EN IEC 60695-11-2:2026
(Main)Fire hazard testing - Part 11-2: Test flames - 1 kW pre-mixed flame - Apparatus, confirmatory test arrangement and guidance
- Status
- Not Published
- Publication Date
- 17-Dec-2026
- Technical Committee
- CLC/SR 89 - Fire hazard testing
- Current Stage
- 5060 - Voting results sent to TC, SR - Formal Approval
- Start Date
- 18-Sep-2026
- Due Date
- 18-Sep-2026
- Completion Date
- 18-Sep-2026
EN IEC 60695-11-2:2026 is the IEC standard for fire hazard testing that specifies a nominal 1 kW propane/air pre-mixed flame. It gives the apparatus, the confirmatory test arrangement, and the guidance needed to produce and check that flame before it is used in other fire tests. Engineers, test laboratories, and standards writers use EN IEC 60695-11-2:2026 when they need a repeatable test flame with defined output and geometry.
What does EN IEC 60695-11-2:2026 specify?
EN IEC 60695-11-2:2026 specifies how to produce and confirm a nominal 1 kW propane/air pre-mixed flame for fire hazard testing. Clause 1 also makes clear that the requirements apply when another publication specifically refers to them or includes them.
The document is organized as follows:
- Clause 1 - Scope
- Clause 2 - Normative references
- Clause 3 - Terms and definitions
- Clause 4 - Burner/supply arrangement
- Clause 5 - Production of the test flame
- Clause 6 - Confirmation of the test flame
- Clause 7 - Recommended arrangements for use of the test flame
- Annex A - Burner details, arrangements and confirmatory test
- Annex B - Chemical composition of electrolytic tough pitch copper Cu-ETP USN C11000
| Annex | What it covers |
|---|---|
| Annex A | Burner construction, gas supply arrangement, copper block, and confirmatory test arrangement |
| Annex B | Chemical composition requirement for the copper used for the block |
What are the key requirements of EN IEC 60695-11-2:2026?
EN IEC 60695-11-2:2026 focuses on three practical tasks: build the burner correctly, set the flame to the stated gas and air conditions, and confirm the flame output with the copper block test. Those steps matter because this standard is used to create comparable fire test conditions across different laboratories and test programs.
Burner, fuel, and test chamber
Clause 4.1 requires the standardized 1 kW test flame to be produced with the hardware shown in Annex A, with propane of at least 95 % purity and air that is essentially free of oil and water. The flame must be symmetrical, stable, and must pass the confirmatory test result of 46 s ± 6 s.
Clause 4.2.2 requires flow controllers that can measure and control both propane and air at the stated rates with suitable accuracy. In practice, this means the gas train must be set up with proper flow measurement, not by visual adjustment alone.
Clause 4.2.6 requires a laboratory fumehood or chamber of at least 1.0 m³, with a draught-free environment and the ability to observe the test. The chamber should be dark enough for visual observation, and any extraction device must be off during the test and used immediately afterward.
Producing the flame
Clause 5.1 says Method A is the default unless another relevant standard specifies otherwise. Clause 5.2 and Clause 5.3 give two ways to set the propane and air flows, with Method B offering wider tolerances as an alternative.
In practice, the user needs to set leak-free gas connections, ignite the burner, and adjust the flows until the flame appears stable and symmetrical. The document also gives the approximate flame dimensions in Figure 1, which helps operators check that the flame shape matches the intended condition.
Confirming the flame
Clause 6.1 uses a copper block test to confirm that the flame delivers the intended effective power output. The measured time for the block to heat from 100 °C ± 5 °C to 700 °C ± 3 °C must be 46 s ± 6 s when the arrangement in Figure A.8 is used.
Clause 6.2 sets the occasions for confirmation: when the gas supply changes, when test equipment is replaced, when the data are questioned, before use if the flame has not been used for more than one month, or at least monthly if it is used more often. This gives users a routine for keeping the flame under control.
Clause 6.3 requires the user to establish equilibrium, then make three successive determinations once the first acceptable result has been obtained. If the copper block is new, a preliminary run is made to condition the surface and that result is discarded.
Using the flame in tests
Clause 7 gives recommended burner positions for use with products and material strips. For equipment testing, the burner is normally kept about 100 mm from the specimen surface, and for strips of material the blue cone is kept as close as possible without touching the specimen.
That practical guidance matters because burner position affects reproducibility, specimen heating, and the way burning debris interacts with the burner.
What terms does EN IEC 60695-11-2:2026 define?
EN IEC 60695-11-2:2026 uses the definitions from ISO 13943:2017 and adds its own key terms for this flame method.
- Combustion - an exothermic reaction with an oxidizing agent; in this context it is the basic fire process the test flame is meant to initiate or support.
- Draught-free environment - a space where local air speed does not significantly affect test results; this matters because drafts change flame behavior and heating.
- Flame - rapid, self-sustaining propagation of combustion in a gaseous medium, usually with visible light.
- Pre-mixed flame - a flame in which the fuel and oxidizing agent are mixed before combustion; this is the flame type specified here.
- Standardized 1 kW test flame - a test flame that meets the requirements of Clauses 4 to 6 of this standard.
- Propane/air pre-mixed flame - the specified flame system used by the document for fire hazard testing.
Who uses EN IEC 60695-11-2:2026?
EN IEC 60695-11-2:2026 is used by technical committees that prepare fire safety publications for electrotechnical products. The introduction says it supports the design of components, circuits, products, and materials when the aim is to reduce fire risk during normal use, foreseeable abnormal use, malfunction, or failure.
In practice, the standard is used by:
- test laboratories setting up or checking a 1 kW test flame
- product safety and fire risk engineers
- standards writers who need a referenced flame source in product standards
- quality and compliance teams that verify test equipment before formal testing
It is also relevant to anyone performing fire hazard testing where a repeatable external flame source is required.
What changed in EN IEC 60695-11-2:2026 from the previous edition?
EN IEC 60695-11-2:2026 is the fourth edition and replaces the third edition published in 2017. The stated technical revision is the correction of errors in the notes of subclauses 5.2 and 5.3.
Which standards are used with EN IEC 60695-11-2:2026?
EN IEC 60695-11-2:2026 uses IEC 60584-1 and ISO 13943:2017 as normative references.
- IEC 60584-1 - provides the EMF specifications and tolerances for the thermocouple used to measure the copper block temperature.
- ISO 13943:2017 - provides the fire safety vocabulary used for the defined terms in Clause 3.
Related standards named with this document include:
- IEC TS 60695-11-40 - guidance for confirmatory tests for test flames
- IEC 60695-1-10 - general guidance for assessing fire hazard of electrotechnical products
- IEC 60695-1-11 - fire hazard assessment guidance
- IEC GUIDE 104 and ISO/IEC Guide 51 - the basic safety publication framework used for preparing safety standards
What does the EN IEC 60695-11-2:2026 document contain?
EN IEC 60695-11-2:2026 contains the technical description of the burner, the gas supply arrangement, the copper block, and the confirmatory test arrangement in Annex A. Figures A.1 to A.8 show the assembly, burner details, supply arrangement, copper block, and confirmatory setup, while Figure 1 shows the flame dimensions.
The document also contains the step-by-step methods for producing the flame and verifying it against the copper block heating time. Annex B gives the copper composition requirement for the block material, which is part of keeping the confirmatory test consistent across users.
Relations
- Effective Date
- 15-Apr-2025
Get Certified
Connect with accredited certification bodies for this standard
CIS Institut d.o.o.
Personal Protective Equipment (PPE) certification body. Notified Body NB-2890 for EU Regulation 2016/425 PPE.

Kiwa BDA Testing
Building and construction product certification.
Kmetijski inštitut Slovenije
Agricultural Institute of Slovenia. Soil testing, plant health, agricultural product analysis.
Sponsored listings
Frequently Asked Questions
EN IEC 60695-11-2:2026 is a draft published by CLC. Its full title is "Fire hazard testing - Part 11-2: Test flames - 1 kW pre-mixed flame - Apparatus, confirmatory test arrangement and guidance". This standard covers: Fire hazard testing - Part 11-2: Test flames - 1 kW pre-mixed flame - Apparatus, confirmatory test arrangement and guidance
Fire hazard testing - Part 11-2: Test flames - 1 kW pre-mixed flame - Apparatus, confirmatory test arrangement and guidance
EN IEC 60695-11-2:2026 is classified under the following ICS (International Classification for Standards) categories: 13.220.40 - Ignitability and burning behaviour of materials and products. The ICS classification helps identify the subject area and facilitates finding related standards.
EN IEC 60695-11-2:2026 has the following relationships with other standards: It is inter standard links to EN 60695-11-2:2017. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN IEC 60695-11-2:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
oSIST prEN IEC 60695-11-2:2026
01-marec-2026
Preskušanje požarne ogroženosti - 11-2. del: Preskusni plameni - Predmešani
plamen z močjo 1 kW - Aparat, način potrditvenega preskušanja in navodilo
Fire hazard testing - Part 11-2: Test flames - 1 kW pre-mixed flame - Apparatus,
confirmatory test arrangement and guidance
Essais relatifs aux risques du feu - Partie 11-2: Flammes d'essai - Flamme à prémélange
de 1 kw nominal - Appareillage, configuration pour l'essai de vérification et
préconisations
Ta slovenski standard je istoveten z: prEN IEC 60695-11-2:2026
ICS:
13.220.40 Sposobnost vžiga in Ignitability and burning
obnašanje materialov in behaviour of materials and
proizvodov pri gorenju products
oSIST prEN IEC 60695-11-2:2026 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
oSIST prEN IEC 60695-11-2:2026
oSIST prEN IEC 60695-11-2:2026
89/1642/CDV
COMMITTEE DRAFT FOR VOTE (CDV)
PROJECT NUMBER:
IEC 60695-11-2 ED4
DATE OF CIRCULATION: CLOSING DATE FOR VOTING:
2026-01-23 2026-04-17
SUPERSEDES DOCUMENTS:
89/1623/CD, 89/1633/CC
IEC TC 89 : FIRE HAZARD TESTING
SECRETARIAT: SECRETARY:
Germany Mr Bernd Komanschek
OF INTEREST TO THE FOLLOWING COMMITTEES: HORIZONTAL FUNCTION(S):
TC 20,SC 23A,TC 51,TC 61,TC 108,ACOS TC 89 Horizontal Basic Safety
ASPECTS CONCERNED:
Safety
SUBMITTED FOR CENELEC PARALLEL VOTING NOT SUBMITTED FOR CENELEC PARALLEL VOTING
Attention IEC-CENELEC parallel voting
The attention of IEC National Committees, members of
CENELEC, is drawn to the fact that this Committee Draft
for Vote (CDV) is submitted for parallel voting.
The CENELEC members are invited to vote through the
CENELEC online voting system.
This document is still under study and subject to change. It should not be used for reference purposes.
Recipients of this document are invited to submit, with their comments, notification of any relevant patent rights of
which they are aware and to provide supporting documentation.
Recipients of this document are invited to submit, with their comments, notification of any relevant “In Some
Countries” clauses to be included should this proposal proceed. Recipients are reminded that the CDV stage is
the final stage for submitting ISC clauses. (SEE AC/22/2007 OR NEW GUIDANCE DOC).
TITLE:
Fire hazard testing - Part 11-2: Test flames - 1 kW pre-mixed flame - Apparatus, confirmatory
test arrangement and guidance
PROPOSED STABILITY DATE: 2030
NOTE FROM TC/SC OFFICERS:
OSD project ready to be circulated as CDV.
download this electronic file, to make a copy and to print out the content for the sole purpose of preparing National
Committee positions. You may not copy or "mirror" the file or printed version of the document, o r any part of it, for
any other purpose without permission in writing from IEC.
oSIST prEN IEC 60695-11-2:2026
IEC CDV 60695-11-2 © IEC 2026
Link to Committee Draft for Vote (CDV) online document:
Click here
How to access
This link leads you to the Online Standards Development (OSD) platform for National Mirror
Committee’s (NMC) comments. The project draft may be found further down this document.
Resource materials
We recommend NCs to review the available materials to better understand the member
commenting on the OSD platform. This includes the:
• OSD NC roles overview
• How to add and submit comments to the IEC
Contact
Should you require any assistance, please contact the IEC IT Helpdesk.
oSIST prEN IEC 60695-11-2:2026
IEC CDV 60695-11-2 © IEC 2026
CONTENTS
CONTENTS . 3
FOREWORD . 4
INTRODUCTION . 7
1 Scope . 8
2 Normative references . 8
3 Terms and definitions . 8
4 Burner/supply arrangement . 9
4.1 Requirements . 9
4.2 Apparatus and fuel . 9
4.2.1 Burner . 9
4.2.2 Flow control . 9
4.2.3 Copper block . 9
4.2.4 Thermocouple . 10
4.2.5 Temperature/time indicating/recording devices . 10
4.2.6 Laboratory fumehood/chamber . 10
5 Production of the test flame . 10
5.1 Selection of the method . 10
5.2 Method A . 10
5.3 Method B (alternative). 11
6 Confirmation of the test flame . 11
6.1 Principle . 11
6.2 Frequency of confirmatory tests . 11
6.3 Procedure . 11
7 Recommended arrangements for use of the test flame . 12
Annex A (normative) Burner details, arrangements and confirmatory test. 14
A.1 Burner construction . 14
A.2 Gas supply arrangement . 17
A.3 The copper block . 17
A.4 Confirmatory test . 17
Annex B (normative) Chemical composition of electrolytic tough pitch copper Cu -ETP
USN C11000 . 19
Bibliography . 20
Figure 1 – Flame dimensions . 12
Figure A.1 – General assembly . 14
Figure A.2 – Burner details (1) . 15
Figure A.3 – Burner details (2) . 15
Figure A.4 – Burner details (3) . 16
Figure A.5 – Burner details (4) . 16
Figure A.6 – Example of supply arrangement for burner . 17
Figure A.7 – Copper block . 17
Figure A.8 – Confirmatory test arrangement . 18
oSIST prEN IEC 60695-11-2:2026
IEC CDV 60695-11-2 © IEC 2026
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
Fire hazard testing -
Part 11-2: Test flames - 1 kW pre-mixed flame - Apparatus, confirmatory
test arrangement and guidance
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for
standardization comprising all national electrotechnical committees (IEC National Committees).
The object of IEC is to promote international co-operation on all questions concerning
standardization in the electrical and electronic fields. To this end and in addition to other
activities, IEC publishes International Standards, Technical Specifications, Technical Reports,
Publicly Available Specifications (PAS) and Guides (hereafter referred to as "IEC
Publication(s)"). Their preparation is entrusted to technical committees; any IEC National
Committee interested in the subject dealt with may participate in this preparatory work.
International, governmental and non-governmental organizations liaising with the IEC also
participate in this preparation. IEC collaborates closely with the International Organization for
Standardization (ISO) in accordance with conditions determined by agreement between the two
organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as
possible, an international consensus of opinion on the relevant subjects since each technical
committee has representation from all interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted
by IEC National Committees in that sense. While all reasonable efforts are made to ensure that
the technical content of IEC Publications is accurate, IEC cannot be held responsible for the
way in which they are used or for any misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC
Publications transparently to the maximum extent possible in their national and regional
publications. Any divergence between any IEC Publication and the corres ponding national or
regional publication shall be clearly indicated in the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies
provide conformity assessment services and, in some areas, access to IEC marks of conformity.
IEC is not responsible for any services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including
individual experts and members of its technical committees and IEC National Committees for
any personal injury, property damage or other damage of any nature whatsoever, whether direct
or indirect, or for costs (including legal fees) and expenses arising out of the publication, use
of, or reliance upon, this IEC Publication or any other IEC Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced
publications is indispensable for the correct application of this publication.
9) IEC draws attention to the possibility that the implementation of this document may involve
the use of (a) patent(s). IEC takes no position concerning the evidence, validity or applicability
of any claimed patent rights in respect thereof. As of the date of publication of this document,
IEC [had/had not] received notice of (a) patent(s), which may be required to implement this
oSIST prEN IEC 60695-11-2:2026
IEC CDV 60695-11-2 © IEC 2026
document. However, implementers are cautioned that this may not represent the latest
information, which may be obtained from the patent database available at https://patents.iec.ch.
IEC shall not be held responsible for identifying any or all such patent r ights.
IEC 60695-11-2 has been prepared by IEC technical committee 89: Fire hazard testing.
This fourth edition cancels and replaces the third edition published in 2017. This edition
constitutes a technical revision.
It has the status of a basic safety publication in accordance with IEC GUIDE 104 [1] and ISO/IEC
Guide 51 [2].
This edition includes the following significant technical changes with respect to the previous
edition:
a) correction of errors in notes of subclauses 5.2 and 5.3
The text of this International Standard is based on the following documents:
CDV Report on voting
Full information on the voting for its approval can be found in the report on voting indicated in
the above table.
The language used for the development of this International Standard is English [change
language if necessary].
This document was drafted in accordance with ISO/IEC Directives, Part 2, and developed in
accordance with ISO/IEC Directives, Part 1 and ISO/IEC Directives, IEC Supplement, available
at www.iec.ch/members_experts/refdocs. The main document types developed by IEC are
described in greater detail at www.iec.ch/publications.
A list of all the parts in the IEC 60695 series, under the general title Fire hazard testing can be
found on the IEC web site.
Part 11 consists of the following parts:
Part 11-2, Test flames – 1 kW nominal pre-mixed flame – Apparatus, confirmatory test
arrangement and guidance
Part 11-3, Test flames – 500 W flames – Apparatus and confirmational test methods
Part 11-4, Test flames – 50 W flame – Apparatus and confirmational test method
Part 11-5, Test flames – Needle-flame test method – Apparatus, confirmatory test arrangement
and guidance
Part 11-10, Test flames – 50 W horizontal and vertical flame test methods
Part 11-11, Test flames – Determination of the characteristic heat flux for ignition from a non-
contacting flame source
Part 11-20, Test flames – 500 W flame test methods
Part 11-21: Test flames - 500 W vertical flame test method for tubular polymeric materials
oSIST prEN IEC 60695-11-2:2026
IEC CDV 60695-11-2 © IEC 2026
Part 11-30, Test flames – History and development from 1979 to 1999
IEC TS 60695-11-40 [3], Test flames – Confirmatory tests – Guidance
The committee has decided that the contents of this document will remain unchanged until the
stability date indicated on the IEC website under webstore.iec.ch in the data related to the
specific document. At this date, the document will be
– reconfirmed,
– withdrawn, or
– revised.
oSIST prEN IEC 60695-11-2:2026
IEC CDV 60695-11-2 © IEC 2026
INTRODUCTION
In the design of any electrotechnical product, the risk of fire and the potential hazards
associated with fire need to be considered. In this respect the objective of component, circuit,
and product design, as well as the choice of materials, is to reduce to acceptable levels the
potential risks of fire during normal operating conditions, reasonable foreseeable abnormal use,
malfunction, and/or failure. The IEC has developed IEC 60695-1-10 [4] , together with its
companion, IEC 60695-1-11 [5], to provide guidance on how this is to be accomplished.
The primary aims of IEC 60695-1-10 [4] and IEC 60695-1-11 [5] are to provide guidance on
how:
a) to prevent ignition caused by an electrically energized component part, and
b) to confine any resulting fire within the bounds of the enclosure of the electrotechnical
product in the event of ignition.
Secondary aims of these documents include the minimization of any flame spread beyond the
product’s enclosure and the minimization of harmful effects of fire effluents such as heat,
smoke, toxicity and/or corrosivity.
Fires involving electrotechnical products can also be initiated from external non -electrical
sources. Considerations of this nature should be dealt with in the overall fire risk assessment.
IEC 60695-11-2 provides a description of the apparatus required to produce a 1 kW test flame,
and provides a description of the principle of a confirmation procedure to check that the effective
power output of the flame is as intended. Guidance on confirmatory tests for test flames is given
in IEC TS 60695-11-40 [3].
This part of IEC 60695 may involve hazardous materials, operations, and equipment. It does
not purport to address all of the safety problems associat
...