IEC 61000-3-3:2013/AMD2:2021/COR1:2022
(Amendment)Corrigendum 1 - Amendment 2 - Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤16 A per phase and not subject to conditional connection
Corrigendum 1 - Amendment 2 - Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤16 A per phase and not subject to conditional connection
General Information
Relations
Buy Standard
Standards Content (Sample)
IEC 61000-3-3:2013/AMD2:2021/ – 1 –
COR1:2022 © IEC 2022
INTERNATIONAL ELECTROTECHNICAL COMMISSION
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE
____________
IEC 61000-3-3:2013/AMD2:2021 IEC 61000-3-3:2013/AMD2 :2021
Edition 3.0 2013-05 Édition 3.0 2013-05
ELECTROMAGNETIC COMPATIBILITY (EMC) – COMPATIBILITÉ ÉLECTROMAGNÉTIQUE (CEM) –
Part 3-3: Limits – Limitation of voltage changes, Partie 3-3: Limites – Limitation des variations de
voltage fluctuations and flicker in public low- tension, des fluctuations de tension et du
voltage supply systems, for equipment with papillotement dans les réseaux publics
rated current ≤ 16 A per phase and not subject to d'alimentation basse tension, pour les matériels
conditional connection ayant un courant assigné ≤ 16 A par phase non
soumis à un raccordement conditionnel
CO RRI G E ND U M 1
Corrections to the French version appear after the English text.
Les corrections à la version française sont données après le texte anglais.
INTRODUCTION to the corrigendum
During the final editing of the text for IEC 61000-3-3:2013/AMD2:2021 (Edition 3), a mistake
occurred and the sentence “P shall not be evaluated” is not displayed as a separate paragraph.
lt
As a result, this could lead to a wrong interpretation of the text and to wrong Pass/Fail results.
This corrigendum is needed to clarify that the text “P shall not be evaluated” applies to all
lt
equipment in Clause A.16.
A.16 Coffee machines and tea machines
Replace the sixth and seventh paragraphs (i.e. the last two paragraphs) with the following:
For machines, which are designed to prepare exclusively complete pots for a number of cups,
during the 10 min measuring period for th
...