Fibre management systems and protective housings to be used in optical fibre communication systems - Product specifications - Part 3-1: Wall or pole mounted box for splices, for category C and A

1.1 Product definition This document contains the dimensional, optical, mechanical and environmental performance requirements of a fully installed optical fibre wall or pole mounted box for up to 288 fibre splices, in order for it to be categorized as a European standard product. The typical configuration is splicing of incoming fibres to optional splitters, connecting on the other side to outgoing fibres. A box is a protective housing containing a fibre management system with splice trays of various fibre separation levels. The box can contain one or more of the following: - storage and routing for fibre and cable; - uncut fibre cable storage; - splice trays; - passive optical devices (optical splitters or WDM). A box can be installed on a vertical indoor or outdoor surface above ground level. If the box is required to be relocatable with cables attached, the following additional tests are expected to be performed: - cable bending; - cable torsion. This document specifies the number of splice trays and splice capacity for each fibre separation level. The maximum capacity is 288 splices. For housings with a higher number of splices, EN 50411 4 1 (street cabinets) can be used. Boxes for fibre splice and patchcord connections are covered in EN 50411 3 4. 1.2 Operating environment The tests selected, combined with the severity and duration, are representative of indoor and outside plant for above ground environments defined by EN IEC 61753 1: - category C: Controlled (indoor) environment; - category A: Aerial (outdoor above ground) environment. 1.3 Reliability Whilst the anticipated service life expectancy of the product in this environment is 20 years, compliance with this document does not guarantee the reliability of the product. This is expected to be predicted using a recognized reliability assessment programme. 1.4 Quality assurance Compliance with this document does not guarantee the manufacturing consistency of the product. This is expected to be maintained using a recognized quality assurance programme. 1.5 Allowed fibre and cable types This box standard accommodates EN IEC 60793 2 50 single-mode fibres and EN IEC 60793 2 10 A1-OM2 to A1-OM5 and A1-OM1 multimode fibres and all EN 60794 series optical fibre cables with various fibre capacities, types and designs.

LWL-Spleißkassetten und -Muffen für die Anwendung in LWL-Kommunikationssystemen - Produktnormen - Teil 3-1: Faser Management System, Wandspleißverteiler für die Kategorien C und A

Systèmes de gestion des fibres et boîtiers de protection destinés à être utilisés dans les systèmes de communication par fibres optiques - Spécifications de produits - Partie 3-1: Boîte de montage mural ou sur poteau pour les épissures, pour les catégories C et A

1.1 Définition du produit Le présent document contient les exigences de performance dimensionnelles, optiques, mécaniques et environnementales d’une boîte de fibres optiques murale ou montée sur poteau, entièrement installée, capable d’accueillir jusqu’à 288 épissures de fibres, ces exigences lui permettant d’être catégorisée comme produit à la norme européenne. La configuration type comprend l’épissurage de fibres entrantes sur des répartiteurs facultatifs, raccordées de l’autre côté sur des fibres sortantes. Une boîte est un coffret de protection contenant un système de gestion de fibres équipé de plateaux d’épissures offrant différents niveaux de séparation de fibres. La boîte peut offrir une ou plusieurs des fonctions suivantes: - stockage et acheminement pour les fibres et les câbles; - stockage de câble de fibres non découpées; - plateaux d’épissures; - dispositifs optiques passifs (répartiteurs optiques ou WDM). Une boîte peut être installée sur une surface intérieure ou extérieure verticale, au-dessus du niveau du sol. S’il est exigé que la boîte puisse être déplacée avec ses câbles déjà fixés, les essais supplémentaires suivants sont censés être effectués: - courbure de câble; - torsion de câble. Le présent document spécifie le nombre de plateaux d’épissures et la capacité en épissures pour chaque niveau de séparation de fibres. La capacité maximale est de 288 épissures. Pour les coffrets contenant davantage d’épissures, l’EN 50411-4-1 (baies urbaines) peut être utilisée. Les boîtes destinées aux raccordements d’épissures de fibres et de cordons de brassage sont traitées dans l’EN 50411-3-4. 1.2 Environnement de fonctionnement Les essais sélectionnés, combinés aux sévérités et aux durées, sont représentatifs d’une installation intérieure et extérieure au-dessus du niveau du sol définie par l’EN IEC 61753-1: - catégorie C: Environnement contrôlé (intérieur); - catégorie A: Environnement aérien (extérieur au-dessus du niveau du sol). 1.3 Fiabilité Tandis que l’espérance de vie du produit en service prévue dans cet environnement est de 20 ans, la conformité au présent document ne garantit pas la fiabilité du produit. Il est attendu que celle-ci soit estimée en utilisant un programme reconnu d’évaluation de la fiabilité. 1.4 Assurance de la qualité La conformité au présent document ne garantit pas la cohérence de fabrication du produit. Il est attendu qu’elle soit suivie au moyen d’un programme reconnu d’assurance de la qualité. 1.5 Types de fibres et câbles autorisés La présente norme concernant les boîtes contient l’EN IEC 60793-2-50 sur les fibres unimodales et l’EN IEC 60793-2-10 A1-OM2 à A1-OM5 et A1-OM1 sur les fibres multimodales et toute la série EN 60794 sur les câbles à fibres optiques avec différentes capacités de fibre, différents types et différentes conceptions.

Sistemi za upravljanje z optičnimi vlakni in zaščitna ohišja za optične komunikacijske sisteme - Specifikacije izdelka - 3-1. del: Sistem za upravljanje optičnih elementov, stenska omarica s spojnicami, za kategoriji C in G

General Information

Status
Published
Publication Date
30-Oct-2025
Withdrawal Date
07-Dec-2022
Current Stage
6060 - Document made available - Publishing
Start Date
31-Oct-2025
Due Date
15-Jul-2022
Completion Date
31-Oct-2025

Relations

Draft
prEN 50411-3-1:2021
English language
36 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
oSIST prEN 50411-3-1:2021
01-april-2021
Sistemi za upravljanje z optičnimi vlakni in zaščitna ohišja za optične
komunikacijske sisteme - Specifikacije izdelka - 3-1. del: Sistem za upravljanje
optičnih elementov, stenska omarica s spojnicami, za kategoriji C in G
Fibre management systems and protective housings to be used in optical fibre
communication systems - Product specifications - Part 3-1: Fibre management system,
splice wall box, for category C & G
Systèmes de gestion des fibres et boîtiers de protection destinés à être utilisés dans les
systèmes de communication par fibres optiques - Spécifications de produits - Partie 3-1:
Boîte de montage mural ou sur poteau pour les épissures, pour les catégories C et A
Ta slovenski standard je istoveten z: prEN 50411-3-1
ICS:
33.180.20 Povezovalne naprave za Fibre optic interconnecting
optična vlakna devices
oSIST prEN 50411-3-1:2021 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

oSIST prEN 50411-3-1:2021
oSIST prEN 50411-3-1:2021
EUROPEAN STANDARD DRAFT
prEN 50411-3-1
NORME EUROPÉENNE
EUROPÄISCHE NORM
January 2021
ICS  Will supersede EN 50411-3-1:2012 and all of its
amendments and corrigenda (if any)
English Version
Fibre management systems and protective housings to be used
in optical fibre communication systems - Product specifications -
Part 3-1: Fibre management system, splice wall box, for
category C & G
Systèmes de gestion des fibres et boîtiers de protection To be completed
destinés à être utilisés dans les systèmes de
communication par fibres optiques - Spécifications de
produits - Partie 3-1: Boîte de montage mural ou sur poteau
pour les épissures, pour les catégories C et A
This draft European Standard is submitted to CENELEC members for enquiry.
Deadline for CENELEC: 2021-04-23.

It has been drawn up by CLC/TC 86BXA.

If this draft becomes a European Standard, CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which
stipulate the conditions for giving this European Standard the status of a national standard without any alteration.

This draft European Standard was established by CENELEC in three official versions (English, French, German).
A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to
the CEN-CENELEC Management Centre has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the
Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.

Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are aware and to
provide supporting documentation.

Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without notice and
shall not be referred to as a European Standard.

European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2021 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Project: 68680 Ref. No. prEN 50411-3-1 E

oSIST prEN 50411-3-1:2021
prEN 50411-3-1:2021 (E)
1 Contents Page
2 European foreword .4
3 1 Scope .6
4 1.1 Product definition .6
5 1.2 Operating environment .6
6 1.3 Reliability .6
7 1.4 Quality assurance .6
8 1.5 Allowed fibre and cable types .6
9 2 Normative references .7
10 3 Terms and definitions .8
11 4 Abbreviations . 10
12 5 Description . 10
13 5.1 Functions and configurations . 10
14 5.2 Cable seals . 11
15 5.3 Cable anchoring . 12
16 5.4 Fibre management system . 12
17 5.5 Passive optical components . 12
18 5.6 Materials . 12
19 5.7 Marking and identification . 13
20 6 Variants . 13
21 7 Dimensional requirements . 15
22 8 Tests . 16
23 8.1 Sample size . 16
24 8.2 Test sample preparation . 16
25 8.2.1 Fibre type for test samples . 16
26 8.2.2 Sealing performance test samples for boxes . 16
27 8.2.3 Optical performance test samples for boxes . 16
28 8.2.4 Test sample configuration for track or spur boxes . 17
29 8.2.5 Test sample configuration for distribution boxes . 17
30 8.3 Test and measurement methods . 18
31 8.4 Test sequence . 19
32 8.5 Pass/fail criteria . 19
33 9 Test report . 19
34 10 Performance requirements . 19
35 10.1 Dimensional and marking requirements . 19
36 10.2 Sealing, optical and appearance acceptance criteria . 19
37 10.3 Mechanical sealing performance requirements . 21
38 10.4 Environmental sealing performance requirements . 23
39 10.5 Mechanical optical performance requirements . 23
40 10.6 Environmental optical performance requirements . 26
41 10.7 Material requirements . 26
42 Annex A (normative) Fibre details for the test samples . 28
43 Annex B (normative) Sample size requirements . 29
44 Annex C (informative) Families of FMS covered in this document . 31
oSIST prEN 50411-3-1:2021
prEN 50411-3-1:2021 (E)
45 Annex D (informative) Dimensions of FMS for multiple element and multiple ribbon . 33
46 Annex E (informative) Dimensions of S type FMS for Single Circuit, Single Element and
47 Single Ribbon . 34
48 Bibliography . 36
49 Figures
50 Figure 1 — Fibre management configurations in a track box . 11
51 Figure 2 — Dimensions of optical fibre splice boxes . 15
52 Figure 3 — Example configuration of track or spur box test sample. 17
53 Figure 4 — Example configuration of distribution box test sample . 18
54 Figure C.1 — Families of FMS covered in this document . 32
55 Figure D.1 — Outline dimensions of the M type FMS . 33
56 Figure E.1 — Outline dimensions of the S type FMS . 34
58 Tables
59 Table 1 — Optical fibre splice box, for category C and A - variants. 13
60 Table 2 — Box size selection . 14
61 Table 3 — Optical fibre splice box dimensions . 16
62 Table 4 — Sealing, optical and appearance acceptance criteria . 19
63 Table 5 — Mechanical sealing performance requirements . 21
64 Table 6 — Environmental sealing performance requirements . 23
65 Table 7 — Mechanical optical performance requirements . 23
66 Table 8 — Environmental optical performance requirements . 26
67 Table 9 — Material requirements . 26
68 Table A.1 — Fibre references for EN IEC 60793-2-50, sub-category B-652.D . 28
69 Table A.2 — Fibre references for EN IEC 60793-2-50, sub-category B-657.A1 . 28
70 Table B.1 — Minimum sample size requirements . 29
71 Table D.1 — M type FMS - Multiple element and multiple ribbon fibre . 33
72 Table E.1 — Outline dimensions of S type FMS . 35
73 Table E.2 — Maximum capacity S type FMS - SC, SE and SR . 35
oSIST prEN 50411-3-1:2021
prEN 50411-3-1:2021 (E)
75 European foreword
76 This document (prEN 50411-3-1:2021) has been prepared by CLC/TC 86BXA “Fibre optic interconnect,
77 passive and connectorised components”.
78 This document is currently submitted to the Enquiry.
79 The following dates are proposed:
• latest date by which the existence of this (doa) dor + 6 months
document has to be announced at national
level
• latest date by which this document has to be (dop) dor + 12 months
implemented at national level by publication of
an identical national standard or by
endorsement
• latest date by which the national standards (dow) dor + 12 months
conflicting with this document have to be (to be confirmed or
withdrawn modified when voting)
80 This document will supersede EN 50411-3-1:2012 and all of its amendments and corrigenda (if any).
81 prEN 50411-3-1:2021 includes the following significant technical changes with respect to
82 EN 50411-3-1:2012:
83 — update of the product category in title to Fibre management systems and protective housings;
84 — update of the product type in title to wall or pole mounted box for splices;
85 — addition of the application for pole mounting;
86 — update of the environmental categories to C and A according to EN IEC 61753-1:2018 ed2;
87 — update of the definition according to EN IEC 61753-1:2018;
88 — update of the description similar to EN 50411-3-4;
89 — replacement of the seven tables with box sizes, number of trays and splice capacity with one table
90 reducing the number of sizes to seven
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.