Abstract

This part of IEC 62228 specifies test and measurement methods for the EMC evaluation of CXPI transceiver ICs under network condition. It defines test configurations, test conditions, test signals, failure criteria, test procedures, test setups and test boards. This specification is applicable for standard CXPI transceiver ICs and ICs with embedded CXPI transceiver and covers
– the emission of RF disturbances;
– the immunity against RF disturbances;
– the immunity against impulses;
– the immunity against electrostatic discharges (ESD).

Status
Published
Publication Date
10-Sep-2026
Current Stage
6060 - Document made available - Publishing
Start Date
11-Sep-2026
Due Date
13-Feb-2026
Completion Date
13-Feb-2026

Buy Documents

Standard

EN IEC 62228-7:2026 - BARVE

English language (57 pages)
Preview
Preview
e-Library read for
×1 day

EN IEC 62228-7:2026 is a CENELEC European Standard that adopts IEC 62228-7:2026 without modification. It specifies test and measurement methods for EMC evaluation of CXPI transceiver ICs under network conditions, for engineers and test labs working with standard CXPI transceiver ICs and ICs with embedded CXPI transceiver.

What does EN IEC 62228-7:2026 specify?

EN IEC 62228-7:2026 specifies how to evaluate the electromagnetic compatibility (EMC) performance of CXPI transceiver ICs in application-like network conditions. It covers emission of RF disturbances, immunity to RF disturbances, immunity to impulses, and electrostatic discharge (ESD).

Clause 1 sets the scope. Clauses 2 to 7 cover normative references, terms and definitions, general principles, test and operating conditions, test and measurement methods, and the test report. Annexes A to E give the test circuits, PCB guidance, example limits, example signal settings, and notes for impulse testing.

AnnexWhat it covers
Annex ACXPI test circuits for functional tests and unpowered ESD tests
Annex BTest circuit boards for functional and ESD tests
Annex CExample test limits for automotive application
Annex DExample settings for test signals
Annex EPoints to note for impulse immunity measurement for functional status class A

What are the key requirements of EN IEC 62228-7:2026?

EN IEC 62228-7:2026 requires testing in a minimal network, with defined test signals, evaluation criteria, and test setups that match the transceiver type. In practice, the standard is organized so that the same basic approach can be used for RF emission, RF immunity, impulse immunity, and unpowered ESD, while still accounting for the different CXPI transceiver architectures.

Test conditions and network setup

Clause 5 sets default operating conditions around a 12 V automotive-style supply. The functional test conditions use VBAT at 14 V nominal, VCC at 5 V or 3.3 V, and an ambient temperature of 23 °C ± 5 °C. For RF emission measurements, the ambient noise floor must sit at least 6 dB below the target limit and be recorded.

Clause 5.3 requires a minimal two-node CXPI network for powered functional tests. Node 1 is the commander node and Node 2 is the responder node. For unpowered ESD tests, the standard uses one transceiver IC on a separate board. This matters because the test setup is meant to reflect real application behavior, not just component-level behavior.

Test signals and operating modes

Clause 5.4 defines different signals for different transceiver types. TX1 is used for standard type-A, TX2 for standard type-B, TX3 for ICs with embedded CXPI transceiver, and TX4 for wake-up from sleep mode. For the reader, this means the test signal must match the architecture under test or the result is not comparable.

The standard evaluates normal mode and sleep mode. In normal mode, communication is checked. In sleep mode, the test looks for both unwanted wake-up and wanted wake-up behavior. That distinction matters because a device can be electrically quiet yet still react incorrectly to disturbances.

Evaluation criteria and failure detection

Clause 5.5 defines how to decide pass or fail. For powered tests, the document uses functional status classes A, C, D1 or D2 according to IEC 62132-1. For unpowered damage checks, it compares I-V characteristics before and after ESD exposure, and a significant change is treated as failure. In practice, this means the lab must capture reference behavior before the test and compare the same signals or pin characteristics after each step.

RF emission and RF immunity

Clause 6.1 uses the 150 ohm direct coupling method from IEC 61967-4 for RF emission. Measurements are taken on the CXPI and VBAT coupling points, with settings for spectrum analysis and EMI receivers given in the tables. The result is a conducted-emission view of what the transceiver puts onto the network.

Clause 6.2 uses direct RF power injection (DPI) from IEC 62132-4 for RF immunity. The standard defines a frequency sweep from 1 MHz to 1 GHz, with step sizes and forward power levels set in Table 15. For status class A, the lab searches for malfunction while increasing power; for status classes C, D1 or D2, it applies the defined level and checks the status after each test. That difference matters because class A is a threshold search, while the other classes are a fixed-level verification.

Impulse immunity and ESD

Clause 6.3 uses the non-synchronous transient injection method from IEC 62215-3. It applies ISO 7637-2 pulse types 1, 2a, 3a and 3b at the CXPI and VBAT coupling points. The standard also explains how to document impulse immunity levels for the different status classes.

Clause 6.4 uses direct contact discharge from ISO 10605 for ESD testing on an unpowered transceiver. The test starts at 1 kV and goes up in 1 kV steps to the damage level or 15 kV, with positive and negative polarities and three pulses per point. For a buyer or test engineer, this is the part that shows how the device behaves under handling and assembly-related static discharge stress.

What terms does EN IEC 62228-7:2026 define?

EN IEC 62228-7:2026 defines several CXPI-specific terms that are central to the test setups.

  • global pin - a pin that carries a signal or power directly into or out of the application board without active circuitry in between.
  • standard CXPI transceiver IC - a standalone CXPI transceiver according to ISO 20794-4, or an IC with an integrated CXPI transceiver cell that exposes CXPI RXD and TXD.
  • IC with embedded CXPI transceiver - an IC with an integrated CXPI transceiver cell and CXPI protocol handler, with or without external RXD and TXD access.
  • mandatory components - the parts needed for correct operation of the IC, as specified by the manufacturer.
  • commander node - the node that provides schedule management and the primary clock.
  • responder node - any CXPI node other than the commander node.
  • ReqTypeId - the request type identifier used to enable polling for dedicated measurement data or control data.

Who uses EN IEC 62228-7:2026?

EN IEC 62228-7:2026 is used by semiconductor engineers, EMC test laboratories, automotive electronics suppliers, and quality teams that need repeatable EMC evaluation of CXPI transceiver ICs. It is also useful for buyers and technical reviewers who need to compare test evidence from different suppliers on the same basis.

In practice, users apply it to design test boards, set up minimal CXPI networks, run emission and immunity measurements, verify wake-up behavior, and document ESD robustness. It is especially relevant where CXPI is used in road-vehicle electronics and where test reproducibility and comparable limits matter.

What changed in EN IEC 62228-7:2026 from the previous edition?

EN IEC 62228-7:2026 supersedes EN IEC 62228-7:2022 and is described as a technical revision. The foreword states these significant changes:

  • the terms master and slave were changed to commander and responder in 3.1.5 and 3.1.6
  • the test configuration for embedded transceivers was changed in 5.3.1 and Figure A.4 was added accordingly
  • the definition of TX2 for type-B transceivers was changed in 5.4.2
  • examples for test limits were added in Annex C

Which standards are used with EN IEC 62228-7:2026?

EN IEC 62228-7:2026 relies on a set of test and companion standards that define the measurement methods, vehicle disturbance tests, and CXPI protocol context.

  • IEC 61967-1 - general conditions and definitions for integrated-circuit emission measurements
  • IEC 61967-4 - the 1 ohm/150 ohm direct coupling method used for RF emission
  • IEC 62132-1 - general conditions, definitions, and functional status classes for IC immunity
  • IEC 62132-4 - direct RF power injection method for RF immunity
  • IEC 62215-3 - non-synchronous transient injection method for impulse immunity
  • IEC 62228-1 - general conditions and definitions for transceiver EMC evaluation
  • ISO 7637-2 - vehicle transient pulse definitions used for impulse testing
  • ISO 10605 - vehicle ESD test method used for unpowered ESD
  • ISO 20794-4 - CXPI data link layer and physical layer context for the transceiver types and signals
  • ISO 20794-7 - CXPI conformance test plan referenced for embedded-transceiver communication tests
  • EIA-198-1 - capacitor characteristics referenced for passive component selection in the test circuits

The bibliography also points to CISPR 16-1-1, IEC 61000-4-4, and IEC 61000-4-5 as related measurement and pulse references.

What does the EN IEC 62228-7:2026 document contain?

EN IEC 62228-7:2026 contains a complete test framework with tables, figures, and circuit drawings that support EMC evaluation of CXPI transceiver ICs. The body of the standard includes an overview of the required tests, operating conditions, coupling ports, test signals, evaluation criteria, and detailed procedures for RF emission, RF immunity, impulse immunity, and ESD.

Annex A gives functional-test and ESD circuit diagrams for standard type-A, standard type-B, and embedded CXPI transceivers. Annex B gives PCB layout guidance such as two-layer construction, GND layer use, short interconnects, and discharge-point placement. Annex C provides example limits for automotive application, Annex D shows example signal settings, and Annex E explains the special handling of ISO 7637-2 pulse 1 during impulse immunity testing.

Relations

Effective Date
24-Sep-2024
Effective Date
11-Aug-2026
Effective Date
11-Aug-2026
Effective Date
11-Aug-2026
Effective Date
11-Aug-2026
Effective Date
11-Aug-2026
Effective Date
11-Aug-2026
Effective Date
11-Aug-2026
Effective Date
11-Aug-2026

Buy Documents

Standard

EN IEC 62228-7:2026 - BARVE

English language (57 pages)
Preview
Preview
e-Library read for
×1 day

Frequently Asked Questions

EN IEC 62228-7:2026 is a standard published by CLC. Its full title is "Integrated circuits - EMC evaluation of transceivers - Part 7: CXPI transceivers". This standard covers: This part of IEC 62228 specifies test and measurement methods for the EMC evaluation of CXPI transceiver ICs under network condition. It defines test configurations, test conditions, test signals, failure criteria, test procedures, test setups and test boards. This specification is applicable for standard CXPI transceiver ICs and ICs with embedded CXPI transceiver and covers – the emission of RF disturbances; – the immunity against RF disturbances; – the immunity against impulses; – the immunity against electrostatic discharges (ESD).

This part of IEC 62228 specifies test and measurement methods for the EMC evaluation of CXPI transceiver ICs under network condition. It defines test configurations, test conditions, test signals, failure criteria, test procedures, test setups and test boards. This specification is applicable for standard CXPI transceiver ICs and ICs with embedded CXPI transceiver and covers – the emission of RF disturbances; – the immunity against RF disturbances; – the immunity against impulses; – the immunity against electrostatic discharges (ESD).

EN IEC 62228-7:2026 is classified under the following ICS (International Classification for Standards) categories: 31.200 - Integrated circuits. Microelectronics. The ICS classification helps identify the subject area and facilitates finding related standards.

EN IEC 62228-7:2026 has the following relationships with other standards: It is inter standard links to EN IEC 62228-7:2022, EN 62215-3:2013, EN IEC 62228-1:2018, EN IEC 61967-1:2019, EN 62132-1:2016, EN IEC 61967-4:2021, ISO 7637-2:2011, ISO 10605:2008, EN 62132-4:2006. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

EN IEC 62228-7:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms, definitions and abbreviated terms
  • 3.1 Terms and definitions
  • 3.1.1 global pin
  • 3.1.2 standard CXPI transceiver IC
  • 3.1.3 IC with embedded CXPI transceiver
  • 3.1.4 mandatory components
  • 3.1.5 commander node
  • 3.1.6 responder node
  • 3.1.7 ReqTypeId
  • 3.2 Abbreviated terms
  • 4 General
  • 1 TXD
  • 2 RXD
  • 5 CXPI network
  • 11 PMA
  • 5 Test and operating conditions
  • 5.1 Supply and ambient conditions
  • 5.2 Test operation modes
  • 5.3 Test configuration
  • 4 RF connector
  • 5.4 Test signals
  • 5.5 Evaluation criteria
  • 6 Test and measurement
  • 6.1 Emission of RF disturbances
  • 30 MHz to 1 000 MHz: 100 kHz
  • 30 MHz to 1 000 MHz: –
  • 6.2 Immunity to RF disturbances
  • 1 MHz to 10 MHz 0,25 MHz
  • 10 MHz to 100 MHz 1 MHz
  • 6.3 Immunity to impulses
  • 6.4 Electrostatic discharge (ESD)
  • 1 DUT
  • 2 ESD test board
  • 5 ESD generator
  • 6 ESD generator ground return cable
  • 7 Test report
  • Annex A
  • Annex B
  • Annex C
  • Annex D
  • Annex E
  • Bibliography

1 Scope

This part of IEC 62228 specifies test and measurement methods for the EMC evaluation of CXPI transceiver ICs under network condition. It defines test configurations, test conditions, test signals, failure criteria, test procedures, test setups and test boards. This specification is applicable for standard CXPI transceiver ICs and ICs with embedded CXPI transceiver and covers - the emission of RF disturbances; - the immunity against RF disturbances; - the immunity against impulses; - the immunity against electrostatic discharges (ESD).

2 Normative references

The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.

IEC 61967-1, Integrated circuits - Measurement of electromagnetic emissions - Part 1: General conditions and definitions IEC 61967-4, Integrated circuits - Measurement of electromagnetic emissions - Part 4:

Measurement of conducted emissions - 1 Ω/150 Ω direct coupling method IEC 62132-1, Integrated circuits - Measurement of electromagnetic immunity - Part 1: General conditions and definitions IEC 62132-4, Integrated circuits - Measurement of electromagnetic immunity 150 kHz to 1 GHz - Part 4: Direct RF power injection method IEC 62215-3, Integrated circuits - Measurement of impulse immunity - Part 3: Non-synchronous transient injection method IEC 62228-1, Integrated circuits - EMC evaluation of transceivers - Part 1: General conditions and definitions ISO 7637-2, Road vehicles - Electrical disturbances from conduction and coupling - Part 2:

Electrical transient conduction along supply lines only ISO 10605, Road vehicles - Test methods for electrical disturbances from electrostatic discharge ISO 20794-4, Road vehicles - Clock extension peripheral interface (CXPI) - Part 4: Data link layer and physical layer ISO 20794-7, Road vehicles - Clock extension peripheral interface (CXPI) - Part 7: Data link and physical layer conformance test plan EIA‑198-1, Ceramic Dielectric Capacitors Classes I, II, III, and IV - Part 1: Characteristics and Requirements

SIST EN IEC 62228-7:2026

3 Terms, definitions and abbreviated terms

For the purposes of this document, the terms and definitions given in IEC 62228-1, IEC 61967-1 and IEC 62132-1 and the following apply.

ISO and IEC maintain terminology databases for use in standardization at the following addresses:

  • IEC Electropedia: available at https://www.electropedia.org/
  • ISO Online browsing platform: available at https://www.iso.org/obp

3.1 Terms and definitions

3.1.1 global pin

pin that carries a signal or power which enters or leaves the application board without any active component in between

3.1.2 standard CXPI transceiver IC

standalone CXPI transceiver according to ISO 20794-4 or IC with integrated CXPI transceiver cell with access to CXPI RXD and TXD signal

3.1.3 IC with embedded CXPI transceiver

IC with integrated CXPI transceiver cell and CXPI protocol handler, with or without access to CXPI RXD and TXD signal

3.1.4 mandatory components

components needed for proper function of IC as specified by the IC manufacturer

3.1.5 commander node

node that provides schedule management (including ReqTypeId transmission), the primary clock and optionally the sleep message transmission management

3.1.6 responder node

node other than commander node connected to the CXPI network

3.1.7 ReqTypeId

request type identifier, parameter that enables the polling method for dedicated measurement data and/or control data

3.2 Abbreviated terms

ASSP application specific standard product CRC cyclic redundancy check CXPI clock extension peripheral interface DLL data link layer EN enable FI frame information IBS inter byte space NRZ non-return to zero

SIST EN IEC 62228-7:2026

PCB printed circuit board PID protected identifier PMA physical media attachment PS physical signalling RXD receive data TXD transmit data PWM pulse width modulation RX PMA receiver interface signal PWM RXD PS receiver interface signal NRZ TX PMA transmit interface signal PWM TXD PS transmit interface signal NRZ UART universal asynchronous receiver/transmitter V ESD voltage level of ESD testing

4 General

The intention of this document is to evaluate the EMC performance of CXPI transceiver ICs under application conditions in a minimal network. CXPI transceiver ICs are generally classified into three types, as listed in Table 1.

Figure 1 shows a sample configuration of each type of CXPI transceiver IC. The overview of the PHY sublayers follows ISO 20794-4. Standard type-A comprises a CXPI transceiver IC that contains the PS sublayer and the PMA sublayer. Standard type-B contains only the PMA sublayer. The embedded type includes a microcontroller or ASSP function, in addition to the functions of standard type-A. The PMA sublayer transmits and receives communication data on the bus-line in the PWM signal format. The PS sublayer has the clock generation function, the encoding and decoding of CXPI frames and the bit-wise collision resolution logic. The microcontroller or ASSP transmits and receives communication data in the NRZ signal format according to the specifications of the application.

Table 1 – Types for CXPI transceiver Transceiver classification CXPI transceiver type Communication sublayer implementation Standard type-A With PMA and PS sublayer Standard CXPI transceiver IC Standard type-B With PMA sublayer only IC with embedded CXPI transceiver Embedded type With PMA, PS sublayer and DLL

SIST EN IEC 62228-7:2026

Key

1 TXD

NRZ

2 RXD

NRZ 3 TX PWM 4 RX PWM

5 CXPI network

6 clock (commander node only, provided externally or from micro controller) 7 standard type-A 8 standard type-B 9 embedded type 10 PS

11 PMA

12 microcontroller or ASSP etc. including DLL Figure 1 – PHY sub-layers overview and CXPI transceiver types The evaluation of the EMC characteristics of CXPI transceivers shall be performed in functional operation modes under network conditions for RF emission, RF immunity and impulse immunity tests, and on a single unpowered transceiver IC for electrostatic discharge tests. The aim of these tests is to determine the EMC performance on dedicated global pins of the CXPI transceiver that are considered EMC relevant in the application. For a standard CXPI transceiver IC and an IC with an embedded CXPI transceiver, these pins are VBAT and CXPI. The test methods used for EMC characterization are based on the international standards for IC EMC tests and are described in Table 2.

Table 2 – Overview of required measurement and tests Transceiver mode Required test Test method Evaluation Operation mode 150 Ω direct coupling RF emission Spectrum Normal (IEC 61967-4) Normal DPI RF immunity Function Functional (powered) (IEC 62132-4) Sleep Non-synchronous transient Normal injection Impulse immunity Function Sleep (IEC 62215-3) Contact discharge Passive (unpowered) ESD Damage Unpowered (ISO 10605)

SIST EN IEC 62228-7:2026

The RF emission, RF immunity and impulse immunity test methods are selected for the evaluation of EMC characteristic of transceivers in functional (powered) modes. These three test methods are based on the same approach using conductive coupling. Therefore, it is possible to use the same test board for all tests in functional operation mode, which reduces the effort required and increases the reproducibility and comparability of test results. The ESD test is performed on passive (unpowered) transceiver IC on a separate test board. A general drawing of a schematic with details of the CXPI transceiver test network for the targeted EMC tests is described in Annex A. All measurements and tests should be done with soldered transceivers on test boards as described in Annex B, to ensure application like conditions and avoid setup effects by sockets.

Annex C provides example test limits and levels for CXPI transceivers in automotive application. In general, the test definition is done for standard CXPI transceiver ICs. For ICs with embedded CXPI transceivers some adaptations are necessary which are described in this document. Specific adaptations shall be made individually for the dedicated IC but shall follow the general definitions identified.

5 Test and operating conditions

5.1 Supply and ambient conditions

For all tests and measurements under operating conditions, the settings are based on systems with a 12 V power supply, which is the main application for CXPI transceivers. If a transceiver is designed or targeted for a higher power supply voltage, the test conditions and test targets shall be adapted and documented accordingly. The defined supply and ambient conditions for functional operation are given in Table 3. Although the standard voltage of VCC is 5 V, other ext voltages such as 3,3 V can be supplied depending on the product. Table 3 – Supply and ambient conditions for functional operation Parameter Value a (14 ± 0,2) V (default) Voltage supply VBAT ext a (5 ± 0,1) V (default), (3,3 ± 0,1) V Voltage supply VCC ext Test temperature (23 ± 5) °C a V means voltage at external terminal on the test board as shown e.g. in Figure A.1. ext

For RF emission measurements, the ambient noise floor shall be at least 6 dB below the applied target limit and documented in the test report.

Unpowered ESD tests shall be carried out without any supply voltage, and the requirements of ISO 10605 climatic environmental conditions shall be applied.

5.2 Test operation modes

The CXPI transceiver ICs shall be tested in powered functional operation modes and in the unpowered mode. The functional operation modes are normal mode and sleep mode.

SIST EN IEC 62228-7:2026

5.3 Test configuration

5.3.1 General test configuration for functional test

The test configuration in general consists of CXPI transceivers with mandatory components and additional components for filtering and decoupling (CXPI node) in a minimal test network, ext where filtered power supplies, signals, monitoring probes and coupling networks are connected as shown in Figure 2. Node 1 is defined as the commander node, and Node 2 is defined as the responder node.

Figure 2 – General test configuration for tests in functional operation modes For evaluation of RF emission, RF immunity and the impulse immunity characteristics of a CXPI transceiver in functional operation mode, a minimal CXPI test network consisting of two CXPI transceiver ICs shall be used. Depending on the type of transceiver, the following network configurations are defined:

- two transceivers of the same type in case of standard CXPI transceiver IC (DUT), or - one IC with embedded CXPI transceiver (DUT) and one standard CXPI transceiver IC, or two transceivers of the same type of embedded CXPI transceiver IC (DUT). NOTE In specific cases or for analyses, a deviation from this setup can be agreed between the users of this document and noted in the test report.

The CXPI network termination and bus filter including ESD suppression devices (e.g. Zener diode), if used, shall comply with the time constant defined in ISO 20794-4. If an optional ESD suppression device is used (e.g. to achieve a certain ESD or impulse immunity level) it shall be used for all other tests of this document and documented in the test report. A general drawing of a schematic with details of the CXPI transceiver test network for the targeted EMC tests is described in Annex A.

SIST EN IEC 62228-7:2026

5.3.2 General test configuration for unpowered ESD test

The general test configuration for unpowered ESD test of CXPI transceiver ICs consists of a single CXPI transceiver IC with mandatory external components and additional components for filtering and decoupling on a test board with discharge coupling networks as shown in Figure 3.

Figure 3 – General test configuration for unpowered ESD test

5.3.3 Coupling ports and coupling networks for functional tests

The coupling ports and coupling networks are used to transfer disturbances to or from the test network with a defined transfer characteristic. The schematic of the coupling ports, networks and pins are shown in Figure 4. The values of the components depend on the test method and are defined in Table 4. The tolerance of the components should be 1 % or less.

Key 1 coupling ports 2 coupling networks 3 pin networks (including all external mandatory components for the respective pin)

4 RF connector

Figure 4 – Coupling ports and networks for functional tests

SIST EN IEC 62228-7:2026

Table 4 – Definition of coupling ports and coupling network components for functional tests Port Type Purpose Component R , R C , C R , R CP1 CP2 CP1 CP2 CP1t CP2t EMI1 RF emission measurement on CXPI 120 Ω 4,7 nF 51 Ω CP1 RF1 RF coupling for test on CXPI 0 Ω 4,7 nF Not used IMP1 Impulse coupling on CXPI 0 Ω 1,0 nF Not used EMI2 RF emission measurement on VBAT 120 Ω 6,8 nF 51 Ω CP2 RF2 RF coupling for test on VBAT 0 Ω 6,8 nF Not used IMP2 Impulse coupling on VBAT 0 Ω Shorted Not used

The test configurations with coupling ports and coupling networks connected to the CXPI test network are given in the general drawing of schematics in Figure A.1 for standard type-A CXPI transceiver ICs, in Figure A.2 for standard type-B CXPI transceiver ICs and in Figure A.3 and Figure A.4 for ICs with embedded CXPI transceiver.

The characterization of the coupling ports and coupling networks is carried out as follows:

The magnitude of insertion losses (S21) measurement between the ports CP1, CP2 and the respective transceiver signal pads on the test board shall be measured and documented in the test report. For this characterization, the coupling port shall be configured for the RF immunity or emission test, and the CXPI transceiver ICs shall be removed. All other components which are directly connected to the coupling port (e.g. filter to power supply or loads) remain on the test board.

5.3.4 Coupling ports and coupling networks for unpowered ESD tests

The coupling ports and coupling networks used for unpowered direct ESD tests connect the discharge points to the CXPI transceiver IC test circuitry. The schematic and definitions of the coupling ports, networks and pins are given in Figure 5 and Table 5.

Key 1 coupling ports 2 coupling networks 3 pin networks (including all external mandatory components for the respective pin) 4 discharge point Figure 5 – Coupling ports and networks for unpowered ESD tests

SIST EN IEC 62228-7:2026

Table 5 – Definitions of coupling ports for unpowered ESD tests Port Type Purpose Component a CP1 ESD1 ESD coupling on CXPI Metal trace for galvanic connection a CP2 ESD2 ESD coupling on VBAT Metal trace for galvanic connection a The optional resistors R1 and R2 with R ≥ 200 kΩ are used to avoid static pre-charge at the discharge point caused by the ESD generator. Sparking over at these resistors at high test levels shall be avoided. If a static pre-charge is prevented by the ESD generator construction, these resistors are not needed. Alternatively, an external resistor can be used to remove the pre-charge on each discharge point before each single test.

5.3.5 Power supply with decoupling network

In the general test configurations, decoupling circuits shall be added to the supply lines such as VBAT and VCC.

See Annex A for an example of decoupling circuits on a test configuration with two CXPI transceiver ICs.

5.4 Test signals

5.4.1 General

Depending on the transceiver type, different test signals are defined for communication in normal operation mode and wake-up from sleep mode.

5.4.2 Test signals for normal operation mode

The communication test signal TX1 shall be used for testing standard type-A CXPI transceiver ICs in normal operation mode. The communication test signal TX2-1 and TX2-2 shall be used for testing standard type-B CXPI transceiver ICs in normal operation mode. The parameters of these periodical signals are defined in Table 6 and Table 7. An example of setting for test signals is given in Annex D.

Table 6 – Communication test signal TX1 a Test signal TX1 Signal type See Figure 6 Frequency TXD : 10 kHz NRZ Clock: 20 kHz Bit rate 20 kbps Amplitude VCC ± 0,1 V Key t Pulse width of logical value '1' = 50 μs

t Pulse width of logical value '0' = 50 μs

a The TXD of TX1 is input to the transmission data input pin of Node 2 (CXPI responder) and the clock of NRZ TX1 is input to the clock signal input pin of Node 1 (CXPI commander).

SIST EN IEC 62228-7:2026

a Default value = 100 μs. Details are described in ISO 20794-4.

b The clock signal is a square waveform with 50 % duty cycle (default).

The phase difference between TXD and clock is defined for the test purpose. The recommended default value NRZ for the timing difference between the falling edge of TXD and the falling edge of clock is 0 μs. NRZ Figure 6 – Test signal types for standard type-A CXPI transceiver ICs Table 7 – Communication test signal TX2 a Test signal TX2 Signal type See Figure 7 Frequency 20 kHz Bit rate 20 kbps Amplitude VCC ± 0,1 V TX2-1 and TX2-2 timing should be set based on the design specification. Key t Pulse width of logical value '1' = 50 μs

t Pulse width of logical value '0' = 50 μs

t Dominant time of TX2-1 = 12,5 μs (default) 2-1d t Dominant time of TX2-2 to generate logical value '0' = 25 μs (default) 2-2d t Timing delay of TX2-2 to generate logical value '0' = 5 μs (default) 2-2 a The TX2-1 is input to the transmission data input pin of Node 1 (CXPI commander). The TX2-2 is input to the transmission data input pin of Node 2 (CXPI responder).

SIST EN IEC 62228-7:2026

a Default value = 100 μs. Details are described in ISO 20794-4.

Figure 7 – Test signal types for standard type-B CXPI transceiver ICs The communication test signal TX3 shall be used for tests of ICs with embedded CXPI transceiver in normal mode. The signal is defined as a CXPI frame with the parameters given in Table 8 where the embedded CXPI transceiver shall transmit and/or respond depending on its designed or programmed functionality. TX3 signal shall be based on the protocol in ISO 20794-7. The signal is applied as input signal to the commander node. The transmitting and/or responding signal from the responder node is monitored on RX (RXD or RX ) NRZ PWM signal of the commander node. An IC with embedded CXPI transceiver that does not have input/output terminals for communication signals may be used as a commander node if it has a TX3 generation and a CXPI communication diagnostic output as internal function. Table 8 – Communication test signal TX3 Test signal TX3 Signal type CXPI frame a Protocol ISO 20794-7 b Bit rate 20 kbps PID, FI and Data Depending on designed or programmed functionality of the CXPI transceiver IC under test Amplitude VCC ± 0,1 V a Additional testing using other protocol version is possible.

b The given bit data rate is defined as the default. If possible, it should be used for all tests. Optional testing using other bit data rate is possible.

5.4.3 Test signal for wake-up from sleep mode

The wake-up test signal TX4 shall be used for test of wanted wake-up from sleep mode requested by the responder node to the commander node for standard CXPI transceiver ICs. The parameters of this signal are defined in Table 9. It shall be sent only once as a wake-up request.

Depending on the DUT, a second signal with a data frame or longer wake-up request can be necessary to get a data response from the DUT or set the DUT back in sleep mode before the next test. The wake-up test signal applied to a specific transceiver shall meet the definition of ISO 20794-4.

SIST EN IEC 62228-7:2026

...