Information technology - Premises distribution access network (PDAN) cabling to support deployment of optical broadband networks

This European Standard specifies the optical fibre access network cabling within multi-subscriber premises (which may comprise single or multiple buildings) and intended to support deployment of optical broadband networks. The cabling within the subscriber space for onward distribution of services beyond the customer premises equipment is not specified. Cabling defined by this standard supports a wide range of broadband applications delivering services including voice, data, text, image and video. This European Standard specifies: a) the structure and configuration of the optical fibre cabling; b) cabling performance requirements; c) implementation options. Safety (electrical safety, optical safety and protection, fire, etc.) and electromagnetic compatibility (EMC) requirements are outside the scope of this European Standard and are covered by other standards and regulations. However, information given in this European Standard may be of assistance in meeting these standards and regulations.

Informationstechnik - Standortverkabelung als Teil des optischen Zugangsnetzes von optischen Breitbandnetzen

Diese Europäische Norm legt die Verkabelung von Zugangsnetz en mit Lichtwellenleitern an Standorten mit mehreren Teilnehmern (welche eines oder mehrere Gebäude umfassen dürfen) und ist vorgesehen, die Verwendung optischer Breitbandnetze zu unterstützen. Die Verkabelung im Teilnehmerbereich zur Weiterverteilung der Dienste über die Standorteinrichtungen hinaus wird nicht festgelegt. Die in dieser Norm festgelegte Verkabelung unterstützt einen weiten Bereich von breitbandigen Netz-anwendungen, welche Dienste einschließlich Sprache, Daten, Text, Bild und Film bereitstellen. Diese Europäische Norm legt fest: a) die Struktur und die Konfiguration der Lichtwellenleiterverkabelung; b) Anforderungen an die Leistungsfähigkeit der Verkabelung; c) Wahlmöglichkeiten für die Ausführung. Anforderungen an Sicherheit (elektrische Sicherheit und Schutz vor Zerstörung, optische Leistung, Feuer usw.) und elektromagnetische Verträglichkeit (EMV) gehören nicht zum Anwendungsbereich dieser Europä-ischen Norm und werden von anderen Normen und Vorschriften behandelt. Jedoch kann die in dieser Euro-päischen Norm gegebene Information bei der Einhaltung dieser Normen und Vorschriften hilfreich sein.

Technologie de l'information - Câblage du réseau de distribution privé du réseau d’accès dans les locaux (PDAN) supportant le déploiement des réseaux optiques à large bande

Informacijska tehnologija - Okabljenje prostorov z distribucijskim dostopovnim omrežjem v podporo gradnji optičnih širokopasovnih omrežij

General Information

Status
Published
Publication Date
09-Jan-2014
Withdrawal Date
24-Nov-2016
Current Stage
9093 - Decision to confirm - Review Enquiry
Completion Date
19-Sep-2018

Relations

Buy Standard

Standard
EN 50700:2014
English language
28 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-marec-2014
,QIRUPDFLMVNDWHKQRORJLMD2NDEOMHQMHSURVWRURY]GLVWULEXFLMVNLPGRVWRSRYQLP
RPUHåMHPYSRGSRURJUDGQMLRSWLþQLKãLURNRSDVRYQLKRPUHåLM
Information technology - Premises distribution access network (PDAN) cabling to support
deployment of optical broadband networks
Informationstechnik - Verkabelung für die Verteilung von Zugangsnetzen an Standorten
zur Unterstützung von optischen Breitbandnetzen
Ta slovenski standard je istoveten z: EN 50700:2014
ICS:
35.110 Omreževanje Networking
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD
EN 50700
NORME EUROPÉENNE
January 2014
EUROPÄISCHE NORM
ICS 35.110
English version
Information technology -
Premises distribution access network (PDAN) cabling to support
deployment of optical broadband networks

Technologie de l'information -  Informationstechnik -
Câblage du réseau de distribution dans Standortverkabelung als Teil des
les locaux (PDAN) pour prendre en optischen Zugangsnetzes von optischen
charge le déploiement de réseaux Breitbandnetzen
optiques à large bande
This European Standard was approved by CENELEC on 2013-11-25. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the CEN-CENELEC Management Centre or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the CEN-CENELEC Management Centre has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany,
Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland,
Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

CEN-CENELEC Management Centre: Avenue Marnix 17, B - 1000 Brussels

© 2014 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 50700:2014 E
Contents Page
Foreword . 4
Introduction . 5
1 Scope . 9
2 Normative references. 9
3 Terms, definitions and abbreviations . 10
3.1 Terms and definitions . 10
3.2 Abbreviations . 12
4 Conformance . 13
5 Structure of PDAN cabling within multi-subscriber premises . 14
5.1 General . 14
5.2 Functional elements. 14
5.3 General structure and hierarchy . 14
5.4 Cabling subsystems . 15
5.5 Design objectives . 16
5.6 Accommodation of functional elements . 16
5.7 Interfaces . 17
5.8 Dimensioning and configuring . 18
6 PDAN cabling performance . 21
6.1 General . 21
6.2 Environmental performance . 21
6.3 Transmission performance . 21
7 Implementation options . 22
8 Cable requirements . 22
8.1 General . 22
8.2 Cable . 23
8.3 Microducts . 23
8.4 Microduct optical fibre . 23
9 Connecting hardware requirements . 23
9.1 General requirements . 23
9.2 Connecting hardware at the SI . 23
9.3 Connecting hardware at other places . 24
10 Cords . 24
11 Accommodation of the Subscriber Interface (SI) and the Customer Premises Equipment (CPE)24
11.1 Security for data integrity . 24
11.2 Placement of the housing . 25
Annex A (informative) Broadband infrastructure external to multi-subscriber premises . 26

- 3 - EN 50700:2014
A.1 General . 26
A.2 Treatment of single-subscriber premises . 26
A.3 Treatment of multi-subscriber premises . 26
Bibliography . 28

Figures
Figure 1  Multi-subscriber PDAN cabling (LOC external to the premises) . 6
Figure 2  Example of multi-subscriber PDAN cabling (LOC internal to the premises) . 6
Figure 3  Schematic relationship between EN 50700 and other relevant TC 215 standards . 7
Figure 4  PDAN cabling distribution schematic with ADP (and future LOC) internal to multi-
subscriber building . 14
Figure 5  PDAN cabling distribution schematic with ADP (and future LOC) internal to premises . 15
Figure 6  PDAN cabling distribution schematic with future LOC external to premises . 15
Figure 7  Example of accommodation of functional elements. 17
Figure 8  Test and equipment interfaces . 18
Figure 9  SI connection to the customer network . 19
Figure 10  Examples of arrangements of SI, OAP and ENTI . 20
Figure 11  Examples of SI configuration of passive PDAN cabling . 21
Figure A.1  Broadband optical fibre cabling to subscriber premises . 26

Tables
Table 1  Contextual relationship between EN 50700 and other relevant TC 215 standards . 8
Table 2  PDAN cabling attenuation . 22

Foreword
This document (EN 50700:2014) has been prepared by CLC/TC 215 "Electrotechnical aspects of
telecommunication equipment".
The following dates are fixed:
• latest date by which this document has to be
(dop) 2014-11-25
implemented at national level by publication of
an identical national standard or by
endorsement
• latest date by which the national standards
(dow) 2016-11-25
conflicting with this document have to
be withdrawn
This document has been developed to enable the application of system-independent pre-cabling of multi-
subscriber premises to enable the delivery of broadband telecommunication services.

- 5 - EN 50700:2014
Introduction
Fibre to the home (FTTH) is the subject of standardisation in the form of:
• Technical Reports such as CLC/TR 50510 which cover general concepts and system planning;
• component standards that support its implementation;
• installation standards such as the EN 50174 series.
FTTH is a general term applied to the provision of broadband optical networks to residential premises. Some
premises accommodate multiple subscribers and these may be residential or commercial enterprises such
as offices, data centres, industrial, retail or a mix of these subscriber types. These multi-subscriber premises
may consist of one or more buildings.
The cabling specified in this standard:
− constitutes the part of the broadband access network within multi-subscriber premises termed the
premises distribution access network (PDAN); the access network serving single subscriber premises is
not normatively addressed in this standard;
− is intended to be pre-installed, in readiness for subsequent connection of the multi-subscriber premises,
to an access provider’s infrastructure to an access demarcation point (ADP) - enabling broadband
content to be delivered by the service provider(s).
Within premises, the importance of the information technology cabling infrastructure is similar to that of other
fundamental building utilities such as heating, lighting and mains power. As with other utilities, interruptions
to service can have a serious impact. Poor quality of service due to lack of design foresight, use of
inappropriate components, incorrect installation, poor administration or inadequate support can disrupt
service delivery.
This standard:
− allows access providers to be aware of the minimum implementation delivered to them when they reach
such multi-subscriber premises;
− maximises the opportunity for network evolution by either the access provider or the service providers
using that access infrastructure.
This standard specifies the cabling between the access demarcation point (ADP) and the subscriber
interface (SI).The transmission performance of the premises cabling between the last operator connection
point (LOC) and the ADP is not addressed although the requirements for its accommodation are provided by
external reference to the EN 50174 series. The location of the LOC may be either outside the premises
boundary (see the schematic in Figure 1) or inside the premises, internal or external to a building (see the
schematic in Figure 2).
Transport access
Distribution access network
network
Premises boundary
Multi-subscriber
building
SI
SI
Premises
SI
entrance
ADP
One or
more
LOC
operators
Multi-building
sites
SI
subscriber
ADP
Premises
SI
entrance
Cabling within scope of this
standard
.
Figure 1  Multi-subscriber PDAN cabling (LOC external to the premises)
Transport access network Distribution
access network
Premises boundary
Multi-subscriber
building
SI
SI
One or
SI
more
LOC ADP
operators
sites
Multi-building
One or SI
subscriber
more
LO
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.