prEN IEC 62053-22:2026 is a CLC draft standard in the IEC 62053 series for electricity metering equipment. It specifies particular requirements and type tests for static meters for AC active energy in accuracy classes 0,1S, 0,2S and 0,5S, mainly for manufacturers, test laboratories, certification bodies and buyers who need to check meter design and performance.
What does prEN IEC 62053-22:2026 specify?
prEN IEC 62053-22:2026 applies to transformer-operated and transducer-operated static watt-hour meters for measuring alternating-current active energy in 50 Hz or 60 Hz networks. It is written for type testing, so it is the document used to assess meter design rather than routine field operation.
The standard covers meters for networks up to 1 000 V AC, with all functional elements enclosed in one meter case except the display. It allows integrated or detached displays, or no display, and it also covers meters installed in a specified matching socket or rack.
The document also allows extra functions on the meter, but those extra functions are outside its own requirements. It excludes portable meters, meters for rolling stock, vehicles, ships and airplanes, laboratory and test equipment, reference standard meters, and multi-device systems where devices are physically remote from each other.
| Annex | What it covers |
|---|---|
| Annex A | Informative comparison of relative error limits at reference conditions for classes 0,1S, 0,2S and 0,5S |
What are the key requirements of prEN IEC 62053-22:2026?
prEN IEC 62053-22:2026 builds on IEC 62052-11 for general meter requirements, then adds class-specific limits and tests for the higher-accuracy AC active energy meters in this part. In practice, the standard tells you how to rate the meter, how to test it, and what accuracy shifts are acceptable under normal conditions and under disturbances.
Electrical values and operating ranges
Clause 4 sets the standard electrical values, including voltages, currents, frequencies and power consumption. For current, the document uses the concepts of starting, minimum, transitional and maximum current signals, and it gives different relationships for transformer-operated and transducer-operated meters.
For a reader, this matters because the meter design and the test set-up must match the declared current range. If the meter is intended for a transducer interface, the developer must check that the chosen transducer and meter combination supports the expected operating range.
Construction, marking and documentation
Clauses 5 and 6 require the meter construction, marking and documentation rules of IEC 62052-11 to apply. That means the physical build, identification and user documentation are treated as part of the meter’s compliance picture, not as optional extras.
In practice, this is what allows a purchaser or test lab to verify that the meter can be installed and identified correctly and that its declared ratings match its actual configuration.
Accuracy at reference conditions
Clause 7.9 sets the accuracy limits at reference conditions. The meter’s relative error must stay within the limits for its accuracy class, and the limits depend on current signal and phase angle.
For meters that measure energy in both directions, the limits apply in each direction. For meters rated for multiple connection modes, the tested connection mode is the one that supports the accuracy claim, so the test plan must match the intended wiring arrangement.
Influence quantities and disturbance tests
Clause 7.10 limits the error shift caused by influence quantities such as electromagnetic fields, fast transients, harmonics, voltage variation, temperature variation, phase reversal, auxiliary supply variation and short-time overcurrents. The tests are performed one influence at a time while the meter otherwise remains at reference conditions.
This section matters because it shows how stable the meter must remain when real-world disturbances appear on the installation. For buyers and laboratories, it defines which disturbance tests matter and how to judge the metrological shift caused by each one.
Climatic requirements and type testing
Clauses 8, 9 and 10 cover climatic requirements, external influences and type test requirements. The document also points back to IEC 62052-11 for the detailed test conditions and acceptance criteria, and it states that Table 6 of this document is used for acceptance criteria A.
In practice, this means the meter is not only checked for accuracy at nominal conditions, but also for performance under temperature, humidity and other environmental stresses that can appear in service.
What terms does prEN IEC 62053-22:2026 define?
The terms and definitions come from IEC 62052-11, but the following terms are central to understanding this part:
- AC - alternating current, the supply type used by the meters covered by this part.
- AC active energy - the active energy measured in AC networks for billing or energy accounting.
- Transformer-operated meter - a meter intended to work with current transformers or voltage transformers in the measurement chain.
- Transducer-operated meter - a meter intended to work with external transducers, and the standard also allows testing such meters without the transducers.
- Starting current signal - the low current level used to check whether the meter begins to register energy correctly.
- Minimum current signal - the lower operating current level used for accuracy checks near the bottom of the measuring range.
- Transitional current signal - the current point used in this part to separate parts of the accuracy range and to express other current signal levels.
- Type test - the test programme used to verify a meter design before production or approval.
Who uses prEN IEC 62053-22:2026?
prEN IEC 62053-22:2026 is used by meter manufacturers, test laboratories, utilities, metrology authorities and procurement teams. Manufacturers use it to design and declare meters for classes 0,1S, 0,2S and 0,5S.
Test laboratories and certification bodies use it to run type tests, check accuracy and confirm performance under influence quantities. Buyers, quality managers and utility engineers use it to compare meter offerings, write procurement specifications and verify that a meter suits a billing or submetering application.
What changed in prEN IEC 62053-22:2026 from the previous edition?
This third edition cancels and replaces the second edition published in 2020, and it is described as a technical revision. The significant technical changes stated in the document are:
- Normative references were updated.
- Transducer-operated meters were included in the scope, with testing without transducers.
- The transitional current was introduced.
- Starting current, minimum current and maximum current are now expressed as fractions of the transitional current.
- A test for ripple on DC supply voltage was introduced.
- The figures in Annex A were revised.
Which standards are used with prEN IEC 62053-22:2026?
IEC 62052-11 edition 2 CDV:2026 is the normative reference for this part. It supplies the general meter requirements, test conditions, methods and acceptance criteria that prEN IEC 62053-22:2026 builds on.
The introduction also names related parts that are used together with this standard:
| Standard | Contribution |
|---|---|
| IEC 62052-31:2024 | Product safety requirements and tests |
| IEC 62052-41:2022 | Energy registration methods and requirements for multi-energy and multi-rate meters |
| IEC 62053-21 edition 3 CDV:2026 | Static meters for AC active energy, classes 0,5, 1 and 2 |
| IEC 62053-23 edition 3 CDV:2026 | Static meters for reactive energy |
| IEC 62053-24 edition 3 CDV:2026 | Static meters for fundamental component reactive energy |
| IEC 62053-41:2021 | Static meters for DC energy |
| IEC 62055-31:2022 | Static payment meters for active energy |
| IEC 62057-1:2023 | Stationary meter test units |
| IEC 62057-3:2024 | Automatic meter testing system |
| IEC 62058-11:2008 | General acceptance inspection methods |
| IEC 62058-31:2008 | Acceptance inspection for static meters for active energy |
| IEC TR 62059-11:2002 | General dependability concepts |
| IEC TR 62059-21:2002 | Collection of meter dependability data from the field |
| IEC 62059-32-1:2011 | Stability testing by elevated temperature |
What does the prEN IEC 62053-22:2026 document contain?
The document is organized into clauses on scope, normative references, terms and definitions, standard electrical values, construction, marking, accuracy requirements, climatic requirements, external influences and type tests. The accuracy chapter is the core of the document, because it combines reference-condition verification with disturbance and environmental testing.
It includes Tables 1 to 6 for current signals and error limits, and Annex A with two figures that compare relative error limits for the three accuracy classes at reference conditions. For a lab or certification team, these tables and figures are the practical tools used to set up tests, judge pass or fail, and compare class performance.
Relations
- Effective Date
- 08-Apr-2025
- Effective Date
- 08-Apr-2025
Get Certified
Connect with accredited certification bodies for this standard
BSMI (Bureau of Standards, Metrology and Inspection)
Taiwan's standards and inspection authority.
Sponsored listings
Frequently Asked Questions
prEN IEC 62053-22:2026 is a draft published by CLC. Its full title is "Electricity metering equipment - Particular requirements - Part 22: Static meters for AC active energy (classes 0,1S, 0,2S and 0,5S)". This standard covers: Electricity metering equipment - Particular requirements - Part 22: Static meters for AC active energy (classes 0,1S, 0,2S and 0,5S)
Electricity metering equipment - Particular requirements - Part 22: Static meters for AC active energy (classes 0,1S, 0,2S and 0,5S)
prEN IEC 62053-22:2026 is classified under the following ICS (International Classification for Standards) categories: 17.220.20 - Measurement of electrical and magnetic quantities. The ICS classification helps identify the subject area and facilitates finding related standards.
prEN IEC 62053-22:2026 has the following relationships with other standards: It is inter standard links to EN IEC 62053-22:2021, EN IEC 62053-22:2021/A11:2021. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
prEN IEC 62053-22:2026 is associated with the following European legislation: EU Directives/Regulations: 2014/30/EU; Standardization Mandates: M/441, M/552. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
prEN IEC 62053-22:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Standard electrical values
- 4.1 Voltages
- 4.2 Currents
- 4.3 Frequencies
- 4.4 Power consumption
- 5 Construction requirements
- 6 Meter marking and documentation
- 7 Accuracy requirements
- 7.1 General test conditions
- 7.2 Methods of accuracy verification
- 7.3 Measurement uncertainty
- 7.4 Meter constant
- 7.5 Initial start-up of the meter
- 7.6 Test of no-load condition
- 7.7 Starting current test
- 7.8 Repeatability test
- 7.9 Limits of error due to variation of the current signal
- 7.10 Limits of error shift due to influence quantities
- 2 I ≤ I ≤ I
- 7.11 Time-keeping accuracy
- 8 Climatic requirements
- 9 The effects of external influences
- 10 Type test
- Annex A
- Bibliography
INTRODUCTION This part of IEC 62053 is to be used with relevant parts of the IEC 62052, IEC 62058 and IEC 62059 series, Electricity metering equipment, with the IEC 62055 series, Electricity metering – Payment systems and with the IEC 62057 series, Electrical energy meters:
IEC 62052-11 edition 2 CDV:2026 , Electricity metering equipment – General requirements, tests and test conditions – Part 11: Metering equipment IEC 62052-31:2024, Electricity metering equipment – General requirements, tests and test conditions – Part 31: Product safety requirements and tests IEC 62052-41:2022, Electricity metering equipment – General requirements, tests and test conditions – Part 41: Energy registration methods and requirements for multi-energy and multirate meters IEC 62053-21 edition 3 CDV :2026, Electricity metering equipment – Particular requirements – Part 21: Static meters for AC active energy (classes 0,5, 1 and 2) IEC 62053-23 edition 3 CDV :2026, Electricity metering equipment – Particular requirements – Part 23: Static meters for reactive energy (classes 2 and 3) IEC 62053-24 edition 3 CDV :2026, Electricity metering equipment – Particular requirements – Part 24: Static meters for fundamental component reactive energy (classes 0,5 S, 1 S, 1, 2 and 3) IEC 62053-41:2021, Electricity metering equipment – Particular requirements – Part 41: Static meters for DC energy (classes 0,5 and 1) IEC 62055-31:2022, Electricity metering – Payment systems – Part 31: Particular requirements - Static payment meters for active energy (classes 1 and 2) IEC 62057-1:2023, Electrical energy meters – Test equipment, techniques and procedures – Part 1: Stationary meter test units (MTUs) IEC 62057-3:2024, Electrical energy meters – Test equipment, techniques and procedures – Part 3: Automatic meter testing system (AMTS) IEC 62058-11:2008, Electricity metering equipment (AC) – Acceptance inspection – Part 11:
General acceptance inspection methods IEC 62058-31:2008, Electricity metering equipment (AC) – Acceptance inspection – Part 31:
Particular requirements for static meters for active energy (classes 0,2 S, 0,5 S, 1 and 2) IEC TR 62059-11:2002, Electricity metering equipment – Dependability – Part 11: General concepts IEC TR 62059-21:2002, Electricity metering equipment – Dependability – Part 21: Collection of meter dependability data from the field IEC 62059-32-1:2011, Electricity metering equipment – Dependability – Part 32-1: Durability – Testing of the stability of metrological characteristics by applying elevated temperature This part is a standard for type testing electricity meters. It covers the particular requirements for meters, being used indoors and outdoors in large quantities worldwide. It does not deal with special implementations (such as metering-part and/or displays in separate housings).
oSIST prEN IEC 62053-22:2026
This document is intended to be used in conjunction with IEC 62052-11 edition 2 CDV:2026 and with IEC 62052-31:2024. When any requirement in this document concerns an item already covered in IEC 62052-11 edition 2 CDV:2026 or in IEC 62052-31:2024, the requirements of this document take precedence over the requirements of IEC 62052-11 edition 2 CDV:2026 or of IEC 62052-31:2024.
The specifications and test levels in this document are regarded as minimum values for the proper functioning of electricity measurement and load control equipment under normal working conditions. For special applications, additional or extended specificat ions or test levels might be necessary and are permitted but are neither identified nor prescribed in this document.
oSIST prEN IEC 62053-22:2026
1 Scope
This part of IEC 62053 applies only to transformer-operated or transducer-operated static watthour meters of accuracy classes 0,1 S, 0,2 S and 0,5 S for the measurement of alternating current electrical active energy in 50 Hz or 60 Hz networks and it applies to their type tests only.
NOTE 1 For other general requirements, such as safety, dependability, etc., see the relevant standards in the IEC 62052 or IEC 62059 series.
This document applies to electricity metering equipment designed to:
- measure and control electrical energy on electrical networks (mains) with voltage up to 1 000 V AC; NOTE 2 For AC electricity meters, the voltage mentioned above is the line-to-neutral voltage derived from nominal voltages. See IEC 62052-31:2024, Table 7.
- have all functional elements, including add-on modules, enclosed in, or forming a single meter case with exception of indicating displays;
- operate with integrated or detached indicating displays, or without an indicating display;
- be installed in a specified matching socket or rack;
- optionally, provide additional functions other than those for measurement of electrical energy.
Meters designed for operation with external transducers may be tested for compliance with this document:
- as directly connected meters, when such meters and their transducers are tested together; - as transducer-operated meters when such meters are tested without transducers. NOTE 3 When transducer-operated meters are tested without transducers, the reference measurements may be performed at the input terminals of the meter. This may require, for example, a traceable reference standard meter (standard, French: étalon) with inputs compatible with mV or mA level transducer output signals. Another practical way to test transducer-operated meters is to perform the reference measurement at the input terminals of calibrated reference transducers. This way, the reference standard meters, and test current sources may be the same as those used for testing of transformer-operated meters. The transformation ratio, metrological characteristics and uncertainty of the reference transducers are known and their influence can be removed by post -processing the test data. The determination of the appropriate test methodology is left to the expertise of the testing laboratory. NOTE 4 Modern electricity meters typically contain additional functions such as measurement of voltage magnitude, current magnitude, power, frequency, power factor, etc.; measurement of power quality parameters; load control functions; delivery, time, test, accounting, recording functions; data communication interfaces and associated data security functions. The relevant standards for these functions may apply in addition to the requirements of this document. However, the requirements for such functions are outside the scope of this document. NOTE 5 Product requirements for power metering and monitoring devices (PMDs) and measurement functions such as voltage magnitude, current magnitude, power, frequency, etc., are covered in IEC 61557-12. However, devices compliant with IEC 61557-12 are not intended to be used as billing meters unless they are also compliant with IEC 62052-11 edition 2 CDV:2026 and one or more relevant IEC 62053-xx accuracy class standards. NOTE 6 Product requirements for power quality instruments (PQIs) are covered in IEC 62586-1. Requirements for power quality measurement techniques (functions) are covered in IEC 61000-4-30. Requirements for testing of the power quality measurement functions are covered in IEC 62586-2. This document does not apply to:
- meters for which the voltage line-to-neutral derived from nominal voltages exceeds 1 000 V AC; - metering systems comprising multiple devices (except transducers) physically remote from one another; - portable meters; NOTE 7 Portable meters are meters that are not permanently connected. - meters used in rolling stock, vehicles, ships and airplanes;
oSIST prEN IEC 62053-22:2026
...