Nuclear power plants - Instrumentation and control important to safety - Electrical equipment condition monitoring methods - Part 6: Insulation resistance

This part of IEC/IEEE 62582 contains methods for condition monitoring of organic and polymeric materials in instrumentation and control cables using insulation resistance measurements in the detail necessary to produce accurate and reproducible results during simulated accident conditions. It includes the requirements for the measurement system and measurement procedure, and the reporting of the measurement results. NOTE Measurement of insulation resistance during simulated accident conditions with the aim of determining the lowest value during the accident in order to assess cable performance involves special requirements given in this document. Methods for measurement under stable (non-accident) conditions are available in other international standards, e.g. IEC 62631-3-3. The different parts of the IEC/IEEE 62582 series are measurement standards, primarily for use in the management of ageing in initial qualification and after installation. IEC/IEEE 62582- 1 includes requirements for the application of the other parts of the IEC/IEEE 62582 series and some elements which are common to all methods. Information on the role of condition monitoring in qualification of equipment important to safety is found in IEC/IEEE 60780-323.

Kernkraftwerke - Leittechnik mit sicherheitstechnischer Bedeutung - Zustandsüberwachung elektrischer Geräte - Teil 6: Isolationswiderstand

Centrales nucléaires de puissance – Instrumentation et contrôle-commande importants pour la sûreté – Méthodes de surveillance de l'état des matériels électriques – Partie 6: Résistance d'isolement

Jedrske elektrarne - Merilna in nadzorna oprema za zagotavljanje varnosti - Metode za spremljanje stanja električne opreme - 6. del: Izolacijska upornost (IEC/IEEE 62582-6:2019)

General Information

Status
Published
Publication Date
15-Jul-2021
Current Stage
6060 - Document made available - Publishing
Start Date
16-Jul-2021
Completion Date
16-Jul-2021

Buy Standard

Standard
EN IEC/IEEE 62582-6:2021 - BARVE
English language
27 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN IEC/IEEE 62582-6:2021
01-september-2021
Jedrske elektrarne - Merilna in nadzorna oprema za zagotavljanje varnosti -
Metode za spremljanje stanja električne opreme - 6. del: Izolacijska upornost
(IEC/IEEE 62582-6:2019)
Nuclear power plants - Instrumentation and control important to safety - Electrical
equipment condition monitoring methods - Part 6: Insulation resistance (IEC/IEEE 62582
-6:2019)
Kernkraftwerke - Leittechnik mit sicherheitstechnischer Bedeutung -
Zustandsüberwachung elektrischer Geräte - Teil 6: Isolationswiderstand (IEC/IEEE
62582-6:2019)
Centrales nucléaires de puissance - Instrumentation et contrôle-commande importants
pour la sûreté – Méthodes de surveillance de l'état des matériels électriques - Partie 6:
Résistance d'isolement (IEC/IEEE 62582-6:2019)
Ta slovenski standard je istoveten z: EN IEC/IEEE 62582-6:2021
ICS:
27.120.20 Jedrske elektrarne. Varnost Nuclear power plants. Safety
SIST EN IEC/IEEE 62582-6:2021 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
SIST EN IEC/IEEE 62582-6:2021

---------------------- Page: 2 ----------------------
SIST EN IEC/IEEE 62582-6:2021


EUROPEAN STANDARD EN IEC/IEEE 62582-6

NORME EUROPÉENNE

EUROPÄISCHE NORM
July 2021
ICS 27.120.20

English Version
Nuclear power plants - Instrumentation and control important to
safety - Electrical equipment condition monitoring methods - Part
6: Insulation resistance
(IEC/IEEE 62582-6:2019)
Centrales nucléaires de puissance - Instrumentation et Kernkraftwerke - Leittechnik mit sicherheitstechnischer
contrôle-commande importants pour la sûreté - Méthodes Bedeutung - Zustandsüberwachung elektrischer Geräte -
de surveillance de l'état des matériels électriques - Partie 6: Teil 6: Isolationswiderstand
Résistance d'isolement (IEC/IEEE 62582-6:2019)
(IEC/IEEE 62582-6:2019)
This European Standard was approved by CENELEC on 2021-07-05. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the
Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.


European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2021 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
 Ref. No. EN IEC/IEEE 62582-6:2021 E

---------------------- Page: 3 ----------------------
SIST EN IEC/IEEE 62582-6:2021
EN IEC/IEEE 62582-6:2021 (E)
European foreword
This document (EN IEC/IEEE 62582-6:2021) consists of the text of IEC/IEEE 62582-6:2019 prepared
by IEC/TC 45 "Nuclear instrumentation".
The following dates are fixed:
• latest date by which the document has to be implemented at national (dop) 2022-07-05
level by publication of an identical national standard or by endorsement
• latest date by which the national standards conflicting with the (dow) 2024-07-05
document have to be withdrawn

Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC shall not be held responsible for identifying any or all such patent rights.
As stated in the nuclear safety directive 2009/71/EURATOM, Chapter 1, Article 2, item 2, Member
States are not prevented from taking more stringent safety measures in the subject-matter covered by
the Directive, in compliance with Community law.
In a similar manner, this European standard does not prevent Member States from taking more
stringent nuclear safety and/or security measures in the subject-matter covered by this standard.
Any feedback and questions on this document should be directed to the users’ national standards
body/national committee. A complete listing of these bodies can be found on the CEN and CENELEC
websites.
Endorsement notice
The
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.