EN 13200-4:2006
(Main)Spectator facilities - Part 4: Seats - Product characteristics
Spectator facilities - Part 4: Seats - Product characteristics
This European Standard specifies the mechanical, physical and chemical product characteristics of fixed seating used in sports venues (indoor and outdoor) in the spectator viewing area (S.V.A.). It also specifies the criteria for fixing the seating to the structure.
These characteristics and criteria are determined in order to assure an adequate resistance to static and dynamic stresses and to atmospheric agents. This European Standard specifies comfort, functionality and safety requirements to prevent serious injury through normal functional use, as well as misuse that might reasonably be excepted to occur. This European Standard does not include any fire behaviour or resistance requirements.
Zuschaueranlagen - Teil 4: Sitze - Produktmerkmale
Dieser europäische Norm-Entwurf legt die mechanischen, physikalischen und chemischen Produktmerkmale
von ortsfest montierten Sitzen im Zuschauerbereich von Sport- und Mehrzweckanlagen (in Innenräumen und
im Freien) fest. Außerdem werden die Kriterien für die Befestigung des Gestühls am Baukörper festgelegt.
Diese Merkmale und Kriterien werden bestimmt, um eine angemessene Beständigkeit gegenüber statischer
und dynamischer Belastung sowie gegenüber witterungsbedingter und luftchemischer Beanspruchung
sicherzustellen. Die Norm legt die Anforderungen an Komfort, Funktionalität und Sicherheit fest, um
ernsthaften Verletzungen sowohl bei üblichen Gebrauch als auch bei Missbrauch vorzubeugen und letzteren
weitestgehend auszuschließen. In dieser Norm sind keine Anforderungen in Bezug auf Brandverhalten und
Beständigkeit enthalten.
Installations pour spectateurs - Partie 4: Sièges - Caractéristiques des produits
Norme Européenne spécifie les caractéristiques mécaniques, physiques et chimiques des sièges fixes utilisés
lors de manifestations sportives (à l’intérieur et à l’extérieur), dans l’espace d’observation des spectateurs.
Elle spécifie également les critères de fixation des sièges à la structure.
Ces caractéristiques et critères sont déterminés dans le but d’assurer une résistance adéquate aux
contraintes statiques et dynamiques ainsi qu’aux agents atmosphériques. La présente Norme Européenne
spécifie des exigences concernant le confort, la fonctionnalité et la sécurité pour prévenir toute blessure grave
pouvant résulter d’une utilisation fonctionnelle normale ainsi que d’un mauvais usage raisonnablement
prévisible. La présente Norme Européenne ne comprend aucune exigence relative au comportement au feu
des sièges.
Prostori za gledalce – 4. del: Lastnosti sedežev
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Spectator facilities - Part 4: Seats - Product characteristicsProstori za gledalce – 4. del: Lastnosti sedeževInstallations pour spectateurs - Partie 4: Sieges - Caractéristiques des produitsZuschaueranlagen - Teil 4: Sitze - ProduktmerkmaleTa slovenski standard je istoveten z:EN 13200-4:2006SIST EN 13200-4:2007en97.220.10Športni objektiSports facilities97.200.10Gledališka, odrska in studijska oprema ter delovne postajeTheatre, stage and studio equipment91.040.10Javne stavbePublic buildingsICS:SLOVENSKI
STANDARDSIST EN 13200-4:200701-marec-2007EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 13200-4October 2006ICS 91.040.10; 97.200.10; 97.220.10 English VersionSpectator facilities - Part 4: Seats - Product characteristicsInstallations pour spectateurs - Partie 4: Sièges -Caractéristiques des produitsZuschaueranlagen - Teil 4: Sitze - ProduktmerkmaleThis European Standard was approved by CEN on 28 August 2006.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Central Secretariat or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania,Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2006 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 13200-4:2006: E
EN 13200-4:2006 (E) 2 Contents Page Foreword..............................................................................................................................................................3 1 Scope......................................................................................................................................................4 2 Normative references............................................................................................................................4 3 Terms and definitions...........................................................................................................................4 4 Abbreviations.........................................................................................................................................5 5 General requirements of construction................................................................................................5 5.1 Seats.......................................................................................................................................................5 5.2 General requirements for fixing elements and fixing methods........................................................6 5.2.1 General....................................................................................................................................................6 5.2.2 Criteria for presentation of designs.....................................................................................................7 5.2.3 Acceptance testing................................................................................................................................7 6 Sampling and conditioning...................................................................................................................7 6.1 Sampling.................................................................................................................................................7 6.2 Conditioning...........................................................................................................................................7 7 Characteristics of materials..................................................................................................................7 7.1 General....................................................................................................................................................7 7.2 Corrosion resistance.............................................................................................................................7 7.3 Resistance to weathering agents/stability to light.............................................................................8 7.4 Temperature resistance........................................................................................................................8 8 Strength and durability requirements..................................................................................................8 9 Test report............................................................................................................................................10 10 Seating numbers..................................................................................................................................11 11 Instruction for use...............................................................................................................................11 12 Marking.................................................................................................................................................11 Annex A (informative)
Temperature resistance.............................................................................................12 A.1 Temperature resistance......................................................................................................................12 A.1.1 General..................................................................................................................................................12 A.1.2 Low temperature test..........................................................................................................................12 A.1.3 High temperature test..........................................................................................................................12 Annex B (informative)
Examples of seats.......................................................................................................13 Annex C (informative)
Ergonomy....................................................................................................................15 C.1 Ergonomy.............................................................................................................................................15 C.1.1 Anthropometric aspects and data......................................................................................................15 C.1.2 Design requirements...........................................................................................................................15 Bibliography......................................................................................................................................................24
EN 13200-4:2006 (E) 3 Foreword This document (EN 13200-4:2006) has been prepared by Technical Committee CEN/TC 315 “Spectators facilities”, the secretariat of which is held by UNI. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by April 2007, and conflicting national standards shall be withdrawn at the latest by April 2007. EN 13200 Spectator facilities consists of the following parts: Part 1: Layout criteria for spectator viewing area — Specification Part 3: Separating elements — Requirements Part 4: Seats-product characteristics Part 5: Telescopic stands Part 6: Demountable (temporary) stands According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EN 13200-4:2006 (E) 4 1 Scope This European Standard specifies the mechanical, physical and chemical product characteristics of fixed seating used in sports venues (indoor and outdoor) in the spectator viewing area (S.V.A.). It also specifies the criteria for fixing the seating to the structure. These characteristics and criteria are determined in order to assure an adequate resistance to static and dynamic stresses and to atmospheric agents. This European Standard specifies comfort, functionality and safety requirements to prevent serious injury through normal functional use, as well as misuse that might reasonably be excepted to occur. This European Standard does not include any fire behaviour or resistance requirements. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 12727, Furniture — Ranked seating — Test methods and requirements for strength and durability EN 13200-1, Spectator facilities — Part 1: Layout criteria for spectator viewing area — Specification ENV 581-2:2000, Outdoor furniture — Seating and tables for camping, domestic and contract use — Part 2: Mechanical safety requirements and test methods for sampling EN ISO 527-2, Plastics — Determination of tensile properties — Part 2: Test conditions for moulding and extrusion plastics (ISO 527-2:1993 including Corr. 1:1994) EN ISO 4892-2, Plastics — Methods of exposure to laboratory light sources — Part 2: Xenon-arc lamps (ISO 4892-2:2006) ISO 105-A02, Textiles — Tests for colour fastness — Part A02: Grey scale for assessing change in colour ISO 179-1:2000, Plastics — Determination of Charpy impact properties — Part 1: Non-instrumented impact test (ISO 179-1:2000) ISO 554, Standard atmospheres for conditioning and/or testing — Specifications 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 seating place space intended for a single spectator in a sitting position (see figures in Annex B) 3.2 seats
bench, a continuous element, forming a raised seat level with respect to the footway (Figure B.1); low back seat, a shaped element or an assembly fixed to the step or on to a support. It has a backrest with a maximum height of 15 cm above the seat level and may be fitted with armrests (Figure B.2);
EN 13200-4:2006 (E) 5 high back seat, a shaped element or an assembly fixed to the step or on to a support. It has a backrest with a minimum height of 15 cm above the seat level and may be fitted with armrests (Figure B.3); tip-up seat, a seating place where in the seat elements automatically returns to the upright position on the departure of the occupant (Figure B.4) 3.3 fixing elements elements for attaching the seat to the fixed support 3.4 fixing method assembly of elements for attaching the support or the seats to a stand 3.5 seat numbering means of identifying seat position NOTE 1 The different types of seating places which are shown in the figures are only examples. NOTE 2 For general terms relating to the structures of spectator facilities, see EN 13200-1. 4 Abbreviations For the purposes of this document, the abbreviations in EN 13200-1 and the following apply. Bse: dimension of the tread where seating places are (seating row depth); F: depth of seats including the thickens of the back; I: width of seats (minimum dimension for lateral boundaries of a single seating place); E: distance between the foremost projection of one seat and the back of the seat in front of it (clearway); S: height of seat back, including the thickness of the seat. 5 General requirements of construction 5.1 Seats The seats shall comply with the following general requirements. a) it shall be so designed to not cause injury to the user. All parts of the seating place with which the user comes into contact, during the intended use, shall be so designed that physical injury and damage to spectator property are avoided. The following consideration are necessary: the safety distance of accessible movable parts is addressed to EN 294 in any position during movement; all accessible parts are without sharp edges/corners; the edges of the seat, backrest and armrests which are in contact with the user when sitting, are rounded with recommended minimum 3 mm radius; the ends of hollow components are closed or capped.
EN 13200-4:2006 (E) 6 b) all parts which are lubricated to assist sliding (greasing, lubricating etc.) shall be designed to protect users from lubricant stains when in normal use; c) seats shall be securely fixed to the steps or to the supports; d) the shape of the seats shall be such as to allow rain and water to drain and shall allow easy cleaning of it and of the underlying steps; e) if the components are made of different materials, they shall be compatible with each other; f) the seating place shall comply the minimum dimensions given in EN 13200-1; g) the recommended values are given in Table 1.
Table 1 — Recommended dimensional criteria for seats Row depth (Bse) (mm) Seat type
F (mm)I (mm)
S (mm)min rec
Bench
300
700
800
Seat with low back
400
500
< 150
700
800
Seat with high back
400
500
> 150
700
800
5.2 General requirements for fixing elements and fixing methods 5.2.1 General The fixing of the seats shall comply with the following requirements: a) the fixing elements of the seats shall withstand the forces generated during the tests described in
EN 12727; b) it shall not be possible to remove the seats without the use of a special tool; c) the fixing methods shall be compatible with the supporting structure; d) the metal eleme
...