Amendment 2 - Lamp controlgear - Part 2-3: Particular requirements for a.c. supplied electronic ballasts for fluorescent lamps

Amendement 2 - Appareillages de lampes - Partie 2-3: Prescriptions particulières pour les ballasts électroniques alimentés en courant alternatif pour lampes fluorescentes

General Information

Status
Published
Publication Date
22-Jan-2006
Technical Committee
Drafting Committee
Current Stage
DELPUB - Deleted Publication
Completion Date
19-May-2011
Ref Project

Relations

Buy Standard

Standard
IEC 61347-2-3:2000/AMD2:2006 - Amendment 2 - Lamp controlgear - Part 2-3: Particular requirements for a.c. supplied electronic ballasts for fluorescent lamps Released:1/23/2006 Isbn:283188411X
English and French language
13 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


NORME CEI
INTERNATIONALE
IEC
61347-2-3
INTERNATIONAL
STANDARD
AMENDEMENT 2
AMENDMENT 2
2006-01
Amendement 2
Appareillages de lampes –
Partie 2-3:
Prescriptions particulières pour les ballasts
électroniques alimentés en courant alternatif
pour lampes fluorescentes
Amendment 2
Lamp controlgear –
Part 2-3:
Particular requirements for a.c. supplied
electronic ballasts for fluorescent lamps
© IEC 2006 Droits de reproduction réservés ⎯ Copyright - all rights reserved
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch
CODE PRIX
G
Commission Electrotechnique Internationale
PRICE CODE
International Electrotechnical Commission
ɆɟɠɞɭɧɚɪɨɞɧɚɹɗɥɟɤɬɪɨɬɟɯɧɢɱɟɫɤɚɹɄɨɦɢɫɫɢɹ
Pour prix, voir catalogue en vigueur
For price, see current catalogue

– 2 – 61347-2-3 Amend. 2 © CEI:2006
AVANT-PROPOS
Le présent amendement a été établi par le sous-comité 34C: Appareils auxiliaires pour
lampes, du comité d'études 34 de la CEI: Lampes et équipements associés.
Le texte de cet amendement est issu des documents suivants:
FDIS Rapport de vote
34C/707/FDIS 34C/715/RVD
Le rapport de vote indiqué dans le tableau ci-dessus donne toute information sur le vote ayant
abouti à l'approbation de cet amendement.
Le comité a décidé que le contenu de cet amendement et de la publication de base ne sera
pas modifié avant la date de maintenance indiquée sur le site web de la CEI sous
"http://webstore.iec.ch" dans les données relatives à la publication recherchée. A cette date,
la publication sera
• reconduite,
• supprimée,
• remplacée par une édition révisée, ou
• amendée.
_____________
Page 2
SOMMAIRE
Remplacer le titre de la Figure 2 par le suivant:
Figure 2 − Limites pour le courant de fuite capacitif des lampes fluorescentes fonctionnant
en HF
Page 10
3 Définitions
3.1
ballast électronique alimenté en court alternatif
La correction ne concerne que le texte anglais.
Page 12
Supprimer la définition 3.2 et renuméroter les définitions 3.3 et 3.4, qui deviennent donc,
respectivement, 3.2 et 3.3.
Supprimer les définitions 3.6 et 3.7 existantes, puis renuméroter les définitions 3.5, 3.8 et 3.9
existantes, qui deviennent, respectivement en 3.4, 3.5 et 3.6.
La correction de la nouvelle définition 3.5 ne concerne que le texte anglais.

61347-2-3 Amend. 2 © IEC:2006 – 3 –
FOREWORD
This amendment has been prepared by subcommittee 34C: Auxiliaries for lamps, of IEC
technical committee 34: Lamps and related equipment.
The text of this amendment is based on the following documents:
FDIS Report on voting
34C/707/FDIS 34C/715/RVD
Full information on the voting for the approval of this amendment can be found in the report
on voting indicated in the above table.
The committee has decided that the contents of this amendment and the base publication will
remain unchanged until the maintenance result date indicated on the IEC web site under
"http://webstore.iec.ch" in the data related to the specific publication. At this date, the
publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
_____________
Page 3
CONTENTS
Replace the title of Figure 2 by the following:
Figure 2 − Limits for capacitive leakage current of HF-operated fluorescent lamps
Page 11
3 Definitions
3.1
a.c. supplied electronic ballast
Replace, in the text of this definition, ”tubular fluorescent lamps” by “fluorescent lamps”.
Page 13
Delete definition 3.2 and renumber definitions 3.3 and 3.4 as 3.2 and 3.3 respectively.
Delete definitions 3.6 and 3.7 and renumber definitions 3.5, 3.8 and 3.9 as 3.4, 3.5 and 3.6.
In the new definition 3.5, replace “tubular fluorescent lamps” by “fluorescent lamps”

– 4 – 61347-2-3 Amend. 2 © CEI:2006
Page 12
4 Prescriptions générales
La correction ne concerne que le texte anglais.
Page 14
7.1 Marquages obligatoires
Remplacer le texte de ce paragraphe par le suivant:
En accord avec les exigences du paragraphe 7.2 de la CEI 61347-1, les ballasts autres que
les ballasts intégrés doivent être marqués d'une manière claire et durable avec les
marquages obligatoires suivants:
a) les points a), b), c), d), e), k) et l) du paragraphe 7.1 de IEC 61347-1, conjointement avec
b) le symbole de mise à la terre, le cas échéant;
c) pour les ballasts à gradation, l’identification des bornes de commande;
d) déclaration de la tension maximale de fonctionnement (efficace) selon 15.2 entre
– bornes de sortie
– une borne de sortie quelconque et la terre.
Le marquage de chacune de ces deux valeurs doit se faire par incréments de 10 V quand
la tension de fonctionnement est inférieure ou égale à 500 V, et en incréments de 50 V
quand la tension de fonctionnement est supérieure à 500 V. Le marquage de la tension
maximale de fonctionnement est référencé dans deux cas, la valeur maximale entre les
bornes de sortie et la valeur maximale entre une borne de sortie et la terre. Il est accepté
de marquer seulement la plus élevée de ces deux valeurs.
Le marquage doit être U-OUT=.V.
Page 16
11 Résistance à l’humidité et isolement
Dans la note, re
...

Questions, Comments and Discussion