Measurement of water flow in closed conduits — Tracer methods — Part 3: Constant rate injection method using radioactive tracers

Tracer methods apply to flow measurement in conduits into which a solution can be injected and those cases where effective mixing of this solution with the water flowing in the conduit can be achieved, this last condition being fundamental. Describes the method of constant injection rate using radioactive tracers.

Mesure de débit de l'eau dans les conduites fermées — Méthodes par traceurs — Partie 3: Méthode d'injection à débit constant, utilisant des traceurs radioactifs

Measurement of water flow in closed conduits - Tracer methods - Part III: Constant rate injection method using radioactive tracers

General Information

Status
Published
Publication Date
31-Jul-1976
Current Stage
9060 - Close of review
Start Date
04-Mar-2029

Buy Standard

Standard
ISO 2975-3:1997
English language
11 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day
Standard
ISO 2975-3:1976 - Measurement of water flow in closed conduits -- Tracer methods
English language
11 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 2975-3:1976 - Mesure de débit de l'eau dans les conduites fermées -- Méthodes par traceurs
French language
11 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 2975-3:1976 - Mesure de débit de l'eau dans les conduites fermées -- Méthodes par traceurs
French language
11 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

SLOVENSKI STANDARD
SIST ISO 2975-3:1997
01-september-1997
Measurement of water flow in closed conduits - Tracer methods - Part III: Constant
rate injection method using radioactive tracers
Measurement of water flow in closed conduits -- Tracer methods -- Part 3: Constant rate
injection method using radioactive tracers
Mesure de débit de l'eau dans les conduites fermées -- Méthodes par traceurs -- Partie
3: Méthode d'injection à débit constant, utilisant des traceurs radioactifs
Ta slovenski standard je istoveten z: ISO 2975-3:1976
ICS:
17.120.10 Pretok v zaprtih vodih Flow in closed conduits
SIST ISO 2975-3:1997 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST ISO 2975-3:1997

---------------------- Page: 2 ----------------------

SIST ISO 2975-3:1997
INTERNATIONAL STANDARD
2975/lll
INTERNATIONAL ORGANIZATION FOR STANDARDIZATION l MEXaYHAPOAHAII OPI-AHM3AUMfl l-IO CI’AH~APTM3ALWiM.QRGANISATION INTERNATIONALE DE NORMALISATION
Measurement of water flow in closed conduits -
Tracer methods -
Part Ill : Constant rate injection method using radioactive
tracers
Mesure de d&bit de l’eau dans les conduites fermees - IWthodes par traceurs -
Partie /lt : AMhode d’injection 4 d&bit constan t, utilisan t des traceurs radioactifs
First edition - 1976-08-15
UDC 681.121.84 Ref. No. ISO 2975/111-1976 (E)
Descriptors flow measurement, water flow, pipe flow, tracer method, radioactive isotopes, testing conditions, colorimetric analysis,
fluorimetric analysis, conductimetric analysis, error analysis.
Price based on 11 pages

---------------------- Page: 3 ----------------------

SIST ISO 2975-3:1997
REWORD
0 (the International Organization for Standardization) is a worldwide federation
national Standards institutes (ISO Member Bodies). The work of developing
International Standards is carried out through ISO Technical Committees. Every
ember Body interested in a subject for which a Technical Committee has been set
up has the right to be represented on that Committee. International organizations,
governmental and non-governmental, in liaison with ISO, also take part in the work.
Draft International Standards adopted by the Technical Committees are circulated
PO the Member Bodies for approval before their acceptance as International
tandards by the ISO Council.
h-rternational Standard ISO 2975/lll was drawn up by Technical Committee
ISO/TC 30, Measurement of fluid flow in closed conduits, and was circulated to
the Member Bodies in April 1975.
lt has been approved by the Member Bodies of the foliowing countries :
Australia
Italy Turkey
Belgium Netherlands
United Kingdom
Czechoslovakia Romania
U.S.S.R.
France Spain
Yugoslavia
Germany Switzerland
The Member Body of the foliowing country expressed disapproval of the document
on technical grounds :
U S.A.
~3 D nternational Organkation for Standardkation, 1976 l
Printed in Switzerland

---------------------- Page: 4 ----------------------

SIST ISO 2975-3:1997
INTERNATIONAL STANDARD ISO 2975/lll-1976 (E)
Measurement of water flow in closed conduits -
Tracer methods -
Part Hl : Constant rate injection method using radioactive
tracers
6 INTRODUCTIION
The tracer rate at the injection Point is equal to the rate at
which it Passes the sampiing Point :
This International Standard is the third of a series of
Standards covering tracer methods of water flow measure-
qc, +clc,= K=q)C2
ment in closed conduits. The complete series of Standards
Where Cc is the initial concentration in the stream which
will be as foliows :
is flowing at the rate Q.
- Part I : Genera/.
Hence :
- Part I I : Constant rate injection method using non-
Cl -c2
Q=q
radioac tive tracers.
. 0 . 0)
c2 -Co
- Part I I l : Konstant rate injection method using radio-
Generaily C1 is much greater than C2 which leads to a
ac tive tracers.
simpiification of equation (1) as foliows :
- Part IV : ln tegra tion (sudden injec tion) me thod
Cl
Q=q---
using non -radioae tive tracers.
c2 - Co
- Part V : Integration (sudden injection) method using
When C2 is much greater than Co, the equation tan be
radioac tive tracers.
reduced still further to
- Part VI : Transit time method using non-radioactive
Cl
tracers.
Q=q-
c2
- Part VII : Transit time me thod using radioac tive
Flow rate Q tan thus be determined by comparing the
tracers.
concentration of the injected Solution with the concen-
tration of samples removed from the conduit.
1 SCOPE AND FIELD Oß APPLICATION
This International Standard specifies the constant rate
3 REQUIRED CONDITIONS
injection method using radioactive tracers for the measure-
ment of water fiow rate in closed conduits.
3.1 Tracer
For the constant rate injection method the tracer shail meet
2 PRINCIPLE
the general requirements defined in 5.1 of part 1. A list of
generally used tracers is
...

INTERNATIONAL STANDARD
2975/lll
INTERNATIONAL ORGANIZATION FOR STANDARDIZATION l MEXaYHAPOAHAII OPI-AHM3AUMfl l-IO CI’AH~APTM3ALWiM.QRGANISATION INTERNATIONALE DE NORMALISATION
Measurement of water flow in closed conduits -
Tracer methods -
Part Ill : Constant rate injection method using radioactive
tracers
Mesure de d&bit de l’eau dans les conduites fermees - IWthodes par traceurs -
Partie /lt : AMhode d’injection 4 d&bit constan t, utilisan t des traceurs radioactifs
First edition - 1976-08-15
UDC 681.121.84 Ref. No. ISO 2975/111-1976 (E)
Descriptors flow measurement, water flow, pipe flow, tracer method, radioactive isotopes, testing conditions, colorimetric analysis,
fluorimetric analysis, conductimetric analysis, error analysis.
Price based on 11 pages

---------------------- Page: 1 ----------------------
REWORD
0 (the International Organization for Standardization) is a worldwide federation
national Standards institutes (ISO Member Bodies). The work of developing
International Standards is carried out through ISO Technical Committees. Every
ember Body interested in a subject for which a Technical Committee has been set
up has the right to be represented on that Committee. International organizations,
governmental and non-governmental, in liaison with ISO, also take part in the work.
Draft International Standards adopted by the Technical Committees are circulated
PO the Member Bodies for approval before their acceptance as International
tandards by the ISO Council.
h-rternational Standard ISO 2975/lll was drawn up by Technical Committee
ISO/TC 30, Measurement of fluid flow in closed conduits, and was circulated to
the Member Bodies in April 1975.
lt has been approved by the Member Bodies of the foliowing countries :
Australia
Italy Turkey
Belgium Netherlands
United Kingdom
Czechoslovakia Romania
U.S.S.R.
France Spain
Yugoslavia
Germany Switzerland
The Member Body of the foliowing country expressed disapproval of the document
on technical grounds :
U S.A.
~3 D nternational Organkation for Standardkation, 1976 l
Printed in Switzerland

---------------------- Page: 2 ----------------------
INTERNATIONAL STANDARD ISO 2975/lll-1976 (E)
Measurement of water flow in closed conduits -
Tracer methods -
Part Hl : Constant rate injection method using radioactive
tracers
6 INTRODUCTIION
The tracer rate at the injection Point is equal to the rate at
which it Passes the sampiing Point :
This International Standard is the third of a series of
Standards covering tracer methods of water flow measure-
qc, +clc,= K=q)C2
ment in closed conduits. The complete series of Standards
Where Cc is the initial concentration in the stream which
will be as foliows :
is flowing at the rate Q.
- Part I : Genera/.
Hence :
- Part I I : Constant rate injection method using non-
Cl -c2
Q=q
radioac tive tracers.
. 0 . 0)
c2 -Co
- Part I I l : Konstant rate injection method using radio-
Generaily C1 is much greater than C2 which leads to a
ac tive tracers.
simpiification of equation (1) as foliows :
- Part IV : ln tegra tion (sudden injec tion) me thod
Cl
Q=q---
using non -radioae tive tracers.
c2 - Co
- Part V : Integration (sudden injection) method using
When C2 is much greater than Co, the equation tan be
radioac tive tracers.
reduced still further to
- Part VI : Transit time method using non-radioactive
Cl
tracers.
Q=q-
c2
- Part VII : Transit time me thod using radioac tive
Flow rate Q tan thus be determined by comparing the
tracers.
concentration of the injected Solution with the concen-
tration of samples removed from the conduit.
1 SCOPE AND FIELD Oß APPLICATION
This International Standard specifies the constant rate
3 REQUIRED CONDITIONS
injection method using radioactive tracers for the measure-
ment of water fiow rate in closed conduits.
3.1 Tracer
For the constant rate injection method the tracer shail meet
2 PRINCIPLE
the general requirements defined in 5.1 of part 1. A list of
generally used tracers is given in 5.1.2 of part l and their
Flow rate measurement by a constant rate injection method
advantages with respect to non-radioactive tracers are stated
is based on a comparison between the concentration C, of
in 5.2.1 .l and 5.2J.2.
a tracer continuously introduced with a known volume
rate of flow g, and the concentration of samples C2 taken
at some place beyond the distancel 1. The mixing distance
3.2 Duration of injection
is defined as the shortest distance at which the Variation in
concentration of the tracer over the Cross-section is less The duration of injection shail be such that stable concen-
than some pre-determined value (for example 0,5 % ). (See tration conditions are established at all Points of the
clause 6 of part I .) measuring Cross-section over a sufficient period of time.
1) Another method tan be contemplated which would not involve sampling.

---------------------- Page: 3 ----------------
...

NORME INTERNATIONALE
29751111
INTERNATIONAL ORGANIZATION FOR STANDARDIZATION l MF.-X,IYIiAPWlHAII OPT’AHH3ALlMR 110 CTAHJIAPTll3AUMW O~RGANISATION INTERNATIONALE DE NORMALlSATlON
Mesure de débit de l’eau dans les conduites fermées -
Méthodes par traceurs -
Partie Ill : Méthode d’injection à débit constant, utilisant des
traceurs radioactifs
Measurement of water flow in closed conduits - Tracer methods -
Part I/l : Constant rate injection method using radioactive tracers
Première édition - 1976-08-15
c
-
CDU 681.121.84 Réf. no : ISO 2975/111-1976 (F)
Descripteurs : mesurage de débit, écoulement en conduite fermée, écoulement d’eau, méthode par traceur, isotope radioactif, conditions
d’essai, méthode calorimétrique, méthode fluorimétrique, méthode conductimétrique, calcul d’erreur.
h
Prix basé sur 11 pages

---------------------- Page: 1 ----------------------
AVANT-PROPOS
L’ISO (Organisation Internationale de Normalisation) est une fédération mondiale
d’organismes nationaux de normalisation (Comités Membres 60). L’élaboration des
Normes Internationales est confiée aux Comités Techniques ISO. Chaque Comité
Membre intéressé par une étude a le droit de faire partie du Comité Technique
correspondant. Les organisations internationales, gouvernementales et non
gouvernementales, en liaison avec I’ISO, participent également aux travaux.
Les Projets de Normes Internationales adoptés par les Comités Techniques sont
soumis aux Comités Membres pour approbation, avant leur acceptation comme
Normes Internationales par le Conseil de I’ISO.
La Norme Internationale ISO 2975hll a été établie par le Comité Technique
ISO/TC 30, Mesure de débit des fluides dans les conduites fermées, et a été soumise
aux Comités Membres en avril 1975.
Elle a été approuvée par les Comités Membres des pays suivants :
4talie
Allemagne Tchécoslovaquie
Australie Pays-Bas Turquie
Belgique Roumanie U.R.S.S.
Espagne Royaume-Uni Yougoslavie
France Suisse
Le Comité Membre du pays suivant a désapprouvé le document pour des raisons
techniques :
U.S.A.
0 Organisation Internationale de Normalisation, 1976 l
Imprimé en Suisse

---------------------- Page: 2 ----------------------
NORME INTERNATIONALE ls0 2975/lll-1976 (F)
Mesure de débit de l’eau dans les conduites fermées -
Méthodes par traceurs -
Partie Ill : Méthode d’injection à débit constant, utilisant des
traceurs radioactifs
0 INTRODUCTION
Le débit du traceur au point d’injection est égal à celui qui
traverse le point d’échantillonnage :
La présente Norme Internationale est la troisième d’une
série de normes traitant de la mesure de débit de l’eau dans
q C, + Q CO = (Q + q) C2
les conduites fermées utilisant les méthodes par traceurs.
où Co est la concentration initiale dans le courant de
La série complète des normes sera la suivante :
débit Q
- Partie I : Générahtés.
d’où
- Partie II : Méthode d’injection à débit constant,
Cl - c2
Q=q-
utilisant des traceurs non radioactifs.
c2 L CO
l . .
(1)
- Partie Ill : Méthode d’injection à débit constant,
En général, CI est beaucoup plus grand que C2, ce qui
utilisant des traceurs radioac?ifs.
conduit à simplifier l’équation (1) comme suit :
- Partie IV : Méthode d’intégration (injection instan-
Cl
tanée), utilisant des traceurs non radioactifs.
Q=q-
c2 - CO
(injection ins tan-
- Partie V : Méthode d *in tégra tion
Lorsque C2 est par ailleurs beaucoup plus grand que CO, on
tanée), utilisant des traceurs radioactifs.
peut encore réduire cette équation, qui devient alors :
- Partie VI : Méthode des temps de transit, utilisant
des traceurs non radioactifs.
- Partie VII : Méthode des temps de transit, utilisant
des traceurs radioactifs. Le débit Q peut donc être déterminé par comparaison entre
la concentration de la solution injectée et celle des échan-
tillons prélevés dans la conduite.
1 OBJET ET DOMAINE D’APPLICATION
La présente Norme Internationale spécifie la méthode
d’injection à débit constant, utilisant des traceurs radio- 3 CONDITIONS REQUISES
actifs, pour la mesure de débit de l’eau dans les conduites
fermées.
3.1 Traceur
Pour l’utilisation de la méthode d’injection à débit cons-
2 PRINCIPE
tant, le traceur doit satisfaire aux conditions générales
définies dans le paragraphe 5.1 de la partie 1. Une liste de
La mesure du débit par la méthode d’injection à débit
traceurs généralement utilisés est donnée au paragraphe
constant se fonde sur une comparaison entre la concen-
5.1.2 de la partie 1; leurs avantages par rapport aux traceurs
tration CI d’un traceur, introduit en continu avec un
non radioactifs sont indiqués aux paragraphes 5.2.1 .l et
débit-volume connu 9 et la concentration des échantillons
5.2.1.2 de la partie 1.
C2 prélevés en un endroit déterminé situé au-delà de la
distance de bon mélange1 1. Cette distance de bon mélange
3.2 Durée de l’injection
se définit comme la distance minimale au niveau de laquelle
la variation en concentratio
...

NORME INTERNATIONALE
29751111
INTERNATIONAL ORGANIZATION FOR STANDARDIZATION l MF.-X,IYIiAPWlHAII OPT’AHH3ALlMR 110 CTAHJIAPTll3AUMW O~RGANISATION INTERNATIONALE DE NORMALlSATlON
Mesure de débit de l’eau dans les conduites fermées -
Méthodes par traceurs -
Partie Ill : Méthode d’injection à débit constant, utilisant des
traceurs radioactifs
Measurement of water flow in closed conduits - Tracer methods -
Part I/l : Constant rate injection method using radioactive tracers
Première édition - 1976-08-15
c
-
CDU 681.121.84 Réf. no : ISO 2975/111-1976 (F)
iz
P
Descripteurs : mesurage de débit, écoulement en conduite fermée, écoulement d’eau, méthode par traceur, isotope radioactif, conditions
d’essai, méthode calorimétrique, méthode fluorimétrique, méthode conductimétrique, calcul d’erreur.
Prix basé sur 11 pages

---------------------- Page: 1 ----------------------
AVANT-PROPOS
L’ISO (Organisation Internationale de Normalisation) est une fédération mondiale
d’organismes nationaux de normalisation (Comités Membres 60). L’élaboration des
Normes Internationales est confiée aux Comités Techniques ISO. Chaque Comité
Membre intéressé par une étude a le droit de faire partie du Comité Technique
correspondant. Les organisations internationales, gouvernementales et non
gouvernementales, en liaison avec I’ISO, participent également aux travaux.
Les Projets de Normes Internationales adoptés par les Comités Techniques sont
soumis aux Comités Membres pour approbation, avant leur acceptation comme
Normes Internationales par le Conseil de I’ISO.
La Norme Internationale ISO 2975hll a été établie par le Comité Technique
ISOITC 30, Mesure de débit des fluides dans les conduites femées, et a été soumise
aux Comités Membres en avril 1975.
Elle a été approuvée par les Comités Membres des pays suivants :
Allemagne 4talie Tchécoslovaquie
Australie Pays-Bas Turquie
Belgique Roumanie U.R.S.S.
Espagne Royaume-Uni Yougoslavie
Suisse
France
du suivant a désapprouvé le document des raisons
Le Comité Membre pour
PW
techniques
U.S.A.
0 Organisation Internationale de Normalisation, 1976 l
Imprimé en Suisse

---------------------- Page: 2 ----------------------
NORME INTERNATIONALE 1st) 2975/lll-1976 (F)
Mesure de débit de l’eau dans les conduites fermées -
Méthodes par traceurs -
Partie Ill : Méthode d’injection à débit constant, utilisant des
traceurs radioactifs
0 INTRODUCTION
Le débit du traceur au point d’injection est égal à celui qui
traverse le point d’échantillonnage :
La présente Norme Internationale est la troisième d’une
série de normes traitant de la mesure de débit de l’eau dans
q C, + Q CO = (Q + q) C2
les conduites fermées utilisant les méthodes par traceurs.
où CO est la concentration initiale dans le courant de
La série complète des normes sera la suivante :
débit Q
- Partie I : Généraktés.
d’où
- Partie II : Méthode d’injection à débit constant,
Cl - c2
Q=q-
utilisant des traceurs non radioactifs.
c2 L CO
. . .
(1)
- Partie Ill : Méthode d’injection à débit constant,
En général, CI est beaucoup plus grand que C2, ce qui
utilisant des traceurs radioac?ifs.
conduit à simplifier l’équation (1) comme suit :
- Partie IV : Méthode d’in tégra tion (in jet tion ins tan-
Cl
tanée), utilisant des traceurs non radioactifs.
Q=q-
c2 - CO
- Partie V : Méthode d *in tégra tion (in jet tion ins tan-
Lorsque C2 est par ailleurs beaucoup plus grand que CO, on
tanée), utilisant des traceurs radioactifs.
peut encore réduire cette équation, qui devient alors :
- Partie VI : Méthode des temps de transit, utilisant
Cl
des traceurs non radioactifs.
Q=qT
- Partie VII : Méthode des temps de transit, utilisant
des traceurs radioactifs. Le débit Q peut donc être déterminé par comparaison entre
la concentration de la solution injectée et celle des échan-
tillons prélevés dans la conduite.
1 OBJET ET DOMAINE D’APPLICATION
La présente Norme Internationale spécifie la méthode
d’injection à débit constant, utilisant des traceurs radio-
actifs, pour la mesure de débit de l’eau dans les conduites
fermées.
3.1 Traceur
Pour l’utilisation de la méthode d’injection à débit cons-
2 PRINCIPE
tant, le traceur doit satisfaire aux conditions générales
définies dans le paragraphe 5.1 de la partie 1. Une liste de
La mesure du débit par la méthode d’injection à débit
traceurs généralement utilisés est donnée au paragraphe
constant se fonde sur une comparaison entre la concen-
5.1.2 de la partie 1; leurs avantages par rapport aux traceurs
tration CI d’un traceur, introduit en continu avec un
non radioactifs sont indiqués aux paragraphes 5.2.1 .l et
débit-volume connu 9 et la concentration des échantillons
5.2.1.2 de la partie 1.
C2 prélevés en un endroit déterminé situé au-delà de la
1). Cette distance de bon mélange
distance de bon mélange
3.2 Durée de l’injection
se définit comme la distance minimale au niveau de laquelle
la variation en concentration d
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.