Specification for masonry units - Part 4: Autoclaved aerated concrete masonry units

This European Standard specifies the characteristics and performance requirements of autoclaved aerated concrete (AAC) masonry units for which the main intended uses are different types of load bearing and non-load bearing applications in all forms of walling including single leaf, cavity, partitions, retaining, basement and general use below ground level, including walling for fire protection, thermal insulation, sound insulation and the fabric of chimneys (excluding chimney flue units).
It defines the performance related to e.g. strength, density, dimensional accuracy etc. and provides for the evaluation of conformity of the product to this European Standard.
The marking requirement for products covered by this European Standard is included.
This European Standard does not cover the requirements for storey height panels, flue linings and masonry units with an incorporated thermal insulation material bonded to the faces of the unit susceptible to be exposed to fire. It does not specify standard sizes for autoclaved aerated concrete units nor standard work dimensions and angles of specially shaped and accessory units. It does not give permissible deviations for specially shaped and accessory units. It does not cover products intended for use as a damp proof course or the lining of a chimney.

Festlegungen für Mauersteine - Teil 4: Porenbetonsteine

Diese Europäische Norm legt die Eigenschaften und Leistungsanforderungen für dampfgehärtete Poren-beton¬steine fest, die vorwiegend in tragendem oder nichttragendem Mauerwerk in Bauwerken des Hoch- oder Tief¬baus verwendet werden und für alle Arten von Mauer¬werk einschließlich einschaligen Mauerwerks, zweischaligen Mauerwerks, Trennwänden, Stützmauern und Fundamenten sowie für die allgemeine Verwendung unter der Erdoberfläche geeignet sind, einschließlich Brand-, Wärme- und Schallschutz. Sie werden auch zur Herstellung von Schornsteinmauerwerk (ausgenommen bei der Aus¬kleidung von Rauch-abzügen) verwendet.
Sie legt die Anforderungen, z. B. an Festigkeit, Rohdichte und Maßgenauigkeit usw., und die die Konformitäts¬bewertung des von dieser Europäischen Norm erfassten Produktes fest.
Die Kennzeichnung der von dieser Europäischen Norm erfassten Produkte ist festgelegt.
Diese Europäische Norm gilt nicht für geschosshohe Tafeln, Steine für die Auskleidung von Rauchabzügen oder für Steine zur Herstellung von feuchtesperrenden Schichten. Sie gilt nicht für Steine mit einem Wärme-dämm¬stoff, der auf die Seiten des Steins, die Feuer ausgesetzt sein können, aufgebracht ist. Sie gibt weder genormte Größen für Porenbetonsteine noch Sollmaße und Winkel für Form  und Ergänzungssteine an. Sie enthält keine Grenzabmaße für Form  und Ergänzungssteine. Produkte zur Herstellung von feuchte¬sperrenden Schichten oder zur Auskleidung von Schornsteinen werden nicht behandelt.

Spécifications pour éléments de maçonnerie - Partie 4: Éléments de maçonnerie en béton cellulaire autoclavé

La présente Norme européenne spécifie les caractéristiques et les exigences de performances des éléments de maçonnerie en béton cellulaire autoclavé (BCA) dont les principales utilisations prévues sont différents types d'applications porteuses et non porteuses sous toutes les formes de murs, y compris les murs à simple ou double paroi, les cloisons, les murs de soutènement, les soubassements et les murs utilisés en sous-sol. Ils peuvent constituer une protection contre l'incendie, une isolation thermique et acoustique et un chemisage pour les conduits de fumée (excepté pour les conduits intérieurs de fumée).
Elle définit d'une part les performances relatives par exemple à la résistance, la masse volumique et les tolérances dimensionnelles et permet d'autre part d'évaluer la conformité du produit par rapport à cette Norme européenne.
Elle inclut également les exigences de marquage des produits qui y sont traités.
Cette Norme européenne ne couvre pas les exigences concernant les panneaux hauteur d'étage, les conduits intérieurs de fumée ni les éléments de maçonnerie comportant un isolant thermique rapporté sur les faces susceptibles d'être exposées au feu. Elle ne spécifie pas les formats normalisés des éléments en béton cellulaire autoclavé, les dimensions de fabrication courante, ni les caractéristiques angulaires des éléments de forme particulière et des éléments accessoires. Elle ne donne pas les tolérances dimensionnelles pour les éléments de forme particulière et les éléments accessoires. Elle ne couvre pas les produits destinés à servir d'assise anti-humidité ou de conduits intérieurs de fumée.

Specifikacija za zidake - 4. del: Zidaki iz avtoklaviranega celičnega betona

Ta evropski standard določa značilnosti in zahteve za zmogljivosti za zidake iz avtoklaviranega celičnega betona, ki so v glavnem predvideni za uporabo pri raznovrstnih nosilnih in nenosilnih aplikacijah pri vseh oblikah sten, vključno z enoslojnim zidom, votlim zidom, predelki, opornimi stenami, kletmi in splošno uporabo pod zemljo, ki vključuje stene za zaščito pred požarom, toplotno izolacijo, zvočno izolacijo in strukturo dimnikov (razen dimnih cevi). Opredeljuje zmogljivost v zvezi z npr. močjo, gostoto, dimenzijsko natančnostjo, itd. in zagotavlja oceno skladnosti proizvoda s tem evropskim standardom. Vključena je zahteva za označevanje proizvodov, ki jih zajema ta evropski standard. Ta evropski standard ne zajema zahtev za panele etažne višine, obloge dimnih cevi in zidake z vgrajenim materialom za toplotno izolacijo, vezanim na stranice zidaka, ki so lahko izpostavljene ognju. Ne določa standardnih velikosti za zidake iz avtoklaviranega celičnega betona niti ne določa standardnih delovnih dimenzij in kotov zidakov posebnih oblik in pomožnih zidakov. Ne podaja dovoljenih odstopanj za zidake posebnih oblik in pomožne zidake. Ne zajema proizvodov, ki se uporabljajo kot izolacijska zaščita pred vlago ali obloga dimnika.

General Information

Status
Withdrawn
Publication Date
03-May-2011
Withdrawal Date
18-Aug-2015
Technical Committee
Current Stage
9960 - Withdrawal effective - Withdrawal
Completion Date
19-Aug-2015

Relations

Buy Standard

Standard
EN 771-4:2011
English language
32 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-julij-2011
1DGRPHãþD
SIST EN 771-4:2004
SIST EN 771-4:2004/A1:2005
6SHFLILNDFLMD]D]LGDNHGHO=LGDNLL]DYWRNODYLUDQHJDFHOLþQHJDEHWRQD
Specification for masonry units - Part 4: Autoclaved aerated concrete masonry units
Festlegungen für Mauersteine - Teil 4: Porenbetonsteine
Spécifications pour éléments de maçonnerie - Partie 4 : Eléments de maçonnerie en
béton cellulaire autoclave
Ta slovenski standard je istoveten z: EN 771-4:2011
ICS:
91.100.30 Beton in betonski izdelki Concrete and concrete
products
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD
EN 771-4
NORME EUROPÉENNE
EUROPÄISCHE NORM
May 2011
ICS 91.100.30 Supersedes EN 771-4:2003
English Version
Specification for masonry units - Part 4: Autoclaved aerated
concrete masonry units
Spécifications pour éléments de maçonnerie - Partie 4: Festlegungen für Mauersteine - Teil 4: Porenbetonsteine
Éléments de maçonnerie en béton cellulaire autoclavé
This European Standard was approved by CEN on 17 March 2011.

CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.

This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same
status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland,
Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.

EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2011 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 771-4:2011: E
worldwide for CEN national Members.

Contents Page
Foreword .4
1 Scope .5
2 Normative references .5
3 Terms and definitions .6
4 Materials and manufacture .7
4.1 General .7
4.2 Materials of manufacture .8
5 Requirements for AAC masonry units .8
5.1 General .8
5.2 Dimensions and tolerances .8
5.2.1 Dimensions .8
5.2.2 Tolerances .9
5.3 Configuration . 10
5.4 Density . 11
5.4.1 Gross dry density . 11
5.4.2 Net dry density . 11
5.4.3 Limit deviations . 12
5.5 Compressive strength . 12
5.6 Thermal properties . 12
5.7 Durability . 12
5.8 Moisture movement . 12
5.9 Water vapour permeability . 13
5.10 Water absorption . 13
5.11 Reaction to fire . 13
5.12 Shear bond strength . 13
5.12.1 General . 13
5.12.2 Declaration based on fixed values . 13
5.12.3 Declaration based on tests . 13
5.13 Flexural bond strength . 14
6 Description, designation and classification of AAC masonry units . 14
6.1 Description and designation . 14
6.2 Classification . 14
7 Marking . 15
8 Evaluation of conformity . 15
8.1 General . 15
8.2 Initial type tests . 15
8.3 Factory production control . 16
8.3.1 General . 16
8.3.2 Testing and measuring equipment . 16
8.3.3 Production equipment . 17
8.3.4 Raw materials . 17
8.3.5 Production process . 17
8.3.6 Finished product testing . 17
8.3.7 Statistical techniques . 17
8.3.8 Marking and stock control of products . 17
8.3.9 Traceability . 17
8.3.10 Nonconforming products . 17
Annex A (normative) Sampling for initial type testing and for independent testing of
consignments . 18
A.1 General . 18
A.2 Sampling procedure for an assessment of product compliance . 18
A.2.1 General . 18
A.2.2 Random sampling . 18
A.2.3 Representative sampling . 18
A.2.4 Dividing the sample . 19
A.2.5 Number of units required for testing . 19
Annex B (normative) Cutting schemes . 20
B.1 Cutting scheme for producing cubes or prisms from AAC masonry units in order to
determine the dry density . 20
B.2 Cutting scheme for producing cubes from AAC masonry units in order to determine
compressive strength . 21
Annex C (informative) Guidance on FPC frequencies. 22
Annex ZA (informative) Clauses of this European Standard addressing the provisions of the EU
Construction Products Directive . 24
ZA.1 Scope and relevant characteristics . 24
ZA.2 Procedure(s) for attestation of conformity of autoclaved aerated concrete masonry units . 26
ZA.2.1 System(s) of attestation of conformity . 26
ZA.2.2 EC Certificate and Declaration of Conformity . 27
ZA.3 CE marking and labelling. 28
Bibliography . 32

Foreword
This document (EN 771-4:2011) has been prepared by Technical Committee CEN/TC 125 “Masonry”, the
secretariat of which is held by BSI.
This European Standard shall be given the status of a national standard, either by publication of an identical
text or by endorsement, at the latest by November 2011, and conflicting national standards shall be withdrawn
at the latest by November 2011.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights.
This document supersedes EN 771-4:2003.
This document has been prepared under a mandate given to CEN by the European Commission and the
European Free Trade Association and supports the essential requirements of the EU Construction Products
Directive (89/106/EEC).
For relationship with EU Directive(s), see informative Annex ZA, which is an integral part of this document.
This European Standard also takes into account the general rules for reinforced and unreinforced masonry in
Eurocode 6.
EN 771, Specification for masonry units consists of:
− Part 1: Clay masonry units
− Part 2: Calcium silicate masonry units
− Part 3: Aggregate concrete masonry units (Dense and light weight aggregates)
− Part 4: Autoclaved aerated concrete masonry units
− Part 5: Manufactured stone masonry units
− Part 6: Natural stone masonry units
According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following
countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus,
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.