Ambient air - Method for the determination of the concentration of nitrogen dioxide by diffusive sampling

This document specifies a method for the sampling of NO2 in ambient air using diffusive sampling followed by extraction and analysis by colorimetry or ion chromatography (IC). It can be used for the NO2 measurement in a concentration range of approximately 3 µg/m3 to 130 µg/m3 [12]. A sample is typically collected for a period of 1 to 4 weeks [14], with exposure periods depending on the design of the samplers and the concentration levels of NO2.
Several sorbents can be used for trapping NO2 in ambient air using a diffusive sampler [15]. This document specifies the application of triethanolamine as the reagent.
This document describes the application of a tube-type sampler (with either a cylindrical or a slightly conical tube), a badge-type sampler and a radial-type sampler.
The relative expanded uncertainty of NO2 measurements performed using these tube-type diffusive samplers can potentially be lower than 25 % for individual measurements. When aggregating results to form annual average values, the relative expanded uncertainty can be further reduced to levels below 15 % due to the reduction of random effects on uncertainty [9].
NOTE   NO2 passive samplers are also employed to measure NOx with the addition of an oxidant to convert ambient NO into NO2. A second NO2 sampler is also deployed without the oxidant and the concentration of NO is determined from the difference of the two samplers [16].

Außenluft - Bestimmung der Konzentration von Stickstoffdioxid mittels Passivsammler

Dieses Dokument legt ein Verfahren zur Probenahme von NO2 in Außenluft mit Passivsammlern sowie der anschließenden Extraktion und Analyse mittels Kolorimetrie oder Ionenchromatographie (IC) fest. Es kann im Konzentrationsbereich von etwa 3 µg/m3 bis 130 µg/m3 an NO2 angewendet werden [12]. Eine Probe wird üblicherweise über einen Expositionszeitraum von 1 Woche bis 4 Wochen genommen [14], wobei dieser von der Ausführung des Sammlers und dem NO2-Konzentrationsniveau abhängt.
Zur Bindung des in der Luft enthaltenen NO2 mit einem Passivsammler können verschiedene Sorptionsmittel verwendet werden [15]. In diesem Dokument ist Triethanolamin als Sorptionsmittel festgelegt.
Dieses Dokument beschreibt die Anwendung von Sammlern des Röhrchentyps (mit zylindrischem oder konischem Röhrchen), des Plakettentyps und des radialen Typs.
Die relative erweiterte Unsicherheit von mit Passivsammlern des Röhrchentyps durchgeführten NO2-Messungen kann bei Einzelmessungen unter 25 % liegen. Werden die Ergebnisse zu Jahresmittelwerten zusammengefasst, kann die relative erweiterte Unsicherheit aufgrund der Verringerung der zufälligen Einflüsse auf unter 15 % sinken [9].
ANMERKUNG   Durch Zusatz eines Oxidationsmittels (Umwandlung von NO in NO2) können NO2-Passivsammler werden auch zur Messung von NOx verwendet werden. Durch gleichzeitigen Einsatz eines zweiten NO2-Sammler ohne das Oxidationsmittel kann die NO-Konzentration anhand der Differenz der beiden Sammler ermittelt werden [16].

Air ambiant - Méthode de détermination de la concentration en dioxyde d'azote au moyen d'échantillonneurs par diffusion

Le présent document spécifie une méthode pour le prélèvement du NO2 dans l’air ambiant par échantillonnage par diffusion, suivi de l’extraction et de l’analyse par colorimétrie ou chromatographie ionique (CI). Il peut être utilisé pour le mesurage du NO2 dans une gamme de concentration allant de 3 µg/m³ à 130 µg/m3 environ [12]. Un échantillon est habituellement collecté sur une période de 1 à 4 semaines [14], les durées d’exposition dépendant de la conception des échantillonneurs et des niveaux de concentration en NO2.
Plusieurs sorbants peuvent être utilisés pour piéger le NO2 contenu dans l’air ambiant à l’aide d’un échantillonneur par diffusion [15]. Le présent document spécifie l’utilisation de triéthanolamine comme réactif.
Le présent document décrit la mise en œuvre d’un échantillonneur de type tube (intégrant un tube cylindrique ou légèrement conique), d’un échantillonneur de type badge et d’un échantillonneur à diffusion radiale.
L’incertitude élargie relative des mesurages du NO2 réalisés à l’aide de ces échantillonneurs par diffusion de type tube peut potentiellement être inférieure à 25 % pour les mesurages individuels. Lors de l’agrégation des résultats pour obtenir les valeurs moyennes annuelles, l’incertitude élargie relative peut être encore réduite à des niveaux inférieurs à 15 % en raison de la diminution des effets aléatoires sur l’incertitude [9].
NOTE   Les échantillonneurs passifs de NO2 sont également utilisés pour mesurer les NOx en ajoutant un oxydant pour convertir le NO ambiant en NO2. Un second échantillonneur de NO2 est également déployé sans l’oxydant et la concentration en NO est déterminée d’après la différence entre les deux échantillonneurs [16].

Zunanji zrak - Metoda za določevanje koncentracije dušikovega dioksida z difuzijskim vzorčenjem

General Information

Status
Not Published
Publication Date
10-Mar-2025
Current Stage
4060 - Closure of enquiry - Enquiry
Start Date
15-Feb-2024
Due Date
16-Jan-2024
Completion Date
15-Feb-2024

Relations

Buy Standard

Draft
prEN 16339:2023 - BARVE
English language
57 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
oSIST prEN 16339:2023
01-december-2023
Nadomešča:
SIST EN 16339:2013
Zunanji zrak - Metoda za določevanje koncentracije dušikovega dioksida z
difuzijskim vzorčenjem
Ambient air - Method for the determination of the concentration of nitrogen dioxide by
diffusive sampling
Außenluft - Bestimmung der Konzentration von Stickstoffdioxid mittels Passivsammler
Air ambiant - Méthode pour la détermination de la concentration du dioxyde d'azote au
moyen d'échantillonneurs par diffusion
Ta slovenski standard je istoveten z: prEN 16339
ICS:
13.040.20 Kakovost okoljskega zraka Ambient atmospheres
oSIST prEN 16339:2023 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
oSIST prEN 16339:2023

---------------------- Page: 2 ----------------------
oSIST prEN 16339:2023


DRAFT
EUROPEAN STANDARD
prEN 16339
NORME EUROPÉENNE

EUROPÄISCHE NORM

November 2023
ICS 13.040.20 Will supersede EN 16339:2013
English Version

Ambient air - Method for the determination of the
concentration of nitrogen dioxide by diffusive sampling
Air ambiant - Méthode pour la détermination de la Außenluft - Bestimmung der Konzentration von
concentration du dioxyde d'azote au moyen Stickstoffdioxid mittels Passivsammler
d'échantillonneurs par diffusion
This draft European Standard is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee
CEN/TC 264.

If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations
which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.

This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC
Management Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Türkiye and
United Kingdom.

Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are
aware and to provide supporting documentation.

Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without
notice and shall not be referred to as a European Standard.


EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2023 CEN All rights of exploitation in any form and by any means reserved Ref. No. prEN 16339:2023 E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------
oSIST prEN 16339:2023
prEN 16339:2023 (E)
Contents Page
European foreword . 4
Introduction . 5
1 Scope . 6
2 Normative references . 6
3 Terms and definitions . 6
4 Description of samplers. 8
4.1 Principle . 8
4.2 Diffusive samplers . 9
4.2.1 Description . 9
4.2.2 Preparation .
...