Bioautographie

Das Verfahren ermöglicht es, Spiramycin, Tylosin und Virginiamycin in Futtermitteln (Futtermittel-Ausgangserzeugnisse hauptsächlich pflanzlichen Ursprungs und Mischfuttermittel) nachzuweisen und zu identifizieren, davon ausgeschlossen sind Mineralfuttermittel und Vormischungen. Die Nachweisgrenze (en: limit of detection, LOD) beträgt 2 mg/kg bei Spiramycin, 1 mg/kg bei Tylosin und 1 mg/kg bei Virginiamycin. In einigen Milchaustausch-Futtermitteln kann die Nachweisgrenze bei Virginiamycin leicht über 1 mg/kg liegen.
Die berichteten Nachweisgrenzen werden wahrscheinlich ein wenig überschätzt, sie wurden aber während des Ringversuchs vollständig validiert (siehe Anhang B). In jedem Laboratorium, an jedem Tag der Untersuchung werden aufgestockte Blindwertproben mit 1 mg/kg bei Spiramycin und Virginiamycin sowie mit 0,5 mg/kg bei Tylosin zur Prüfung der unteren Nachweisgrenzen (siehe 9.2 und 9.3) untersucht. Diese unteren Nachweisgrenzen sind erreichbar, sie sollten jedoch zuerst mit einer internen Validierung bestimmt werden.
Einige andere Antibiotika können den Nachweis dieser drei spezifischen Makrolid-Antibiotika stören. Die bekannten Störungen (Interferenzen) sind in Anhang A des Verfahrens angegeben.
Das Verfahren sollte als ein qualitatives Screeningverfahren und/oder Post-Screeningverfahren (beispiels-weise nach dem mikrobiologischen Plattentest) angewendet werden. Die Nachuntersuchung hinsichtlich des Vorhandenseins der Antibiotika kann durch andere Untersuchungstechniken (LC- und/oder LC MS Ver¬fahren) [4] [10] erfolgen. Für Bestätigungszwecke ist die Flüssigchromatographie mit Massenspektrometrie (en: liquid chromatography/massspectrometry, LC-MS) erforderlich.

Aliments pour animaux : Méthodes d’échantillonnage et d’analyse - Détection de tylosine, spiramycine et virginiamycine - Chromatographie sur couche mince et bioautographie

La méthode permet de détecter et d’identifier la présence de spiramycine, de tylosine et de virginiamycine dans les aliments pour animaux (matières premières destinées aux aliments pour animaux, d’origine végétale principalement, et aliments composés pour animaux), à l’exclusion des aliments minéraux et des prémélanges. La limite de détection est d’environ 2 mg/kg pour la spiramycine, 1 mg/kg pour la tylosine et 1 mg/kg pour la virginiamycine. Dans certains aliments d’allaitement, elle peut être légèrement supérieure à 1 mg/kg pour la virginiamycine.
Les limites de détection publiées sont probablement légèrement surévaluées, mais ont été entièrement validées au cours de l’étude collaborative (voir Annexe B). Dans chaque laboratoire, chaque jour d’analyse, des échantillons témoins dopés de 1 mg/kg pour la spiramycine et la virginiamycine et de 0,5 mg/kg pour la tylosine sont analysés pour vérifier les limites de détection inférieures (voir 9.2 et 9.3). Ces limites de détection inférieures peuvent être atteintes, mais il convient de les établir préalablement par une validation interne.
D’autres antibiotiques sont susceptibles d’interférer dans la détection de ces 3 antibiotiques macrolides spécifiques. Les interférences connues sont spécifiées dans l’Annexe A de la méthode.
Il convient d’utiliser la présente méthode comme une méthode de dépistage qualitatif et/ou postérieurement à une autre méthode de dépistage (après un essai sur plaque microbiologique/boites de Pétri, par exemple). Le suivi de la présence d’antibiotiques peut être assuré par d’autres techniques d’analyse (techniques SM et/ou CL-SM) ([4], [10]). La technique CL-SM est exigée à des fins de confirmation.

Krma: metode vzorčenja in analize - Določevanje tilozina, spiromicina in virginiamicina - Tenkoplastna kromatografija in bioavtografija

Metoda omogoča zaznavanje in prepoznavanje spiramicina, tilozina in virginiamicina v krmi (surovinah krme večinoma rastlinskega izvora in krmnih mešanicah), razen mineralnih krmah in premiksih. Meja zaznavanja je približno 2 mg/kg za spiramicin, 1 mg/kg za tilozin in 1 mg/kg za virginiamicin. Pri nekaterih mlečnih nadomestkih je lahko meja zaznavanja za virginiamicin rahlo višja od 1 mg/kg.
OPOMBA    Navedene meje zaznavanja so morda nekoliko precenjene, vendar so bile med medlaboratorijsko študijo v celoti potrjene (glej dodatek B). V vseh laboratorijih so vsak dan med potekom analize analizirani slepi vzorci z vrhom pri 1 mg/kg za spiramicin in virginiamicin ter 0,5 mg/kg za tilozin za namene preverjanja spodnjih meja zaznavanja (glej točki 9.2 in 9.3). Te spodnje meje zaznavanja je mogoče doseči, vendar jih je treba najprej določiti z internim preskusom.
Nekateri drugi antibiotiki lahko vplivajo na zaznavanje teh 3 specifičnih makrolidnih antibiotikov. Znani vplivi so navedeni v dodatku A metode.
Metodo je treba uporabiti kot kvalitativno presejalno metodo in/ali popresejalno metodo (po mikrobiološkem preskusu s ploščicami na primer). Poznejše spremljanje prisotnosti antibiotikov se lahko opravi z drugimi analitičnimi tehnikami (tehnika LC in/ali LC-MS) [4] [9]. Za namen potrditve se zahteva tehnika LCMS.

General Information

Status
Published
Publication Date
08-Aug-2017
Withdrawal Date
27-Feb-2018
Current Stage

Buy Standard

Standard
EN 16939:2017 - BARVE
English language
26 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Futtermittel - Probenahme- und Untersuchungsverfahren - Nachweis von Tylosin, Spiramycin und Virginiamycin - Dünnschichtchromatographie und BioautographieAliments pour animaux : Méthodes d’échantillonnage et d’analyse - Détection de tylosine, spiramycine et virginiamycine - Chromatographie sur couche mince et bioautographieAnimal feeding stuffs: Methods of sampling and analysis - Detection of tylosin, spiramycin and virginiamycin - Thin Layer Chromatography and bioautography65.120KrmilaAnimal feeding stuffsICS:Ta slovenski standard je istoveten z:EN 16939:2017SIST EN 16939:2017en,fr,de01-oktober-2017SIST EN 16939:2017SLOVENSKI
STANDARD
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 16939
August
t r s y ICS
x wä s t r English Version
Animal feeding stuffsã Methods of sampling and analysis æ Detection of tylosiná spiramycin and virginiamycin æ Thin Layer Chromatography and bioautography Aliments pour animaux ã Méthodes d 5échantillonnage et d 5analyse æ Détection de tylosineá spiramycine et virginiamycine æ Chromatographie sur couche mince et bioautographie
Futtermittel æ Probenahmeæ und Untersuchungsverfahren æ Nachweis von Tylosiná Spiramycin und Virginiamycin æ Dünnschichtchromatographie und Bioautographie This European Standard was approved by CEN on
t v April
t r s yä
egulations which stipulate the conditions for giving this European Standard the status of a national standard without any alterationä Upætoædate lists and bibliographical references concerning such national standards may be obtained on application to the CENæCENELEC Management Centre or to any CEN memberä
translation under the responsibility of a CEN member into its own language and notified to the CENæCENELEC Management Centre has the same status as the official versionsä
CEN members are the national standards bodies of Austriaá Belgiumá Bulgariaá Croatiaá Cyprusá Czech Republicá Denmarká Estoniaá Finlandá Former Yugoslav Republic of Macedoniaá Franceá Germanyá Greeceá Hungaryá Icelandá Irelandá Italyá Latviaá Lithuaniaá Luxembourgá Maltaá Netherlandsá Norwayá Polandá Portugalá Romaniaá Serbiaá Slovakiaá Sloveniaá Spainá Swedená Switzerlandá Turkey and United Kingdomä
EUROPEAN COMMITTEE FOR STANDARDIZATION COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre:
Avenue Marnix 17,
B-1000 Brussels
t r s y CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Membersä Refä Noä EN
s x { u {ã t r s y ESIST EN 16939:2017

Substances giving inhibition zones . 16 Annex B (informative)
Results of the interlaboratory study . 18 B.1 General . 18 B.2 Materials . 18 B.3 Statistics . 19 B.4 Result and interpretation . 20 Annex C (informative)
Preparation of bacterial suspensions . 24 C.1 General . 24 C.2 Classical/old fashion preparation . 24 C.2.1 Maintenance of stock culture . 24 SIST EN 16939:2017

Figure 1 — TLC plate with 2 inhibition zones 3.3 sensitivity of a method SE ability of the method to classify a positive sample as positive 3.4 specificity of a method SP ability
...

Questions, Comments and Discussion