EN 61169-39:2011
(Main)Radio-frequency connectors - Part 39: Sectional specification for CQM series quick lock RF connectors
Radio-frequency connectors - Part 39: Sectional specification for CQM series quick lock RF connectors
IEC 61169-39:2009(E) is a sectional specification. It provides information and rules for the preparation of detail specifications for CQM series quick lock RF connectors together with the pro forma blank detail specification (DS). It also prescribes mating interface dimensions for general purpose connectors, dimensional details of standard test connectors grade 0, gauging information and tests selected from IEC 61169-1, applicable to all detail specifications relating to CQM series connectors.
Hochfrequenz-Steckverbinder - Teil 39: Rahmenspezifikation für HF-Steckverbinder der CQM-Serie mit Schnellverriegelung
Connecteurs pour fréquences radioélectriques – Partie 39: Spécification intermédiaire pour les connecteurs RF à verrouillage rapide de la série CQM
La CEI 61169-39:2009 est une spécification intermédiaire. Elle fournit des informations et des règles en vue de l'établissement de spécifications particulières de connecteurs RF à verrouillage rapide de la série CQM, ainsi que de la spécification particulière cadre pro forma. Elle prescrit également les dimensions de l'interface d'accouplement pour des connecteurs d'usage général, les détails dimensionnels des connecteurs d'essai normalisés de classe 0, des informations de calibrage et des essais choisis dans la CEI 61169-1, applicables à toutes les spécifications particulières ayant trait aux connecteurs de la série CQM. La présente spécification indique les caractéristiques de performance recommandées à prendre en compte pour la rédaction d'une spécification particulière, et elle couvre les programmes d'essais et les exigences de contrôle pour les niveaux d'assurance qualité M et H. La présente version bilingue, publiée en 2011-04, correspond à la version anglaise. La version française de cette norme n'a pas été soumise au vote.
Radiofrekvenčni konektorji - 39. del: Področna specifikacija za radiofrekvenčne (RF) zaklepne konektorje serije CQM (IEC 61169-39:2009)
Zaklepni konektorji serije CQM z značilno impedanco 50 O se uporabljajo za mikrovalovne naprave visoke moči, povezane z radiofrekvenčnimi (RF) kabli ali mikrotrakovi. Meja delovne frekvence je vsaj 4 GHz. Ta področna specifikacija zagotavlja podatke in pravila za pripravo podrobnih specifikacij za radiofrekvenčne zaklepne konektorje serije CQM, skupaj s formalno okvirno podrobno specifikacijo. Prav tako predpisuje dimenzije vtičnega vmesnika za konektorje za splošno uporabo, podrobnosti za dimenzije standardnih preskusnih konektorjev razreda 0, podatke o preskušanju in preskusih, izbrane iz IEC 61169-1, ki veljajo za vse podrobne specifikacije, ki se nanašajo na konektorje serije CQM. Ta specifikacija navaja priporočene lastnosti delovanja, ki jih je treba upoštevati pri pisanju podrobne specifikacije in zajema programe preskušanja in zahteve glede pregleda za ravni ocen M in H.
General Information
Standards Content (Sample)
SLOVENSKI STANDARD
01-julij-2011
5DGLRIUHNYHQþQLNRQHNWRUMLGHO3RGURþQDVSHFLILNDFLMD]DUDGLRIUHNYHQþQH
5)]DNOHSQHNRQHNWRUMHVHULMH&40,(&
Radio-frequency connectors - Part 39: Sectional specification for CQM series quick lock
RF connectors (IEC 61169-39:2009)
Hochfrequenz-Steckverbinder - Teil 39: Rahmenspezifikation für HF-Steckverbinder der
CQM-Serie mit Schnellverriegelung (IEC 61169-39:2009)
Connecteurs pour fréquences radioélectriques - Partie 39: Spécification intermédiaire
pour les connecteurs RF à verrouillage rapide de la série CQM (CEI 61169-39:2009)
Ta slovenski standard je istoveten z: EN 61169-39:2011
ICS:
33.120.30 5DGLRIUHNYHQþQLNRQHNWRUML R.F. connectors
5)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD
EN 61169-39
NORME EUROPÉENNE
May 2011
EUROPÄISCHE NORM
ICS 33.120.30
English version
Radio-frequency connectors -
Part 39: Sectional specification for CQM series quick lock RF connectors
(IEC 61169-39:2009)
Connecteurs pour fréquences Hochfrequenz-Steckverbinder -
radioélectriques – Partie 39: Spécification Teil 39: Rahmenspezifikation für HF-
intermédiaire pour les connecteurs RF à Steckverbinder der CQM-Serie mit
verrouillage rapide de la série CQM Schnellverriegelung
(CEI 61169-39:2009) (IEC 61169-39:2009)
This European Standard was approved by CENELEC on 2011-01-02. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,
Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia,
Spain, Sweden, Switzerland and the United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Management Centre: Avenue Marnix 17, B - 1000 Brussels
© 2011 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 61169-39:2011 E
Foreword
The text of document 46F/107/CDV, future edition 1 of IEC 61169-39, prepared by SC 46F, R.F. and
microwave passive components, of IEC TC 46, Cables, wires, waveguides, R.F. connectors, R.F. and
microwave passive components and accessories, was submitted to the IEC-CENELEC parallel vote and
was approved by CENELEC as EN 61169-39 on 2011-01-02.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent
rights.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2011-10-02
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2014-01-02
Annex ZA has been added by CENELEC.
__________
Endorsement notice
The text of the International Standard IEC 61169-39:2009 was approved by CENELEC as a European
Standard without any modification.
In the official version, for Bibliography, the following note has to be added for the standard indicated:
IEC 62037 NOTE Harmonized as EN 62037.
__________
- 3 - EN 61169-39:2011
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.
Publication Year Title EN/HD Year
IEC 61169-1 1992 Radio-frequency connectors – EN 61169-1 1994
Part 1: Generic specification - General
requirements and measuring methods
IEC 61169-39 ®
Edition 1.0 2009-06
INTERNATIONAL
STANDARD
Radio-frequency connectors –
Part 39: Sectional specification for CQM series quick lock RF connectors
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
PRICE CODE
U
ICS 33.120.30 ISBN 978-2-88910-431-4
– 2 – 61169-39 © IEC:2009(E)
CONTENTS
FOREWORD.0H4
1 Scope.1H6
2 Normative references .2H6
3 Mating interface and gauge information .3H6
3.1 Dimensions-General connectors – Grade 2 .4H7
3.1.1 Connector with pin-centre contact.5H7
3.1.2 Connectors with socket-centre contact .6H8
3.2 Gauges .7H9
3.2.1 Connectors with socket-centre contact .8H9
3.3 Dimensions – standard test connectors – Grade 0.9H11
3.3.1 Connector with pin-centre contact.10H11
3.3.2 Connector with socket-centre contact .11H13
4 Quality assessment procedure.12H14
4.1 General .13H14
4.2 Rating and characteristics (see Clause 6 of IEC 61169-1) .14H14
4.3 Test schedule and inspection requirements .15H17
4.3.1 Acceptance tests .16H17
4.3.2 Periodic tests .17H18
4.4 Procedures.18H19
4.4.1 Quality conformance inspection .19H19
4.4.2 Qualification approval and its maintenance.20H19
5 Instructions for preparation of detail specifications .21H19
5.1 General .22H19
5.2 Identification of the detail specification .23H20
5.3 Identification of the component.24H20
5.4 Performance.25H20
5.5 Marking, ordering information and related matters .26H20
5.6 Selection of tests, test conditions and severities.27H20
5.7 Blank detail specification pro-forma for type CQM connector .28H21
Bibliography.29H26
Figure 1 – Connector with pin-centre contact (for dimensions, see Table 1).30H7
Figure 2 – Connector with socket-centre contact (for dimensions, see Table 2) .31H8
Figure 3 – Gauge for outer contact of socket connector (for dimensions, see Table 3) .32H9
Figure 4 – Gauge pin for socket contact (for dimensions, see Table 4) .33H9
Figure 5 – Connector of pin-centre contact (for dimensions, see Table 5).34H11
Figure 6 – Standard test connector with socket-centre contact (for dimensions, see
Table 6) .35H13
Table 1 – Dimensions of connector with pin-centre contact .36H7
Table 2 – Dimensions of connector with socket-centre contact.37H8
Table 3 – Dimensions of gauge for outer contact of socket connector .38H9
Table 4 – Dimensions of gauge pin for socket contact.39H10
Table 5 – Dimensions of connector with pin-centre contact .40H12
61169-39 © IEC:2009(E) – 3 –
Table 6 – Dimensions of standard test connector with socket-centre contact .41H14
Table 7 – Ratings and characteristics .42H15
Table 8 – Acceptance tests.43H17
Table 9 – Periodic tests .44H18
– 4 – 61169-39 © IEC:2009(E)
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
RADIO-FREQUENCY CONNECTORS –
Part 39: Sectional specification for CQM
series quick lock RF connectors
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with an IEC Publication.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61169-39 has been prepared by subcommittee 46F: RF and
microwave passive components, of IEC technical committee 46: Cables, wires, waveguides,
R.F. connectors, R.F. and microwave p
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.