Respiratory protective devices - Compressed air line breathing apparatus with demand valve - Part 1: Apparatus with a full face mask - Requirements, testing, marking

This document specifies minimum requirements for compressed air line breathing apparatus with demand valve for use with a full face mask as a respiratory protective device. Escape and diving apparatus and apparatus used in abrasive blasting operations without additional protective features are not covered by this document, although certain requirements addressing the use in conjunction with escape apparatus and escape conditions are given.
Laboratory and practical performance tests are included for the assessment of conformance to the requirements.

Atemschutzgeräte - Druckluft-Schlauchgeräte mit Lungenautomat - Teil 1: Geräte mit einer Vollmaske - Anforderungen, Prüfung, Kennzeichnung

Diese Europäische Norm legt Mindestanforderungen für Druckluft-Schlauchgeräte mit Lungenautomat und einer
Vollmaske als Atemschutzgerät fest. Für Fluchtgeräte und Tauchgeräte und Geräte für Strahlarbeiten ohne
zusätzliche Schutzeinrichtungen gilt die Europäische Norm nicht, obwohl gewisse Anforderungen für den Gebrauch
in Verbindung mit Fluchtgeräten und für Fluchtbedingungen angegeben werden.
Laborprüfungen und praktische Leistungsprüfungen sind enthalten, um die Übereinstimmung mit den
Anforderungen feststellen zu können.

Appareils de protection respiratoire - Appareils de protection respiratoire isolants à adduction d'air comprimé avec soupape à la demande - Partie 1: Appareil avec masque complet - Exigences, essais, marquage

La présente Norme européenne fixe les exigences minimales des appareils de protection respiratoire isolants
à adduction d�air comprimé avec soupape à la demande avec masque complet en tant qu�appareils de
protection respiratoire. Les appareils destinés à l�évacuation, à la plongée et ceux utilisés dans les opérations
de projection d�abrasifs sans dispositifs de protection supplémentaires ne sont pas couverts par la présente
Norme européenne, bien que certaines exigences relatives à l�utilisation d�appareils destinés à l�évacuation et
aux conditions d�évacuation soient indiquées.
Il contient des essais pratiques de performance et des essais en laboratoire pour s�assurer de la conformité
avec les exigences.

Oprema za varovanje dihal - Dihalni aparat na stisnjeni zrak z ventilom – 1. del: Aparat z obrazno masko - Zahteve, preskušanje, označevanje

General Information

Status
Withdrawn
Publication Date
19-Apr-2005
Withdrawal Date
15-May-2018
Current Stage
9960 - Withdrawal effective - Withdrawal
Completion Date
16-May-2018

Relations

Buy Standard

Standard
EN 14593-1:2005
English language
35 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Respiratory protective devices - Compressed air line breathing apparatus with demand valve - Part 1: Apparatus with a full face mask - Requirements, testing, markingAppareils de protection respiratoire - Appareils de protection respiratoire isolants a adduction d'air comprimé avec soupape a la demande - Partie 1: Appareil avec masque complet - Exigences, essais, marquageAtemschutzgeräte - Druckluft-Schlauchgeräte mit Lungenautomat - Teil 1: Geräte mit einer Vollmaske - Anforderungen, Prüfung, Kennzeichnung13.340.30Varovalne dihalne napraveRespiratory protective devicesICS:SIST EN 14593-1:2005enTa slovenski standard je istoveten z:EN 14593-1:200501-julij-2005SIST EN 14593-1:2005SLOVENSKI
STANDARDSIST EN 139:1998/AC:1998SIST EN 139:1998/A1:2000SIST EN 139:19981DGRPHãþD







EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 14593-1April 2005ICS 13.340.30SEnglish versionRespiratory protective devices - Compressed air line breathingapparatus with demand valve - Part 1: Apparatus with a full facemask - Requirements, testing, markingAppareils de protection respiratoire - Appareils deprotection respiratoire isolants à adduction d'air compriméavec soupape à la demande - Partie 1: Appareil avecmasque complet - Exigences, essais, marquageAtemschutzgeräte - Druckluft-Schlauchgeräte mitLungenautomat - Teil 1: Geräte mit einer Vollmaske -Anforderungen, Prüfung, KennzeichnungThis European Standard was approved by CEN on 15 March 2005.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Central Secretariat or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia,Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2005 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 14593-1:2005: E



EN 14593-1:2005 (E) 2 Contents Page Foreword.4 Introduction.5 1 Scope.5 2 Normative references.5 3 Terms, definitions and pictograms.6 4 Description.6 5 Requirements.7 5.1 General.7 5.2 Ergonomics.7 5.3 Materials.7 5.4 Water immersion.7 5.5 Cleaning and disinfecting.7 5.6 Practical performance.8 5.7 Connections.
...