Electrical relays - Tests and measurements - Part 9: Climatic tests

Elektrische Relais – Mess- und Prüfverfahren – Teil 9: Klimatische Prüfungen

Relais électriques - Essais et mesurages - Partie 9: Essais climatiques

Električni releji - Preskusi in meritve - 7-9. del: Klimatski preskusi

General Information

Status
Not Published
Publication Date
22-Dec-2024
Current Stage
5060 - Voting results sent to TC, SR - Formal Approval
Start Date
20-Sep-2024
Completion Date
20-Sep-2024

Buy Standard

Draft
prEN IEC 61810-7-9:2023
English language
11 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
oSIST prEN IEC 61810-7-9:2023
01-december-2023
Električni releji - Preskusi in meritve - 7-9. del: Klimatski preskusi
Electrical relays - Tests and Measurements - Part 7-9: Climatic tests
Ta slovenski standard je istoveten z: prEN IEC 61810-7-9:2023
ICS:
29.120.70 Releji Relays
oSIST prEN IEC 61810-7-9:2023 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

oSIST prEN IEC 61810-7-9:2023
oSIST prEN IEC 61810-7-9:2023
94/953/CDV
COMMITTEE DRAFT FOR VOTE (CDV)
PROJECT NUMBER:
IEC 61810-7-9 ED1
DATE OF CIRCULATION: CLOSING DATE FOR VOTING:
2023-10-13 2024-01-05
SUPERSEDES DOCUMENTS:
94/799/CD, 94/949/CC
IEC TC 94 : ELECTRICAL RELAYS
SECRETARIAT: SECRETARY:
Austria Mr Bernhard Spalt
OF INTEREST TO THE FOLLOWING COMMITTEES: PROPOSED HORIZONTAL STANDARD:

Other TC/SCs are requested to indicate their interest, if any, in
this CDV to the secretary.
FUNCTIONS CONCERNED:
EMC ENVIRONMENT QUALITY ASSURANCE SAFETY
SUBMITTED FOR CENELEC PARALLEL VOTING NOT SUBMITTED FOR CENELEC PARALLEL VOTING
Attention IEC-CENELEC parallel voting
The attention of IEC National Committees, members of CENELEC,
is drawn to the fact that this Committee Draft for Vote (CDV) is
submitted for parallel voting.
The CENELEC members are invited to vote through the CENELEC
online voting system.
This document is still under study and subject to change. It should not be used for reference purposes.
Recipients of this document are invited to submit, with their comments, notification of any relevant patent rights of which they are
aware and to provide supporting documentation.
Recipients of this document are invited to submit, with their comments, notification of any relevant “In Some Countries” clau ses to be
included should this proposal proceed. Recipients are reminded that the CDV stage is the final stage for submitting ISC c lauses.
(SEE AC/22/2007 OR NEW GUIDANCE DOC).

TITLE:
Electrical relays - Tests and Measurements - Part 7-9: Climatic tests

PROPOSED STABILITY DATE: 2025
NOTE FROM TC/SC OFFICERS:
electronic file, to make a copy and to print out the content for the sole purpose of preparing National Committee positions.
You may not copy or "mirror" the file or printed version of the document, or any part of it, for any other purpose without
permission in writing from IEC.

oSIST prEN IEC 61810-7-9:2023
94/953/CDV – 2 – IEC CDV 61810-7-9 © IEC 2023
1 CONTENTS
3 FOREWORD . 3
4 1 Scope . 5
5 2 Normative references . 5
6 3 Terms and definitions . 5
7 4 Test procedure . 6
8 4.1 Purpose . 6
9 4.2 Procedure . 6
10 General . 6
11 Dry heat . 6
12 Damp heat, cyclic, first cycle . Error! Bookmark not defined.
13 Cold . 7
14 Low air pressure . 7
15 Damp heat, cyclic, all or remaining cycles . 7
16 Damp heat steady state . 7
17 4.3 Conditions . 8
18 5 Evaluation: . 8
19 5.1 General . 8
20 5.2 Final measurements. 9
21 For all tests . 9
22 For the test of 4.2.7 . 9
23 5.3 Final judgement . 9
24 Annex T (normative) Test report . 10
25 Bibliography . 11
27 Table 1 – Summary of tests . 6
oSIST prEN IEC 61810-7-9:2023
IEC CDV 61810-7-9 © IEC 2023 – 3 – 94/953/CDV
30 INTERNATIONAL ELECTROTECHNICAL COMMISSION
31 ____________
33 ELECTROMECHANICAL ELEMENTARY RELAYS –
35 Part 7-9: Climatic Tests
37 FOREWORD
38 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
39 all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international
40 co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and
41 in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports,
42 Publicly Available Specifications (PAS) and Guides (hereafter referred to as "IEC Publication(s)"). Their
43 preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with
44 may participate in this preparatory work. International, governmental and non-governmental organizations liaising
45 with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for
46 Standardization (ISO) in accordance with conditions determined by agreement between the two or ganizations.
47 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
48 consensus of opinion on the relevant subjects since each technical committee has representation from all
49 interested IEC National Committees.
50 3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
51 Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
52 Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
53 misinterpretation by any end user.
54 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
55 transparently to the maximum extent possible in their national and regional publications. Any divergence between
56 any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter.
57 5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
58 assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
59 services carried out by independent certification bodies.
60 6) All users should ensure that they have the latest edition of this publication.
61 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
62 members of its technical committees and IEC National Committees for any personal injury, propert y damage or
63 other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
64 expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC Publications.
65 8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
66 indispensable for the correct application of this publication.
67 9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent
68 rights. IEC shall not be held responsible for identifying any or all such patent rights.
69 The International Standards of the IEC 61810 have been prepared by IEC technical committee
70 94: All-or-nothing electrical relays.
71 The text of this International Standard is based on the following documents:
CD CC
94/799/CD 94/949/CC
73 Full information on the voting for the approval of this International Standard can be found in the
74 report on voting indicated in the above table.
75 This document has been drafted in accordance with the ISO/IEC Directives, Part 2.
76 A list of all parts of IEC 61810 series, published under the general title Electromechanical
77 elementary relays, can be found on the IEC website.

oSIST prEN IEC 61810-7-9:2023
94/953/CDV – 4 – IEC CDV 61810-7-9 © IEC 2023
78 This International Standard is to be used in conjunction with IEC 61810-1:2015 and IEC 61810-
79 7-0:20XX.
80 The committee has decided that the contents of this document will remain unchanged until the
81 stability date indicated on the IEC website under "http://webstore.iec.ch" in the data relate d to
82 the specific document. At this date, the document will be
83 • reconfirmed,
84 • withdrawn,
85 • replaced by a revised edition, or
86 • amended.
oSIST prEN IEC 61810-7-9:2023
IEC CDV 61810-7-9 © IEC 2023 – 5 – 94/953/CDV
89 ELECTROMECHANICAL ELEMENTARY RELAYS –
91 Part 7-9: Climatic tests
95 1 Scope
96 This part of IEC 61810-7 offers methods to determine the ability of the relay to withstand certain
97 climatic test conditions, a sequence of such climatic test conditions or climatic storage
98 conditions.
100 2 Normative references
101 The following documents are referred to in the text in such a way that some or all of their content
102 constitutes requirements of this document. For dated references, only the edition cited applies.
103 For undated references, the latest edition of the referenced document (including any
104 amendments) applies.
105 IEC 60068-2-1:2007, Environmental testing – Part 2: Tests – Tests A: Cold
106 IEC 60068-2-2:2007, Environmental testing – Part 2: Tests – Tests B: Dry heat
107 IEC 60068-2-13:2021, Environmental testing – Part 2: Tests – Test M: Low air pressure
108 IEC 60068-2-30:2005, Environmental testing – Part 2: Tests – Test Db: Damp heat, cyclic (12
109 + 12-hour cycle)
110 IEC 60068-2-78:2012, Environmental testing – Part 2-78: Tests – Test Cab: Damp heat, steady
111 state
112 IEC 61810-1:2015, Electromechanical elementary relays – Part 1: General and safety
113 requirements
114 IEC 61810-7-0:20XX, Electromechanical elementary relays – Part 7-0: Testing general
115 IEC 61810-7-5:20XX, Electromechanical elementary relays – Part 7-5: Insulation resistance
116 IEC 61810-7-6:20XX, Electromechanical elementary relays – Part 7-6: Contact circuit
117 resistance (or voltage drop)
119 3 Terms and definitions
120 Clause 3 of IEC 61810-7-0:20XX is applicable.
oSIST prEN IEC 61810-7-9:2023
94/953/CDV – 6 – IEC CDV 61810-7-9 © IEC 2023
122 4 Test procedure
123 4.1 Purpose
124 To determine the ability of the relay to withstand certain climatic test conditions, or a sequence
125 of such climatic test conditions. For this purpose, the individual climatic tests described under
126 4.2.2 to 4.2.6 hereinafter may be carried out as separate tests. However, when a climatic
127 sequence is required, this sequence shall be as specified below. The damp heat steady state
128 test is to assess the suitability of the relay for use and/or storage under conditions of high
129 relative humidity.
131 4.2 Procedure
132 General
133 A summary of tests, conditions and evaluation details is summarized in Table 1.
135 Table 1 – Summary of tests
Test Standard Duration Conditions At the end of Recovery Final
test time evaluation
Dry Heat test B of 16h 4.3 a)-q) Functional test 1h – 2h Visual
a
IEC 60068-2-2 immediately after inspection
(4.2.2)
test duration at
elevated
temperature
Cold test A or test A of 2h 4.3 a)-q) 200 cycles at 1h – 2h Visual
a b
IEC 60068-2-1 specified coil inspection
(4.2.3)
voltage and load
Low Air test M of 30 min 4.3 a)-q) Dielectric test 1h – 2h Visual
Pressure IEC 60068-2-13 under low inspection
pressure
(4.2.4)
Damp heat test D variant 2 of 12h + 12h, Visual
b 4.3 a)-q) (Recovery) 1h – 2h
Cycle IEC 60068-2-30 number of inspection
cycles as
(4.2.5)
specified
Damp Heat test C IEC 60068- as 4.3 a)-t) (Recovery) 1h – 2h Visual
ab
Steady State 2-78 specified inspection,
insulation
(4.2.6)
resistance,
contact
circuit
resistance
138 Dry heat
139 This test shall be carried out in accordance with test Ba or, if in relation to the test facilities, the
140 relay is to be considered as an appreciably heat-dissipating specimen, with test Bc of
141 IEC 60068-2-2.
142 The duration period shall be 16 h. During the last 2 h of the dry heat exposure time, the relay
143 shall be energized as specified and as follows:
144 a) for relays for continuous duty, the coil voltage shall be applied continuously for the 2 h;

oSIST prEN IEC 61810-7-9:2023
IEC CDV 61810-7-9 © IEC 2023 – 7 – 94/953/CDV
145 b) for relays for short-time or intermittent duty, the coil voltage shall be applied by pulses at
146 the number of cycles per hour and the
...

Questions, Comments and Discussion