ISO 15825
(Main)Rubber compounding ingredients — Carbon black — Determination of aggregate size distribution by disc centrifuge photosedimentometry
- Abstract
ISO 15825:2017 specifies a method for determining the size distribution of carbon black aggregates, using a disc centrifuge photosedimentometer. This technique is based on the hydrodynamic behaviour of carbon black in a centrifugal field. The determination of the aggregate size distribution is important in the evaluation of carbon black used in the rubber industry.
- Status
- Not Published
- Drafting Committee
- ISO/TC 45/SC 3/WG 3 - Carbon black, silica and rubber chemicals
- Current Stage
- 6000 - International Standard under publication - 60 Publication
- Start Date
- 10-Oct-2026
Buy Documents
ISO/FDIS 15825 - Rubber compounding ingredients — Carbon black — Determination of aggregate size distribution by disc centrifuge photosedimentometry
REDLINE ISO/FDIS 15825 - Rubber compounding ingredients — Carbon black — Determination of aggregate size distribution by disc centrifuge photosedimentometry
ISO/FDIS 15825 - Ingrédients de mélange de caoutchouc — Noir de carbone — Détermination de la distribution dimensionnelle des agrégats par photosédimentométrie avec centrifugeuse à disque
ISO 15825 is an International Organization for Standardization document for rubber compounding ingredients that specifies how to determine the aggregate size distribution of carbon black by disc centrifuge photosedimentometry. It is written for laboratories and industry users who need to measure carbon black used in the rubber industry, and it covers Method A with a disc centrifuge photosedimentometer (DCP) and Method B with a disc centrifuge photosedimentometer (CPS).
What does ISO 15825 specify?
ISO 15825 specifies a method for determining the size distribution of carbon black aggregates using a disc centrifuge photosedimentometer. The document is organized into scope, normative references, terms and definitions, significance and use, two test methods, precision, and test report requirements.
Method A is presented as the original test method. Method B uses a different type of instrument and is arranged for shorter test sequences.
| Annex | What it covers |
|---|---|
| Annex A | Example of a mass distribution curve |
| Annex B | Precision statement |
What are the key requirements of ISO 15825?
ISO 15825 is built around controlled dispersion, calibrated centrifugation, and reporting of mass-based aggregate size data. In practice, the reader needs to prepare the sample in a consistent way, choose the right instrument settings, and report the result in the same terms the standard defines.
Sampling and reference materials
ISO 15825 requires carbon black samples to be taken at random from larger lots in pelletized or non-pelletized form, in accordance with ISO 1124. This matters because the result should represent the lot, not just a convenient portion of it.
Both methods use reference materials to check that agglomerates are fully dispersed into aggregates. Method A uses ITRB or ITRB-2, while Method B uses ITRB-2. In practice, this is the routine check that tells the laboratory whether the sonication step is strong enough before testing real samples.
Dispersion and calibration
ISO 15825 requires ultrasonic dispersion before measurement, and the sonication conditions are set by calibration. For Method A, the calibration check is based on energy delivered to ITRB or ITRB-2 and the resulting mean Stokes diameter. For Method B, the calibration check is based on ITRB-2 and the resulting mode diameter.
This matters because under-dispersion leaves agglomerates intact and shifts the size distribution. If the reference material gives too large a value, the standard directs the user to increase sonication time or power, or change the sonicator tip.
Method A: DCP operating setup
ISO 15825 Method A uses a DCP with a rotating disc, ethanol, spin fluid, and dodecane. The software setup includes file name, sample designation, fluid temperature, disc speed, and light scattering correction using Mie correction for carbon black.
In practice, Method A depends on a clean, stable disc and a properly formed fluid layer. The procedure also requires checking for hydrodynamic instability or streaming, because those effects can distort the turbidity signal and invalidate the run.
Method B: CPS operating setup
ISO 15825 Method B uses a CPS and a sucrose density gradient. The software setup includes sample parameters, calibration standard parameters, fluid parameters, presentation parameters, and runtime options.
This matters because Method B is more instrument-specific: the operator enters particle density, refractive index, absorption, and other settings before running the measurement. The document also gives speed selection guidance based on specific surface area, so the instrument is matched to the expected carbon black grade.
Measurement and calculation
ISO 15825 converts detector attenuation into a mass distribution of aggregate sizes. For Method A, the result is obtained from continuously measured turbidity with a light scattering correction applied. For Method B, the weight distribution is calculated from the raw data curve.
The standard highlights the main output terms used in reporting: mean diameter, median, mode, quartile ratio, and ΔD-50. Annex A helps the reader interpret these values by showing how D_mean, D_mode, D_50, and spread measures behave on a distribution curve.
Precision and test reporting
ISO 15825 provides precision information in Annex B for both methods. The annex is based on interlaboratory trials and gives repeatability and reproducibility information for the main reported size descriptors.
Clause 8 then requires the test report to identify the sample, state the document reference and method used, record the sample mass and sonication conditions, identify the instrument and software, give the mass-distribution-based results, note deviations and anomalies, and include the test date. That makes the result traceable and easier to compare between laboratories.
What terms does ISO 15825 define?
- carbon black aggregate - A discrete, rigid colloidal entity that is the smallest dispersible unit in suspension; this is the size unit the standard measures.
- spin fluid - The inert liquid injected into the disc before the sample, through which aggregates sediment; in practice, it is the medium that carries the separation.
- dispersion fluid - The liquid in which the aggregates are dispersed before measurement; it is the sample-preparation medium.
- Stokes equation - The mathematical description used to relate sedimentation behavior to an equivalent diameter; it underpins the size calculation.
- Stokes diameter - The diameter of a sphere that would sediment at the same rate as the aggregate; this is the reported size basis in the test.
- mean diameter - The average diameter calculated from the differential mass distribution curve; it summarizes the full distribution.
- median - The diameter at which 50 % of the mass is larger and 50 % is smaller; it is the midpoint of the distribution.
- mode - The diameter with the most frequent occurrence in the distribution; it shows the peak size class.
Who uses ISO 15825?
ISO 15825 is used by laboratories, rubber compounders, carbon black manufacturers, quality managers, and buyers who need a consistent way to compare carbon black grades. It is especially relevant in the rubber industry, where aggregate size affects how carbon black performs in compounding and downstream processing.
Typical tasks include incoming inspection, lot comparison, product development, and routine quality control. The standard also helps when a supplier and customer need the same measurement language for carbon black aggregate size distribution.
What changed in ISO 15825 from the previous edition?
ISO 15825:2026 is the fourth edition and it cancels and replaces ISO 15825:2017. The foreword states that the document was technically revised.
The changes listed are:
- addition of a new Method B in Clauses 1 and 6
- addition of precision data in Annex B
- addition of the CAS number for the reagents
Which standards are used with ISO 15825?
ISO 15825 cites two normative references and one precision reference in Annex B.
- ISO 1124 - Provides carbon black shipment sampling procedures, which the sampling clauses use.
- ISO 3696 - Specifies grade 3 water for analytical laboratory use, which the reagent sections use for water preparation.
- ISO/TR 9272 - Used in Annex B for precision terminology and statistical treatment of the interlaboratory data.
What does the ISO 15825 document contain?
ISO 15825 contains two complete measurement routes, one for DCP and one for CPS, each with principle, apparatus, reagents and materials, sampling, calibration, sample preparation, setup, and initiation steps. It also contains a calculation section for Method B, a precision clause, and a test report clause.
Annex A provides an example mass distribution curve and explains how to read the main descriptors from it. Annex B gives precision statements and interlaboratory data for Method A and Method B, including the repeatability and reproducibility framework used for the reported size descriptors.
The document also includes the practical details needed to run the test consistently, such as sonication checks, fluid preparation, instrument parameters, stability checks, and handling after the run. In use, it serves as a laboratory method for testing, comparison, and reporting of carbon black aggregate size distribution.
Relations
- Effective Date
- 02-Sep-2023
Buy Documents
ISO/FDIS 15825 - Rubber compounding ingredients — Carbon black — Determination of aggregate size distribution by disc centrifuge photosedimentometry
REDLINE ISO/FDIS 15825 - Rubber compounding ingredients — Carbon black — Determination of aggregate size distribution by disc centrifuge photosedimentometry
ISO/FDIS 15825 - Ingrédients de mélange de caoutchouc — Noir de carbone — Détermination de la distribution dimensionnelle des agrégats par photosédimentométrie avec centrifugeuse à disque
Get Certified
Connect with accredited certification bodies for this standard
DIN CERTCO
DIN Group product certification.

Smithers Quality Assessments
US management systems and product certification.
Sponsored listings
Frequently Asked Questions
ISO 15825 is a draft published by the International Organization for Standardization (ISO). Its full title is "Rubber compounding ingredients — Carbon black — Determination of aggregate size distribution by disc centrifuge photosedimentometry". This standard covers: ISO 15825:2017 specifies a method for determining the size distribution of carbon black aggregates, using a disc centrifuge photosedimentometer. This technique is based on the hydrodynamic behaviour of carbon black in a centrifugal field. The determination of the aggregate size distribution is important in the evaluation of carbon black used in the rubber industry.
ISO 15825:2017 specifies a method for determining the size distribution of carbon black aggregates, using a disc centrifuge photosedimentometer. This technique is based on the hydrodynamic behaviour of carbon black in a centrifugal field. The determination of the aggregate size distribution is important in the evaluation of carbon black used in the rubber industry.
ISO 15825 is classified under the following ICS (International Classification for Standards) categories: 83.040.20 - Rubber compounding ingredients. The ICS classification helps identify the subject area and facilitates finding related standards.
ISO 15825 has the following relationships with other standards: It is inter standard links to ISO 15825:2017. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
ISO 15825 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 3.1 General terms
- 3.1.1 carbon black aggregate
- 3.1.2 spin fluid
- 3.1.3 dispersion fluid
- 3.1.4 Stokes equation
- 3.1.5 particle density
- 3.2 Terms concerning aggregate dimensions
- 3.2.1 Stokes diameter
- 3.2.2 mean diameter
- 3.2.3 median
- 3.2.4 mode
- 3.2.5 lower quartile
- 3.2.6 upper quartile
- 3.2.7 quartile ratio
- 3.2.8 ΔD-50
- 4 Significance and use
- 5 Method A: disc centrifuge (DCP)
- 5.1 Principle
- 5.2 Apparatus
- 5.3 Reagents and materials
- 5.4 Sampling
- 5.5 Calibration
- 5.6 Preparation of test sample
- 5.7 Computer and software setup
- 5.8 Initiation of procedure
- 6 Method B: disc centrifuge (CPS)
- 6.1 Principle
- 6.2 Apparatus
- 6.3 Reagents and materials
- 6.4 Sampling
- 6.5 Calibration
- 6.6 Preparation of test sample
- 6.7 Set-up of equipment and test parameters
- 6.8 Initiation of procedure
- 6.9 Calculation
- 7 Precision
- 8 Test report
- Annex A
- Annex B
- Bibliography
1 Scope
This document specifies a method for determining the size distribution of carbon black aggregates, using a disc centrifuge photosedimentometer.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 1124, Rubber compounding ingredients — Carbon black shipment sampling procedures ISO 3696, Water for analytical laboratory use — Specification and test methods
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:
- ISO Online browsing platform: available at https:// www .iso .org/ obp
- IEC Electropedia: available at https:// www .electropedia .org/
3.1 General terms
3.1.1 carbon black aggregate
discrete, rigid colloidal entity that is the smallest dispersible unit in a suspension Note 1 to entry: Carbon black aggregates are composed of extensively coalesced particles.
3.1.2 spin fluid
inert liquid injected into the disc prior to the sample, through which aggregates sediment Note 1 to entry: Alkaline conditions minimize agglomeration of dispersed aggregates in most cases.
3.1.3 dispersion fluid
liquid in which aggregates are dispersed
ISO/FDIS 15825:2026(en)
3.1.4 Stokes equation
mathematical description of the sedimentation of a spherical particle:
R
1,81 0 ln
S
D st
t
where D is the Stokes diameter (nm); st η is the viscosity of the spin fluid (Pa·s); R is the distance of the photodetector from the centre of rotation (cm); S is the distance of the air-liquid interface from the centre of rotation (cm); t is the time of centrifugation (s);
ρ is the density of the carbon black (Mg/m );
ρ is the density of the spin fluid (Mg/m );
ω is the rotational velocity (rad/s).
3.1.5 particle density
density of the aggregate in Mg/m Note 1 to entry: The particle density of carbon black can vary per carbon black type. The value for the carbon black 3 3 3 3 3 3 density to be entered into the DCP software is 1,86 × 10 kg/m (1,86 g/cm ) and 1,98 × 10 kg/m (1,98 g/cm ) for the CPS. Both values are typical values, found in literature. While both methods refer to photosedimentometry, the detailed principles differ. By applying the different densities in the device software, the measurement curves for the DCP and the CPS are very comparable.
3.2 Terms concerning aggregate dimensions
3.2.1 Stokes diameter
D st diameter of a sphere which sediments in a viscous medium in a centrifugal or gravitational field according to the Stokes equation Note 1 to entry: A non-spherical object, such as a carbon black aggregate, can also be represented in terms of an equivalent Stokes diameter if it is considered as behaving as a smooth, rigid sphere of the same density and with the same sedimentation rate as the object.
Note 2 to entry: For carbon black, Stokes diameter is expressed in nanometres (nm).
3.2.2 mean diameter
D mean average diameter calculated from the differential mass distribution curve Note 1 to entry: Mean diameter represents the first moment of the differential distribution. Note 2 to entry: In the software of the Brookhaven disc centrifuge, the mass distribution is called “Volume (Mass)” and mean diameter is reported as “Mean”. In the CPS software, the mass distribution is called “Weight” and the mean diameter is reported as “Mean”.
Note 3 to entry: D is used for reporting purposes only.
mean
ISO/FDIS 15825:2026(en)
3.2.3 median
D
x-value of the point on the mass distribution curve at which 50 % by mass of the test sample is larger and 50 % by mass of the test sample is smaller Note 1 to entry: The D50 represents the median value of the distribution. Note 2 to entry: In the software of the Brookhaven disc centrifuge, the median Stokes diameter is reported as “d50”. In the software of the CPS disc centrifuge, the median Stokes diameter is reported as “Median”. Note 3 to entry: D is used for reporting purposes only.
3.2.4 mode
D mode value at which the most frequent diameter occurrence is observed, which is portrayed as a peak in the distribution curve Note 1 to entry: In some cases, there can be more than one mode indicated. Note 2 to entry: In the CPS disc centrifuge software, the mode is reported as “Peak”. Note 3 to entry: D is used for reporting purposes only.
mode
3.2.5 lower quartile
x-value of the point on the mass distribution curve at which 75 % of the sample is larger, and 25 % smaller
3.2.6 upper quartile
x-value of the point on the mass distribution curve at which 75 % of the sample is smaller, and 25 % larger
3.2.7 quartile ratio
ratio of upper quartile to lower quartile Note 1 to entry: In the software of the Brookhaven disc centrifuge, the quartile ratio is reported as “d75/d25”.
3.2.8 ΔD-50
width of the plot of the mass distribution measured at the half-maximum point of the mode, which is a measure of the breadth of the aggregate size distribution Note 1 to entry: In the software of the Brookhaven disc centrifuge, ΔD 50 is reported as “FWHM” (full width at half maximum). In the CPS disc centrifuge software, the ΔD 50 is reported as “Width at 50 % height”.
4 Significance and use
This technique is based on the hydrodynamic behaviour of carbon black in a centrifugal field. The determination of the aggregate size distribution is important in the evaluation of carbon black used in the rubber industry.
Method A has been the original test method for this standard.
Method B uses another type of instrument which allows shorter test sequences. Disc centrifuge photosedimentometry produces a rapid mass-differential aggregate size distribution, by continuously measuring the solution turbidity as a function of centrifugation time. In order to obtain a true mass distribution, a light scattering correction shall be applied. An example of a mass distribution curve is given in Annex A.
ISO/FDIS 15825:2026(en)
5 Method A: disc centrifuge (DCP)
5.1 Principle
The disc centrifuge separates particles by size using centrifugal sedimentation in a liquid medium. The particles sediment inside a transparent rotating disc, through which a light beam passes. As particles move towards the outer edge of the disc, they pass through the light beam, attenuating the beam intensity. Detector beam attenuation is continuously recorded and converted by the operating software into the weight of particles at each size in the sample.
5.2 Apparatus
1)
5.2.1 Disc centrifuge photosedimentometer (DCP) , capable of rotational speeds of 1 000 r/min to
11 000 r/min or greater, with integral spin feed-back control (accuracy and stability of rotational speed 3 3 better than ±0,05 %), spin fluid volume from 10 cm to 20 cm , stable temperature of spin fluid, stroboscope to monitor the rotating disc both for stability and streaming anomalies, and an appropriate optical turbidity measuring device.
5.2.2 Energy meter, capable of measuring the energy consumption (in kWh) of the probe-type sonicator. The energy meter is inserted between an electrical plug of the laboratory and the plug of the power supply cord of the sonicator. The actual energy consumption is indicated on a digital display. 2) 5.2.3 Probe-type sonicator , typically with a nominal power of 200 W or more. The sonicator should be capable of providing a measured power consumption of at least 60 W. This has been found to be an effective means of dispersing carbon black into discrete aggregates. See 5.5 for further details.
NOTE Cylindrical tips with 12,7 mm (1/2 inch) diameter have been found to be suitable.
5.2.4 Microsyringe, 2 cm or less.
5.2.5 Syringe, 20 cm or less.
5.3 Reagents and materials
Unless otherwise stated, use only reagents of recognized reagent grade. 5.3.1 Water, distilled or deionized, grade 3 as defined in ISO 3696. ®3) 5.3.2 Ethanol, absolute, CAS No. 64-17-5.
1) BI-DCP Particle Sizer is available from Brookhaven Instruments Corporation, 750 Blue Point Rd., Holtsville, NY 11742, USA, www .b rookhaveni nstruments .com. Joyce Loebl DCF 4 is no longer available. It is an example of a suitable product available commercially. This information is given for the convenience of users of this document and does not constitute an endorsement by ISO of these products. Equivalent products may be used if they can be shown to lead to the same results. 2) Sonoplus 2220, equipped with Sonotrode UW 2200 and horn DH 13 G, is available from BANDELIN electronic GmbH & Co. KG, Heinrichstraße 3-4, D-12207 Berlin, www .bandelin .com. It is an example of a suitable product available commercially. This information is given for the convenience of users of this document and does not constitute an endorsement by ISO of this product. Equivalent products may be used if they can be shown to lead to the same results. 3) CAS Registry Number® is a trademark of the American Chemical Society (ACS). This information is given for the convenience of users of this document and does not constitute an endorsement by ISO of the product named. Equivalent products may be used if they can be shown to lead to the same results.
ISO/FDIS 15825:2026(en) 4) 5.3.3 Surfactant, non-ionic type , 0,2 g/kg to 0,5 g/kg solution.
5.3.4 Dodecane, ≥ 98 % purity (GC grade), CAS No. 112-40-3.
5.3.5 Spin fluid, water (5.3.1) containing surfactant (5.3.3) which can be adjusted to pH 9,0 to pH 10,0
using 0,1 mol/dm NaOH.
3 3 5.3.6 Dispersion fluid, a solution of 20 cm of ethanol (5.3.2) and 80 cm of water (5.3.1) containing a
surfactant (5.3.3). The solution can be adjusted to a pH value between 9,0 and pH 10,0 using 0,1 mol/dm NaOH.
5.4 Sampling
Select carbon black samples from larger-sized lots at random, in either pelletized or non-pelletized form, in accordance with ISO 1124. Label and retain samples for storage or further analysis.
5.5 Calibration
5.5.1 The following procedure shall ensure that carbon black agglomerates are completely dispersed into aggregates.
5.5.2 Prepare a sample of ITRB (or ITRB−2) following the instructions in 5.6. 5.5.3 Select sonication energy and sonication mode (e.g. pulsed mode) in such way that 0,005 kWh (18 kJ) are applied. This can typically be achieved by a power of 60 W and a sonication time of 5 min. 5.5.4 Start sonication and press on start button of the energy-meter, which is plugged in between supply plug and plug of the power cord of the sonicator.
5.5.5 Stop sonication after 5 min, press stop button on energy-meter and read energy consumption, expressed in kWh.
5.5.6 If the ITRB or ITRB−2 is entirely dispersed, it will give a mean Stokes diameter (“mean”) of 105 nm ± 5 nm (99 nm ± 5 nm for ITRB−2).
5.5.7 Test ITRB or ITRB−2 as a standard carbon black on a regular basis before testing actual samples. 5.5.8 If the value of the standard is too high, either increase sonication time or power or change the tip of the sonicator.
NOTE The tips of the sonicator are consumed with time.
5.6 Preparation of test sample
5.6.1 Weigh 20 mg of carbon black in a weighing vessel.
If the software cannot handle high turbidity values, reduce the sample mass.
5.6.2 Add to 20 cm of dispersion fluid (5.3.6).
4) Nonidet P-40, from Shell Chemicals, has been found suitable for this application. This information is given for the convenience of users of this document and does not constitute an endorsement by ISO of the product named. Any other equivalent non-ionic type of surfactant may be used.
ISO/FDIS 15825:2026(en) 5.6.3 Disperse with ultrasonic energy for the time found during calibration (5.5), with the dispersing container immersed in a cooling medium, such as iced water, to minimize the heating effect of the sonic energy during sonication. The temperature of the test sample shall be approximately the same as ambient temperature, to minimize thermal gradients in the disc.
Test samples shall be subjected to further sonication if there is any indication of streaming, or more than 1 h has elapsed since sonication.
5.7 Computer and software setup
Input the appropriate parameters, including the following:
a) File name.
b) Sample designation.
c) Fluid temperature: enter the actual temperature, displayed by the instrument after having run the test, for the calculation.
d) Fluid density and fluid viscosity: do not enter a figure, but choose the option “spin fluid = water”. e) Disc speed.
f) Choose light scattering correction (Mie correction, carbon black).
5.8 Initiation of procedure
5.8.1 Set the rotational speed. In general, 8 000 r/min to 11 000 r/min for reinforcing grades and 4 000 r/ min to 6 500 r/min for semi-reinforcing grades is suitable. Prior to the test, a 30 min warm-up phase at the chosen speed is necessary. Make sure that the spin fluid used in 5.8.3 is at room temperature. Keep the air filter of the test instrument clean at all time so that a temperature rise at the rotating disc cell during testing is avoided.
NOTE Effective air ventilation can be achieved by keeping the ventilation window of the instrument open.
5.8.2 Inject 1,0 cm of ethanol (5.3.2) using a microsyringe and start the centrifuge.
5.8.3 Inject carefully 15 cm of the spin fluid (5.3.5) using a syringe to underlay the ethanol.
...
Contents
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 3.1 General terms
- 3.1.5 particle density
- 3.2 Terms concerning aggregate dimensions
- 4 Significance and use
- 5 Method A: disc centrifuge (DCP)
- 5.1 Principle
- 5.2 Apparatus
- 5.3 Reagents and materials
- 5.4 Sampling
- 5.5 Calibration
- 5.6 Preparation of test sample
- 5.7 Computer and software setup
- 5.8 Initiation of procedure
- 6 Method B: disc centrifuge (CPS)
- 6.1 Principle
- 6.2 Apparatus
- 6.3 Reagents and materials
- 6.4 Sampling
- 6.5 Calibration
- 6.6 Preparation of test sample
- 6.7 Set-up of equipment and test parameters
- 6.8 Initiation of procedure
- 6.9 Calculation
- 7 Precision
- 8 Test report
- Annex A
- Annex B
- Bibliography
1 Scope
This document specifies a method for determining the size distribution of carbon black aggregates, using a disc centrifuge photosedimentometer.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 1124, Rubber compounding ingredients — Carbon black shipment sampling procedures ISO 3696, Water for analytical laboratory use — Specification and test methods
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:
- — ISO Online browsing platform: available at https://www.iso.org/obp
- — IEC Electropedia: available at https://www.electropedia.org/
3.1 General terms
3.1.1 3.1.1 carbon black aggregate discrete, rigid colloidal entity that is the smallest dispersible unit in a suspension Note 1 to entry: Carbon black aggregates are composed of extensively coalesced particles. 3.1.2 3.1.2 spin fluid inert liquid injected into the disc prior to the sample, through which aggregates sediment Note 1 to entry: Alkaline conditions minimize agglomeration of dispersed aggregates in most cases. 3.1.3 3.1.3 dispersion fluid liquid in which aggregates are dispersed 3.1.4 3.1.4 Stokes equation mathematical description of the sedimentation of a spherical particle:
ISO/FDIS 15825:2026(en) 𝑅𝑅
1,8 × 10 𝜂𝜂ln( ) � 𝑆𝑆 𝐷𝐷 = st
(𝜌𝜌 − 𝜌𝜌 )𝜔𝜔𝑡𝑡 1 2 where Dst is the Stokes diameter (nm); η is the viscosity of the spin fluid (Pa·s); R is the distance of the photodetector from the centre of rotation (cm); S is the distance of the air-liquid interface from the centre of rotation (cm); t is the time of centrifugation (s);
ρ1 is the density of the carbon black (Mg/m );
ρ2 is the density of the spin fluid (Mg/m ); ω is the rotational velocity (rad/s).
3.1.5 particle density
density of the aggregate in Mg/m Note 1 to entry: The particle density of carbon black can vary per carbon black type. The value for the carbon black 3 3 3 3 3 3 density to be entered into the DCP software is 1,86 × 10 kg/m (1,86 g/cm ) and 1,98 × 10 kg/m (1,98 g/cm ) for the CPS. Both values are typical values, found in literature. While both methods refer to photosedimentometry, the detailed principles differ. By applying the different densities in the device software, the measurement curves for the DCP and the CPS are very comparable.
3.2 Terms concerning aggregate dimensions
3.2.1 3.2.1 Stokes diameter D st diameter of a sphere which sediments in a viscous medium in a centrifugal or gravitational field according to the Stokes equation Note 1 to entry: A non-spherical object, such as a carbon black aggregate, can also be represented in terms of an equivalent Stokes diameter if it is considered as behaving as a smooth, rigid sphere of the same density and with the same sedimentation rate as the object.
Note 2 to entry: For carbon black, Stokes diameter is expressed in nanometres (nm). 3.2.2 3.2.2 mean diameter D mean average diameter calculated from the differential mass distribution curve Note 1 to entry: Mean diameter represents the first moment of the differential distribution. Note 2 to entry: In the software of the Brookhaven disc centrifuge, the mass distribution is called “Volume (Mass)” and mean diameter is reported as “Mean”. In the CPS software, the mass distribution is called “Weight” and the mean diameter is reported as “Mean”.
Note 3 to entry: D is used for reporting purposes only.
mean 3.2.3 3.2.3 median D
x-value of the point on the mass distribution curve at which 50 % by mass of the test sample is larger and 50 % by mass of the test sample is smaller
ISO/FDIS 15825:2026(en) Note 1 to entry: The D50 represents the median value of the distribution. Note 2 to entry: In the software of the Brookhaven disc centrifuge, the median Stokes diameter is reported as “d50”. In the software of the CPS disc centrifuge, the median Stokes diameter is reported as “Median”. Note 3 to entry: D is used for reporting purposes only.
3.2.4 3.2.4 mode D mode value at which the most frequent diameter occurrence is observed, which is portrayed as a peak in the distribution curve Note 1 to entry: In some cases, there can be more than one mode indicated. Note 2 to entry: In the CPS disc centrifuge software, the mode is reported as “Peak”. Note 3 to entry: Dmode is used for reporting purposes only.
3.2.5 3.2.5 lower quartile x-value of the point on the mass distribution curve at which 75 % of the sample is larger, and 25 % smaller 3.2.6 3.2.6 upper quartile x-value of the point on the mass distribution curve at which 75 % of the sample is smaller, and 25 % larger 3.2.7 3.2.7 quartile ratio ratio of upper quartile to lower quartile Note 1 to entry: In the software of the Brookhaven disc centrifuge, the quartile ratio is reported as “d75/d25”. 3.2.8 3.2.8 ΔD-50 width of the plot of the mass distribution measured at the half-maximum point of the mode, which is a measure of the breadth of the aggregate size distribution Note 1 to entry: In the software of the Brookhaven disc centrifuge, ΔD 50 is reported as “FWHM” (full width at half maximum). In the CPS disc centrifuge software, the ΔD 50 is reported as “Width at 50 % height”.
4 Significance and use
This technique is based on the hydrodynamic behaviour of carbon black in a centrifugal field. The determination of the aggregate size distribution is important in the evaluation of carbon black used in the rubber industry.
Method A has been the original test method for this standard.
Method B uses another type of instrument which allows shorter test sequences. Disc centrifuge photosedimentometry produces a rapid mass-differential aggregate size distribution, by continuously measuring the solution turbidity as a function of centrifugation time. In order to obtain a true mass distribution, a light scattering correction shall be applied. An example of a mass distribution curve is given in Annex AAnnex A..
ISO/FDIS 15825:2026(en)
5 Method A: disc centrifuge (DCP)
5.1 Principle
The disc centrifuge separates particles by size using centrifugal sedimentation in a liquid medium. The particles sediment inside a transparent rotating disc, through which a light beam passes. As particles move towards the outer edge of the disc, they pass through the light beam, attenuating the beam intensity. Detector beam attenuation is continuously recorded and converted by the operating software into the weight of particles at each size in the sample.
5.2 Apparatus
1 1) 5.2.1 5.2.1 Disc centrifuge photosedimentometer (DCP) , , capable of rotational speeds of 1 000 r/min to 11 000 r/min or greater, with integral spin feed-back control (accuracy and stability of 3 3 rotational speed better than ±0,05 %), spin fluid volume from 10 cm to 20 cm , stable temperature of spin fluid, stroboscope to monitor the rotating disc both for stability and streaming anomalies, and an appropriate optical turbidity measuring device.
5.2.2 5.2.2 Energy meter, capable of measuring the energy consumption (in kWh) of the probe-type sonicator.
The energy meter is inserted between an electrical plug of the laboratory and the plug of the power supply cord of the sonicator. The actual energy consumption is indicated on a digital display. 2 2) 5.2.3 5.2.3 Probe-type sonicator , , typically with a nominal power of 200 W or more. The sonicator should be capable of providing a measured power consumption of at least 60 W. This has been found to be an effective means of dispersing carbon black into discrete aggregates. See 5.55.5 for further details.
NOTE Cylindrical tips with 12,7 mm (1/2 inch) diameter have been found to be suitable.
5.2.4 5.2.4 Microsyringe, 2 cm or less.
5.2.5 5.2.5 Syringe, 20 cm or less.
5.3 Reagents and materials
Unless otherwise stated, use only reagents of recognized reagent grade. 5.3.1 5.3.1 Water, distilled or deionized, grade 3 as defined in ISO 3696.
1) BI-DCP Particle Sizer is available from Brookhaven Instruments Corporation, 750 Blue Point Rd., Holtsville, NY 11742, USA, www.brookhaveninstruments.com. Joyce Loebl DCF 4 is no longer available. It is an example of a suitable product available commercially. This information is given for the convenience of users of this document and does not constitute an endorsement by ISO of these products. Equivalent products may be used if they can be shown to lead to the same results.
2) Sonoplus 2220, equipped with Sonotrode UW 2200 and horn DH 13 G, is available from BANDELIN electronic GmbH & Co. KG, Heinrichstraße 3-4, D-12207 Berlin, www.bandelin.com. It is an example of a suitable product available commercially. This information is given for the convenience of users of this document and does not constitute an endorsement by ISO of this product. Equivalent products may be used if they can be shown to lead to the same results.
ISO/FDIS 15825:2026(en) ®3) 5.3.2 5.3.2 Ethanol, absolute, CAS- No.. 64-17-5.
3 4) 5.3.3 5.3.3 Surfactant, non-ionic type , , 0,2 g/kg to 0,5 g/kg solution.
5.3.4 5.3.4 Dodecane, ≥ 98 % purity (GC grade), CAS- No.. 112-40-3. 5.3.5 5.3.5 Spin fluid, water (5.3.1(5.3.1)) containing surfactant (5.3.3(5.3.3)) which can be adjusted to
pH 9,0 to pH 10,0 using 0,1 mol/dm NaOH.
3 3 5.3.6 5.3.6 Dispersion fluid, a solution of 20 cm of ethanol (5.3.2(5.3.2)) and 80 cm of water (5.3.1(5.3.1)) containing a surfactant (5.3.3(5.3.3).). The solution can be adjusted to a pH value between 9,0
and pH 10,0 using 0,1 mol/dm NaOH.
5.4 Sampling
Select carbon black samples from larger-sized lots at random, in either pelletized or non-pelletized form, in accordance with ISO 1124. Label and retain samples for storage or further analysis.
5.5 Calibration
5.5.1 5.5.1 The following procedure shall ensure that carbon black agglomerates are completely dispersed into aggregates.
5.5.2 5.5.2 Prepare a sample of ITRB (or ITRB−2) following the instructions in 5.65.6.. 5.5.3 5.5.3 Select sonication energy and sonication mode (e.g. pulsed mode) in such way that 0,005 kWh (18 kJ) are applied. This can typically be achieved by a power of 60 W and a sonication time of 5 min. 5.5.4 5.5.4 Start sonication and press on start button of the energy-meter, which is plugged in between supply plug and plug of the power cord of the sonicator.
5.5.5 5.5.5 Stop sonication after 5 min, press stop button on energy-meter and read energy consumption, expressed in kWh.
5.5.6 5.5.6 If the ITRB or ITRB−2 is entirely dispersed, it will give a mean Stokes diameter (“mean”) of 105 nm ± 5 nm (99 nm ± 5 nm for ITRB−2).
5.5.7 5.5.7 Test ITRB or ITRB−2 as a standard carbon black on a regular basis before testing actual samples.
5.5.8 5.5.8 If the value of the standard is too high, either increase sonication time or power or change the tip of the sonicator.
NOTE The tips of the sonicator are consumed with time.
5.6 Preparation of test sample
5.6.1 5.6.1 Weigh 20 mg of carbon black in a weighing vessel.
3) CAS Registry Number® is a trademark of the American Chemical Society (ACS). This information is given for the convenience of users of this document and does not constitute an endorsement by ISO of the product named. Equivalent products may be used if they can be shown to lead to the same results.
4) Nonidet P-40, from Shell Chemicals, has been found suitable for this application. This information is given for the convenience of users of this document and does not constitute an endorsement by ISO of the product named. Any other equivalent non-ionic type of surfactant may be used.
ISO/FDIS 15825:2026(en) If the software cannot handle high turbidity values, reduce the sample mass.
5.6.2 5.6.2 Add to 20 cm of dispersion fluid (5.3.6(5.3.6).).
5.6.3 5.6.3 Disperse with ultrasonic energy for the time found during calibration (5.5(5.5),), with the dispersing container immersed in a cooling medium, such as iced water, to minimize the heating effect of the sonic energy during sonication. The temperature of the test sample shall be approximately the same as ambient temperature, to minimize thermal gradients in the disc. Test samples shall be subjected to further sonication if there is any indication of streaming, or more than 1 h has elapsed since sonication.
5.7 Computer and software setup
Input the appropriate parameters, including the following:
a) a) File name.
b) b) Sample designation.
c) c) Fluid temperature: enter the actual temperature, displayed by the instrument after having run the test, for the calculation.
d) d) Fluid density and fluid viscosity: do not enter a figure, but choose the option “spin fluid = water”.
e) e) Disc speed.
f) f) Choose light scattering correction (Mie correction, carbon black).
5.8 Initiation of procedure
5.8.1 5.8.1 Set the rotational speed. In general, 8 000 r/min to 11 000 r/min for reinforcing grades and 4 000 r/min to 6 500 r/min for semi-reinforcing grades is suitable. Prior to the test, a 30 min warm-up phase at the chosen speed is necessary. Make sure that the spin fluid used in 5.8.35.8.3 is at room temperature. Keep the air filter of the test instrument clean at all time so that a temperature rise at the rotating disc cell during testing is avoided.
NOTE Effective air ventilation can be achieved by keeping the ventilation window of the instrument open.
5.8.2 5.8.2 Inject 1,0 cm of ethanol (5.3.2(5.3.2)) using a microsyringe and start the centrifuge.
5.8.3 5.8.3 Inject carefully 15 cm of the spin fluid (5.3.5(5.3.5)) using a syringe to underlay the ethanol.
5.8.4 5.8.4 Inject 0,1 cm of dodecane (5.3.4(5.3.4)) using a microsyringe on top of the gradient layer to reduce evaporative cooling.
...
Contents
- 1 Domaine d’application
- 2 Références normatives
- 3 Termes et définitions
- 3.1 Termes généraux
- 3.1.1 agrégat de noir de carbone
- 3.1.2 fluide de rotation
- 3.1.3 fluide de dispersion
- 3.1.4 équation de Stokes
- 3.1.5 masse volumique des particules
- 3.2 Termes concernant les dimensions des agrégats
- 3.2.1 diamètre de Stokes
- 3.2.2 diamètre moyen
- 3.2.3 médiane
- 3.2.4 mode
- 3.2.5 quartile inférieur
- 3.2.6 quartile supérieur
- 3.2.7 rapport de quartile
- 3.2.8 ΔD-50
- 4 Intérêt et utilisation
- 5 Méthode A: Centrifugeuse à disque (DCP)
- 5.1 Principe
- 5.2 Appareillage
- 5.3 Réactifs et matériaux
- 5.4 Échantillonnage
- 5.5 Étalonnage
- 5.6 Préparation de l’échantillon d’essai
- 5.7 Réglage de l'équipement informatique et du logiciel
- 5.8 Lancement du mode opératoire
- 6 Méthode B: Centrifugeuse à disque (CPS)
- 6.1 Principe
- 6.2 Appareillage
- 6.3 Réactifs et matériaux
- 6.4 Échantillonnage
- 6.5 Étalonnage
- 6.6 Préparation de l’échantillon d’essai
- 6.7 Réglage de l'équipement et des paramètres d'essai
- 6.8 Lancement du mode opératoire
- 6.9 Calcul
- 7 Rapport d’essai
- 8 Rapport d’essai
- Annexe A
- Annexe B
- Bibliographie
1 Domaine d’application
Le présent document spécifie une méthode pour la détermination de la distribution dimensionnelle des agrégats de noir de carbone à l'aide d'un photosédimentomètre. avec centrifugeuse à disque.
2 Références normatives
Les documents suivants sont cités dans le texte de sorte qu’ils constituent, pour tout ou partie de leur contenu, des exigences du présent document. Pour les références datées, seule l’édition citée s’applique. Pour les références non datées, la dernière édition du document de référence s'applique (y compris les éventuels amendements).
ISO 1124, Ingrédients de mélange du caoutchouc — Procédures d'échantillonnage sur des livraisons de noir de carbone ISO 3696, Eau pour laboratoire à usage analytique — Spécification et méthodes d'essai
3 Termes et définitions
Pour les besoins du présent document, les termes et définitions suivants s’appliquent. L’ISO et l’IEC tiennent à jour des bases de données terminologiques destinées à être utilisées en normalisation, consultables aux adresses suivantes:
- ISO Online browsing platform: disponible à l’adresse https:// www .iso .org/ obp
- IEC Electropedia: disponible à l’adresse https:// www .electropedia .org/
3.1 Termes généraux
3.1.1 agrégat de noir de carbone
entité distincte, rigide et colloïdale, représentant la plus petite unité de dispersion dans une suspension Note 1 à l'article: Il est constitué de particules intimement soudées par fusion.
3.1.2 fluide de rotation
liquide inerte injecté sur le disque avant la prise d'essai, dans lequel l'agrégat sédimente Note 1 à l'article: Dans la plupart des cas, des conditions alcalines réduisent au minimum l'agglomération des agrégats dispersés.
3.1.3 fluide de dispersion
liquide dans lequel les agrégats sont dispersés
ISO/FDIS 15825:2026(fr)
3.1.4 équation de Stokes
formule mathématique décrivant la sédimentation d'une particule sphérique:
R
1,81 0 ln
S
D st
t
où D est le diamètre de Stokes (nm); st η est la viscosité du fluide de rotation (Pa·s); R la distance du photodétecteur par rapport au centre de rotation (cm); S est la distance de l'interface entre l'air et le liquide par rapport au centre de rotation (cm); t est le temps de centrifugation (s);
ρ est la masse volumique du noir de carbone (Mg/m );
ρ est la masse volumique du fluide de rotation (Mg/m );
ω est la vitesse de rotation (rad/s).
3.1.5 masse volumique des particules
masse volumique de l'agrégat en Mg/m Note 1 à l'article: La masse volumique des particules de noir de carbone peut varier selon le type de noir de carbone. La 3 3 3 valeur de la masse volumique du noir de carbone à introduire dans le logiciel DCP est de 1,86 × 10 kg/m (1,86 g/cm ) 3 3 3 et de 1,98 × 10 kg/m (1,98 g/cm ) pour le CPS. Les deux valeurs sont des valeurs types, tirées de la littérature. Bien que les deux méthodes fassent référence à la photosédimentométrie, les principes détaillés diffèrent. En appliquant les différentes masses volumiques dans le logiciel de l'appareil, les courbes de mesure pour le DCP et le CPS sont largement comparables.
3.2 Termes concernant les dimensions des agrégats
3.2.1 diamètre de Stokes
D st diamètre d'une particule sphérique qui sédimente au sein d'un milieu visqueux dans un champ centrifuge ou gravitationnel selon l'équation de Stokes Note 1 à l'article: Une particule non sphérique, tel qu'un agrégat de noir de carbone, peut aussi être représentée en termes d'équivalent du diamètre de Stokes, si l'on considère qu'elle se comporte comme une particule sphérique rigide, lisse ayant la même masse volumique et la même vitesse de sédimentation. Note 2 à l'article: Les diamètres des particules de noir de carbone sont exprimés en nanomètres (nm).
3.2.2 diamètre moyen
D mean diamètre moyen calculé à partir de la courbe de distribution différentielle de masse Note 1 à l'article: Il représente le premier instant de la distribution différentielle. Note 2 à l'article: Dans le logiciel de la centrifugeuse à disque Brookhaven, la distribution de masse est dénommée «Volume (masse)» et le diamètre moyen est enregistré en tant que «Moyenne». Dans le logiciel de la centrifugeuse à disque CPS la distribution de masse est appelée «Masse» et le diamètre moyen est indiqué comme «Moyenne». Note 3 à l'article: D est utilisé uniquement à des fins d'enregistrement. mean
ISO/FDIS 15825:2026(fr)
3.2.3 médiane
D
point de la courbe de distribution de masse où 50 % de la prise d'essai en masse sont des particules plus grosses ou plus fines de part et d'autre de ce point Note 1 à l'article: Ce point représente donc la valeur médiane de la distribution. Note 2 à l'article: Dans le logiciel de la centrifugeuse à disque Brookhaven, le diamètre de Stokes médian est enregistré en tant que «d50». Dans le logiciel de la centrifugeuse à disque CPS, le diamètre de Stokes médian est indiqué comme «Médiane».
Note 3 à l'article: D est utilisé uniquement à des fins d'enregistrement.
3.2.4 mode
D mode valeur à laquelle le diamètre le plus fréquent est observé, représentée par un pic sur la courbe de distribution Note 1 à l'article: Dans certains cas, il peut y avoir plusieurs modes indiqués. Note 2 à l'article: Dans le logiciel de la centrifugeuse à disque CPS, le mode est indiqué en tant que «Pic». Note 3 à l'article: D est utilisé uniquement à des fins d'enregistrement. mode
3.2.5 quartile inférieur
zone de la courbe de distribution de masse dans laquelle 75 % de l'échantillon de noir est constitué de particules plus grosses et 25 % de particules plus fines
3.2.6 quartile supérieur
zone de la courbe de distribution de masse dans laquelle 75 % de l'échantillon de noir est constitué de particules plus fines et 25 % de particules plus grosses
3.2.7 rapport de quartile
rapport entre le quartile supérieur et le quartile inférieur Note 1 à l'article: Dans le logiciel de la centrifugeuse à disque Brookhaven, le rapport de quartile est enregistré en tant que «d75/d25».
3.2.8 ΔD-50
largeur de la courbe de distribution de masse mesurée à mi-hauteur du mode qui est une mesure de l'amplitude de la distribution dimensionnelle des agrégats Note 1 à l'article: Dans le logiciel de la centrifugeuse à disque Brookhaven, ΔD 50 est enregistré en tant que «FWHM» (pleine largeur à mi-hauteur). Dans le logiciel de la centrifugeuse à disque CPS, ΔD 50 est enregistré en tant que «Largeur à mi-hauteur».
4 Intérêt et utilisation
Cette méthode est fondée sur le comportement hydrodynamique du noir de carbone dans un champ centrifuge. La détermination de la distribution dimensionnelle des agrégats est importante dans l'évaluation du noir de carbone utilisé dans l'industrie du caoutchouc.
La méthode A est la méthode d'essai originale de la présente norme. La méthode B utilise un autre type d'instrument qui permet des séquences d'essai plus courtes.
ISO/FDIS 15825:2026(fr) La photosédimentométrie avec centrifugeuse à disque produit rapidement une distribution dimensionnelle des agrégats en fonction de leurs différences de masse, en mesurant en continu la turbidité de la solution en fonction de la durée de la centrifugation. Pour obtenir une distribution de masse vraie, un coefficient de correction pour la diffusion de la lumière doit être appliqué. Un exemple de courbe de distribution de masse est donné dans l’Annexe A.
5 Méthode A: Centrifugeuse à disque (DCP)
5.1 Principe
La centrifugeuse à disque sépare les particules en fonction de leur taille par sédimentation centrifuge dans un milieu liquide. Les particules sédimentent à l'intérieur d'un disque transparent en rotation, traversé par un faisceau lumineux. Lorsque les particules se déplacent vers le bord extérieur du disque, elles traversent le faisceau lumineux, dont elles atténuent l'intensité. L'atténuation du faisceau du détecteur est enregistrée en continu et convertie par le logiciel d'exploitation en masse de particules de chaque taille dans l'échantillon.
5.2 Appareillage
1)
5.2.1 Photosédimentomètre avec centrifugeuse à disque (DCP) , capable d’avoir des vitesses de
rotation de 1 000 r/min à 11 000 r/min ou supérieures, avec dispositif intégré de contrôle de la rotation 3 3 (exactitude et stabilité supérieures à ±0,05 %), volume du fluide de rotation compris entre 10 cm et 20 cm , température stable du fluide de rotation, stroboscope de contrôle du disque pour vérifier la stabilité et les anomalies d'écoulement, et un dispositif optique approprié de mesure de la turbidité approprié.
5.2.2 Compteur d'énergie, capable de mesurer la consommation d'énergie (en kWh) de l’émetteur
d'ultrasons de type sonde.
Le compteur d'énergie est inséré entre une prise électrique du laboratoire et la prise du cordon d'alimentation du sonificateur. La consommation d'énergie réelle est indiquée par un affichage numérique. 2)
5.2.3 Émetteur d'ultrasons de type sonde , typiquement avec une puissance nominale d’au moins
200 W.
Il convient que le sonificateur soit capable de fournir une consommation d'énergie mesurée d'au moins 60 W. Cette méthode s'est avérée efficace pour disperser le noir de carbone en agrégats distincts. Voir 5.5 pour plus de détails.
NOTE Des pointes de diamètre 12,7 mm (1/2 inch) se sont avérés appropriées.
5.2.4 Micro seringue, d'au plus 2 cm .
5.2.5 Seringue, d'au plus 20 cm .
5.3 Réactifs et matériaux
Sauf indication contraire, utiliser des réactifs de qualité analytique reconnue. 1) BI-DCP Particle Sizer est disponible auprès de Brookhaven Instruments Corporation, 750 Blue Point Rd., Holtsville, NY 11742, USA, www .b rookhaveni nstruments .com. L’instrument Joyce Loebl DCF 4 n’est plus disponible. Cette information est donnée à l'intention des utilisateurs du présent document et ne signifie nullement que l'ISO approuve ou recommande l'emploi exclusif des produits ainsi désignés.
2) Sonoplus 2220, équipé avec Sonotrode UW 2200 et horn DH 13 G, est disponible auprès de BANDELIN electronic GmbH & Co. KG, Heinrichstraße 3-4, D-12207 Berlin, www .bandelin .com. Il s’agit d’un exemple de produits appropriés disponibles sur le marché. Cette information est donnée à l'intention des utilisateurs du présent document et ne signifie nullement que l'ISO approuve ou recommande l'emploi exclusif des produits ainsi désignés.
ISO/FDIS 15825:2026(fr) 5.3.1 Eau, distillée ou déminéralisée, de grade 3 tel que défini dans l’ISO 3696. 3) 5.3.2 Ethanol, absolu, n° CAS 64-17-5.
4) 5.3.3 Surfactant, de type non-ionique , solutions de 0,02 % à 0,05 % (en masse). 5.3.4 Dodécane, de pureté ≥98 % (grade GC), n° CAS® 112-40-3.
5.3.5 Fluide de rotation, eau (5.3.1) contenant du surfactant (5.3.3) pouvant être ajustés de pH 9,0 à
pH 10,0 en utilisant 0,1 mol/dm NaOH.
3 3 5.3.6 Fluide de dispersion, une solution de 20 cm d’éthanol (5.3.2) et 80 cm d’eau (5.3.1) contenant un
surfactant (5.3.3). La solution peut être ajustée de pH 9,0 à pH 10,0 en utilisant 0,1 mol/dm NaOH.
5.4 Échantillonnage
Prélever des échantillons de noir de carbone, au hasard, dans des lots de grande dimension, sous forme granulée ou non granulée, conformément à l'ISO 1124. Étiqueter et conserver les échantillons en vue du stockage ou d'analyses ultérieures.
5.5 Étalonnage
5.5.1 Le mode opératoire suivant doit assurer que les agglomérats de noirs de carbone sont complètement dispersés en agrégats.
5.5.2 Préparer un échantillon d'ITRB (ou ITRB−2) suivant les instructions du 5.6. 5.5.3 Choisir l'énergie de sonification et le mode de sonification (par exemple mode pulsé) de façon à appliquer 0,005 kWh (18 kJ). Cela peut être typiquement obtenu par une puissance de 60 W et une durée de sonification de 5 min.
5.5.4 Démarrer la sonification et appuyer sur le bouton de démarrage du compteur d'énergie, qui est branché entre l’alimentation et le cordon d'alimentation de l’émetteur d'ultrasons. 5.5.5 Arrêter la sonification après 5 min, presser le bouton d’arrêt du compteur d’énergie et lire la consommation en énergie, exprimée en kWh.
5.5.6 Si l’ITRB ou l’ITRB−2 est entièrement dispersé, cela donnera un diamètre de Stokes moyen
(«moyenne») de 105 nm ± 5 nm (99 nm ± 5 nm pour l’ITRB−2).
5.5.7 Soumettre à essai l’ITRB ou l’ITRB−2 comme un noir de carbone normalisé sur une base régulière avant de soumettre à essai les échantillons réels.
5.5.8 Si la valeur de la norme est trop élevée, augmenter le temps et/ou la puissance de sonification ou changer les pointes du sonificateur.
NOTE Les pointes du sonificateur se détériorent avec le temps. 3) « CAS Registry Number® » est une marque déposée de l’American Chemical Society (ACS). Cette information est fournie pour la commodité des utilisateurs du présent document et ne constitue pas une approbation par l’ISO du produit mentionné. Des produits équivalents peuvent être utilisés s’il est démontré qu’ils conduisent aux mêmes résultats. 4) Nonidet P-40, de Shell Chemicals, convient pour cette application. Cette information est donnée à l'intention des utilisateurs du présent document et ne signifie nullement que l'ISO approuve ou recommande l'emploi exclusif du produit ainsi désigné. Tout autre type de surfactant non ionique peut être utilisé comme équivalent.
ISO/FDIS 15825:2026(fr)
5.6 Préparation de l’échantillon d’essai
5.6.1 Peser 20 mg de noir de carbone dans une coupelle de pesée. Si le logiciel ne peut pas traiter les valeurs de turbidité élevées, réduire la masse de l’échantillon.
5.6.2 Ajouter jusqu’à 20 cm du fluide de dispersion (5.3.6).
5.6.3 Disperser par ultrasons pendant la durée trouvée durant l’étalonnage (5.5), avec le récipient de dispersion immergé dans un liquide refroidissant tel que de l'eau glacée afin de minimiser l'effet de réchauffement libéré par l'énergie sonique durant la sonification. La température de l'échantillon d'essai doit être approximativement la même que la température ambiante, afin de réduire au minimum les gradients de température dans le disque.
La sonification des échantillons d'essai doit être prolongée si l'on observe un écoulement, ou si le dernier traitement par ultrasons remonte à plus de 1 h.
5.7 Réglage de l'équipement informatique et du logiciel
Saisir les paramètres appropriés, y compris les suivants:
a) Nom du dossier.
b) Identification de l'échantillon.
c) Température du fluide: saisir la température réelle, affichée par l'instrument après avoir lancé l'essai, pour le calcul.
d) Masse volumique et la viscosité du fluide: ne pas saisir un chiffre, mais choisir l'option «fluide de rotation = eau».
e) Vitesse du disque.
f) Choisir un coefficient de correction pour la diffusion de la lumière (correction Mie, noir de carbone).
...