IEC 61892-4:2007
(Main)Mobile and fixed offshore units - Electrical installations - Part 4: Cables
Mobile and fixed offshore units - Electrical installations - Part 4: Cables
This part of IEC 61892 specifies requirements for the choice and installation of electrical cables intended for fixed electrical systems in mobile and fixed offshore units, including pumping or "pigging" stations, compressor stations and exposed location single buoy moorings, used in the offshore petroleum industry for drilling, production, processing and for storage purposes.
General Information
Relations
Standards Content (Sample)
INTERNATIONAL IEC
STANDARD 61892-4
First edition
2007-06
Mobile and fixed offshore units –
Electrical installations –
Part 4:
Cables
Reference number
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form
or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from
either IEC or IEC's member National Committee in the country of the requester.
If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication,
please contact the address below or your local IEC member National Committee for further information.
IEC Central Office
3, rue de Varembé
CH-1211 Geneva 20
Switzerland
Email: inmail@iec.ch
Web: www.iec.ch
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.
About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.
ƒ Catalogue of IEC publications: www.iec.ch/searchpub
The IEC on-line Catalogue enables you to search by a variety of criteria (reference number, text, technical committee,…).
It also gives information on projects, withdrawn and replaced publications.
ƒ IEC Just Published: www.iec.ch/online_news/justpub
Stay up to date on all new IEC publications. Just Published details twice a month all new publications released. Available
on-line and also by email.
ƒ Customer Service Centre: www.iec.ch/webstore/custserv
If you wish to give us your feedback on this publication or need further assistance, please visit the Customer Service
Centre FAQ or contact us:
Email: csc@iec.ch
Tel.: +41 22 919 02 11
Fax: +41 22 919 03 00
INTERNATIONAL IEC
STANDARD 61892-4
First edition
2007-06
Mobile and fixed offshore units –
Electrical installations –
Part 4:
Cables
PRICE CODE
Commission Electrotechnique Internationale X
International Electrotechnical Commission
МеждународнаяЭлектротехническаяКомиссия
For price, see current catalogue
– 2 – 61892-4 © IEC:2007(E)
CONTENTS
FOREWORD.4
INTRODUCTION.6
1 Scope.7
2 Normative references .7
3 Terms and definitions .8
4 Types, installation and operating conditions of cables .10
4.1 Types of cables .10
4.2 Voltage rating.10
4.2.1 Power frequency cables .10
4.2.2 Control and instrumentation cables.11
4.3 Cross-sectional areas of conductors and current-carrying capacities .11
4.3.1 Cross-sectional areas of conductors .11
4.3.2 Current-carrying capacities.13
4.3.3 Current-carrying capacities for continuous service.13
4.3.4 Correction factors for different ambient air temperatures .17
4.3.5 Correction factors for short time duty.18
4.3.6 Correction factors for cable grouping .21
4.4 Voltage drop.22
4.5 Estimation of lighting loads.22
4.6 Parallel connection of cables.22
4.7 Separation of circuits.22
4.8 Short circuit capacity (withstand capability). .22
4.9 Conductor .22
4.10 Insulation material.23
4.11 Screen, core screen or shield .23
4.12 Sheathing material .23
4.13 Metallic braid armour.23
4.14 Fire performance.23
4.15 Bending radius .24
Annex A (informative) Tabulated current-carrying capacities – Defined installations .26
Annex B (Informative) Fire stops.40
Annex C (Informative) Jet fire test for hydrocarbon (HCF) fire resistant cables .41
Annex D (Informative) Drilling fluid test procedure and requirements .42
Bibliography.
Table 1 – Choice of cables for a.c. systems .11
∗
Table 2 – Sizes of earth continuity conductors and equipment earthing connections.13
Table 3 – Coefficient related to maximum permissible temperature of the conductor.14
Table 4 – Current-carrying capacities in continuous service at maximum rated
conductor temperature of 70 °C (ambient air temperature 45 °C) .15
61892-4 © IEC:2007(E) – 3 –
Table 5 – Current-carrying capacities in continuous service at maximum rated
conductor temperature of 90 °C (ambient air temperature 45 °C) .16
Table 6 – Current-carrying capacities in continuous service at maximum rated
conductor temperature of 95 °C (ambient air temperature 45 °C) .17
Table 7 – Correction factor for various ambient air temperatures (reference ambient
temperature of 45 °C) .18
Table 8 – Correction factor for various ambient air temperatures (reference ambient
temperature of 30 °C) .18
Table 9 – Bending radii for cables rated up to 1,8/3 kV .25
Table 10 – Bending radii for cables rated at 3,6/6,0(7,2) kV and above.25
Table A.1 – Current-carrying capacities in amperes – Copper conductor temperature
60 °C and reference ambient air temperature 45 °C .29
Table A.2 – Current-carrying capacities in amperes – Copper conductor temperature
70 °C and reference ambient air temperature 45 °C .30
Table A.3 – Current-carrying capacities in amperes – Copper conductor temperature
85 °C and reference ambient air temperature 45 °C .31
Table A.4 – Current-carrying capacities in amperes – Copper conductor temperature
60 °C and reference ambient air temperature 30 °C .32
Table A.5 – Current-carrying capacities in amperes – Copper conductors temperature
70 °C and reference ambient temperature 30 °C .33
Table A.6 – Current-carrying capacities in amperes – Copper conductors temperature
85 °C and reference ambient temperature 30 °C .34
Table A.7 – Current-carrying capacities in amperes – Copper conductors temperature
90 °C and reference ambient temperature 45 °C .35
Table A.8 – Current-carrying capacities in amperes – Copper conductors temperature
95 °C and reference ambient temperature 45 °C .36
Table A.9 – Correction factors for groups of more than one circuit or of more than one
multi-core cable to be used with current-carrying capacities of Tables A.1 to A.8.37
Table A.10 – Correction factors for group of more than one multi-core cable to be
applied to reference ratings for multi-core cables in free air – Method of installation E
in Tables A.1 to A.8 .38
Table A.11 – Correction factors for groups of more than one circuit of single-core
cables to be applied to reference rating for one circuit of single-core cables in free air
– Method of installation F in Tables A.1 to A.8 .39
Figure 1 – Time constant of cables .19
Figure 2 – Correction factors for half-hour and one-hour service.20
Figure 3 – Correction factor for intermittent service.21
Figure C.1 – International recognized HC fire curve .41
– 4 – 61892-4 © IEC:2007(E)
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
MOBILE AND FIXED OFFSHORE UNITS –
ELECTRICAL INSTALLATIONS –
Part 4: Cables
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with an IEC Publication.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61892-4 has been prepared by IEC technical committee 18:
Electrical installations of ships and of mobile and fixed offshore units, in cooperation with
SC 18A: Cables and cable installations.
The text of this standard is based on the following documents:
FDIS Report on voting
18/1052/FDIS 18/1058/RVD
Full information on the voting for the app
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.