Industrial communication networks - Profiles - Part 5-3: Installation of fieldbuses - Installation profiles for CPF 3

IEC 61784-5-3:2010(E) specifies the installation profiles for CPF 3 (PROFIBUS/PROFINET). The installation profiles are specified in the annexes. These annexes are read in conjunction with IEC 61918:2010. This second edition cancels and replaces the first edition published in 2007. This edition constitutes a technical revision. It includes the technical changes of the corrigendum for the first edition in 2008 and an addition concerning transmission performance measurement (see Annex C.6.3.2.1.2). This publication is to be read in conjunction with IEC 61918:2010.

Industrielle Kommunikationsnetze - Profile - Teil 5-3: Feldbusinstallation - Installationsprofile für die Kommunikationsprofilfamilie 3

Réseaux de communication industriels - Profils - Partie 5-3: Installation des bus de terrain - Profils d'installation pour CPF 3

Industrijska komunikacijska omrežja - Profili - 5-3. del: Inštalacija procesnih vodil - Inštalacijski profili za CPF 3 (IEC 61784-5-3:2010)

Ta del standarda IEC 61784 določa inštalacijske profile za CPF 3 (PROFIBUS/PROFINET)1. Inštalacijski profili so navedeni v dodatkih. Ti dodatki se navezujejo na standard IEC 61918:2007.

General Information

Status
Withdrawn
Publication Date
19-Apr-2012
Withdrawal Date
18-Oct-2014
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
18-Oct-2016
Completion Date
18-Oct-2016

Relations

Buy Standard

Standard
EN 61784-5-3:2012 - BARVE
English language
107 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-junij-2012
1DGRPHãþD
SIST EN 61784-5-3:2008
Industrijska komunikacijska omrežja - Profili - 5-3. del: Inštalacija procesnih vodil -
Inštalacijski profili za CPF 3 (IEC 61784-5-3:2010)
Industrial communication networks - Profiles - Part 5-3: Installation of fieldbuses -
Installation profiles for CPF 3 (IEC 61784-5-3:2010)
Industrielle Kommunikationsnetze - Profile - Teil 5-3: Feldbusinstallation -
Installationsprofile für die Kommunikationsprofilfamilie 3 (IEC 61784-5-3:2010)
Réseaux de communication industriels - Profils - Partie 5-3: Installation des bus de
terrain - Profils d'installation pour CPF 3 (CEI 61784-5-3:2010)
Ta slovenski standard je istoveten z: EN 61784-5-3:2012
ICS:
25.040.40 Merjenje in krmiljenje Industrial process
industrijskih postopkov measurement and control
35.100.05 9HþVORMQHXSRUDEQLãNH Multilayer applications
UHãLWYH
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD
EN 61784-5-3
NORME EUROPÉENNE
April 2012
EUROPÄISCHE NORM
ICS 25.040.40; 35.100.40 Supersedes EN 61784-5-3:2008

English version
Industrial communication networks -
Profiles -
Part 5-3: Installation of fieldbuses -
Installation profiles for CPF 3
(IEC 61784-5-3:2010)
Réseaux de communication industriels -  Industrielle Kommunikationsnetze -
Profils - Profile -
Partie 5-3: Installation des bus de terrain - Teil 5-3: Feldbusinstallation -
Profils d'installation pour CPF 3 Installationsprofile für die
(CEI 61784-5-3:2010) Kommunikationsprofilfamilie 3
(IEC 61784-5-3:2010)
This European Standard was approved by CENELEC on 2011-10-19. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the CEN-CENELEC Management Centre or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the CEN-CENELEC Management Centre has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,
Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia,
Spain, Sweden, Switzerland, Turkey and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Management Centre: Avenue Marnix 17, B - 1000 Brussels

© 2012 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 61784-5-3:2012 E
Foreword
The text of document 65C/602/FDIS, future edition 2 of IEC 61784-5-3, prepared by SC 65C, "Industrial
networks", of IEC/TC 65, "Industrial-process measurement, control and automation" was submitted to the
IEC-CENELEC parallel vote and approved by CENELEC as EN 61784-5-3:2012.

The following dates are fixed:
(dop) 2012-10-20
• latest date by which the document has
to be implemented at national level by
publication of an identical national
standard or by endorsement
• latest date by which the national (dow) 2014-10-19

standards conflicting with the
document have to be withdrawn
This document supersedes EN 61784-5-3:2008.
C.6.3.2.1.2).
This standard is to be used in conjunction with IEC 61918, second edition (2010-07), together with the
European Common Modification published with EN 61918:2008.

Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such patent
rights.
Endorsement notice
The text of the International Standard IEC 61784-5-3:2010 was approved by CENELEC as a European
Standard without any modification.

- 3 - EN 61784-5-3:2012
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications

The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.

NOTE  When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.
Publication Year Title EN/HD Year

- - Electrical apparatus for potentially explosive EN 50020 -
atmospheres - Intrinsic safety 'i'

IEC 60079-0 2007 Explosive atmospheres - EN 60079-0 2009
+ corr. December 2010 Part 0: Equipment - General requirements

IEC 60079-11 2006 Explosive atmospheres - EN 60079-11 2007
+ corr. December 2006 Part 11: Equipment protection by intrinsic
safety "i"
IEC 60079-27 2008 Explosive atmospheres - EN 60079-27 2008
Part 27: Fieldbus intrinsically safe concept
(FISCO)
IEC 60512-6-3 - Connectors for electronic equipment - Tests EN 60512-6-3 -
and measurements -
Part 6-3: Dynamic stress tests - Test 6c:
Shock
IEC 60512-6-4 - Connectors for electronic equipment - Tests EN 60512-6-4 -
and measurements -
Part 6-4: Dynamic stress tests - Test 6d:
Vibration (sinusoidal)
1)
IEC 60793-2-10 2007 Optical fibres - EN 60793-2-10 2007
Part 2-10: Product specifications - Sectional
specification for category A1 multimode fibres

IEC 60793-2-50 2008 Optical fibres - EN 60793-2-50 2008
Part 2-50: Product specifications - Sectional
specification for class B single-mode fibres

IEC 61000-4-2 2008 Electromagnetic compatibility (EMC) - EN 61000-4-2 2009
Part 4-2: Testing and measurement
techniques - Electrostatic discharge immunity
test
IEC 61076-2-107 2010 Connectors for electronic equipment - Product EN 61076-2-107 2010
requirements -
Part 2-107: Detail specification for circular
hybrid connectors M12 with electrical and
fibre-optic contacts with screw-locking

IEC 61156-5 2009 Multicore and symmetrical pair/quad cables - -
+ corr. May 2009 for digital communications -
+ corr. February 2010 Part 5: Symmetrical pair/quad cables with
transmission characteristics up to 1 000 MHz -
Horizontal floor wiring - Sectional specification

1)
EN 60793-2-10 is superseded by EN 60793-2-10:2011, which is based on IEC 60793-2-10:2011.

Publication Year Title EN/HD Year

IEC 61508 Series Functional safety of EN 61508 Series
electrical/electronic/programmable electronic
safety-related systems
IEC 61754-24-11 - Fibre optic interconnecting devices and EN 61754-24-11 -
passive components - Fibre optic connector
interfaces -
Part 24-11: Type SC-RJ connectors with
protective housings based on
IEC 61076-3-117
IEC 61918 2010 Industrial communication networks - - -
Installation of communication networks in
industrial premises
ANSI TIA/EIA-485-A - Electrical Characteristics of Generators and - -
Receivers for Use in Balanced Digital
Multipoint Systems
IEC 61784-5-3 ®
Edition 2.0 2010-07
INTERNATIONAL
STANDARD
colour
inside
Industrial communication networks – Profiles –
Part 5-3: Installation of fieldbuses – Installation profiles for CPF 3

INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
PRICE CODE
XD
ICS 25.040.40; 35.100.40 ISBN 978-2-88912-056-7
– 2 – 61784-5-3 © IEC:2010(E)
CONTENTS
FOREWORD.5
INTRODUCTION.7
1 Scope.8
2 Normative references .8
3 Terms, definitions and abbreviated terms .8
4 CPF 3: Overview of installation profiles .8
5 Installation profile conventions .9
6 Conformance to installation profiles.9
Annex A (normative) CP 3/1 (PROFIBUS) specific installation profile.11
Annex B (normative)  CP 3/2 (PROFIBUS) specific installation profile.43
Annex C (normative) CP 3/3, CP 3/4, CP 3/5, CP 3/6 (PROFINET) specific installation
profile .77
Bibliography.103

Figure 1 – Standards relationships.7
Figure A.1 – Recommended combination of shielding and earthing for CP 3/1
networks with RS 485-IS.24
Figure A.2 – Sub-D connector pin numberings (front view).29
Figure A.3 – 5-pin M-12 female socket.30
Figure A.4 – 5 pins M-12 male plug for CP 3/1.31
Figure A.5 – Test circuit A - resistance measurement of data line B and shield.36
Figure A.6 – Test circuit B - resistance measurement of data line A and shield.37
Figure A.7 – Test circuit C - resistance measurement of data line A, data line B, and
shield.37
Figure A.8 – Test circuit D - resistance measurement between data line A and B .38
Figure A.9 – Resistance measurement without 9-pin Sub-D plug .38
Figure A.10 – Loop core resistance (cable type A) .39
Figure A.11 – Action and resolution tree for measurement 1 (RS 485 and RS 485-IS) .40
Figure A.12 – Action and resolution tree for measurement 2 (RS 485 and RS 485-IS) .41
Figure A.13 – Action and resolution tree for measurement 3 (RS 485 and RS 485-IS) .41
Figure B.1 – Connection of CP 3/1 networks.46
Figure B.2 – Typical fieldbus architecture .48
Figure B.3 – Fieldbus with stations supplied by auxiliary power sources .49
Figure B.4 – Fieldbus model .51
Figure B.5 – Current modulation (Manchester II code) .52
Figure B.6 – Tree topology .53
Figure B.7 – Bus topology.54
Figure B.8 – Combination of the tree topology and the bus topology .54
Figure B.9 – Fieldbus extension.55
Figure B.10 – Recommended combination of shielding and earthing.67
Figure B.11 – Ideal combination of shielding and earthing .69
Figure B.12 – Capacitive earthing .70
Figure B.13 – Galvanic isolated field device.71

61784-5-3 © IEC:2010(E) – 3 –
Figure B.14 – Pin assignment of the male and female connectors IEC 60947-5-2 (A-
coding) .74
Figure C.1 – End-to-end link without interconnections.90
Figure C.2 – Assembled end-to-end link .90
Figure C.3 – Connectionless optical fibre link .91
Figure C.4 – Assembled optical fibre link .91
Figure C.5 – Shielded connectors for CP 3/3, CP 3/4, CP 3/5 and CP 3/6 fieldbus
networks .97
Figure C.6 – Pin-assignment for a straight cable.97

Table A.1 – Excerpt of MICE definition.13
Table A.2 – Basic
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.