IEC 60840:2020/COR1:2021
(Corrigendum)Corrigendum 1 - Power cables with extruded insulation and their accessories for rated voltages above 30 kV (Um = 36 kV) up to 150 kV (Um = 170 kV) - Test methods and requirements
Corrigendum 1 - Power cables with extruded insulation and their accessories for rated voltages above 30 kV (U<sub>m </sub>= 36 kV) up to 150 kV (U<sub>m</sub> = 170 kV) - Test methods and requirements
Corrigendum 1 - Câbles d'énergie à isolation extrudée et leurs accessoires pour des tensions assignées supérieures à 30 kV (U<sub>m</sub> = 36 kV) et jusqu'à 150 kV (U<sub>m</sub> = 170 kV) - Méthodes et exigences d'essai
General Information
Relations
Buy Standard
Standards Content (Sample)
IEC 2021
INTERNATIONAL ELECTROTECHNICAL COMMISSION
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE
____________
IEC 60840 IEC 60840
Edition 5.0 2020-05 Édition 5.0 2020-05
POWER CABLES WITH EXTRUDED INSULATION CÂBLES D'ÉNERGIE À ISOLATION EXTRUDÉE
AND THEIR ACCESSORIES FOR RATED ET LEURS ACCESSOIRES POUR DES TENSIONS
VOLTAGES ABOVE 30 kV (U = 36 kV) UP TO ASSIGNÉES SUPÉRIEURES À 30 kV (U = 36 kV)
m m
150 kV (U = 170 kV) – ET JUSQU'À 150 kV (U = 170 kV) –
m m
TEST METHODS AND REQUIREMENTS MÉTHODES ET EXIGENCES D'ESSAI
CO RRI G E NDUM 1
Corrections to the French version appear after the English text.
Les corrections à la version française sont données après le texte anglais.
CONTENTS
Replace the reference to Annex K and Clauses K.1 and K.2 with the following:
Annex K (xxx) Void
2 Normative references
Replace the reference to IEC 61034-2 with the following:
IEC 61034-2:2005, Measurement of smoke density of cables burning under defined conditions
–Part 2: Test procedure and requirements
IEC 61034-2:2005/AMD1:2013
12.5.14.4 Measurement of smoke density of cables under defined conditions
Replace, in the first paragraph, "IEC 61034-2" with "IEC 61034-2:2005 and
IEC 61034-2:2005/AMD1:2013".
12.5.14.6 Determination of acidity (by pH measurement) and conductivity of gases
evolved during combustion of the non-metallic materials in the cable
Delete, in the third paragraph, the text "(determined in accordance with Annex K)".
Table 9
In the first column, sixth row "Smoke density test on cables (complete cables)", replace
"(IEC 61034-2)" with "(IEC
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.