Abstract

This standard will provide for measurement of the response of hearing protection devices in high levels of impulse noise. The purpose is to provide a method to aid in the prediction of noise exposures under the hearing protection device in the presence of impulse noise.

Status
Not Published
Technical Committee
ISO/TC 43/SC 1 - Noise
Current Stage
5020 - Proof sent to secretariat or FDIS ballot initiated: 8 weeks - 50 Approval
Start Date
17-Nov-2026
Due Date
17-Nov-2026
Completion Date
17-Nov-2026

Buy Documents

Draft

ISO/FDIS 4869-7 - Acoustics — Hearing protectors — Part 7: Method to measure the response of hearing protectors with high-level impulsive noise on an acoustic test fixture

Release Date:03-Nov-2026
English language (60 pages)
sale 15% off
sale 15% off
Draft

REDLINE ISO/FDIS 4869-7 - Acoustics — Hearing protectors — Part 7: Method to measure the response of hearing protectors with high-level impulsive noise on an acoustic test fixture

Release Date:03-Nov-2026
English language (60 pages)
sale 15% off
sale 15% off

ISO/FDIS 4869-7 is an ISO document for measuring how hearing protection devices (HPD) respond to high-level impulsive noise on an acoustic test fixture (ATF). It specifies an objective laboratory method that compares open-ear and protected measurements to derive impulsive insertion loss, impulsive level-dependent attenuation, impulsive A-weighted level attenuation, and impulsive peak-level attenuation. The method is aimed at engineers and laboratories that need to estimate the sound exposure that remains under a hearing protector when impulse noise is present.

What does ISO/FDIS 4869-7 specify?

ISO/FDIS 4869-7 specifies a test method for hearing protection devices exposed to impulsive noise, using an ATF with two ear simulators. The document covers peak sound pressure levels in the impulse range used for worn protectors, and it uses objective electroacoustic measurements rather than subjective listener tests.

The document is organized into seven clauses plus five annexes. Clauses 1 to 4 define the scope, references, terms, and where the method applies. Clauses 5 to 7 cover samples, test equipment, procedures, data reduction, uncertainty, and reporting.

AnnexWhat it covers
Annex ANormative procedure for measuring the band force of banded earplug devices
Annex BInformative background on ATF requirements and examples
Annex CInformative ways to generate impulsive noise for the test
Annex DInformative adaptation of the method to measured impulsive waveforms
Annex EInformative Python code and examples for the calculations

What are the key requirements of ISO/FDIS 4869-7?

ISO/FDIS 4869-7 sets out a controlled impulse-response test sequence, then turns the measured data into frequency-dependent and single-number protection values. In practice, the document is as much about consistent fixture setup and data handling as it is about the final attenuation numbers.

Samples, conditioning, fitting, and band force

  • Clause 5.1 requires at least five HPD samples, each with a unique identifier. For a buyer or test lab, that means results are based on more than one unit, not a single specimen.
  • Clause 5.2 requires indoor conditioning for at least 24 hours at controlled temperature and humidity, or recording ambient conditions if testing is uncontrolled. This matters because fit and seal can change with environment.
  • Clause 5.3 allows laboratory modification of HPDs that have deliberate sound transmission paths so that REAT data can be taken with those paths blocked, disabled, or occluded. The report must document the modification, including photos, materials, and mass change.
  • Clause 5.4 fixes how earmuffs, earplugs, helmet-mounted devices, and other forms are fitted to the ATF. The key practical point is that fit timing and fit instructions are part of the test result, not just product handling.
  • Clause 5.5 sets adjustable-band devices to the midpoint of their range unless the requester specifies otherwise.
  • Clause 5.6 requires band force measurement for earmuffs, banded earplugs, and helmet-mounted protectors, with the measurement conditions and device noted in the report. This matters because clamping force strongly affects seal and attenuation.

Instrumentation and impulse source

  • Clause 6 requires the ATF, RPM, microphones, calibrators, filters, and data-acquisition system to meet specified electroacoustic and calibration expectations.
  • Clause 6.2 requires impulsive noise sources that can produce nominal peak levels in three ranges: 132 dB, 150 dB, and 168 dB. The impulse must rise quickly and have a short A-duration.
  • Clause 6.3 sets the data-acquisition needs for sampling, anti-aliasing, recording duration, signal-to-noise ratio, and peak handling. In practice, the test must capture the full impulse without clipping or losing low-frequency detail.
  • Clause 6.4 defines the reference point microphone (RPM) arrangement, including a free-field pressure probe option.
  • Clauses 6.5 and 6.6 require the environmental conditions and the relative placement of ATF, RPM, and source to be controlled and verified.

Measurement sequence and calculation

  • Clause 7.3 requires simultaneous recording of the RPM and both ATF ear signals, first open-ear and then closed-ear, repeated at the three peak-level ranges. The ATF and RPM must not be moved during the sequence, and the test is repeated if temperature changes too much.
  • Clause 7.4 windows the waveforms, computes one-third octave spectra from 20 Hz to 20 kHz, and calculates impulsive insertion loss. The open-ear response is built from calibration impulses through the free-field to open-ear transfer function.
  • Clause 7.5 combines the measured impulsive insertion loss with REAT data to obtain impulsive level-dependent attenuation, then derives the single-number metrics impulsive A-weighted level attenuation and impulsive peak-level attenuation. These metrics are calculated from a Friedlander waveform by default, but the method can also be used with other impulsive waveforms.
  • Clause 7.6 estimates expanded uncertainty with a bootstrap method, at both the mean and APV settings. For a user, this means the reported protection values are accompanied by an uncertainty estimate based on the observed spread in the underlying data.
  • Clause 7.7 defines the test report content, including the device identity, fitting instructions, environment, individual ILimp responses, S/N results, Aild values, REAT data, modifications, final metrics, uncertainty, ATF details, and band force results.

What terms does ISO/FDIS 4869-7 define?

ISO/FDIS 4869-7 defines the key measurement objects and the protection metrics used throughout the method. These terms are central because the calculations combine fixture measurements, human-ear attenuation data, and impulse-specific metrics.

  • Acoustic test fixture (ATF) - An inanimate head-and-ear fixture used to measure HPD insertion loss under controlled conditions.
  • Hearing protection device (HPD) - A device worn to reduce sound pressure level in the ear canal.
  • Real ear attenuation at threshold (REAT) - The difference between hearing thresholds with and without the HPD in place, measured on human subjects.
  • Impulsive insertion loss (ILimp) - The frequency-dependent insertion loss measured with impulsive noise at a given sound level.
  • Impulsive level-dependent attenuation (Aild) - The bounded attenuation used to represent the HPD’s protective effect at a given impulsive level.
  • Impulsive A-weighted level attenuation (Aial) - The reduction in A-weighted impulsive level used for exposure estimation.
  • Impulsive peak-level attenuation (Aipl) - The reduction in peak impulsive sound pressure level predicted for the protected ear.
  • Banded earplug - Earplugs linked by a headband, which may require band-force measurement to confirm fit and seal.

Who uses ISO/FDIS 4869-7?

ISO/FDIS 4869-7 is used by hearing-protector manufacturers, independent test laboratories, and acoustics engineers who need objective impulse-noise data for earmuffs, earplugs, banded earplugs, helmet-mounted devices, and active noise reduction (ANR) HPD. It is also used by requesters who submit products and fitting instructions for evaluation.

Typical tasks include:

  • checking whether a product’s protection changes with impulse peak level
  • comparing open-ear and protected measurements on an ATF
  • documenting fit instructions and sample preparation for a test report
  • estimating protected exposure levels for impulse-noise environments such as firearms, construction, mining, and forging
  • evaluating how deliberate passive or active transmission paths affect performance

Which standards are used with ISO/FDIS 4869-7?

ISO/FDIS 4869-7 relies on several measurement and terminology standards for the fixture, microphones, filters, and uncertainty treatment.

StandardWhat it contributes
ISO/IEC Guide 98-3Framework for expanded uncertainty and coverage at 95 %
ISO 4869-1:2018REAT method used as the human-subject attenuation reference
ISO 11904-2:2021Manikin-based transfer-function reference used in the open-ear transfer discussion
ISO 48-4:2018Hardness method relevant to fixture materials and simulated flesh assessment
IEC 60050-801 and amendmentsAcoustics and electroacoustics terminology
IEC 60318-4:2010Occluded-ear simulator reference
IEC 60318-7:2022Head-and-torso simulator reference
IEC 60942:2017Sound calibrators
IEC 61094-4:1995Working standard microphones
IEC 61260-1:2014Octave-band and fractional-octave-band filters
IEC 61672-1:2013Sound level meters and frequency weighting reference
ISO 4869-2:2018Cited for the analogous single-number rating concept
ISO 4869-3:2007Cited as a related ATF insertion-loss method for earmuff-type protectors

What does the ISO/FDIS 4869-7 document contain?

ISO/FDIS 4869-7 contains a full laboratory workflow from setup to reporting. It includes requirements for the ATF, the impulse source, the RPM arrangement, sample fitting, band-force measurement, waveform acquisition, one-third octave processing, and uncertainty estimation.

The document also includes the calculation steps for ILimp, Aild, Aial, and Aipl, with flow-oriented descriptions in Clause 7. It adds practical support material in the annexes, including a normative band-force procedure, guidance on ATF design, examples of impulse generation, adaptation to measured impulses, and Python code that implements the calculations and shows example use.

Buy Documents

Draft

ISO/FDIS 4869-7 - Acoustics — Hearing protectors — Part 7: Method to measure the response of hearing protectors with high-level impulsive noise on an acoustic test fixture

Release Date:03-Nov-2026
English language (60 pages)
sale 15% off
sale 15% off
Draft

REDLINE ISO/FDIS 4869-7 - Acoustics — Hearing protectors — Part 7: Method to measure the response of hearing protectors with high-level impulsive noise on an acoustic test fixture

Release Date:03-Nov-2026
English language (60 pages)
sale 15% off
sale 15% off

Get Certified

Connect with accredited certification bodies for this standard

CIS Institut d.o.o.

Personal Protective Equipment (PPE) certification body. Notified Body NB-2890 for EU Regulation 2016/425 PPE.

SA Slovenia Verified

Kiwa BDA Testing

Building and construction product certification.

RVA Netherlands Verified

Kmetijski inštitut Slovenije

Agricultural Institute of Slovenia. Soil testing, plant health, agricultural product analysis.

SA Slovenia Verified

Sponsored listings

Frequently Asked Questions

ISO/FDIS 4869-7 is a draft published by the International Organization for Standardization (ISO). Its full title is "Acoustics — Hearing protectors — Part 7: Method to measure the response of hearing protectors with high-level impulsive noise on an acoustic test fixture". This standard covers: This standard will provide for measurement of the response of hearing protection devices in high levels of impulse noise. The purpose is to provide a method to aid in the prediction of noise exposures under the hearing protection device in the presence of impulse noise.

This standard will provide for measurement of the response of hearing protection devices in high levels of impulse noise. The purpose is to provide a method to aid in the prediction of noise exposures under the hearing protection device in the presence of impulse noise.

ISO/FDIS 4869-7 is classified under the following ICS (International Classification for Standards) categories: 13.340.20 - Head protective equipment. The ICS classification helps identify the subject area and facilitates finding related standards.

ISO/FDIS 4869-7 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 3.1 A-duration
  • 3.2 acoustic test fixture
  • 3.3 active insertion loss
  • 3.4 active noise reduction hearing protection device
  • 3.5 assumed protection value
  • 3.6 attenuation
  • 3.7 banded earplug
  • 3.8 bitragion width
  • 3.9 head height
  • 3.10 bone conduction (including soft tissue conduction)
  • 3.11 ear canal entrance point
  • 3.12 earmuff
  • 3.13 earplug
  • 3.14 free-field to open-ear transfer function
  • 3.15 Friedlander waveform
  • 3.16 hearing protection device
  • 3.17 impulsive level-dependent gain
  • 3.18 equivalent impulsive A-weighted sound pressure level
  • 3.19 impulsive A-weighted level attenuation
  • 3.20 impulsive insertion loss
  • 3.21 impulsive level-dependent attenuation
  • 3.22 impulsive peak-level attenuation
  • 3.23 impulse noise
  • 3.24 impulsive noise
  • 3.25 insertion loss
  • 3.26 noise reduction
  • 3.27 passive hearing protection device
  • 3.28 real ear attenuation at threshold
  • 3.29 reference point
  • 3.30 reference point microphone
  • 3.31 requester
  • 3.32 signal-to-noise-and-distortion ratio
  • 3.33 signal-to-noise ratio
  • 3.34 transfer function of the open ear
  • 4 Applicability of the test methods
  • 5 Requirements for product samples and band force
  • 5.1 Required number of HPD samples
  • 5.2 Conditioning of HPD samples
  • 5.3 Modification of HPD samples
  • 5.4 Fitting of HPDs to the ATF
  • 5.5 Devices with adjustable band force
  • 5.6 Measurement of band force
  • 6 Instrumentation and facilities requirements
  • 6.1 Acoustic test fixture
  • 6.2 Impulsive noise source
  • 6.3 Data acquisition system
  • 6.4 Reference point microphone (RPM)
  • 6.5 Environmental conditions
  • 6.6 Positioning of the ATF and RPM
  • 1 Acoustic test fixture (ATF)
  • 2 Reference point microphone (RPM)
  • 3 Impulsive noise source
  • 4 Sensor element of RPM
  • 7 Test procedures and data reduction
  • 7.1 Overview
  • 7.2 Notation
  • 7.3 Measurement of time waveforms
  • 7.4 Computation of the and
  • 7.5 Calculation of the single-number metrics
  • 7.6 Uncertainty for single number metrics
  • 7.7 Information to be included in the test report
  • Annex A
  • Annex B
  • Annex C
  • Annex D
  • Annex E
  • Bibliography

Introduction

This document describes methods for making measurements and characterizing the impulsive noise performance of a hearing protection device (HPD, either earmuff or earplug) on an acoustic test fixture (ATF). This is done at several different impulsive peak levels to characterize any non-linearity in the performance of the HPD under test. A noise reduction procedure is used in which the ATF ear simulator outputs and the output of a microphone at a reference free-field position are simultaneously sampled. Initially, measurements are made with the ATF ears unoccluded; a free-field to open-ear transfer function is calculated from this data. Then simultaneous measurements of the ATF ears occluded by the HPD and the reference point microphone are made and this data, along with the , are used to calculate a one-third octave band impulsive insertion loss at each peak level measured. Impulsive noise can be produced in a variety of occupational and recreational settings – most notably when discharging firearms, but also in construction, mining, and forging operations. To estimate the protection the HPD provides on human users, a calculation is defined that bounds the on the ATF at each peak level by the real-ear attenuation at threshold of the HPD, measured with any deliberate passive or active sound transmission pathways in the device turned off or disabled. The result is the one-third octave band impulsive level-dependent attenuation . Finally, two single-number metrics of impulsive performance calculated from the are then defined: the impulsive peak-level attenuation and the impulsive A-weighted level attenuation . The method can also be applied to estimate the peak and spectral level attenuation with other impulsive waveforms.

FINAL DRAFT International Standard ISO/FDIS 4869-7:2026(en) Acoustics — Hearing protectors — Part 7:

Method to measure the response of hearing protectors with high-level impulsive noise on an acoustic test fixture

1 Scope

This document specify methods for the measurement of the insertion loss of hearing protection devices at supra-threshold levels of impulsive noise using an acoustical test fixture (ATF). The ATF is an anthropometric fixture and contains two ear simulators for the purpose of testing hearing protection devices. This document establishes uniform instrumentation, calibration and electroacoustic requirements including details regarding the sound field of test facilities, and the acoustical characteristics of ATFs. The procedures described utilize signals at sound levels representative of applications in which hearing protection devices are worn (peak sound pressure levels ranging from 130 dB to 170 dB). These procedures are intended to provide quick, economical, and repeatable objective (not psychophysical) measurement techniques that can serve as additions to or complements of the real-ear attenuation at threshold (REAT) [1] method specified in ISO 4869-1 . Methods for estimating attenuation values are provided, combining the measured insertion loss with real-ear attenuation measurements of the device with deliberately designed active or passive sound transmission mechanisms occluded or disabled, resulting in the impulsive leveldependent attenuation . Other metrics are defined (the impulsive A-weighted level attenuation and impulsive peak-level attenuation ; these are intended for use in estimating effective sound pressure levels (SPLs) when hearing protectors are worn.

2 Normative references

The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 48-4, Rubber, vulcanized or thermoplastic — Determination of hardness — Part 4: Indentation hardness by durometer method (Shore hardness) ISO/IEC Guide 98-3, Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in me a s ur ement (GUM: 1995) ISO 4869-1:2018, Acoustics — Hearing protectors — Part 1: Subjective method for the measurement of sound attenuation ISO 4869-1, Acoustics — Hearing protectors — Part 1: Subjective method for the measurement of sound attenuation IEC 60050-801, International Electrotechnical Vocabulary (IEV) - Part 801: Acoustics and electroacoustics IEC 60318-4, Electroacoustics - Simulators of human head and ear - Part 4: Occluded-ear simulator for the measurement of earphones coupled to the ear by means of ear inserts IEC 60942, Electroacoustics - Sound calibrators IEC 61094-4:1995, Measurement microphones - Part 4: Specifications for working standard microphones IEC 61260-1:2014, Electroacoustics - Octave-band and fractional-octave-band filters - Part 1: Specifications

ISO/FDIS 4869-7:2026(en)

3 Terms and definitions

For the purposes of this document, the terms and definitions given in IEC 60050-801 and the following apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:

  • ISO Online browsing platform: available at https:// www .iso .org/ obp
  • IEC Electropedia: available at https:// www .electropedia .org/

3.1 A-duration

duration of an impulsive sound from the time of its initial rapid increase in positive sound pressure to the time when the sound pressure first becomes negative

3.2 acoustic test fixture

ATF inanimate device that approximates certain physical characteristics including dimensions of a representative human head, pinnae, and ear canals and is used for measuring the insertion loss (3.25) of a hearing protection device (3.16) Note 1 to entry: Because this document is for measuring earplugs in addition to earmuffs, this definition of acoustic [2] test fixture (3.2) is more comprehensive than the specification given in ISO 4869-3 .

3.3 active insertion loss

frequency-dependent insertion loss (3.25) of an active noise reduction hearing protection device (3.4), determined from the difference between the sound pressure levels measured with and without the device’s active noise cancellation functionality operating, measured during a single fitting on an acoustic test fixture (3.2)

3.4 active noise reduction hearing protection device

ANR HPD hearing protection device (3.16) that reduces acoustic energy by actively generating a sound wave that produces destructive interference with the noise under the hearing protection device (3.16), thereby attenuating the noise

3.5 assumed protection value

APV protection computed as the mean attenuation (3.6) minus the product of the standard deviation and a constant, α Note 1 to entry: By default, a value of one is used for α; increasing α will increase the share of the population exceeding the APV (3.5).

3.6 attenuation

reduction of sound pressure level by a hearing protection device (3.16) using a combination of structural elements, acoustic pathways, electronic means either mechanical means, or both, as determined by subjects listening to test signals Note 1 to entry: Insertion losses do not capture every pathway to the cochlea, but attenuation (3.6) can be estimated from insertion loss (3.25) by appropriately bounding with real-ear attenuation measurements that characterize such pathways.

ISO/FDIS 4869-7:2026(en)

3.7 banded earplug

earplugs linked by a headband (also called canal cap, concha-seated or semi-insert hearing protector) Note 1 to entry: Banded earplugs that cap the canal can require the force of the band to retain their position and acoustic seal.

3.8 bitragion width

horizontal distance between the left tragion and the right tragion

3.9 head height

vertical distance from the top point of the head to the tragion

3.10 bone conduction (including soft tissue conduction)

transmission of acoustic energy to the cochlea (inner ear), resulting from vibration of the bones and soft tissues of the head and ear canal

3.11 ear canal entrance point

EEP centre point of the ear canal opening on a person or on an acoustic test fixture (3.2)

3.12 earmuff

hearing protection device (3.16) usually comprised of a headband and earcups with a soft cushion to seal against the head, intended to fit against the pinna (supra-aural) or the sides of the head enclosing the pinna (circumaural) Note 1 to entry: The earcups can also be held in position by attachment arms that are mounted on an industrial safety helmet, hard hat or hard cap.

3.13 earplug

hearing protection device (3.16) that is inserted into or that caps the ear canal

3.14 free-field to open-ear transfer function

frequency-dependent difference between the sound pressure levels at the open ATF (3.2) ear and at a freefield reference point microphone (3.30) in response to an impulsive noise (3.24)

3.15 Friedlander waveform

idealized time domain blast wave pressure signal of an explosion

3.16 hearing protection device

HPD device, also called a hearing protector, worn to reduce the sound pressure level in the ear canal

3.17 impulsive level-dependent gain

discrete Fourier transform transfer function computed from the impulsive level-dependent attenuation (3.21) and used to estimate the closed-ear peak pressure for any given impulsive noise, as required to calculate the impulsive peak-level attenuation (3.22)

ISO/FDIS 4869-7:2026(en)

3.18 equivalent impulsive A-weighted sound pressure level

A-weighted sound pressure level of an impulsive noise (3.24)/impulse noise (3.23), integrated over the duration of the impulsive noise (3.24) recording, then normalized to a 100 ms interval

3.19 impulsive A-weighted level attenuation

reduction of the equivalent impulsive A-weighted sound pressure level (3.18) for an impulsive noise (3.24), calculated from the

3.20 impulsive insertion loss

frequency-dependent insertion loss (3.25) measured using an impulsive noise (3.24) source at a given sound pressure level, determined from the difference between the sound pressure levels with the HPD (3.16) in place on the fixture and the sound pressure levels estimated from those measured at a free-field probe after adjusting by the

3.21 impulsive level-dependent attenuation

frequency-dependent reduction of noise resulting from an HPD (3.16) ’s presence over or in a real ear, computed by bounding the by the of the HPD (3.16) with deliberately designed electronic either mechanical sound transmission paths, or both, disabled

3.22 impulsive peak-level attenuation

reduction of the peak sound pressure level of an impulsive noise (3.24) provided by an HPD (3.16) calculated from the and assuming the use of a standardized free-field to open-ear transfer function (3.14)

3.23 impulse noise

acoustic event due to the rapid expansion of gases, characterized by a rise time of less than 1 ms and a duration of less than 1 s

3.24 impulsive noise

single burst or a series of short bursts of sound, typically less than 1 s in duration, produced by rapid expansion of gases (impulse) or a collision of two or more solids (impact) Note 1 to entry: The pressure-time history of a single burst includes a rise to a peak pressure, followed by a decay of the pressure envelope.

3.25 insertion loss

level difference in decibels between the sound pressure levels measured at a fixed position in the ear, measured under two different conditions (e.g. with and without the HPD (3.16) in place or with active noise reduction (3.26) (ANR) on and off in a single fitting)

3.26 noise reduction

level difference in decibels between sound pressure levels measured simultaneously external to and under the hearing protector

ISO/FDIS 4869-7:2026(en)

3.27 passive hearing protection device

device that relies solely on mechanical elements to block or otherwise control the transmission of sound to the auditory system

3.28 real ear attenuation at threshold

REAT difference between the threshold of hearing with (occluded) and without (unoccluded) the hearing protector in place under otherwise identical test conditions measured for a set of human subjects at specified frequencies

3.29 reference point

location in the sound field used to determine the nominal peak pressure level and to provide the reference signal used when calculating ATF (3.2) open-ear waveforms

3.30 reference point microphone

RPM microphone located at the reference point (3.29) Note 1 to entry: The microphone can be mounted in a pressure probe body designed for measuring impulsive noise (3.24) sources.

3.31 requester

party submitting a hearing protection device (3.16) and fitting instructions for testing Note 1 to entry: When the investigator is evaluating hearing protectors other than for an entity external to the laboratory, the requester (3.31) is considered to be the investigator conducting the research.

3.32 signal-to-noise-and-distortion ratio

SINAD level, in decibels, of the ratio of the root-mean-square (rms) amplitude of the analogue-to-digital converter output signal for a full unclipped input signal to the rms amplitude of the output noise, where noise is defined to include not only random errors but also non-linear distortion and the effects of sampling time errors

3.33 signal-to-noise ratio

S/N ratio of the spectrum level of the measurement microphone signal during the impulse to the spectrum level without the impulse but with typical background noise from the ambient environment and equipment operating in the vicinity of the test Note 1 to entry: This document uses S/N for signal-to-noise ratio (3.33) in order to reduce the potential confusion with [3] Single Number Rating, SNR, from ISO 4869-2 .

3.34 transfer function of the open ear

TFOE ratio of the spectrum at the eardrum reference point (3.29) to the spectrum at the head reference point (3.29) with the head removed

ISO/FDIS 4869-7:2026(en)

4 Applicability of the test methods

The measurements obtained using this document are applicable for peak sound pressure levels ranging from 130 dB to 170 dB. These methods may be adapted to levels exceeding 170 dB as long as attention is paid to clipping and distortion limits of the instrumentation, beyond the requirements defined.

5 Requirements for product samples and band force

5.1 Required number of HPD samples

A minimum of five samples of the HPD under evaluation shall be used in each test. When the HPDs are supplied in multiple eartip sizes or cushions, an appropriate size that best fits the ATF providing a good seal shall be used. Each sample shall be marked with a unique identifier to be associated with all measurements made on that sample. For earplugs, a sample consists of a pair of earplugs. For other HPDs, a sample is one pair of earmuffs, one banded earplug or one helmet-mounted HPD.

5.2 Conditioning of HPD samples

For HPD samples tested indoors, the samples shall be stored in a controlled environment for at least 24 h before testing. The environment shall be maintained at a temperature of (22 ± 5) °C and relative humidity not to exceed 85 %. For samples tested in an uncontrolled environment, the temperature and humidity shall be recorded as indicated in 6.5.1 and 6.5.2.

5.3 Modification of HPD samples

For impulsive noise testing of HPDs that include deliberately designed sound transmission pathways (such as acoustical filters or pressure-equalization pathways that bypass the fundamental sealing capabilities of the device, see 7.1) but which do not include user-operable means to disable these pathways, then additional samples modified to block these pathways shall be tested to obtain the REAT data needed as part of the calculation of the . These additional HPD samples shall be modified by the laboratory to block these sound transmission pathways in a manner that, in the experimenter’s best judgement, disables the pathways while minimally altering the fundamental attenuation capabilities of the device (e.g. do not add excessive mass). Either the requester or experimenter may identify the need for such modifications, and the decision to modify or not shall be justified in the test report. The requester may also suggest ways to disable such pathways to the experimenter and review the modifications to be done, but it is at the experimenter’s discretion as to what modifications to make. Furthermore, the test report shall document the modifications done, including photographs of the modified product, details on materials used and mass changes. NOTE A manufacturer can provide a recommended procedure to occlude the acoustic filter of an HPD. If the HPD to be tested on an ATF has features meant to improve fit and seal to real ears which degrade fit and seal on the ATF, parts can be replaced by the manufacturer with alternatives meant to comparably fit the ATF. An example is a circumaural muff whose ear seals include a bump to fill the depression below the ear adjacent to the gonion which would create a leak when sealing to an ATF with a flat plane surrounding the pinna. Any such swapped parts shall be fabricated to be otherwise similar to the parts meant for use on human subjects, the experimenter shall inspect the parts to determine whether the similarity is satisfactory, and any replacement parts shall be noted in the test report.

5.4 Fitting of HPDs to the ATF

When fitting earmuffs to the ATF in the over-the-head position, the headband shall be adjusted to contact the surface of the ATF anywhere along the coronal arc, once the cups have been properly positioned to symmetrically sit on the fixture and around the pinnae. For devices with headbands that do not maintain their size adjustment when removed from the fixture, the adjustable headband shall be extended to its largest size before every fit. The fitting procedure is completed by pressing the cups firmly against the fixture.

NOTE After the initial fitting, the headband can be marked to guide the position for future fittings.

ISO/FDIS 4869-7:2026(en) Measured insertion loss can vary with the firmness with which some HPDs are mounted on the ATF. When mounting a device with a headband, the headband shall be contracted so that only a light force is used to make contact with the top of the acoustic test fixture. A higher level of force at that point can result in an uneven application of force against the sides of the fixture for some HPDs (e.g. a much larger proportion of the force can be present at the top than at the bottom of the earcup). When conducting ATF tests of earplugs, the depth of insertion and quality of the seal attained shall be based on fitting instructions provided by the requester.

Helmet systems, HPDs with back-of-the-neck suspension systems, and devices that do not have rigid headband springs (including earplugs) shall be positioned on the test fixture in accordance with requester’s instructions.

To allow hearing protectors to conform to the circumaural regions or expand to fit the ear canal, insertion loss measurements shall begin a minimum of 30 s after the hearing protectors have been fitted, unless the requester’s written instructions specify that a longer minimum time is required. If so, the waiting time observed shall be documented in the test report.

5.5 Devices with adjustable band force

Unless otherwise designated by the requester, devices that include adjustment mechanisms that allow the band force to be varied shall be set to the visually determined midpoint of their adjustment range. This setting shall be used when measuring the insertion loss on the ATF.

...

Contents

  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 3.1 A-duration, noun
  • 3.2 acoustic test fixture, noun
  • 3.3 active insertion loss, noun
  • 3.4 active noise reduction hearing protection device, noun
  • 3.5 assumed protection value, noun
  • 3.6 attenuation, noun
  • 3.7 banded earplug, noun
  • 3.8 bitragion width, noun
  • 3.9 head height, noun
  • 3.10 bone conduction (including soft tissue conduction), noun)
  • 3.11 ear canal entrance point
  • 3.12 earmuff, noun
  • 3.13 earplug, noun
  • 3.14 free-field to open-ear transfer function, noun
  • 3.15 Friedlander waveform, noun
  • 3.16 hearing protection device, noun
  • 3.17 impulsive level-dependent gain, noun
  • 3.18 equivalent impulsive A-weighted sound pressure level, noun
  • 3.19 impulsive A-weighted level attenuation, noun
  • 3.20 impulsive insertion loss, noun
  • 3.21 impulsive level-dependent attenuation, noun
  • 3.22 impulsive peak-level attenuation, noun
  • 3.23 impulse noise, noun
  • 3.24 impulsive noise, noun
  • 3.25 insertion loss, noun
  • 3.26 noise reduction, noun
  • 3.27 passive hearing protection device, noun
  • 3.28 real ear attenuation at threshold, noun
  • 3.29 reference point, noun
  • 3.30 reference point microphone, noun
  • 3.31 requester, noun
  • 3.32 signal-to-noise-and-distortion ratio, noun
  • 3.33 signal-to-noise ratio
  • 3.34 transfer function of the open ear, noun
  • 4 Applicability of the test methods
  • 5 Requirements for product samples and band force
  • 5.1 Required number of HPD samples
  • 5.2 Conditioning of HPD samples
  • 5.3 Modification of HPD samples
  • 5.4 Fitting of HPDs to the ATF
  • 5.5 Devices with adjustable band force
  • 5.6 Measurement of band force
  • 6 Instrumentation and facilities requirements
  • 6.1 Acoustic test fixture
  • 6.2 Impulsive noise source
  • 6.3 Data acquisition system
  • 6.4 Reference point microphone (RPM)
  • 6.5 Environmental conditions
  • 6.6 Positioning of the ATF and RPM
  • 1 Acoustic Test Fixturetest fixture (ATF)
  • 2 Reference Point Microphonepoint microphone (RPM)
  • 3 Impulsive Noise Sourcenoise source
  • 4 Sensor element of RPM
  • 7 Test procedures and data reduction
  • 7.1 Overview
  • 7.2 Notation
  • 7.3 Measurement of time waveforms
  • 7.4 Computation of the 𝑰𝑰𝑰𝑰 𝑰𝑰𝑰𝑰 and 𝑨𝑨 𝑨𝑨
  • 7.5 Calculation of the Single-Number Metricssingle-number metrics
  • 7.6 Uncertainty for single number metrics
  • 7.7 Information to be included in the test report
  • Annex A
  • 1 Antianti-helix
  • 2 Helixhelix
  • 3 Conchaconcha
  • 4 Earear canal entrance point (EEP)
  • 5 Tragiontragion
  • 6 Cruscrus of helix
  • 7 Earear length
  • 8 Earear breadth
  • 9 Conchaconcha length
  • 10 Conchaconcha breadth (EEP to anti-helix)
  • 11 Conchaconcha breadth (Tragion to anti-helix)
  • 12 Earlengthearlength above EEP
  • 13 Conchaconcha length below EEP
  • 14 Verticalvertical tilt angle

Introduction

This document specifiesdescribes methods for making measurements and characterizing the impulsive noise performance of a hearing protection device (HPD, either earmuff or earplug) on an acoustic test fixture (ATF). This is done at several different impulsive peak levels to characterize any nonlinearitynon-linearity in the performance of the HPD under test. A noise reduction procedure is used in which the ATF ear simulator outputs and the output of a microphone at a reference free-field position are simultaneously sampled. Initially, measurements are made with the ATF ears unoccluded; a free-field to open-ear transfer function 𝐻𝐻 is FF calculated from this data. Then simultaneous measurements of the ATF ears occluded by the HPD and the reference point microphone are made and this data, along with the 𝐻𝐻 , are used to calculate a one-third octave FF band impulsive insertion loss �𝐼𝐼𝐿𝐿 � at each peak level measured. Impulsive noise can be produced in a imp variety of occupational and recreational settings – most notably when discharging firearms, but also in construction, mining, and forging operations. To estimate the protection the HPD provides on human users, a calculation is defined that bounds the 𝐼𝐼𝐿𝐿 on the ATF at each peak level by the real-ear attenuation at imp threshold (𝐴𝐴 )of the HPD, measured with any deliberate passive or active sound transmission pathways in REAT the device turned off or disabled. The result is the one-third octave band impulsive level-dependent

attenuation 𝐴𝐴 . Finally, two single-number metrics of impulsive performance calculated from the 𝐴𝐴 are ILD ILD then defined: the impulsive peak-level attenuation (𝐴𝐴 ) and the impulsive A-weighted level attenuation IPL

𝐴𝐴 . The method can also be applied to estimate the peak and spectral level attenuation with other IAL impulsive waveforms.

ISO/FDIS 4869-7:2026(en) Acoustics — Hearing protectors — Part 7:

Method to measure the response of hearing protectors with high-level impulsive noise on an acoustic test fixture

1 Scope

This document describesspecify methods for the measurement of the insertion loss of hearing protection devices at supra-threshold levels of impulsive noise using an acoustical test fixture (ATF). The ATF is an anthropometric fixture and contains two ear simulators for the purpose of testing hearing protection devices. The standardThis document establishes uniform instrumentation, calibration, and electroacoustic requirements including details regarding the sound field of test facilities, and the acoustical characteristics of ATFs.

The procedures described utilize signals at sound levels representative of applications in which hearing protection devices are worn (peak sound pressure levels ranging from 130 dB to 170 dB). These procedures are intended to provide quick, economical, and repeatable objective (not psychophysical) measurement techniques that can serve as additions to or complements of the real-ear attenuation at threshold (REAT) [1] method specified in ISO 4869-1 ISO 4869-1:2018.. Methods for estimating attenuation values are provided, combining the measured insertion loss with real-ear attenuation measurements of the device with deliberately designed active or passive sound transmission mechanisms occluded or disabled, resulting in

the impulsive level-dependent attenuation 𝐴𝐴 . Other metrics are defined (the impulsive A-weighted level ILD attenuation (𝐴𝐴 ) and impulsive peak-level attenuation (𝐴𝐴 ); these are intended for use in estimating ILA IPL effective sound pressure levels (SPLs) when hearing protectors are worn.

2 Normative references

The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 48-4:2018, Rubber, vulcanized or thermoplastic — Determination of hardness — Part 4: Indentation hardness by durometer method (Shore hardness) ISO/IEC Guide 98-3:2008, Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) ISO 4869-1:2018, Acoustics — Hearing protectors — Part 1: Subjective method for the measurement of sound attenuation ISO 11904-2:20214869-1, Acoustics — DeterminationHearing protectors — Part 1: Subjective method for the measurement of sound immission from sound sources placed close to the ear — Part 2: Technique using a manikinattenuation IEC 60050-801:1994, International Electrotechnical Vocabulary (IEV) - Part 801: Acoustics and electroacoustics IEC 60050-801:1994/AMD1:2018, Amendment 1 - International Electrotechnical Vocabulary (IEV) - Part 801:

Acoustics and electroacoustics IEC 60050-801:1994/AMD2:2021, Amendment 2 - International Electrotechnical Vocabulary (IEV) - Part 801:

Acoustics and electroacoustics

ISO/FDIS 4869-7:2026(en) IEC 60050-801:1994/AMD3:2021, Amendment 3 - International Electrotechnical Vocabulary (IEV) - Part 801:

Acoustics and electroacoustics IEC 60050-801:1994/AMD4:2021, Amendment 4 - International Electrotechnical Vocabulary (IEV) - Part 801:

Acoustics and electroacoustics IEC 60318-4:2010, Electroacoustics - Simulators of human head and ear - Part 4: Occluded-ear simulator for the measurement of earphones coupled to the ear by means of ear inserts IEC 60318-7:2022, Electroacoustics - Simulators of human head and ear - Part 7: Head and torso simulator for the measurement of sound sources close to the ear IEC 60942:2017, Electroacoustics - Sound calibrators IEC 61094-4:1995, Measurement microphones - Part 4: Specifications for working standard microphones IEC 61260-1:2014, Electroacoustics - Octave-band and fractional-octave-band filters - Part 1: Specifications IEC 61672-1:2013, Electroacoustics - Sound level meters - Part 1: Specifications

3 Terms and definitions

For the purposes of this document, the terms and definitions given in IEC 60050-801:1994, IEC 60050- 801:1994/AMD1:2018 , IEC 60050-801:1994/AMD2:2021 , IEC 60050-801:1994/AMD3:2021 , and IEC 60050-801:1994/AMD4:2021 and the following apply.

ISO and IEC maintain terminology databases for use in standardization at the following addresses:

  • ISO Online browsing platform: available at https://www.iso.org/obp
  • IEC Electropedia: available at https://www.electropedia.org/

3.1 A-duration, noun

𝒕𝒕 54T, noun A duration of an impulsive sound from the time of its initial rapid increase in positive sound pressure to the time when the sound pressure first becomes negative

3.2 acoustic test fixture, noun

ATF, noun inanimate device that approximates certain physical characteristics including dimensions of a representative human head, pinnae, and ear canals and is used for measuring the insertion loss (3.25) of a hearing protection device (3.16) Note 1 to entry: Because this standarddocument is for measuring earplugs in addition to earmuffs, this definition of [12] acoustic test fixture (3.2) is more comprehensive than the specification given in ISO 4869-3:2007 . Field Code Changed

3.3 active insertion loss, noun

𝑰𝑰𝑰𝑰 54T, noun Active 𝑰𝑰𝑰𝑰 active frequency-dependent insertion loss (3.25) of an active noise reduction hearing protection device (3.4), determined from the difference between the sound pressure levels measured with and without the device’s

ISO/FDIS 4869-7:2026(en) active noise cancellation functionality operating, measured during a single fitting on an acoustic test fixture (3.2)

3.4 active noise reduction hearing protection device, noun

ANR HPD, noun hearing protection device (3.16) that reduces acoustic energy by actively generating a sound wave that produces destructive interference with the noise under the hearing protection device (3.16), thereby attenuating the noise

3.5 assumed protection value, noun

APV, noun protection computed as the mean attenuation (3.6) minus the product of the standard deviation and a constant, α Note 1 to entry: By default, a value of one is used for α; increasing α will increase the share of the population exceeding the APV (3.5) .).

3.6 attenuation, noun

reduction of sound pressure level by a hearing protection device (3.16) using a combination of structural elements, acoustic pathways, electronic means, and/or either mechanical means, or both, as determined by subjects listening to test signals Note 1 to entry: Insertion losses do not capture every pathway to the cochlea, but attenuation (3.6) can be estimated from insertion loss (3.25) by appropriately bounding with real-ear attenuation measurements that characterize such pathways.

3.7 banded earplug, noun

earplugs linked by a headband (also called canal cap, concha-seated, or semi--insert hearing protector) Note 1 to entry: Banded earplugs that cap the canal can require the force of the band to retain their position and acoustic seal.

3.8 bitragion width, noun

horizontal distance between the left tragion and the right tragion

3.9 head height, noun

vertical distance from the top point of the head to the tragion

3.10 bone conduction (including soft tissue conduction), noun)

transmission of acoustic energy to the cochlea (inner ear), resulting from vibration of the bones and soft tissues of the head and ear canal

3.11 ear canal entrance point

EEP, noun centre point of the ear canal opening on a person or on an acoustic test fixture (3.2)

ISO/FDIS 4869-7:2026(en)

3.12 earmuff, noun

hearing protection device (3.16) usually comprised of a headband and earcups with a soft cushion to seal against the head, intended to fit against the pinna (supra-aural) or the sides of the head enclosing the pinna (circumaural) Note 1 to entry: The earcups can also be held in position by attachment arms that are mounted on an industrial safety helmet, hard hat, or hard cap.

3.13 earplug, noun

hearing protection device (3.16) that is inserted into or that caps the ear canal

3.14 free-field to open-ear transfer function, noun

𝑯𝑯 54T, noun FF frequency-dependent difference between the sound pressure levels at the open ATF (3.2) ear and at a freefield reference point microphone (3.30) in response to an impulsive noise (3.24)

3.15 Friedlander waveform, noun

idealized time domain blast wave pressure signal of an explosion

3.16 hearing protection device, noun

HPD, noun device, also called a hearing protector, worn to reduce the sound pressure level in the ear canal

3.17 impulsive level-dependent gain, noun

𝑮𝑮 54T, noun 𝐈𝐈𝐈𝐈𝐈𝐈 discrete Fourier Transformtransform transfer function computed from the impulsive level-dependent attenuation (3.21)(𝐴𝐴 ) and used to estimate the closed-ear peak pressure for any given impulsive noise, as ILD required to calculate the impulsive peak-level attenuation (3.22)

3.18 equivalent impulsive A-weighted sound pressure level, noun

𝑰𝑰 54T, noun Aeq,100 ms A-weighted sound pressure level of an impulsive noise (3.24) / )/impulse noise (3.23) ,), integrated over the duration of the impulsive noise (3.24) recording, then normalized to a 100 ms interval

3.19 impulsive A-weighted level attenuation, noun

𝑨𝑨 54T, noun 𝐈𝐈𝐈𝐈L reduction of the equivalent impulsive A-weighted sound pressure level (3.18)�𝐿𝐿 � for an impulsive noise Aeq,100 ms (3.24), calculated from the 𝐴𝐴 ILD

3.20 impulsive insertion loss, noun

𝑰𝑰𝑰𝑰 54T, noun imp frequency-dependent insertion loss (3.25) measured using an impulsive noise (3.24) source at a given sound pressure level, determined from the difference between the sound pressure levels with the HPD (3.16) in place on the fixture and the sound pressure levels estimated from those measured at a free-field probe after adjusting by the 𝐻𝐻 FF

ISO/FDIS 4869-7:2026(en)

3.21 impulsive level-dependent attenuation, noun

𝑨𝑨 54T, noun ILD frequency-dependent reduction of noise resulting from an HPD (3.16) ’s presence over or in a real ear, computed by bounding the 𝐼𝐼𝐿𝐿 by the 𝐴𝐴 of the HPD (3.16) with deliberately designed electronic imp REAT and/oreither mechanical sound transmission paths, or both, disabled

3.22 impulsive peak-level attenuation, noun

𝑨𝑨 54T, noun 𝐈𝐈𝐈𝐈𝐈𝐈 reduction of the peak sound pressure level of an impulsive noise (3.24) provided by an HPD (3.16) calculated from the 𝐴𝐴 and assuming the use of a standardized free-field to open-ear transfer function (3.14) ILD

3.23 impulse noise, noun

acoustic event due to the rapid expansion of gases, characterized by a rise time of less than 1 ms and a duration of less than 1 s

3.24 impulsive noise, noun

single burst or a series of short bursts of sound, typically less than 1 s in duration, produced by rapid expansion of gases (impulse) or a collision of two or more solids (impact) Note 1 to entry: The pressure-time history of a single burst includes a rise to a peak pressure, followed by a decay of the pressure envelope.

3.25 insertion loss, noun

𝑰𝑰𝑰𝑰54T, noun level difference in decibels between the sound pressure levels measured at a fixed position in the ear, measured under two different conditions (e.g. with and without the HPD (3.16) in place or with active noise reduction (3.26) (ANR) on and off in a single fitting)

3.26 noise reduction, noun

level difference in decibels between sound pressure levels measured simultaneously external to and under the hearing protector

3.27 passive hearing protection device, noun

device that relies solely on mechanical elements to block or otherwise control the transmission of sound to the auditory system

3.28 real ear attenuation at threshold, noun

REAT, noun 𝑨𝑨 54T, noun 𝐑𝐑𝐑𝐑𝐈𝐈𝐑𝐑 difference between the threshold of hearing with (occluded) and without (unoccluded) the hearing protector in place under otherwise identical test conditions measured for a set of human subjects at specified frequencies

3.29 reference point, noun

location in the sound field used to determine the nominal peak pressure level and to provide the reference signal used when calculating ATF (3.2) open-ear waveforms

ISO/FDIS 4869-7:2026(en)

3.30 reference point microphone, noun

RPM, noun microphone located at the reference point (3.29) Note 1 to entry: The microphone can be mounted in a pressure probe body designed for measuring impulsive noise (3.24) sources.

3.31 requester, noun

party submitting a hearing protection device (3.16) and fitting instructions for testing Note 1 to entry: When the investigator is evaluating hearing protectors other than for an entity external to the laboratory, the requester (3.31) is considered to be the investigator conducting the research.

3.32 signal-to-noise-and-distortion ratio, noun

SINAD, noun level, in decibels, of the ratio of the root-mean-square (rms) amplitude of the analoganalogue-to-digital converter output signal for a full unclipped input signal to the rms amplitude of the output noise, where noise is defined to include not only random errors but also nonlinearnon-linear distortion and the effects of sampling time errors

3.33 signal-to-noise ratio

S/N, noun ratio of the spectrum level of the measurement microphone signal during the impulse to the spectrum level without the impulse but with typical background noise from the ambient environment and equipment operating in the vicinity of the test Note 1 to entry: This document uses S/N for signal-to-noise ratio (3.33) in order to reduce the potential confusion with [3] Single Number Rating, SNR, from ISO 4869-2:2018 ..

3.34 transfer function of the open ear, noun

TFOE, noun 𝑯𝑯 54T, noun 𝑻𝑻𝑻𝑻𝑻𝑻𝑻𝑻 ratio of the spectrum at the eardrum reference point (3.29) to the spectrum at the head reference point (3.29) with the head removed

4 Applicability of the test methods

The measurements obtained using this standarddocument are applicable for peak sound pressure levels ranging from 130 dB to 170 dB. These methods may be adapted to levels exceeding 170 dB as long as attention is paid to clipping and distortion limits of the instrumentation, beyond the requirements defined.

5 Requirements for product samples and band force

5.1 Required number of HPD samples

A minimum of five samples of the HPD under evaluation shall be used in each test. When the HPDs are supplied in multiple eartip sizes or cushions, an appropriate size that best fits the ATF providing a good seal shall be used. Each sample shall be marked with a unique identifier to be associated with all measurements made on that sample. For earplug searplugs, a sample consists of a pair of earplugs. For other HPDs, a sample is one pair of earmuff earmuffs, one banded earplug or one helmet-mounted HPD.

ISO/FDIS 4869-7:2026(en)

5.2 Conditioning of HPD samples

For HPD samples tested indoors, the samples shall be stored in a controlled environment for at least 24 hoursh before testing. The environment shall be maintained at a temperature of (22 ± 5) °C and relative humidity not to exceed 85 %. For samples tested in an uncontrolled environment, the temperature and humidity shall be recorded as indicated in 6.5.1 and 6.5.2.

5.3 Modification of HPD samples

For impulsive noise testing of HPDs that include deliberately designed sound transmission pathways (such as acoustical filters or pressure-equalization pathways that bypass the fundamental sealing capabilities of the device, see 7.1) but which do not include user-operable means to disable these pathways, then additional samples modified to block these pathways shall be tested to obtain the REAT data needed as part of the calculation of the 𝐴𝐴 . These additional HPD samples shall be modified by the laboratory to block these sound ILD transmission pathways in a manner that, in the experimenter’s best judgement, disables the pathways while minimally altering the fundamental attenuation capabilities of the device (e.g. do not add excessive mass). Either the requester or experimenter may identify the need for such modifications, and the decision to modify or not shall be justified in the test report. The requester may also suggest ways to disable such pathways to the experimenter and review the modifications to be done, but it is at the experimenter’s discretion as to what modifications to make. Furthermore, the test report shall document the modifications done, including photographs of the modified product, details on materials used, and mass changes. NOTE For example: aA manufacturer can provide a recommended procedure to occlude the acoustic filter of an HPD. If the HPD to be tested on an ATF has features meant to improve fit and seal to real ears which degrade fit and seal on the ATF, parts can be replaced by the manufacturer with alternatives meant to comparably fit the ATF. An example is a circumaural muff whose ear seals include a bump to fill the depression below the ear adjacent to the gonion which would create a leak when sealing to an ATF with a flat plane surrounding the pinna. Any such swapped parts shall be fabricated to be otherwise similar to the parts meant for use on human subjects, the experimenter shall inspect the parts to determine whether the similarity is satisfactory, and any replacement parts shall be noted in the test report.

...