SIST EN 50700:2014
(Main)Information technology - Premises distribution access network (PDAN) cabling to support deployment of optical broadband networks
Information technology - Premises distribution access network (PDAN) cabling to support deployment of optical broadband networks
EN 50700 specifies the optical fibre optical fibre access network cabling within multi-subscriber premises termed the premises distribution access network (PDAN). The premises may comprise single or multiple buildings. The cabling specified is intended to be pre-installed, in readiness for subsequent connection of the multi-subscriber premises to an access providers infrastructure to support deployment of optical broadband networks. This European Standard does not specify either the access network cabling external to the premises or the cabling within the subscriber space for onward distribution of services beyond the customer premises equipment. This European Standard specifies: a) the structure and configuration of the optical fibre cabling; b) cabling performance requirements; c) implementation options. Safety practices in relation to optical power hazard are specified in EN 60825-2. Optical powers higher than the hazard levels specified in EN 60825-2 are not considered in this standard. Safety (electrical safety, fire, etc.) and electromagnetic compatibility (EMC) requirements are outside the scope of this European Standard and are covered by other standards and regulations. However, information given in this European Standard may be of assistance in meeting these standards and regulations.
Informationstechnik - Verkabelung für die Verteilung von Zugangsnetzen an Standorten zur Unterstützung von optischen Breitbandnetzen
Diese Europäische Norm legt die Verkabelung von Zugangsnetz en mit Lichtwellenleitern an Standorten mit mehreren Teilnehmern (welche eines oder mehrere Gebäude umfassen dürfen) und ist vorgesehen, die Verwendung optischer Breitbandnetze zu unterstützen. Die Verkabelung im Teilnehmerbereich zur Weiterverteilung der Dienste über die Standorteinrichtungen hinaus wird nicht festgelegt.
Die in dieser Norm festgelegte Verkabelung unterstützt einen weiten Bereich von breitbandigen Netz-anwendungen, welche Dienste einschließlich Sprache, Daten, Text, Bild und Film bereitstellen.
Diese Europäische Norm legt fest:
a) die Struktur und die Konfiguration der Lichtwellenleiterverkabelung;
b) Anforderungen an die Leistungsfähigkeit der Verkabelung;
c) Wahlmöglichkeiten für die Ausführung.
Anforderungen an Sicherheit (elektrische Sicherheit und Schutz vor Zerstörung, optische Leistung, Feuer usw.) und elektromagnetische Verträglichkeit (EMV) gehören nicht zum Anwendungsbereich dieser Europä-ischen Norm und werden von anderen Normen und Vorschriften behandelt. Jedoch kann die in dieser Euro-päischen Norm gegebene Information bei der Einhaltung dieser Normen und Vorschriften hilfreich sein.
Technologie de l'information - Câblage du réseau de distribution privé du réseau d’accès dans les locaux (PDAN) supportant le déploiement des réseaux optiques à large bande
Informacijska tehnologija - Okabljenje prostorov z distribucijskim dostopovnim omrežjem v podporo gradnji optičnih širokopasovnih omrežij
General Information
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN 50700:2014
01-marec-2014
,QIRUPDFLMVNDWHKQRORJLMD2NDEOMHQMHSURVWRURY]GLVWULEXFLMVNLPGRVWRSRYQLP
RPUHåMHPYSRGSRURJUDGQMLRSWLþQLKãLURNRSDVRYQLKRPUHåLM
Information technology - Premises distribution access network (PDAN) cabling to support
deployment of optical broadband networks
Informationstechnik - Verkabelung für die Verteilung von Zugangsnetzen an Standorten
zur Unterstützung von optischen Breitbandnetzen
Ta slovenski standard je istoveten z: EN 50700:2014
ICS:
35.110 Omreževanje Networking
SIST EN 50700:2014 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST EN 50700:2014
---------------------- Page: 2 ----------------------
SIST EN 50700:2014
EUROPEAN STANDARD
EN 50700
NORME EUROPÉENNE
January 2014
EUROPÄISCHE NORM
ICS 35.110
English version
Information technology -
Premises distribution access network (PDAN) cabling to support
deployment of optical broadband networks
Technologie de l'information - Informationstechnik -
Câblage du réseau de distribution dans Standortverkabelung als Teil des
les locaux (PDAN) pour prendre en optischen Zugangsnetzes von optischen
charge le déploiement de réseaux Breitbandnetzen
optiques à large bande
This European Standard was approved by CENELEC on 2013-11-25. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the CEN-CENELEC Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the CEN-CENELEC Management Centre has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany,
Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland,
Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B - 1000 Brussels
© 2014 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 50700:2014 E
---------------------- Page: 3 ----------------------
SIST EN 50700:2014
EN 50700:2014 - 2 -
Contents Page
Foreword . 4
Introduction . 5
1 Scope . 9
2 Normative references. 9
3 Terms, definitions and abbreviations . 10
3.1 Terms and definitions . 10
3.2 Abbreviations . 12
4 Conformance . 13
5 Structure of PDAN cabling within multi-subscriber premises . 14
5.1 General . 14
5.2 Functional elements. 14
5.3 General structure and hierarchy . 14
5.4 Cabling subsystems . 15
5.5 Design objectives . 16
5.6 Accommodation of functional elements . 16
5.7 Interfaces . 17
5.8 Dimensioning and configuring . 18
6 PDAN cabling performance . 21
6.1 General . 21
6.2 Environmental performance . 21
6.3 Transmission performance . 21
7 Implementation options . 22
8 Cable requirements . 22
8.1 General . 22
8.2 Cable . 23
8.3 Microducts . 23
8.4 Microduct optical fibre . 23
9 Connecting hardware requirements . 23
9.1 General requirements . 23
9.2 Connecting hardware at the SI . 23
9.3 Connecting hardware at other places . 24
10 Cords . 24
11 Accommodation of the Subscriber Interface (SI) and the Customer Premises Equipment (CPE)24
11.1 Security for data integrity . 24
11.2 Placement of the housing . 25
Annex A (informative) Broadband infrastructure external to multi-subscriber premises . 26
---------------------- Page: 4 ----------------------
SIST EN 50700:2014
- 3 - EN 50700:2014
A.1 General . 26
A.2 Treatment of single-subscriber premises . 26
A.3 Treatment of multi-subscriber premises . 26
Bibliography . 28
Figures
Figure 1 Multi-subscriber PDAN cabling (LOC external to the premises) . 6
Figure 2 Example of multi-subscriber PDAN cabling (LOC internal to the premises) . 6
Figure 3 Schematic relationship between EN 50700 and other relevant TC 215 standards . 7
Figure 4 PDAN cabling distribution schematic with ADP (and future LOC) internal to multi-
subscriber building . 14
Figure 5 PDAN cabling distribution schematic with ADP (and future LOC) internal to premises . 15
Figure 6 PDAN cabling distribution schematic with future LOC external to premises . 15
Figure 7 Example of accommodation of functional elements. 17
Figure 8 Test and equipment interfaces . 18
Figure 9 SI connection to the customer network . 19
Figure 10 Examples of arrangements of SI, OAP and ENTI . 20
Figure 11 Examples of SI configuration of passive PDAN cabling . 21
Figure A.1 Broadband optical fibre cabling to subscriber premises . 26
Tables
Table 1 Contextual relationship between EN 50700 and other relevant TC 215 standards . 8
Table 2 PDAN cabling attenuation . 22
---------------------- Page: 5 ----------------------
SIST EN 50700:2014
EN 50700:2014 - 4 -
Foreword
This document (EN 50700:2014) has been prepared by CLC/TC 215 "Electrotechnical aspects of
telecommunication equipment".
The following dates are fixed:
• latest date by which this document has to be
(dop) 2014-11-25
implemented at national level by publication of
an identical national standard or by
endorsement
• latest date by which the national standards
(dow) 2016-11-25
conflicting with this document have to
be withdrawn
This document has been developed to enable the application of system-independent pre-cabling of multi-
subscriber premises to enable the delivery of broadband telecommunication services.
---------------------- Page: 6 ----------------------
SIST EN 50700:2014
- 5 - EN 50700:2014
Introduction
Fibre to the home (FTTH) is the subject of standardisation in the form of:
• Technical Reports such as CLC/TR 50510 which cover general concepts and system planning;
• component standards that support its implementation;
• installation standards such as the EN 50174 series.
FTTH is a general term applied to the provision of broadband optical networks to residential premises. Some
premises accommodate multiple subscribers and these may be residential or commercial enterprises such
as offices, data centres, industrial, retail or a mix of these subscriber types. These multi-subscriber premises
may consist of one or more buildings.
The cabling specified in this standard:
− constitutes the part of the broadband access network within multi-subscriber premises termed the
premises distribution access network (PDAN); the access network serving single subscriber premises is
not normatively addressed in this standard;
− is intended to be pre-installed, in readiness for subsequent connection of the multi-subscriber premises,
to an access provider’s infrastructure to an access demarcation point (ADP) - enabling broadband
content to be delivered by the service provider(s).
Within premises, the importance of the information technology cabling infrastructure is similar to that of other
fundamental building utilities such as heating, lighting and mains power. As with other utilities, interruptions
to service can have a serious impact. Poor quality of service due to lack of design foresight, use of
inappropriate components, incorrect installation, poor administration or inadequate support can disrupt
service delivery.
This standard:
− allows access providers to be aware of the minimum implementation delivered to them when they reach
such multi-subscriber premises;
− maximises the opportunity for network evolution by either the access provider or the service providers
using that access infrastructure.
This standard specifies the cabling between the access demarcation point (ADP) and the subscriber
interface (SI).The transmission performance of the premises cabling between the last operator connection
point (LOC) and the ADP is not addressed although the requirements for its accommodation are provided by
external reference to the EN 50174 series. The location of the LOC may be either outside the premises
boundary (see the schematic in Figure 1) or inside the premises, internal or external to a building (see the
schematic in Figure 2).
---------------------- Page: 7 ----------------------
SIST EN 50700:2014
EN 50700:2014 - 6 -
Transport access
Distribution access network
network
Premises boundary
Multi-subscriber
building
SI
SI
Premises
SI
entrance
ADP
One or
more
LOC
operators
Multi-building
sites
SI
subscriber
ADP
Premises
SI
entrance
Cabling within scope of this
standard
.
Figure 1 Multi-subscriber PDAN cabling (LOC external to the premises)
Transport access network Distribution
access network
Premises boundary
Multi-subscriber
building
SI
SI
One or
SI
more
LOC ADP
operators
sites
Multi-building
One or SI
subscriber
more
LOC ADP
operators
sites SI
Cabling within
scope of this
standard
Figure 2 Example of multi-subscriber PDAN cabling (LOC internal to the premises)
Where the subscribers’ premises are homes, the design of generic cabling beyond the SI is specified in
EN 50173-4. CLC/TR 50173-99-2 and CLC/TR 50173-99-3 provide additional information in relation to
cabling design within homes. For other types of subscribers, the design of generic cabling beyond the SI is
specified in other standards in the EN 50173 series.
This European Standard provides:
a) access providers with an application independent optical fibre cabling subsystem;
b) an open market for cabling components;
---------------------- Page: 8 ----------------------
SIST EN 50700:2014
- 7 - EN 50700:2014
c) building professionals (for example, architects) with guidance for the accommodation of cabling and
interfaces before specific requirements are known; i.e. in the initial planning either for construction or
refurbishment.
This European Standard specifies multi-vendor cabling, and is related to:
- standards for cabling components developed by Technical Committees of CENELEC and/or IEC;
- standards for the quality assurance and installation of information technology cabling (EN 50174 series)
and testing of installed cabling (EN 50346 and, by external reference, EN 61280-4-2 and
ISO/IEC 14763-3);
- applications developed by ETSI and Study Groups of ITU-T.
Figure 3 and Table 1 show the schematic and contextual relationships between the standards produced by
TC 215 for information technology cabling, namely:
1) the EN 50173 series where this standard interfaces to the subscriber;
2) installation (EN 50174 series);
3) testing of installed cabling (EN 50346).
EENN 50173 50173--1:1: I Innfforormmatatiion ton teecchnolhnologogyy --
GGenereneriicc c cablabliing sng syyssttememss -- GGenereneralal
rrequiequirrememententss
EENN 50173 50173--2:2: I Innfforormmatatiion ton teecchnolhnologogyy --
GGenereneriicc c cablabliing sng syyssttememss -- OOffffiicce pre preemmiisseses
EENN 50700: 50700: I Innfforormmatatiion ton teecchhnolnologogyy --
EENN 50173 50173--3:3: I Innfforormmatatiion ton teecchnolhnologogyy --
PPrrememiisseses di dissttrriibutbutiion acon accceessss net netwwororkk
GGenereneriicc c cablabliing sng syyssttememss -- IIndusndusttrriialal
((PPDDAANN)) c cablabliing tng to so supporupportt depldeplooyymmentent
prprememiisseess
ofof optoptiiccalal br broadband neoadband nettwwororkkss
EENN 50173 50173--4:4: I Innfforormmatatiion ton teecchnolhnologogyy --
GGenereneriicc c cablabliing sng syyssttememss -- HHomomeses
EENN 50173 50173--5:5: I Innfforormmatatiion ton teecchnolhnologogyy --
GGenereneriicc c cablabliing sng syyssttememss -- DDatata ca cententrreses
EENN 50173 50173--6:6: I Innfforormmatatiion ton teecchnolhnologogyy --
GGenereneriicc c cablabliing sng syyssttememss -- DDiissttrriibutbuted ed
buibuillddiing sng serervviicceses
EENN 50174 50174--1:1: I Innfforormmatatiion ton teecchnolhnologogyy --
CCablabliing ing insnsttalalllatatiion on -- IInsnsttalalllatatiion on
sspecpeciiffiiccatatiion and on and qualqualiittyy as asssururancancee
EENN 50174 50174--2:2: I Innfforormmatatiion ton teecchnolhnologogyy --
CCablabliing ing insnsttalalllatatiion on -- IInsnsttalalllatatiion on
plplannianning and prng and pracacttiicceses i insnsiide buide builldidingsngs
EENN 50174 50174--3:3: I Innfforormmatatiion ton teecchnolhnologogyy --
CCablabliing ing insnsttalalllatatiion on -- IInsnsttalalllatatiion on
plplannianning and prng and pracacttiicceses out outssiide buide buillddiingsngs
EENN 50346: 50346: I Innfforormmatatiion ton teecchhnolnologogyy --
CCablabliing ing insnsttalalllatatiion on --
TTesesttiing ofng of i insnsttalallled ced cablabliingng
Figure 3 Schematic relationship between EN 50700 and other relevant TC 215 standards
---------------------- Page: 9 ----------------------
SIST EN 50700:2014
EN 50700:2014 - 8 -
Table 1 Contextual relationship between EN 50700 and other relevant TC 215 standards
PDAN cabling design Specification phase Installation phase Operation phase
phase
EN 50700 EN 50174-1 EN 50174-1
5: Structure of PDAN cabling 4 Requirements for 4: Requirements for
within multi-subscriber specifying installations of specifying installations of
premises information technology information technology
cabling cabling
6: PDAN cabling
performance 5: Requirements for
installers of information
7: Implementation options
technology cabling
8: Cable requirements
9: Connecting hardware
requirements
Planning phase
EN 50174-2 EN 50174-2
4: Requirements for 5: Requirements for the
planning installations of installation of information
information technology technology cabling
cabling
6: Segregation of metallic
6: Segregation of metallic information technology
information technology cabling and power supply
cabling and power supply cabling
cabling
8: Office (commercial)
7: Electricity distribution premises
systems and lightning
9: Industrial premises
protection
10: Homes
8: Office (commercial)
premises
11: Data centres
9: Industrial premises
12: Multi-tenant pathways
and spaces
10: Homes
11: Data centres
12: Multi-tenant pathways
and spaces
and and
EN 50174-3 EN 50174-3
4. Requirements for 4. Requirements for
planning installations of planning installations of
information technology information technology
cabling cabling
5. Requirements for the 5. Requirements for the
installation of information installation of information
technology cabling technology cabling
6. Segregation 6. Segregation
7. Additional installation 7. Additional installation
practices for specific sites practices for specific sites
and services and services
and
EN 50346
4: General requirements
6: Test parameters for
optical fibre cabling
---------------------- Page: 10 ----------------------
SIST EN 50700:2014
- 9 - EN 50700:2014
1 Scope
This European Standard specifies the optical fibre optical fibre access network cabling within multi-
subscriber premises termed the premises distribution access network (PDAN). The premises may comprise
single or multiple buildings.
The cabling specified is intended to be pre-installed, in readiness for subsequent connection of the multi-
subscriber premises to an access providers infrastructure to support deployment of optical broadband
networks.
This European Standard does not specify either the access network cabling external to the premises or the
cabling within the subscriber space for onward distribution of services beyond the customer premises
equipment.
This European Standard specifies:
a) the structure and configuration of the optical fibre cabling;
b) cabling performance requirements;
c) implementation options.
Safety practices in relation to optical power hazard are specified in EN 60825-2. Optical powers higher than
the hazard levels specified in EN 60825-2 are not considered in this standard.
Safety (electrical safety, fire, etc.) and electromagnetic compatibility (EMC) requirements are outside the
scope of this European Standard and are covered by other standards and regulations. However, information
given in this European Standard may be of assistance in meeting these standards and regulations.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated references,
the latest edition of the referenced document (including any amendments) applies.
EN 50173-1:2011, Information technology Generic cabling systems Part 1: General requirements
EN 50174-1, Information technology Cabling installation Part 1: Installation specification and quality
assurance
Cabling installation Part 2: Installation planning and practices
EN 50174-2, Information technology
inside buildings
EN 50174-3, Information technology Cabling installation Part 3: Installation planning and practices
outside buildings
EN 50411-3-2:2011, Fibre organisers and closures to be used in optical fibre communication systems
Product specifications Part 3-2: Singlemode mechanical fibre splice
EN 50411-6-1, Fibre organisers and closures to be used in optical fibre communication systems Product
specifications Part 6-1: Unprotected microduct for category S and A
EN 60793-2-50:2013, Optical fibres Part 2-50: Product specifications Sectional specification for class B
single-mode fibres (IEC 60793-2-50:2012)
---------------------- Page: 11 ----------------------
SIST EN 50700:2014
EN 50700:2014 - 10 -
1)
EN 60794-5-10 , Optical fibre cables Part 5-10: Family specification for outdoor microduct optical fibre
1)
cables, microducts and protected microducts for installation by blowing (IEC 60794-5-10 )
1)
EN 60794-5-20 , Optical fibre cables Part 5-20: Family specification for outdoor microduct fibre units,
1)
microducts and protected microducts for installation by blowing (IEC 60794-5-20 )
2)
EN 61280-4-2 , Fibre optic communication subsystem basic test procedures Part 4-2: Fibre optic cable
plant Single-mode fibre optic cable plant attenuation (IEC 61280-4-2)
EN 61754-20:2012, Fibre optic interconnecting devices and passive components Fibre optic connector
interfaces Part 20: Type LC connector family (IEC 61754-20:2012)
EN 61755-1:2006, Fibre optic connector optical interfaces Part 1: Optical interfaces for single mode non-
dispersion shifted fibres General and guidance (IEC 61755-1:2005)
EN 61755-2-2:2006, Fibre optic connector optical interfaces Part 2-2: Optical interface standard single
mode angled physically contacting fibres (IEC 61755-2-2:2006)
3 Terms, definitions and abbreviations
3.1 Terms and definitions
For the purposes of this document the following terms and definitions apply.
3.1.1
access demarcation point
location from which premises distribution access network cabling is routed to subscribers
3.1.2
access network
functional elements (equipment and infrastructure) that enable communication between the core network
and a customer network
[SOURCE: EN 50174-3:2013, 3.1.1]
3.1.3
access provider
operator or another entity providing the means to enable external telecommunications service provision to a
subscriber
3.1.4
building entrance facility
facility that provides all necessary mechanical and electrical services for the entry of telecommunication
cables into a building and which may allow for transition from external to internal cable
[SOURCE: EN 50173-1:2011, 3.1.17]
3.1.5
cabling
system of telecommunications cables, cords and connecting hardware that supports the operation of
information technology equipment
[SOURCE: EN 50173-1:2011, 3.1.22]
———————
1) To be published.
2) Edition 2 in development at this time.
---------------------- Page: 12 ----------------------
SIST EN 50700:2014
- 11 - EN 50700:2014
3.1.6
core network
functional elements (equipment and infrastructure) that enable communication between operator sites and/or
network data centres
[SOURCE: EN 50174-3:2013, 3.1.6]
3.1.7
customer network
functional elements (equipment and infrastructure) that enable communication between the subscriber
interface and one or more attached terminal equipment
[SOURCE: ETSI TS 105 174-1:2009, 3.1, modified]
3.1.8
customer premises equipment
CPE
equipment, not owned by subscribers, that is located on the customer's premises
3.1.9
distribution access network
sub-part of the access network comprising the functional elements that enable communication between the
last operator connection point and the subscriber interface
[SOURCE: ETSI TS 105 174-1:2009, modified]
3.1.10
equipment interface
point at which application-specific equipment can be connected to the premises distribution access network
cabling
3.1.11
external network test interface
point in or near the customer premises accessible to the network operator for testing purposes
[SOURCE: ETSI TS 105 174-1:2009, 3.1, modified]
3.1.12
last operator connection point
interface to the transport access networks of one or more operators from which cabling is routed to the
access demarcation point (ADP) of the premises distribution access network cabling
3.1.13
multi-building subscriber
subscriber accommodated in more than one building within the premises
3.1.14
multi-subscriber premises
premises which are designed to accommodate more than one subscriber
3.1.15
operator access point
optional functional element of the premises distribution access network which allows a service provider to
install an external network test interface between the subscriber interface and the access demarcation point
3.1.16
operator site
premises accommodating network telecommunications equipment providing direct connection to the core
and access networks and which may also accommodate information technology equipment
[SOURCE: ETSI TR 105 174-2-1:2009, 3.1]
---------------------- Page: 13 ----------------------
SIST EN 50700:2014
EN 50700:2014 - 12 -
3.1.17
premises distribution access network
sub-part of the access network within multi-subscriber premises comprising the functional elements that
enable communication between the access demarcation point and the subscriber interface
3.1.18
primary distributor
distributor in which the cable(s) from the access demarcation point is distributed onward to the secondary
distributor(s), if present, or the subscriber interface
3.1.19
secondary distributor
distributor in which the cable(s) from the primary distributor, or another secondary distributor, is (are)
distributed onward to other secondary distributor(s), if present, or the subscriber interface
3.1.20
service provider
operator of any service that furnishes telecommunications content (transmissions) delivered over access
provider facilities
Note 1 to entry: The access provider and the service provider can be a single entity.
3.1.21
single-subscriber premises
premises which are designed to accommodate a single subscriber
3.1.22
subscriber
identifiable entity within the premises that may require a future direct connection to the access network
3.1.23
subscriber entrance facility
facility that provides all necessary mechanical and electrical services for the entry of cables into a
subscribers space
3.1.24
subscriber interface
point where the customer premises equipment is connected to the premises distribution access network
cabling
3.1.25
subscriber space
space within the premises allocated to a subscriber
3.1.26
test interface
point at which test equipment can be connected to the premises distribution access network cabling
3.1.27
transport access network
sub-part of the access network comprising the
...