IEC 61753-111-7:2009
(Main)Fibre optic interconnecting devices and passive components performance standard - Part 111-7: Sealed closures for category A - Aerial
- Abstract
IEC 61753-111-7:2009 contains the minimum test and measurement requirements and severities which a sealed fibre optic closure must satisfy in order to be categorised as meeting the IEC standard for category A - aerial, as defined in Annex A of IEC 61753-1. Free breathing closures are not covered in this standard.
- Status
- Replaced
- Publication Date
- 09-Nov-2009
- Technical Committee
- SC 86B - Fibre optic interconnecting devices and passive components
- Current Stage
- DELPUB - Deleted publication - 99 Deleted
- Start Date
- 03-Sep-2021
- Due Date
- 29-May-2020
- Completion Date
- 29-May-2020
Relations
- Effective Date
- 05-Sep-2023
Get Certified
Connect with accredited certification bodies for this standard

ANCE
Mexican certification and testing association.

Intertek Slovenia
Intertek testing, inspection, and certification services in Slovenia.

LNE (Laboratoire National de Métrologie et d'Essais)
French national laboratory for metrology and testing.
Sponsored listings
Frequently Asked Questions
IEC 61753-111-7:2009 is a standard published by the International Electrotechnical Commission (IEC). Its full title is "Fibre optic interconnecting devices and passive components performance standard - Part 111-7: Sealed closures for category A - Aerial". This standard covers: IEC 61753-111-7:2009 contains the minimum test and measurement requirements and severities which a sealed fibre optic closure must satisfy in order to be categorised as meeting the IEC standard for category A - aerial, as defined in Annex A of IEC 61753-1. Free breathing closures are not covered in this standard.
IEC 61753-111-7:2009 contains the minimum test and measurement requirements and severities which a sealed fibre optic closure must satisfy in order to be categorised as meeting the IEC standard for category A - aerial, as defined in Annex A of IEC 61753-1. Free breathing closures are not covered in this standard.
IEC 61753-111-7:2009 is classified under the following ICS (International Classification for Standards) categories: 33.180.20 - Fibre optic interconnecting devices. The ICS classification helps identify the subject area and facilitates finding related standards.
IEC 61753-111-7:2009 has the following relationships with other standards: It is inter standard links to IEC 61753-111-07:2021. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
IEC 61753-111-7:2009 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
IEC 61753-111-7 ®
Edition 1.0 2009-11
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Fibre optic interconnecting devices and passive components performance
standard –
Part 111-7: Sealed closures for category A – Aerial
Dispositifs d'interconnexion et composants passifs à fibres optiques norme de
qualité de fonctionnement –
Partie 111-7: Boîtiers scellés pour catégorie A – Aériens
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by
any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either IEC or
IEC's member National Committee in the country of the requester.
If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication,
please contact the address below or your local IEC member National Committee for further information.
Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite
ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie
et les microfilms, sans l'accord écrit de la CEI ou du Comité national de la CEI du pays du demandeur.
Si vous avez des questions sur le copyright de la CEI ou si vous désirez obtenir des droits supplémentaires sur cette
publication, utilisez les coordonnées ci-après ou contactez le Comité national de la CEI de votre pays de résidence.
IEC Central Office
3, rue de Varembé
CH-1211 Geneva 20
Switzerland
Email: inmail@iec.ch
Web: www.iec.ch
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.
About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.
ƒ Catalogue of IEC publications: www.iec.ch/searchpub
The IEC on-line Catalogue enables you to search by a variety of criteria (reference number, text, technical committee,…).
It also gives information on projects, withdrawn and replaced publications.
ƒ IEC Just Published: www.iec.ch/online_news/justpub
Stay up to date on all new IEC publications. Just Published details twice a month all new publications released. Available
on-line and also by email.
ƒ Electropedia: www.electropedia.org
The world's leading online dictionary of electronic and electrical terms containing more than 20 000 terms and definitions
in English and French, with equivalent terms in additional languages. Also known as the International Electrotechnical
Vocabulary online.
ƒ Customer Service Centre: www.iec.ch/webstore/custserv
If you wish to give us your feedback on this publication or need further assistance, please visit the Customer Service
Centre FAQ or contact us:
Email: csc@iec.ch
Tel.: +41 22 919 02 11
Fax: +41 22 919 03 00
A propos de la CEI
La Commission Electrotechnique Internationale (CEI) est la première organisation mondiale qui élabore et publie des
normes internationales pour tout ce qui a trait à l'électricité, à l'électronique et aux technologies apparentées.
A propos des publications CEI
Le contenu technique des publications de la CEI est constamment revu. Veuillez vous assurer que vous possédez
l’édition la plus récente, un corrigendum ou amendement peut avoir été publié.
ƒ Catalogue des publications de la CEI: www.iec.ch/searchpub/cur_fut-f.htm
Le Catalogue en-ligne de la CEI vous permet d’effectuer des recherches en utilisant différents critères (numéro de référence,
texte, comité d’études,…). Il donne aussi des informations sur les projets et les publications retirées ou remplacées.
ƒ Just Published CEI: www.iec.ch/online_news/justpub
Restez informé sur les nouvelles publications de la CEI. Just Published détaille deux fois par mois les nouvelles
publications parues. Disponible en-ligne et aussi par email.
ƒ Electropedia: www.electropedia.org
Le premier dictionnaire en ligne au monde de termes électroniques et électriques. Il contient plus de 20 000 termes et
définitions en anglais et en français, ainsi que les termes équivalents dans les langues additionnelles. Egalement appelé
Vocabulaire Electrotechnique International en ligne.
ƒ Service Clients: www.iec.ch/webstore/custserv/custserv_entry-f.htm
Si vous désirez nous donner des commentaires sur cette publication ou si vous avez des questions, visitez le FAQ du
Service clients ou contactez-nous:
Email: csc@iec.ch
Tél.: +41 22 919 02 11
Fax: +41 22 919 03 00
IEC 61753-111-7 ®
Edition 1.0 2009-11
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Fibre optic interconnecting devices and passive components performance
standard –
Part 111-7: Sealed closures for category A – Aerial
Dispositifs d'interconnexion et composants passifs à fibres optiques norme de
qualité de fonctionnement –
Partie 111-7: Boîtiers scellés pour catégorie A – Aériens
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
T
CODE PRIX
ICS 33.180.20 ISBN 978-2-88910-559-5
– 2 – 61753-111-7 © IEC:2009
CONTENTS
FOREWORD.3
INTRODUCTION.5
1 Scope.6
2 Normative references.6
3 Terms, definitions and abbreviations .7
3.1 Terms and definitions .7
3.2 Abbreviations.8
4 General requirements .9
4.1 Storage, transportation and packaging .9
4.2 Marking and identification .9
4.3 Materials .9
4.4 Closure overpressure safety .10
4.5 Test report.10
5 Test.10
5.1 General .10
5.2 Test specimen preparation.10
5.3 Test and measurement methods .11
5.4 Installation or intervention.11
5.5 Pass/fail criteria.11
6 Performance requirements.12
6.1 Sample size.12
6.2 Sealing, optical and appearance performance criteria .12
6.3 Mechanical sealing performance requirements.13
6.4 Environmental sealing performance requirements .15
6.5 Mechanical optical performance requirements.15
6.6 Environmental optical performance requirements .17
Annex A (normative) Sample definition .18
Annex B (normative) Sample size.20
Annex C (normative) Intervention and reconfiguration/resplicing .21
Bibliography .23
Figure A.1 – Track joint configuration sample .18
Figure A.2 – Distribution joint configuration sample.19
Table 1 – Tightness, optical and appearance performance criteria .12
Table 2 – Mechanical sealing performance requirements .13
Table 3 – Environmental sealing performance requirements .15
Table 4 – Mechanical optical performance requirements.15
Table 5 – Environmental optical performance requirements .17
Table A.1 – Fibre type for testing.18
Table B.1 – Sample size.20
61753-111-7 © IEC:2009 – 3 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
FIBRE OPTIC INTERCONNECTING DEVICES
AND PASSIVE COMPONENTS
PERFORMANCE STANDARD –
Part 111-7: Sealed closures for category A –
Aerial
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61753-111-7 has been prepared by subcommittee 86B: Fibre optic
interconnecting devices and passive components, of IEC technical committee 86: Fibre optics.
The text of this standard is based on the following documents:
FDIS Report on voting
86B/2904/FDIS 86B/2934/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
– 4 – 61753-111-7 © IEC:2009
A list of all parts of IEC 61753 series, published under the general title Fibre optic
interconnecting devices and passive components – Performance standard, can be found on the
IEC website.
Future standards in this series will carry the new general title as cited above. Titles of existing
standards in this series will be updated at the time of the next edition.
The committee has decided that the contents of this publication will remain unchanged until the
maintenance result date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
61753-111-7 © IEC:2009 – 5 –
INTRODUCTION
Performance standards for sealed closures define the requirements for standard optical
performance under a set of specified conditions. This part of IEC 61753 contains a series or a
set of tests and measurements with clearly stated conditions, severities and pass/fail criteria.
The set of tests is intended to be a basis to prove the product’s ability to satisfy the
requirements of a specific application, market sector or user group.
A product that has been shown to meet all the requirements of this performance standard may
be declared as complying with this performance standard. Products having the same
classification from one manufacturer that satisfy this performance standard will operate within
the boundaries set by the performance standard. There is no guarantee that products from
different manufacturers, having the same classification and which conform to the same
performance standard, will provide an equivalent level of performance when they are used
together.
Conformance with IEC environmental policy according to IEC Guide 109 and concerning the
need to reduce the impact on the natural environment of fibre optic closures during all phases
of their life – from acquiring materials to manufacturing, distribution, use, and end-of-life
treatment (i.e. re-use, recycling (recovery and disposal)) are not part of this standard, but will
be covered in the generic specification.
Conformance to a performance standard demonstrates that a product has passed a design
verification test. It is not a guarantee of lifetime assured performance or reliability. Reliability
testing must be the subject of a separate test schedule, where the tests and severities selected
are such that they are truly representative of the requirements of this reliability test programme.
Consistency of manufacture should be maintained using a recognised Quality Assurance
programme whilst the reliability of the product should be evaluated using the procedures
recommended in IEC 62005 series.
Tests and measurements are selected from the IEC 61300 series.
– 6 – 61753-111-7 © IEC:2009
FIBRE OPTIC INTERCONNECTING DEVICES
AND PASSIVE COMPONENTS
PERFORMANCE STANDARD –
Part 111-7: Sealed closures for category A –
Aerial
1 Scope
This part of IEC 61753 contains the minimum test and measurement requirements and
severities which a sealed fibre optic closure must satisfy in order to be categorised as meeting
the IEC standard for category A – aerial, as defined in Annex A of IEC 61753-1. Free breathing
closures are not covered in this standard.
2 Normative references
The following referenced documents are indispensable for the application of this document. For
dated references, only the edition cited applies. For undated references, the latest edition of
the referenced document (including any amendments) applies.
IEC 60068-2-10, Environmental testing – Part 2-10: Tests – Test J and guidance: Mould growth
IEC 60721-3-2, Classification of environmental conditions – Part 3: Classification of groups of
environmental parameters and their severities – Section 2: Transportation
IEC 60793-2-50:2008, Optical fibres – Part 2-50: Product specifications – Sectional
specification for class B single-mode fibres
IEC 61300-1, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 1: General and guidance
IEC 61300-2-1, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-1: Tests – Vibration (sinusoidal)
IEC 61300-2-4, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-4: Tests – Fibre/cable retention
IEC 61300-2-5, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-5: Tests – Torsion (available in English only)
IEC 61300-2-9, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-9: Tests – Shock
IEC 61300-2-11, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-11: Tests – Axial compression
IEC 61300-2-12:2009, Fibre optic interconnecting devices and passive components – Basic
test and measurement procedures – Part 2-12: Tests – Impact
___________
This publication was withdrawn in 2002. A project is currently under consideration.
61753-111-7 © IEC:2009 – 7 –
IEC 61300-2-22, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-22: Tests – Change of temperature
IEC 61300-2-26, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-26: Tests – Salt mist
IEC 61300-2-33, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-33: Tests – Assembly and disassembly of fibre optic
closures
IEC 61300-2-37, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-37: Tests – Cable bending for fibre optic closures
IEC 61300-2-38:2006, Fibre optic interconnecting devices and passive components – Basic
test and measurement procedures – Part 2-38: Tests – Sealing for pressurized fibre optic
closures
IEC 61300-3-1, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 3-1: Examinations and measurements – Visual examination
IEC 61300-3-3:2009, Fibre optic interconnecting devices and passive components – Basic test
and measurement procedures – Part 3-3: Examinations and measurements – Active monitoring
of changes in attenuation and return loss (available in English only)
IEC 61300-3-28, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 3-28: Examinations and measurements – Transient loss
IEC 61753-1:2007, Fibre optic interconnecting devices and passive components performance
standard – Part 1: General and guidance for performance standards
IEC 62134-1, Fibre optic interconnecting devices and passive components – Fibre optic
closures – Part 1: Generic specification
ISO 4892-3:2006, Plastics – Methods of exposure to laboratory light sources – Part 3:
Fluorescent UV lamps
3 Terms, definitions and abbreviations
For the purposes of this document, the following terms, definitions and abbreviations apply.
3.1 Terms and definitions
3.1.1
distribution joint
splice closure that allows easy fibre access, maintenance, re-arrangement and addition of fibre
circuits or passive optical components
NOTE Accessing fibre circuits must not cause any transmission degradation or disruption in other operational fibre
circuits. Storage of continuous fibres and fibre cable elements is allowed, for example loose tubes passing through
the closure. This closure is typically used in access and distribution networks.
3.1.2
excursion loss
change in optical loss during slow variations of environmental parameters
– 8 – 61753-111-7 © IEC:2009
3.1.3
fibre management system
system to control, protect and store fibres from the incoming to the outgoing fibres
3.1.4
free breathing closure
closure that cannot hold an overpressure. Water ingress and/or limited dust ingress is allowed
3.1.5
intervention
gain access to modify, add, remove or repair fibre circuits, splices, connectors or other
components between the incoming and outgoing cables of an existing closure
3.1.6
installation
establishment and installation of a closure, by adding new circuits, splices, connectors and
other components, including the incoming and outgoing cables
3.1.7
installation conditions
circumstances that must be fulfilled for an installation, which includes; environmental
conditions, size interface between the closure or enclosure and the fibre management system,
optical performance, additional/special conditions and safety requirements
3.1.8
residual loss
change in optical loss of between initial and final measurements
3.1.9
sealed closure
watertight and dust tight closure that can hold an overpressure of at least 40 kPa
NOTE Since humidity can enter the closure by diffusion, it is not considered to be a hermetic sealed closure.
3.1.10
sealed pressurised closure
watertight and dust tight closure that can hold an overpressure of at least 98 kPa
3.1.11
track joint
splice closure that allows the splicing of at least two cables. It acts as a reinstatement of the
cable length
NOTE It will not be re-entered except for repair or reinstatement of damaged cables. This closure configuration is
typically used in trunk and junction networks.
3.1.12
transient loss
sudden variations in a circuit’s loss characteristics during:
a) manipulation of the entire closure or enclosure and its fibre management system;
b) access to adjacent circuits stored in the same closure or enclosure;
c) sudden effects induced by the external environment (e.g. vibration, shock)
3.2 Abbreviations
FMS Fibre Management System
SC Single Circuit
61753-111-7 © IEC:2009 – 9 –
SE Single Element
ME Multiple Element
MR Multiple Ribbon
4 General requirements
4.1 Storage, transportation and packaging
The classes of environmental conditions and their severities to which closures may be exposed
during transportation from one place to another after being made ready for dispatch from the
manufacturer's works are defined in IEC 60721-3-2. Normal transportation time is considered
to be 30 days or less.
The product, in its original packaging, shall be suitable for normal public or commercial
transportation and storage in weather protected non-temperature controlled storage
environments.
4.2 Marking and identification
Marking of the closure and its package shall be according to IEC 62134-1.
Product marking and identification shall survive the storage and transportation.
Each test sample should contain the following information at a minimum:
– manufacturer’s identification mark or logo;
– product designation, model or type;
– one of the following: lot number, batch number, date (at least month and year) of
production or serial number;
– expiry date (at least year) if the product contains components with a limited shelf-life.
4.3 Materials
For all applied materials, a Material Safety Data Sheet shall be made available upon request.
The materials of the closure and fibre management system shall be compatible with the other
materials or solvents that can come into contact with it, for example cable filling compounds
and degreasing agents.
All materials that can come in contact with personnel shall meet appropriate health and safety
regulations.
The effect of UV light on all polymeric materials that are directly exposed to the environment,
shall not adversely affect the product’s performance. UV test shall be according to ISO 4892-3
Mode 1 lamp type 2. The effect of UV light shall be determined by measuring a suitable
property (e.g. tensile strength) both before and after exposure of the material slabs.
Polymeric materials shall not support mould growth causing mechanical degradation of the
materials. Mould growth shall be tested according to IEC 60068-2-10. The effect of mould
growth shall be determined by measuring a suitable property (e.g. tensile strength) both before
and after exposure of the material slabs.
Metallic elements shall be corrosion resistant. Dissimilar metals should not be used in contact
with each other unless they are suitably finished to prevent electrolytic corrosion.
– 10 – 61753-111-7 © IEC:2009
Materials which are not specified or which are not specifically described are left to the
discretion of the manufacturer.
4.4 Closure overpressure safety
Special attention should be taken when opening sealed closures that are carrying an
overpressure. Overpressure can build up in sealed closures due to temperature differentials,
atmospheric pressure changes over a period of time, flash testing of the seals after installation
or incorrect installation techniques. Care should be taken when opening a sealed closure.
Provisions shall be made that overpressure is exhausted when opening the closure prior to
complete removal of the cover.
4.5 Test report
Conformance to a performance standard shall be supported by a test report. The test report
shall clearly demonstrate that the tests were carried out in accordance with the requirements of
the performance standard and provide full details of the tests together with a pass/fail
declaration. An analysis of the cause of the failure shall be undertaken and any corrective
actions taken shall be described.
If design changes are made a risk assessment should be carried out to determine whether full
or partial requalification should be done.
5 Test
5.1 General
The mechanical and environmental performance of a closure is vital to the optical cabling
system. The purpose of testing is to demonstrate that the closure can survive under defined
environmental conditions, without irreversible or reversible failures and perform according to
the requirements.
The performance test procedure of a closure shall:
– evaluate the product for 3 basic acceptance criteria: sealing, mechanical integrity and
optical transmission requirements;
– simulate the effects of exposure to the environment in which it will be installed;
– simulate installation and intervention conditions.
Optical performance testing is accomplished by subjecting the test specimen to a number of
mechanical and environmental conditions and measuring any optical performance deviations at
prescribed intervals during and after completion of each test.
5.2 Test specimen preparation
Sealing performance test samples shall be provided with an air pressure test access valve. The
length of the cables extending the closure shall be at least 1 m. The free ends of the cables
shall be sealed. Each applicable cable type with minimum and maximum cable dimensions
shall be represented in the test program. When applicable, open closure ports shall be sealed
with a cap.
Optical test samples shall be constructed in such a way that they will cover all allowed
functions as specified by the manufacturer, being “track joint “ configuration or “track joint and
distribution joint” configuration. This shall be realised by building optical circuits for each fibre
separation level (typical SC, SE, or ME splicing and uncut fibre storage). The type of fibre for
the optical test samples and the test sample preparation are single mode fibres as described in
Annex A.
61753-111-7 © IEC:2009 – 11 –
5.3 Test and measurement methods
All tests and measurements have been selected from the IEC 61300 series.
Unless otherwise stated in the individual test details, all attenuation measurements shall be
performed at 1 310 nm ± 25 nm, 1 550 nm ± 25 nm and 1 625 nm ± 25 nm for the
environmental optical tests, and at 1 550 nm ± 25 nm and 1 625 nm ± 25 nm for the
mechanical optical tests.
All optical losses indicated are referenced to the initial attenuation at the start of the test.
No deviation from the specified test method is allowed.
Effects that are due to the properties of the optical components themselves are not to be taken
into account for the evaluation of the closure system itself.
Closures under test shall be mounted and connected in accordance with the manufacturer's
guidelines.
Unless otherwise specified, tests should be carried out under standard atmospheric conditions
according to IEC 61300-1.
5.4 Installation or intervention
The minimum and maximum temperatures at which a closure may be installed (installation
conditions) or re-entered (intervention), are not necessarily equal to the maximum temperature
excursion of the environment in which it will reside, once installed. Accessing fibres and the
fibre management system inside the closure is typically done in a more controlled environment.
Closures and the fibre management system should be installable in the temperature range
between –5 °C and +45 °C for aerial applications (category A). Closure handling alone should
be possible at temperatures between –15 °C and +45 °C.
Typically, the following operations are carried out during an intervention:
• handling of closure;
• opening closure;
• getting access to fibres and splices (e.g. hinging, pivoting, sliding, removal of splice trays,
or other organiser components);
• breaking a splice, rerouting fibres and connecting to another fibre end;
• cutting one or more uncut fibres, rerouting and connecting to another fibre end;
• disconnecting a connector and mating with another connector (when applicable);
• adding organiser elements/components and connecting the fibres;
• closing and sealing the closure.
5.5 Pass/fail criteria
A product will have met the requirements of this standard provided no failures occur in any test.
In the event of a failure occurring on a sealing performance test sample, the test shall be re-
run using a sample size double that of the original.
Due to the complexity of the optical test samples, consecutive testing on the same optical
sample is allowed. In case of a failure during the consecutive testing, a new sample shall be
prepared and the failed test shall be re-done.
– 12 – 61753-111-7 © IEC:2009
6 Performance requirements
6.1 Sample size
A detailed description of the sample size can be found in Annex B.
6.2 Sealing, optical and appearance performance criteria
Table 1 – Tightness, optical and appearance performance criteria
No. Test Requirement Details
1 Sealing for No emission of air bubbles Method: IEC 61300-2-38, Method A
pressurised indicating a leak
Test temperature:
23 °C ± 3 °C
closures of fibre
optic devices –
Test pressure: Internal overpressure
sealing
40 kPa ± 2 kPa (Note 1)
performance
after test
Immersion depth: Just below the surface of the water
Duration: 15 min
Pre-conditioning Sample should be conditioned to
procedure: room temperature for at least 2 h
2 Visual No defects which would affect Method: IEC 61300-3-1
examination functionality of the closure
Examination: Product shall be checked with the
naked eye
3 Active Excursion losses: Method: IEC 61300-3-3, Method 1
monitoring of
δIL ≤ 0,2 dB at 1 310 nm and
change in Wavelengths: 1 310 nm ± 25 nm
1 550 nm per incoming fibre
attenuation and
during test. 1 550 nm ± 25 nm
return loss
1 625 nm ± 25 nm
(Note 2)
δIL ≤ 0,5 dB at 1 625 nm per
Source stability:
Within ± 0,05 dB over the
incoming fibre during test.
measuring period
Detector linearity: Within ± 0,05 dB over the dynamic
range to be measured
Residual losses:
Measurements Before, during and after the test
δIL ≤ 0,1 dB at 1 310 nm,
required:
1 550 nm and 1 625 nm per
incoming fibre after test
Sampling rate: Every 10 min
4 Transient loss Transient losses: Method: IEC 61300-3-28
(Note 2)
δIL ≤ 0,5 dB at 1 550 nm per
Wavelengths: 1 550 nm ± 25 nm
active circuit during test.
1 625 nm ± 25 nm
δIL ≤ 1 dB at 1 625 nm per
active circuit during test.
Source stability:
Within ± 0,05 dB over the
measuring period
Detector linearity:
Within ± 0,05 dB over the dynamic
Residual losses:
range to be measured
δIL ≤ 0,1 dB at 1 550 nm and
Measurements Before, during and after the test
1 625 nm per active circuit
required:
after test
Active circuit: 10 incoming fibres in series
NOTE 1 For products used in pressurised networks, all testing should be carried out at 98,0 kPa ± 9,8 kPa over-
pressure instead of 40 kPa over-pressure.
NOTE 2 All optical losses indicated are referenced to the initial attenuation at the start of the test.
61753-111-7 © IEC:2009 – 13 –
6.3 Mechanical sealing performance requirements
Table 2 – Mechanical sealing performance requirements
No. Test Requirement Details
5 Vibration Sealing performance (test 1) Method: IEC 61300-2-1
(sinusoidal)
Visual examination (test 2)
Frequency range: 5 Hz – 500 Hz at 1 octave/min
Amplitude
3 mm or 10 m/s (~ 1 g ) maximum
n
/acceleration force:
Cross-over frequency: 9 Hz
Number of sweeps 10 sweeps (5-500-5)
Number of axes: 3 mutually perpendicular
Test temperature:
+23 °C ± 3 °C
Test pressure:
Internal overpressure 0 kPa ± 2 kPa
Pre-conditioning Sample should be conditioned at
procedure: room temperature for at least 2 h
6 Cable retention Sealing performance (test 1) Method: IEC 61300-2-4
Visual examination (test 2)
Test temperatures:
–15 °C ± 2 °C and +45 °C ± 2 °C
Load:
∅Cable (mm)/45*1 000 N
or 1000 N maximum
Duration: 1 h per cable
Test pressure:
Internal overpressure 0 kPa ± 2 kPa
at room temperature
Pre-conditioning Sample should be conditioned at the
procedure: specified temperature for at least 4 h
7 Axial Visual examination (test 2) Method: IEC 61300-2-11
compression of
No movement of central
Test temperature:
central +23 °C ± 3 °C
strength member by more
strength
than 5 mm
Load: 450 N on central strength member
member
Duration: 30 min per strength member
Pre-conditioning Sample should be conditioned at
procedure: room temperature for at least 2 h
8 Cable bending Sealing performance (test 1) Method: IEC 61300-2-37
Visual examination (test 2)
Test temperatures:
–15 °C ± 2 °C and +45 °C ± 2 °C
Force: 30° or maximum 500 N
Force application: 400 mm from end of seal (Note)
Number of cycles: 5 cycles per cable
Test pressure: Internal overpressure 0 kPa ± 2 kPa
at room temperature
Pre-conditioning Sample should be conditioned at the
procedure: specified temperature for at least 4 h
– 14 – 61753-111-7 © IEC:2009
Table 2 (continued)
No. Test Requirement Details
9 Torsion/twist Sealing performance (test 1) Method: IEC 61300-2-5
Pressure loss (test 2)
Test temperatures: –15 °C ± 2 °C and +45 °C ± 2 °C
Visual examination
Torque: 90° or maximum 50 Nm
(test 3)
Force application: 400 mm from end of seal (Note)
Number of cycles: 5 cycles per cable
Test pressure:
Internal overpressure 0 kPa ± 2 kPa
at room temperature
Pre-conditioning Sample should be conditioned at the
procedure: specified temperature for at least 4 h
10 Impact Sealing performance (test 1) Method: IEC 61300-2-12, Method A
(free fall)
Test temperatures: –15 °C ± 2 °C and +45 °C ± 2 °C
Severity: Drop height 75 cm
Number of drops: 1
Test pressure:
Internal overpressure 0 kPa ± 2 kPa
at room temperature
Pre-conditioning Sample should be conditioned at the
procedure: specified temperature for at least 4 h
11 Impact Sealing performance (test 1) Method: IEC 61300-2-12, Method B
Visual examination
Test temperatures: –15 °C ± 2 °C and +45 °C ± 2 °C
(test 2)
Impact tool: Steel ball of 1 kg
Drop height: 1 m
Impact locations: 0°, 90°, 180° and 270°
Number of impacts: 1 per location
Test pressure:
Internal overpressure 0 kPa ± 2 kPa
at room temperature
Pre-conditioning Sample should be conditioned to
procedure: specified temperature for at least 4 h
12 Assembly and Sealing performance (test 1) Method: IEC 61300-2-33
disassembly of
Visual examination (test 3)
Test temperature:
closures +23 °C ± 3 °C
Conditioning between Ageing of minimum 1 temperature
each re-entry: cycle as specified in Test 13
Number of re-entries: 10
NOTE For rigid cables with diameter Ø> 25 mm the clamping distance should be increased to 1 000 mm.
61753-111-7 © IEC:2009 – 15 –
6.4 Environmental sealing performance requirements
Table 3 – Environmental sealing performance requirements
No. Test Requirement Details
13 Change of Sealing performance (test 1) Method: IEC 61300-2-22
temperature
Visual examination (test 2)
Extreme temperatures: –40 °C ± 2 °C and +65 °C ± 2 °C
Dwell time: 4 h
Rate of change 1 °C/min
Number of cycles: 20
Test pressure: Internal overpressure
0 kPa ± 2 kPa sealed at room
temperature
14 Salt mist Sealing performance (test 1) Method: IEC 61300-2-26
Visual examination (test 2) Test temperatures:
+35 °C ± 2 °C
Salt solution: 5 % NaCl (pH 6,5-7,2)
Duration: 5 days
Test pressure: Internal overpressure
0 kPa ± 2 kPa sealed at room
temperature
6.5 Mechanical optical performance requirements
Table 4 – Mechanical optical performance requirements
No. Test Requirement Details
15 Vibration Transient loss (test 4) Method: IEC 61300-2-1
(sinusoidal)
Visual examination (test 2)
Test temperature: +23 °C ± 3 °C
Frequency range: 5 Hz - 500 Hz at 1 octave/min
Amplitude 3 mm or
/acceleration force:
10 m/s (~ 1 g ) maximum
n
Cross-over frequency: 9 Hz
Number of sweeps 10 sweeps (5-500-5)
No. of axes: 3 mutually perpendicular
Optical circuit: 10 live fibres placed in series
16 Shock Transient loss (test 4) Method: IEC 61300-2-9
Visual examination (test 2)
Test temperature:
+23 °C ± 3 °C
Wave form: half sine
Duration pulse: 11 ms
Acceleration force:
150 m/s (~ 15 g )
n
Number shocks 3 up and 3 down per axis
No. of axes: 3 mutually perpendicular
Optical circuit: 10 live fibres placed in series
– 16 – 61753-111-7 © IEC:2009
Table 4 (continued)
No. Test Requirement Details
17 Cable bending Transient loss (test 4) Method: IEC 61300-2-37
Visual examination (test 2)
Test temperatures: –15 °C ± 2 °C and +45 °C ± 2 °C
Force: 30° or maximum 500 N
Force application: 400 mm from end of seal (Note)
Number of cycles: 5 cycles per cable
Optical circuit: 10 live fibres in series
18 Torsion/twist Transient loss (test 4) Method: IEC 61300-2-5
Visual examination (test 2)
Test temperature: –15 °C ± 2 °C and +45 °C ± 2 °C
Torque: 90° or maximum 50 Nm
Force application: 400 mm from end of seal (Note)
Number of cycles: 5 cycles per cable
Optical circuit: 10 live fibres in series
19 Assembly and Transient loss (test 5) Method: IEC 61300-2-33
disassembly of
Visual examination (test 3)
Test temperature: +23 °C ± 3 °C
closures
Operations: All manipulations that will normally occur
during an intervention after initial
Operations shall be carried
installation (see Annex C). These are
out on fibres in splice trays,
typically:
installed between other
active splice trays (that
1. Moving closure to working location.
contain the 10 live fibres)
Unloop cables and expose closure to
typical handling operations like:
torsion (−90°/+90°) and bending
For the distribution joint (−30°/+30°) of closure.
configuration only
2. Opening closure. Gaining access to
previously installed fibres in the
organiser system.
Circuit separation (SC, SE,
SR, ME, MR) if applicable 3. Adding /installing drop cables.
to the closure
4. Breaking splice and splicing to other
fibre.
5. Cutting one or more uncut fibres and
splicing them to other fibres.
6. Adding splicing trays.
7. Closing the closure and looping
cables. Exposing closure to typical
handling operations like: torsion
(−90°/+90°) and bending (−30°/+30°)
of closure.
Optical circuit: Ten live fibres placed in series
NOTE For rigid cables with diameter Ø> 25 mm the clamping distance should be increased to 1 000 mm.
61753-111-7 © IEC:2009 – 17 –
6.6 Environmental optical performance requirements
Table 5 – Environmental optical performance requirements
No. Test Requirement Details
20 Change of Change in attenuation Method: IEC 61300-2-22
temperature (test 3)
Low temperature: –40 °C ± 2 °C
Visual examination
High temperature:
(test 2) + 65 °C ± 2 °C
Duration at temperature 4 h
extreme:
Rate of change of
1 °C/min
temperature:
Number of cycles: 20
Measurements required: Before, during (max. interval 10 min)
and after the test.
Recovery procedure: 4 h at normal ambient conditions
– 18 – 61753-111-7 © IEC:2009
Annex A
(normative)
Sample definition
A.1 Fibre type for testing
Table A.1 – Fibre type for testing
Fibre type: Dispersion unshifted – IEC 60793-2-50, Type B1.1
Proof stress strain: ≥ 1 %
Mode field diameter at 1 310 nm:
9,3 μm ± 0,7 μm
Mode field diameter at 1 550 nm:
10,5 μm ± 1,0 μm
Cabled fibre cut off wavelength: ≤ 1 260 nm
1 550 nm loss performance: < 0,5 dB for 100 turns on 60 mm mandrel diameter
Cladding diameter: 125 μm ± 1 μm
Non-coloured primary coating diameter:
245 μm ± 10 μm
Coloured primary coating diameter:
250 μm ± 15 μm
A.2 Closure test sample configuration
The optical test sample will be built with 2 closures: one configured as track joint (splicing
cables together) and one configured as distribution joint (access point for connections to
customers). The selected cable has to be suitable for the selected temperature range.
Step 1: Both extremities of a looped cable are termina
...