Transportable gas cylinders - Porous masses for acetylene cylinders

This report contains information regarding high porosity masses produced after 1988 and used in the countries of the CEN members.

Premične plinske jeklenke - Porozne mase za acetilenske jeklenke

General Information

Status
Withdrawn
Publication Date
19-Mar-2002
Withdrawal Date
25-Mar-2014
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
26-Mar-2014
Completion Date
26-Mar-2014

Relations

Buy Standard

Standardization document
CR 14473:2002
English language
52 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-november-2002
3UHPLþQHSOLQVNHMHNOHQNH3RUR]QHPDVH]DDFHWLOHQVNHMHNOHQNH
Transportable gas cylinders - Porous masses for acetylene cylinders
Ta slovenski standard je istoveten z: CR 14473:2002
ICS:
23.020.30 7ODþQHSRVRGHSOLQVNH Pressure vessels, gas
MHNOHQNH cylinders
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

CEN REPORT
CR 14473
RAPPORT CEN
CEN BERICHT
March 2002
ICS
English version
Transportable gas cylinders - Porous masses for acetylene
cylinders
This CEN Report was approved by CEN on 3 November 2001. It has been drawn up by the Technical Committee CEN/TC 23.
CEN members are the national standards bodies of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece,
Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: rue de Stassart, 36  B-1050 Brussels
© 2002 CEN All rights of exploitation in any form and by any means reserved Ref. No. CR 14473:2002 E
worldwide for CEN national Members.

Contents
1 Scope .5
2 Data about high porosity masses .5
3 Country abbreviations.5
4 Data sheets for individual acetylene cylinders.5
5 Data sheets for acetylene cylinders for bundles.36
Foreword
This document (CR 14473:2002) has been prepared by Technical Committee CEN /TC 23, "Transportable gas
cylinders", the secretariat of which is held by BSI.
This report is an agreed document containing data, information and other material for high porosity masses
(monolithic) for acetylene cylinders which is nor appropriate to an EN or HD but relates to the aims and work of
CEN/TC 23.
This report has not included information and data sheets about non-monolithic porous masses.
Introduction
The information contained in this report was originally proposed as an informative annex to European Standard
EN 1801, "Transportable Gas Cylinders  Filling conditions for single acetylene cylinders" and EN 12755,
"Transportable gas cylinders  Filling conditions for acetylene bundles".
The Technical Committee CEN/TC 23 decided that due to the commercial nature of the information and the
possible difficulties in maintaining an up-to-date standard, the information should be published as a CEN report.
This report has therefore been produced for reference purposes.
1 Scope
This report contains information regarding high porosity masses (monolithic) produced after 1988 and having
received type approval from the competent authorities in the countries of the CEN members. The data is based on
information provided by manufacturers as at 2000-02-29. This list does not claim to be exhaustive
For additional entries to the lists or a change of data, an application has to be made, to the CEN/TC 23 Secretariat
with a copy of the type approval issued by the competent body.
A revision of the report in a two-year period, or after a certain number of new applications for an amendment or
change of data, is envisaged. Any decisions will be taken at a plenary meeting of CEN/TC 23.
NOTE For further information contact the relevant national representative, e.g. for Germany contact Bundesanstalt für
Materialforschung und - prüfung (BAM), D-12200 Berlin (Germany)
2 Data about high porosity masses
The filling conditions for the various high porosity masses for acetylene cylinders and acetylene bundles for the
countries in Europe which are listed below are the result of the type approval of the porous masses made by the
competent authority in the relevant country.
Basis for a new type approval by a competent authority is the European Standard EN 1800 + AC1 "Transportable
gas cylinders - Acetylene cylinders - Basic requirements and definitions".
3 Country abbreviations
Countries approving a particular mass are identified in the list as follows:
AT AUSTRIA GR GREECE
BE BELGIUM HR CROATIA
CH SWITZERLAND IE IRELAND
CZ CZECH REPUBLIC IT ITALY
DE GERMANY IS ICELAND
DK DENMARK LU LUXEMBOURG
ES SPAIN NL NETHERLANDS
FI FINLAND NO NORWAY
FR FRANCE PT PORTUGAL
GB UNITED KINGDOM SE SWEDEN
4 Data sheets for individual acetylene cylinders
Data sheets numbers 1 to 27 for individual acetylene cylinders are listed in table 1.
The countries are ranked alphabetically in accordance with country abbreviation of clause 2.
The data contained in columns 2 to 6 was the basis for the type approval of the mass.
The values for 'weight of acetylene' (kg/I) include the total amount of acetylene, including saturation gas.
The weight of solvent in column 2 is specified weight of solvent (kg/I) of water capacity of the cylinder shell as given
in the approval.
Column 3 lists the maximum weight of acetylene in (kg/I) of water capacity of the cylinder shell when the cylinder is
'empty'.
Data with question mark could not be clarified during the preparation of the technical report and is uncertain data.
Table 1 — Summary of data sheets for individual acetylene cylinders
Identification Manufacturer Solvent ) Number of
data sheet
(name)
of porous mass
AGA 1 AGA AB acetone 1
AGA 2 AGA Cryo GmbH acetone 2
AGA 2 AGA Cryo GmbH DMF 3
AGA 4 AGA Cryo GmbH acetone 4
AL 4 L'Air Liquide SA acetone /DMF 5
JH-Coyne Josef Heiser acetone 6
Heiser-Eco Josef Heiser acetone 7
Heiser-Eco Josef Heiser DMF 8
Linde M 1 Linde AG acetone 9
Linde M 1 Linde AG without solvent 10
Linde M 1 A Linde AG acetone 11
Linde M 1 D Linde AG DMF 12
MAXI POR Compagnia Navarro SA acetone/DMF 13
NA Compagnia Navarro SA acetone/DMF 14
NLH Technoplyn n.p. acetone 15
NORAL L'Air Liquide SA acetone 16
POR 92 Technogas-Kraljevo acetone 17
SIAD 2 SIAD S.p.A. acetone 18
SIAD 2 SIAD S.p.A. DMF 19
SIAD 3 SIAD S.p.A. DMF 20
SIAD AF SIAD S.p.A. acetone 21
T 200 Technogas-Inos acetone 22
T 200 A Technogas-Inos acetone 23
UL 1 Linde Technoplyn acetone 24
UL 1 Linde Technoplyn without solvent 25
BOC-COYNE BOC LTD acetone 26
BOC 1 BOC LTD Acetone 27
) DMF . Dimethylformamid
Data sheet No. 1
Individual acetylene cylinders
Identification (name) Type of mass: monolithic
of porous mass:          AGA 1 Solvent: acetone
Manufacturer:
AGA AB Density (kg/l): 0,300 - 0,330
S – 181 81 LIDINGO
SWEDEN Porosity (%): 78 - 80
Country Weight of Weight of Max. settled Additional Year of approval/
solvent acetylene pressure comments identification
number
(kg/l) (kg/l) (bar) 15 °C
12 3 4 5 6
AT
BE
CH 0,288 0,159
DE
DK
ES
IE
FR
GB
GR
IT
IS
LU
NO
NL 0,2825 0,1625
PT
SE 0,290 0,155 50 l
0,320 0,170 40 l
FI 0,2630 0,1575
Data sheet No. 2
Individual acetylene cylinders
Identification (name Type of mass: monolithic
of porous mass: )          AGA 2 Solvent: acetone
Manufacturer:
AGA Cryo GmbH Density (kg/l): 0,225 - 0,255
Industriestrasse 114
D-21107 Hamburg Porosity (%): 90 - 93
Country Weight of Weight of Max. settled Additional Year of approval/
solvent acetylene pressure comments identification
number
(kg/l) (kg/l) (bar) 15 °C
12 3 4 5 6
AT 0,310 0,180 18 max. 10 l 1988
0,200 19 40 - 54 1978
BE 0,335 0,168 15 1983
CH 0,320 0,140 – 0,190*) 19 den. 0,240
por. 91 %
DE 0,310 0,1800,200 18 < 5 l> 5 l 1970/05DM2
19 + 1971
DK 0,310 0,200 18 1980
ES 0,318 0,18 18 1988
IE
FR 0,374 0,162 15 por. max. 1983
92 %
GB 0,310 0,200 18 por. max. 1977
92 %
GR
IT
IS 0,320 0,200 18 1980
LU
NO 0,310 0,185 19 1971
NL 0,320 0,180 19 10,20 l 1966
0,320 0,185 40,59 l
0,326 0,194 50 l
PT
SE 0,310 0,180 19 1 – 5 l 1980
0,200 10 – 50 l
FI 0,310 0,180 18 1 – 5 l 1980
0,200 18 10 – 50 l
*) 0,140 kg/l < 3 l
0,160 kg/l  3 - < 10 lt
0,170 kg/l  10 - < 20 lt
0,190 kg/l  20 -  60 lt
Data sheet No. 3
Individual acetylene cylinders
Identification (name) Type of mass: monolithic
of porous mass:          AGA 2 Solvent: DMF
Manufacturer:
AGA Cryo GmbH Density (kg/l): 0,225 – 0,255
Industriestrasse 114
D – 21107 Hamburg Porosity (%): 90 - 93
Country Weight of Weight of Max. settled Additional Year of approval/
solvent acetylene pressure comments identification
number
(kg/l) (kg/l) (bar) 15 °C
12 3 4 5 6
AT
BE
CH 0,412 0,180 ?
DE
DK
ES
IE
FR
GB
GR
IT
IS
LU
NO
NL 0,400 0,195 18 1994
PT
SE
FI
Data sheet No. 4
Individual acetylene cylinders
Identification (name) Type of mass: monolithic
asbestos free
of porous mass:          AGA 4
Solvent: acetone
Manufacturer:
AGA Cryo GmbH Density (kg/l): 0,265 - 0,295
Industriestrasse 114
D – 21107 Hamburg Porosity (%): 89 - 92
Country Weight of Weight of Max. settled Additional Year of approval/
solvent acetylene pressure comments identification
number
(kg/l) (kg/l) (bar) 15 °C
12 3 4 5 6
AT 0,310 0,180 18 < 20 l 1995/A-AGA 4
0,200 19 20 – 54 l
BE
CH
DE 0,310 0,180 18 < 20 l 1993/05 DM 4
0,200 19
 20 l
DK 0,310 0,180 18 < 20 l 1994
0,200
 20 l
ES 0,310 0,200 18 1995
IE
FR 0,310 0,200 18 1997
GB 0,180 18 < 20 l 1993
0,200
 20 l
GR
IT
IS
LU
NO 0,310 0,180 19 < 20 l 1994
0,200
 20 l
NL 0,326 0,180 18 < 20 l 1993
0,194 20 – 54 l
PT
SE 0,310 0,180 19 < 20 l 1994
0,200
 20 l
FI 0,310 0,180 19 < 20 l 1993
0,200
 20 l
Data sheet No. 5
Individual acetylene cylinders
Identification (name) Type of mass: monolithic
of porous mass:          AL 4 Solvent: acetone/DMF
Manufacturer:
L'Air Liquide SA Density (kg/l): 0,238 – 0,262
75 Quai d'Orsay
F – 75321 Paris Cedex 07 Porosity (%): 90 - 92
Country Weight of Weight of Max. settled Additional comments Year of approval/
solvent acetylene pressure identification
number
(kg/l) (kg/l) (bar) 15 °C
12 3 4 5 6
AT
BE 0,348 0,174 acetone 1963
0,335 0,169 acetone
0,386 0,176 DMF
CH
DE 0,310 0,200
DK 0,325 0,194 20 l cap. 1977
por. 90 – 92 %
ES 0,328 0,167 acetone por. 91 %
IE
FR 0,354 0,181 Acetone 1983/1996
0,327 0,181 acetone 1996
0,407 0,192 DMF por. 91 % 1984/1998
GB 0,308 0,176 acetone 1969
por. 91 %
GR
IT
IS
LU
NO 0,320 0,185 acetone 1971/1973
por. 90 – 92 % ?
NL 0,326 0,180 Acetone 1982
0,400 0,194 DMF 1972
por. 91 %
50 l cap.
PT 0,354 0,181 acetone 1963
0,327 0,181 acetone 1983
0,407 0,192 DMF por. 91 %
SE 0,338 ? 0,178 acetone 1968
0,357 0,183 por. 90 – 92 %
den. 0,25
FI
Data sheet No. 6
Individual acetylene cylinders
Identification (name) Type of mass: monolithic
of porous mass:     JH-COYNE Solvent: acetone
Manufacturer:
Josef Heiser Density (kg/l): 0,260 – 0,280
Postfach 1
A – 3291 Kienberg/Gaming Porosity (%): 89 - 91
Country Weight of Weight of Max. settled Additional comments Year of
solvent acetylene pressure approval/
identification
number
(kg/l) (kg/l) (bar) 15 °C
12 3 4 5 6
AT 0,320 0,175 15 for all sizes 1969
0,305 0,1665 18 1981
 10 l
0,305 0,185 18 1981
20 – 50 l
0,320 0,185 18 1981
60 l welded only
BE 0,320 0,175 18 1969
CH 0,335 0,175 18 Re-qualified 1972
0,184 18
DE 0,305 0,1665 18  10 l 1978/02 A M5
0,1575 18
20 – 50 l
DK 0,320 0,175 18
ES 0,330 0,187 18
IE 0,330 0,184 18
FR
GB 0,330 0,184 18 1977
GR 0,320 0,175 18
IT 0,320 0,175 18
IS 0,320 0,175 18
LU
NO 0,320 0,185 18 5, 10, 20, (27) l 1977
40 – 50 l 1975
NL 0,330 0,185 18 20 – 50 l 1974
0,320 0,180 5 – 10 l 1985
PT 0,330 0,187 18
SE 0,300 0,184 18 1978
 10 l
FI 0,320 0,175 18  10 l 1976/77/80
0,330 0,185
20 – 50 l
Data sheet No. 7
Individual acetylene cylinders
Identification (name) Type of mass: monolithic
asbestos free
of porous mass: )     Heiser-Eco
Solvent: acetone
Manufacturer:
Josef Heiser Density (kg/l): 0,23 – 0,26
Postfach 1
A – 3291 Kienberg/Gaming Porosity (%): 89,0 – 92,0
Country Weight of Weight of Max. settled Additional comments Year of
solvent acetylene pressure approval/
identification
(kg/l) (kg/l) (bar) 15 °C
number
12 3 4 5 6
AT 0,310 0,180 18 < 10 l 1993
0,310 0,190 19 10 - < 20 l 1993
0,310 0,200 19 20 – 50 l 1993
BE 0,326 0,170 15 5 – 50 l 1993
CH 0,310 0,160 ? 15 3 - < 10 l 1992/92310-11
0,310 0,170 ? 18 10 - < 20 l 1993
0,310 0,190 ? 19 20 – 50 l 1993
DE 0,310 0,200 19 20 – 50 l 1993
0,190 19 20 l 02 AM 100
0,310 0,190 20
DK 0,310 0,200 19
0,190
ES 0,310 0,180 18 3 – 10 l 1993
0,310 0,190 19 10 – 20 l 1993
0,310 0,200 19 20 – 50 l 1993
IE
FR 0,310 0,180 19 5 – 10 l 1997
0,310 0,190 19 10 – 20 l 1997
0,310 0,200 19 20 – 50 l 1997
GB 0,310 0,180 18 < 10 l 1993
0,310 0,190 19 10 – < 20 l 1993
0,310 0,200 19 20 – 50 l 1993
GR
IT
IS
LU
NO
NL 0,326 0,194 18 5 – 50 l 1993
PT 0,310 0,180 < 10 l
SE 0,310 0,180 3 - < 10 l 1993
0,310 0,190 10 - < 20 l
0,310 0,200 20 – 54 l
FI 0,310 0,180 < 10 l 1993
0,310 0,190 10 - < 20 l
0,310 0,200 > 20 l
Data sheet No. 8
Individual acetylene cylinders
Identification (name) Type of mass: monolithic
asbestos free
of porous mass: )     Heiser-Eco
Solvent: DMF
Manufacturer:
Josef Heiser Density (kg/l): 0,23 – 0,26 kg/l
Postfach 1
A – 3291 Kienberg/Gaming Porosity (%): 89,0 – 92,0
Country Weight of Weight of Max. settled Additional comments Year of
solvent acetylene pressure approval/
identification
number
(kg/l) (kg/l) (bar) 15
...

Questions, Comments and Discussion