IEC 60079-1:2014/COR1:2018
(Corrigendum)Corrigendum 1 - Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
Corrigendum 1 - Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
Corrigendum 1 - Atmosphères explosives - Partie 1: Protection du matériel par enveloppes antidéflagrantes "d"
General Information
Relations
Standards Content (Sample)
IEC 2018
INTERNATIONAL ELECTROTECHNICAL COMMISSION
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE
____________
IEC 60079-1 IEC 60079-1
Edition 7.0 2014-06 Édition 7.0 2014-06
EXPLOSIVE ATMOSPHERES – ATMOSPHERES EXPLOSIVES –
Part 1: Equipment protection by flameproof Partie 1: Protection du matériel par enveloppes
enclosures "d" antidéflagrantes "d"
...
This May Also Interest You
IEC TS 60079-44:2023, which is a Technical Specification, is to provide guidance to establish recommended minimum criteria to determine roles, establish expectations of the necessary skills and evidence of competence to assess and manage the competence of personnel conducting work in or associated with hazardous areas. The purpose of this document is to provide guidance to establish:
• recommended minimum criteria to determine roles,
• expectations of the necessary skills, and
• evidence of competence
in order to assess and manage the competence of personnel who are conducting work in or associated with hazardous areas.
This document provides examples and recommendations of minimum levels of competence for typical roles associated with hazardous areas by addressing the knowledge, skills, or abilities that is expected of personnel. Additionally, examples of the evidence of competence expected for each role are provided.
The aim of tThis document is to assist in defining, assessing, and managing unique requirements for the competence of individuals working in or associated with installations where an explosive atmosphere could be present. Such a programme could be specific to a facility or used in conjunction with other regulatory requirements where they exist. The competencies for conducting work in a hazardous area are in addition to any competencies which may apply for the general type of work being undertaken (for example, professional credentials, electrical, non-electrical, operations, design).
This document applies to both electrical and non-electrical applications.
This document identifies the minimum level of knowledge and skills required to work in hazardous areas and the specific competence required for work associated with equipment for explosive atmospheres (commonly termed ‘Ex Equipment’) and the standards to which competence is to be assessed and attributed.
The purpose of this document is to provide guidance to establish:
• recommended minimum criteria to determine roles,
• expectations of the necessary skills, and
• evidence of competence
The principal application of this specification document is for personnel dealing with explosion-protected and associated equipment for use in explosive atmospheres, including the following work functions:
• Classification of areas;
• Producing, processing or servicing functions in a hazardous area and not directly involved in installing, maintaining or repairing explosion-protected equipment and systems;
• Designing, commissioning and maintaining explosion-protection strategies and equipment;
• Selecting, installing, testing and maintaining explosion-protected equipment and systems in hazardous areas;
• Inspecting hazardous area equipment, systems and installations;
• Overhauling, repairing and modifying explosion-protected equipment;
• Management of the Ex aspects of the facility.
- Technical specification29 pagesEnglish languagesale 15% off
- Standard3 pagesEnglish and French languagesale 15% off
- Standard3 pagesEnglish languagesale 15% off
- Standard5 pagesEnglish and French languagesale 15% off
- Standard2 pagesEnglish languagesale 15% off
- Standard2 pagesEnglish languagesale 15% off
IEC 60079-31:2022 is applicable to equipment protected by enclosure and surface temperature limitation for use in explosive dust atmospheres. It specifies requirements for design, construction and testing of Ex Equipment and Ex Components. This document supplements and modifies the general requirements of IEC 60079-0. Where a requirement of this document conflicts with a requirement of IEC 60079-0, the requirement of this document takes precedence. This document does not apply to dusts of explosives, which do not require atmospheric oxygen for combustion, or to pyrophoric substances. This document does not apply to Ex Equipment or Ex Components intended for use in underground parts of mines as well as those parts of surface installations of such mines endangered by firedamp and/or combustible dust. This document does not take account of any risk due to an emission of flammable or toxic gas from the dust. This third edition cancels and replaces the second edition published in 2013. This edition constitutes a technical revision. Main significant changes from the previous edition are:
1) Document has been restructured from edition 2
2) Fault current rating of interrupting contacts in clauses 4.3.1 and 4.4.1, major change type C1
3) Cells and batteries in clauses 4.3.5.1 and 4.4.5.1, major change type C2
4) Overload or malfunction condition for the determination of temperature class for "tb" converter fed rotating electric machines, major change type C3
5) Additional requirements for entry devices with dust ignition protection by enclosure "t", major change type C4
Information about the background of ‘Major Technical Changes’
C1 – Ex Equipment having Level of Protection "ta" shall be rated for connection to a circuit with a prospective short circuit current of not greater than 1.5 kA. For Ex Equipment having Level of Protection "tb" or "tc" which is intended for mains connection and intended to interrupt fault current above 10kA, the equipment shall have a rated maximum short circuit withstand current, be tested according to 6.1.1.1, and be marked according to Clause 7.
C2 – For Ex Equipment having Level of Protection "ta" which contains a cell or battery, only a sealed cell or battery shall be used. For Ex Equipment having Level of Protection "tb" and "tc" where there are sparking contacts or hot surfaces, and which contains a cell or battery, only a sealed cell or battery shall be used.
C3 – Table 2 now includes malfunction conditions for temperature class determination of Level of Protection "tb" converter-fed electric machines.
C4 – Annex A added for entry devices with Type of Protection "t" including cable transit devices.
The contents of the corrigendum of October 2023 have been included in this copy.
- Standard61 pagesEnglish languagesale 15% off
- Standard39 pagesEnglish and French languagesale 15% off
IEC 62990-2:2021 gives guidance on the selection, installation, use and maintenance of electrical equipment used for the measurement of toxic gases and vapours in workplace atmospheres. The primary purpose of such equipment is to ensure safety of personnel and property by providing an indication of the concentration of a toxic gas or vapour and warning of its presence.
This document is applicable to equipment whose purpose is to provide an indication, alarm or other output function to give a warning of the presence of a toxic gas or vapour in the atmosphere and in some cases to initiate automatic or manual protective actions. It is applicable to equipment in which the sensor automatically generates an electrical signal when gas is present.
For the purposes of this document, equipment includes:
a) fixed equipment;
b) transportable equipment, and
c) portable equipment.
This document is intended to cover equipment defined within IEC 62990-1, but can provide useful information for equipment not covered by that document.
- Standard62 pagesEnglish languagesale 15% off
- Standard129 pagesEnglish and French languagesale 15% off
IEC 60079-26:2021 specifies requirements for construction, testing and marking for Ex Equipment that contains parts of the equipment with different Equipment Protection Levels (EPLs) and a separation element. This equipment is mounted across a boundary where different EPLs are required, for example between different gas hazardous areas, dust hazardous areas or gas hazardous areas adjacent to dust hazardous areas.
Separation elements are considered for both electrical and non-electrical equipment. If mechanical energy can be transformed into a potential ignition source, additionally an ignition hazard assessment in accordance with ISO 80079-36 is performed and appropriate measures are undertaken.
This document also specifies requirements for the combination of two Types of Protection, each with EPL Gb, to achieve EPL Ga.
This document supplements and modifies the general requirements of IEC 60079-0. Where a requirement of this document conflicts with a requirement of IEC 60079-0, the requirement of this document takes precedence. This fourth edition cancels and replaces the third edition and constitutes a technical revision.
Please see the IEC 60079-26:2020 foreword for a description of the main changes with respect to the previous edition.
- Standard47 pagesEnglish and French languagesale 15% off
- Standard2 pagesEnglish languagesale 15% off
- Standard9 pagesEnglish and French languagesale 15% off
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.