IEC 62733:2015/COR1:2017
(Corrigendum)Corrigendum 1 - Programmable components in electronic lamp controlgear - General and safety requirements
Corrigendum 1 - Programmable components in electronic lamp controlgear - General and safety requirements
Corrigendum 1 - Composants programmables dans les appareillages électroniques de lampes - Exigences générales et exigences de sécurité
General Information
Relations
Standards Content (Sample)
IEC 2017
INTERNATIONAL ELECTROTECHNICAL COMMISSION
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE
____________
IEC 62733 IEC 62733
Edition 1.0 2015-05 Édition 1.0 2015-05
PROGRAMMABLE COMPONENTS IN COMPOSANTS PROGRAMMABLES DANS LES
ELECTRONIC LAMP CONTROLGEAR – APPAREILLAGES ÉLECTRONIQUES
GENERAL AND SA
...
This May Also Interest You
IEC 61347-2-13:2024 specifies safety requirements for electronic controlgear for LED light sources for use on DC supplies up to 1 500 V or on AC supplies up to 1 000 V at 50 Hz or 60 Hz.
This document is applicable for electronic controlgear for LED light sources with an output voltage (RMS) not higher than 1 000 V.
This third edition cancels and replaces the second edition published in 2014 and Amendment 1:2016. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) alignment with respect to the fourth edition of IEC 61347-1:
- introduction of dated references to the fourth edition of IEC 61347-1 as appropriate;
- deletion of the clauses and subclauses which are either no longer relevant or now covered in IEC 61347-1;
b) update of normative references, introducing dated references where appropriate;
c) scope extension to 1 500 V for direct current;
d) scope clarification;
e) deletion of unused definitions;
f) revision of information and marking requirements;
g) new marking requirement "electronic controlgear for LED light sources";
h) new requirements for electronic controlgear for LED light sources with constant light output function or programmable current (additions to Clause 3, Clause 6, Clause 16 and Clause 18);
i) modification of requirements for the determination of the output working voltage (new Clause 17);
j) new requirements for the determination of the rated output characteristics (Clause 18).
- Standard33 pagesEnglish and French languagesale 15% off
IEC 61347-2-2:2024 specifies safety requirements for electronic step-down convertors for use on DC supplies of up to 1 500 V or AC supplies of up to 1 000 V at 50 Hz or 60 Hz, and with a rated output voltage ≤ 50 V (RMS) at a frequency deviating from the supply frequency, or 120 V ripple free DC between conductors and between any conductor and earth, associated with tungsten-halogen lamps as specified in IEC 60357, and other filament lamps.
This third edition cancels and replaces the second edition published in 2011. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) alignment with respect to the fourth edition of IEC 61347-1;
- introduction of dated references to the fourth edition of IEC 61347-1 as appropriate;
- deletion of the clauses and subclauses which are either no longer relevant or now covered in IEC 61347-1;
b) scope extension to 1 500 V for direct current;
c) scope clarification;
d) deletion of unused definitions;
e) revision of information and marking requirements;
f) revision of compliance conditions for the measurement of the output voltage during fault condition testing and during thermal testing.
- Standard21 pagesEnglish and French languagesale 15% off
IEC 61347-2-11:2024 specifies safety requirements for miscellaneous electronic circuits used with luminaires for use on DC supplies up to 1 500 V or on AC supplies up to 1 000 V at 50 Hz or 60 Hz.
This second edition cancels and replaces the first edition published in 2001 and Amendment 1: 2017. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) alignment with respect to the fourth edition of IEC 61347-1:
- introduction of dated references to the fourth edition of IEC 61347-1 as appropriate;
- deletion of clauses and subclauses which are either no longer relevant or now covered in IEC 61347-1;
b) scope extension to 1 500 V for direct current;
c) scope clarification;
d) revision of information and marking requirements;
e) addition of requirements for the determination of the output working voltage (new Clause 17).
- Standard21 pagesEnglish and French languagesale 15% off
IEC 61347-1:2024 specifies general safety requirements for controlgear for electric light sources for use on DC supplies up to 1 500 V or AC supplies up to 1 000 V at 50 Hz or 60 Hz.
This fourth edition cancels and replaces the third edition published in 2015 and Amendment 1:2017. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) complete review of document structure, including but not limited to what is individually described under items b) to s);
b) removal of requirements for electromagnetic controlgear;
c) addition of more specific requirements for control circuit insulation and corresponding marking;
d) merging of thermal test requirements for transformers into a new Clause 16;
e) clarification of specifications for the moisture resistance test;
f) update of the normative reference to standards of the transformer series IEC 61558;
g) correction of the normative reference for PCB testing with respect to flames and fire;
h) update of further normative references where appropriate;
i) allowance of an alternative DC electric strength test;
j) addition of specific provisions for the use of bridging capacitors;
k) update of fire hazard testing requirements;
l) introduction of requirements for PELV applications;
m) clearance distances now generally based on peak instead of RMS voltage values;
n) introduction of a new type of protected emergency lighting controlgear;
o) review and clarification of touch current and voltage requirements;
p) clarification of the test sequence for independent controlgear with respect to the application of the IEC 60598 series versus the IEC 61347 series;
q) introduction of reduced touch voltages and currents for interrupted DC voltage applications or pulse width modulation (PWM);
r) changes concerning the recommendations for electric strength routine testing;
s) merging of requirements for safety isolating controlgear from former Annex L into the main body of the document;
t) introduction of Annex N intended to address touch current measurement;
u) introduction of Annex O intended to provide information on document reorganization.
- Standard221 pagesEnglish and French languagesale 15% off
IEC 61347-2-12:2024 specifies safety requirements for electronic controlgear for use on AC supplies at 50 Hz or 60 Hz up to 1 000 V or DC supplies up to 1 000 V. The type of controlgear is a convertor that can contain igniting and stabilizing elements for operation of a discharge lamp under direct current or at a frequency that can deviate from the supply frequency.
This second edition cancels and replaces the first edition published in 2005 and Amendment 1:2010. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) introduction of dated references where appropriate;
b) clarification of sample item numbers;
c) addition of new information requirements (items v), w) and x) of IEC 61347-1:2015, 7.1 and IEC 61347-1:2015/AMD1:2017, 7.1).
- Standard57 pagesEnglish languagesale 15% off
- Standard36 pagesEnglish and French languagesale 15% off
IEC 61347-2-8:2024 specifies safety requirements for ballasts, excluding resistance types, for use on AC supplies up to 1 000 V at 50 Hz or 60 Hz, associated with fluorescent lamps with or without pre-heated cathodes operated with or without a starter or starting device and having rated powers, dimensions and characteristics as specified in IEC 60081 and IEC 60901. This second edition cancels and replaces the first edition published in 2000 and Amendment 1:2006. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) introduction of dated references where appropriate;
b) alignment of clause numbers with those of IEC 61347-1.
- Standard66 pagesEnglish languagesale 15% off
- Standard41 pagesEnglish and French languagesale 15% off
IEC 61347-2-1:2024 specifies safety requirements for starting devices (starters other than glow starters and ignitors) for fluorescent and other discharge lamps for use on AC supplies up to 1 000 V at 50 Hz or 60 Hz which produce starting pulses not greater than 100 kV and which are used in combination with lamps and controlgear covered in IEC 60081, IEC 60188, IEC 60192, IEC 60662, IEC 60901, IEC 61167, IEC 61195, IEC 61199, IEC 61347-2-8 and IEC 61347-2-9.
This second edition cancels and replaces the first edition published in 2000, Amendment 1:2005 and Amendment 2:2013. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) update of normative references, introducing dated references where appropriate;
b) clarification of sample item numbers;
c) alignment of clause numbers with those of IEC 61347-1;
d) renumbering of Clause 15 and Clause 16.
- Standard76 pagesEnglish languagesale 15% off
- Standard49 pagesEnglish and French languagesale 15% off
IEC 61347-2-3:2024 specifies safety requirements for electronic controlgear for use on AC supplies at 50 Hz or 60 Hz up to 1 000 V or on DC supplies up to 1 000 V with lamp operating frequencies deviating from the supply frequency, associated with fluorescent lamps as specified in IEC 60081 and IEC 60901, low-pressure UV lamps, and other fluorescent lamps for high-frequency operation. This third edition cancels and replaces the second edition published in 2011 and Amendment 1:2016. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) introduction of dated references where appropriate;
b) clarification of sample item numbers;
c) alignment of clause numbers with those of IEC 61347-1.
- Standard115 pagesEnglish languagesale 15% off
- Standard72 pagesEnglish and French languagesale 15% off
IEC 61347-2-10:2024 specifies safety requirements for electronic controlgear for high-frequency operation of tubular cold-cathode discharge lamps used in signs and luminous discharge tube installations and operating with an output voltage exceeding 1 000 V but not exceeding 10 000 V for direct connection to DC or AC supply voltages not exceeding 1 000 V (at 50 Hz or 60 Hz in case of alternating current). This second edition cancels and replaces the first edition published in 2000 and Amendment 1:2008. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) introduction of dated references as appropriate;
b) clarification of sample item numbers.
- Standard74 pagesEnglish languagesale 15% off
- Standard46 pagesEnglish and French languagesale 15% off
IEC 62386-303:2017 specifies a bus system for control by digital signals of electronic lighting equipment which is in line with the requirements of IEC 61347, with the addition of DC supplies.
This document is only applicable to IEC 62386-103:2014 and IEC 62386-103:2014/AMD1:— input devices that deliver occupancy information to the lighting control system through movement or presence sensing.
- Standard28 pagesEnglish languagesale 15% off
- Standard44 pagesEnglish and French languagesale 15% off
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.