Measurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Part 1: Devices used next to the ear (Frequency range of 300 MHz to 6 GHz)

IEC 62209-1:2016 specifies protocols and test procedures for measurement of the peak spatial-average SAR induced inside a simplified model of the head with defined reproducibility. It applies to certain electromagnetic field (EMF) transmitting devices that are positioned next to the ear, where the radiating structures of the device are in close proximity to the human head, such as mobile phones, cordless phones, certain headsets, etc. These protocols and test procedures provide a conservative estimate with limited uncertainty for the peak-spatial SAR that would occur in the head for a significant majority of people during normal use of these devices. The applicable frequency range is from 300 MHz to 6 GHz. This second edition cancels and replaces the first edition published in 2005. This edition constitutes a technical revision.

Messverfahren für die Beurteilung der spezifischen Absorptionsrate bei der Exposition von Personen gegenüber hochfrequenten Feldern von handgehaltenen und am Körper getragenen schnurlosen Kommunikationsgeräten – Teil 1: Geräte, die in enger Nachbarschaft zum Ohr benutzt werden (Frequenzbereich von 300 MHz bis 6 GHz)

Procédure de mesure pour l'évaluation du débit d'absorption spécifique de l'exposition humaine aux champs radiofréquences produits par les dispositifs de communications sans fil tenus à la main ou portés près du corps - Partie 1: Dispositifs utilisés à proximité de l’oreille (Plage de fréquences de 300 MHz à 6 GHz)

L'IEC 62209-1:2016 spécifie les protocoles et les procédures d'essai pour le mesurage du DAS maximal moyenné induit à l'intérieur d'un modèle simplifié de la tête avec une reproductibilité définie. Elle s'applique à certains dispositifs de communication tels que les téléphones mobiles, les téléphones sans fil, les casques, etc., émettant des champs électromagnétiques (EMF) et qui sont utilisés tenus contre l'oreille, les structures rayonnantes étant proches de la tête. Ces protocoles et procédures d'essai fournissent une estimation prudente avec une incertitude limitée pour le DAS maximal qui se produirait dans la tête pour une grande majorité de personnes lors de l'utilisation normale de ces dispositifs. La plage de fréquences applicable s'étend de 300 MHz à 6 GHz. Cette deuxième édition annule et remplace la première édition parue en 2005. Cette édition constitue une révision technique.

Izpostavljenost ljudi elektromagnetnemu sevanju brezžičnih komunikacijskih naprav, ki se držijo v roki ali pritrdijo na telo, modeli človeka, instrumenti in postopki - 1. del: Postopki za ugotavljanje stopnje specifične absorpcije (SAR) za naprave, ki se uporabljajo v bližini ušesa (frekvenčno območje od 300 MHz do 6 GHz)

Ta del standarda IEC 62209 določa protokole in preskusne postopke za merjenje najvišje prostorsko-povprečne stopnje specifične absorpcije znotraj poenostavljenega modela glave z določeno ponovljivostjo. Uporablja se za nekatere prenosne naprave z elektromagnetnim poljem (EMF), ki so nameščene ob ušesu, pri čemer so sevajoči deli naprave v neposredni bližini uporabnikove glave, kot so mobilni telefoni, brezžični telefoni, nekateri tipi slušalk, itd. Ti protokoli in preskusni postopki zagotavljajo previdno oceno z omejeno negotovostjo glede najvišje prostorske stopnje specifične absorpcije, do katere bi prišlo v glavi za veliko večino uporabnikov naprave med običajno uporabo te naprave. Uporablja se frekvenčni razpon od 300 MHz do 6 GHz.

General Information

Status
Published
Publication Date
03-Nov-2016
Withdrawal Date
09-Aug-2019
Current Stage
6060 - Document made available - Publishing
Start Date
04-Nov-2016
Completion Date
04-Nov-2016

Relations

Buy Standard

Standard
EN 62209-1:2017 - BARVE
English language
228 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-april-2017
1DGRPHãþD
SIST EN 62209-1:2006
,]SRVWDYOMHQRVWOMXGLHOHNWURPDJQHWQHPXVHYDQMXEUH]åLþQLKNRPXQLNDFLMVNLK
QDSUDYNLVHGUåLMRYURNLDOLSULWUGLMRQDWHORPRGHOLþORYHNDLQVWUXPHQWLLQ
SRVWRSNLGHO3RVWRSNL]DXJRWDYOMDQMHVWRSQMHVSHFLILþQHDEVRUSFLMH 6$5 ]D
QDSUDYHNLVHXSRUDEOMDMRYEOLåLQLXãHVD IUHNYHQþQRREPRþMHRG0+]GR
*+]
Human exposure to radio frequency fields from hand-held and body-mounted wireless
communication devices human models, instrumentation, and procedures - Part 1:
Procedure to determine the specific absorption rate (sar) for devices used next to the ear
(frequency range of 300 mhz to 6 ghz)
/
Exposition humaine aux champs radiofréquence produits par les dispositifs de
communications sans fils tenus à la main ou portés près du corps modèles de corps
humain, instrumentation et procédures - Partie 1: Détermination du débit d’absorption
spécifique (das) pour les dispositifs utilisés à proximité de l’oreille (gamme de fréquences
de 300 mhz à 6 ghz)
Ta slovenski standard je istoveten z: EN 62209-1:2016
ICS:
13.280 Varstvo pred sevanjem Radiation protection
33.050.10 Telefonska oprema Telephone equipment
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD EN 62209-1
NORME EUROPÉENNE
EUROPÄISCHE NORM
November 2016
ICS 33.060.20 Supersedes EN 62209-1:2006
English Version
Measurement procedure for the assessment of specific
absorption rate of human exposure to radio frequency fields from
hand-held and body-mounted wireless communication devices -
Part 1: Devices used next to the ear (Frequency range of 300
MHz to 6 GHz)
(IEC 62209-1:2016)
Procédure de mesure pour l'évaluation du débit Sicherheit von Personen in hochfrequenten Feldern von
d'absorption spécifique de l'exposition humaine aux champs handgehaltenen und am Körper getragenen schnurlosen
radiofréquences produits par les dispositifs de Kommunikationsgeräten - Körpermodelle, Messgeräte und -
communications sans fil tenus à la main ou portés près du verfahren - Teil 1: Verfahren zur Bestimmung der
corps - Partie 1: Dispositifs utilisés à proximité de l'oreille spezifischen Absorptionsrate (SAR) von Geräten, die in
(Plage de fréquences de 300 MHz à 6 GHz) enger Nachbarschaft zum Ohr benutzt werden
(IEC 62209-1:2016) (Frequenzbereich von 300 MHz bis 6 GHz)
(IEC 62209-1:2016)
This European Standard was approved by CENELEC on 2016-08-10. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.

European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2016 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN 62209-1:2016 E
European foreword
The text of document 106/361/FDIS, future edition 2 of IEC 62209-1 prepared by IEC/TC 106X
"Methods for the assessment of electric, magnetic and electromagnetic fields associated with human
exposure" was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as
The following dates are fixed:
• latest date by which the document has to be (dop) 2017-05-10
implemented at national level by
publication of an identical national
standard or by endorsement
(dow) 2019-08-10
• latest date by which the national
standards conflicting with the
document have to be withdrawn
This document supersedes EN 62209-1:2006.

Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such
patent rights.
Endorsement notice
The text of the International Standard IEC 62209-1:2016 was approved by CENELEC as a European
Standard without any modification.
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications

The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.

NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod), the relevant
EN/HD applies.
NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available here:
www.cenelec.eu
Publication Year Title EN/HD Year

ISO/IEC 17025 2005 General requirements for the competence EN ISO/IEC 17025 2005
of testing and calibration laboratories
ISO/IEC 17043 2010 Conformity assessment - General EN ISO/IEC 17043 2010
requirements for proficiency testing

IEC 62209-1 ®
Edition 2.0 2016-07
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
colour
inside
Measurement procedure for the assessment of specific absorption rate of

human exposure to radio frequency fields from hand-held and body-mounted

wireless communication devices –

Part 1: Devices used next to the ear (Frequency range of 300 MHz to 6 GHz)

Procédure de mesure pour l'évaluation du débit d'absorption spécifique de

l'exposition humaine aux champs radiofréquences produits par les dispositifs

de communications sans fil tenus à la main ou portés près du corps –

Partie 1: Dispositifs utilisés à proximité de l’oreille (Plage de fréquences de

300 MHz à 6 GHz)
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
INTERNATIONALE
ICS 33.060.20 ISBN 978-2-8322-3500-3

– 2 – IEC 62209-1:2016 © IEC 2016
CONTENTS
FOREWORD. 11
INTRODUCTION . 13
1 Scope . 14
2 Normative references . 14
3 Terms and definitions . 14
4 Symbols and abbreviations . 19
4.1 Physical quantities . 19
4.2 Constants . 20
4.3 Abbreviations . 20
5 Measurement system specifications . 20
5.1 General requirements . 20
5.2 Phantom specifications (shell and liquid) . 22
5.3 Hand and device holder considerations . 23
5.4 Scanning system requirements . 23
5.5 Device holder specifications . 23
5.6 Characteristics of the readout electronics . 24
6 Protocol for SAR assessment . 24
6.1 General . 24
6.2 Measurement preparation . 24
6.2.1 Preparation of tissue-equivalent liquid and system check . 24
6.2.2 Preparation of the wireless device under test (DUT) . 25
6.2.3 Operating modes . 26
6.2.4 Positioning of the DUT in relation to the phantom . 27
6.2.5 Test frequencies for DUT . 34
6.3 Tests to be performed . 34
6.4 Measurement procedure . 36
6.4.1 General . 36
6.4.2 General procedure . 37
6.4.3 SAR measurements of handsets with multiple antennas or multiple
transmitters . 39
6.5 Post-processing of SAR measurement data . 45
6.5.1 Interpolation . 45
6.5.2 Extrapolation . 46
6.5.3 Definition of the averaging volume . 46
6.5.4 Searching for the maxima . 46
6.6 Fast SAR testing . 46
6.6.1 General . 46
6.6.2 Fast SAR measurement procedure A . 47
6.6.3 Fast SAR testing of required frequency bands . 49
6.6.4 Fast SAR measurement procedure B . 50
6.7 SAR test reduction . 52
6.7.1 General requirements . 52
6.7.2 Test reduction for different operating modes in the same frequency
band using the same wireless technology . 53
6.7.3 Test reduction based on characteristics of DUT design . 54
6.7.4 Test reduction based on SAR level analysis . 55

IEC 62209-1:2016 © IEC 2016 – 3 –
6.7.5 Test reduction based on simultaneous multi-band transmission
considerations . 57
7 Uncertainty estimation . 58
7.1 General considerations. 58
7.1.1 Concept of uncertainty estimation . 58
7.1.2 Type A and Type B evaluation . 59
7.1.3 Degrees of freedom and coverage factor . 59
7.2 Components contributing to uncertainty . 60
7.2.1 General . 60
7.2.2 Calibration of the SAR probes . 60
7.2.3 Contribution of mechanical constraints . 65
7.2.4 Phantom shell . 66
7.2.5 Device positioning and holder uncertainties . 67
7.2.6 Tissue-equivalent liquid parameter uncertainty . 69
7.2.7 Uncertainty in SAR correction for deviations in permittivity and
conductivity .
...