Abstract

ISO 17561:2016 describes the method of test for determining the dynamic elastic moduli of fine ceramics at room temperature by sonic resonance. It is for fine ceramics that are elastic, homogeneous and isotropic.[2]

Status
Not Published
Technical Committee
ISO/TC 206 - Fine ceramics
Current Stage
6000 - International Standard under publication - 60 Publication
Start Date
30-Oct-2026

Buy Documents

Draft

ISO/PRF 17561 - Fine ceramics (advanced ceramics, advanced technical ceramics) — Test methods for dynamic elastic moduli of monolithic ceramics at room temperature by sonic resonance and impulse excitation technique (IET)

Release Date:01-Oct-2026
English language (27 pages)
sale 15% off
sale 15% off
Draft

REDLINE ISO/PRF 17561 - Fine ceramics (advanced ceramics, advanced technical ceramics) — Test methods for dynamic elastic moduli of monolithic ceramics at room temperature by sonic resonance and impulse excitation technique (IET)

Release Date:01-Oct-2026
English language (27 pages)
sale 15% off
sale 15% off

ISO 17561 is an International Standard from ISO for measuring the dynamic elastic moduli of fine ceramics, also called advanced ceramics or advanced technical ceramics, at room temperature. It covers two vibration-based test methods - sonic resonance and impulse excitation technique (IET) - for determining Young’s modulus, shear modulus and Poisson’s ratio from a ceramic test piece’s dimensions, mass and measured natural frequencies.

What does ISO 17561 specify?

ISO 17561 specifies room-temperature test methods for monolithic fine ceramics that behave as elastic, homogeneous, isotropic materials. The standard gives one method based on forced resonance and one based on impact excitation, and it ties both methods to the same property outputs so results can be compared in practice.

The document is organized into Scope, Normative references, Terms and definitions, Method A, Method B, and Report. It also includes two informative annexes: one for disc-shaped test pieces and one for round-robin validation.

AnnexWhat it covers
Annex AImpact excitation method applied to disc test pieces
Annex BRound-robin validation of the test methods

What are the key requirements of ISO 17561?

ISO 17561 focuses on specimen suitability, controlled geometry, accurate frequency measurement, and clear reporting. Those points matter because the calculated moduli depend directly on resonance frequency, mass, and dimensions, so small setup errors can distort the result.

  • Specimen condition and material behavior - ISO 17561 requires test pieces to be free of major discontinuities such as large cracks or internal voids, with grain size below 10% of the minimum dimension. The methods assume homogeneous, isotropic and linear elastic behavior, so porous or anisotropic materials can give unreliable results or misleading Poisson’s ratio values.

  • Specimen geometry - ISO 17561 uses slender rectangular prisms or cylindrical rods for both Method A and Method B. In practice, the piece must be long enough for clear flexural or torsional vibration, with aspect ratios high enough to avoid mixed modes, and the frequency range must fall within the stated resonance window.

  • Surface finish and end condition - ISO 17561 calls for smooth, flat surfaces finished by fine grinding, with edges normally left unchamfered unless chipping makes chamfering necessary. This matters because face parallelism and edge condition affect the frequency and therefore the modulus calculation.

  • Instrumentation for Method A - ISO 17561 sets performance expectations for the oscillator, amplifier, driver, detector, frequency counter, support method, micrometer, calliper, balance, oven and desiccator. The frequency chain has to be stable and precise enough to resolve resonance clearly, because the method relies on identifying the fundamental flexural or torsional peak.

  • Instrumentation for Method B - ISO 17561 expects a transducer, amplifier and frequency analyser, with the analyser checked against a reference frequency source or equivalent means. This keeps the impulse method anchored to traceable frequency measurement, which is essential when the specimen is struck lightly and the response is captured electronically.

  • Measurement procedure - ISO 17561 requires drying at 110 °C ± 10 °C to constant mass, cooling in a desiccator, weighing, and measuring thickness, width or diameter at three positions along the length. The resonance or natural frequency is then measured repeatedly - at least five times - to confirm repeatability and to verify that the fundamental mode has been found.

  • Support and excitation positions - ISO 17561 specifies node-based support positions for both flexural and torsional modes. For flexural vibration, the support points are placed near the nodes at about 0.224 of the length from each end; for torsional vibration, the support arrangement changes accordingly. In practice, correct positioning avoids damping or shifting the resonance.

  • Calculation and uncertainty - ISO 17561 gives calculation routes for Young’s modulus, shear modulus and Poisson’s ratio for rectangular prisms and circular rods. It also notes that dimensional regularity, especially thickness in flexural testing, is a main source of uncertainty, and that anisotropy should be flagged in the report when suspected.

What terms does ISO 17561 define?

  • Dynamic elastic moduli - Elastic moduli determined non-quasistatically, under quasi-adiabatic conditions, using methods such as sonic resonance and IET.

  • Young’s modulus (E) - The stress needed to produce unit strain in uniaxial extension or compression.

  • Shear modulus (G) - The shear stress needed to produce unit angular distortion.

  • Poisson’s ratio - The ratio of transverse strain to axial strain under uniform axial stress below the proportional limit.

  • Flexural vibration - Vibration in a bending mode, visible when a slender beam oscillates in a plane normal to its length.

  • Torsional vibration - Vibration in a twisting mode, where each cross-section rotates around the length axis.

  • Resonance - The state in which a driven specimen reaches maximum displacement for a given driving force.

  • Node - A point in the vibrating shape where displacement is zero.

Who uses ISO 17561?

ISO 17561 is used by testing laboratories, ceramic manufacturers, quality control teams, and materials engineers who need room-temperature elastic-property data for fine ceramics. It is also relevant to buyers and technical specifiers who compare materials on stiffness, shear response, and Poisson’s ratio, and to laboratories working under ISO/IEC 17025.

What changed in ISO 17561 from the previous edition?

ISO 17561:2026 replaces ISO 17561:2016 and was technically revised. The stated changes are:

  • addition of Method B - Impulse excitation technique
  • revised formulae for the dynamic shear modulus of a rectangular prism
  • addition of informative Annex A for disc-shaped test pieces
  • addition of informative Annex B with round-robin results comparing four methods

Which standards are used with ISO 17561?

  • ISO 3611 - Provides requirements for micrometers used to measure thickness, width and diameter.
  • ISO 13383-1 - Provides the grain-size method used to check whether the ceramic microstructure is fine enough for the test piece size.
  • ISO 13385-1 - Provides requirements for vernier callipers used to measure specimen length.
  • ISO/IEC 17025 - Sets the laboratory competence and reporting framework used for the test report.

What does the ISO 17561 document contain?

ISO 17561 contains two full test methods, each with principle, apparatus, test pieces, procedure, calculations and measurement uncertainty. Clause 4 covers sonic resonance with apparatus examples shown in figures and example specimen sizes and resonant frequencies in a table, while Clause 5 covers the impulse excitation method with its own setup and calculation route.

Annex A extends Method B to disc test pieces and adds a dedicated principle, method, interference notes, uncertainty discussion, report items, and look-up tables for Poisson’s ratio and geometric constants. Annex B summarizes a European round-robin and gives comparative results for several ceramic materials and test methods, which helps users judge repeatability and reproducibility before applying the standard in routine testing.

Relations

Effective Date
18-Nov-2023

Buy Documents

Draft

ISO/PRF 17561 - Fine ceramics (advanced ceramics, advanced technical ceramics) — Test methods for dynamic elastic moduli of monolithic ceramics at room temperature by sonic resonance and impulse excitation technique (IET)

Release Date:01-Oct-2026
English language (27 pages)
sale 15% off
sale 15% off
Draft

REDLINE ISO/PRF 17561 - Fine ceramics (advanced ceramics, advanced technical ceramics) — Test methods for dynamic elastic moduli of monolithic ceramics at room temperature by sonic resonance and impulse excitation technique (IET)

Release Date:01-Oct-2026
English language (27 pages)
sale 15% off
sale 15% off

Frequently Asked Questions

ISO 17561 is a draft published by the International Organization for Standardization (ISO). Its full title is "Fine ceramics (advanced ceramics, advanced technical ceramics) — Test methods for dynamic elastic moduli of monolithic ceramics at room temperature by sonic resonance and impulse excitation technique (IET)". This standard covers: ISO 17561:2016 describes the method of test for determining the dynamic elastic moduli of fine ceramics at room temperature by sonic resonance. It is for fine ceramics that are elastic, homogeneous and isotropic.[2]

ISO 17561:2016 describes the method of test for determining the dynamic elastic moduli of fine ceramics at room temperature by sonic resonance. It is for fine ceramics that are elastic, homogeneous and isotropic.[2]

ISO 17561 is classified under the following ICS (International Classification for Standards) categories: 81.060.30 - Advanced ceramics. The ICS classification helps identify the subject area and facilitates finding related standards.

ISO 17561 has the following relationships with other standards: It is inter standard links to ISO 17561:2016. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

ISO 17561 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 3.1 dynamic elastic moduli
  • 3.2 Young’s modulus
  • 3.3 shear modulus
  • 3.4 Poisson's ratio
  • 3.5 flexural vibration
  • 3.6 torsional vibration
  • 3.7 resonance
  • 3.8 fundamental frequency
  • 3.9 node
  • 4 Method A: Sonic Resonance
  • 4.1 Principle
  • 4.2 Apparatus
  • 4.3 Test pieces
  • 4.4 Test procedure
  • 4.5 Calculations
  • 4.6 Measurement uncertainty
  • 5 Method B: Impulse excitation method
  • 5.1 Principle
  • 5.2 Apparatus
  • 5.3 Test pieces
  • 5.4 Procedure
  • 5.5 Calculations
  • 5.6 Measurement uncertainty
  • 6 Report
  • 6.1 General
  • 6.2 Method A
  • 6.3 Method B
  • Annex A
  • Annex B
  • Bibliography

1 Scope

This document specifies test methods for determining the dynamic elastic moduli, specifically Young’s modulus, shear modulus and Poisson’s ratio, of fine ceramics at room temperature. This document specifies two alternative methods:

a) method A - determination of moduli by forced sonic resonance of a slender beam; b) method b - determination of moduli from the fundamental natural frequencies of a struck slender beam (impulse excitation technique - IET).

[3] Both test methods assume the use of test pieces of homogeneous, isotropic and linear elastic materials . NOTE 1 Not all ceramic materials are equally and linearly elastic in tension and compression, such as some porous materials, and some piezoelectric materials.

NOTE 2 At high porosity levels, these methods can become inappropriate. NOTE 3 The merits of the two methods described in the present document have been addressed in a European round-robin comparing four methods for the determination of the elastic moduli of monolithic ceramics at room temperature. The results of this exercise are provided in the informative Annex B (see also reference [3]).

2 Normative references

The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 3611, Geometrical product specifications (GPS) — Dimensional measuring equipment — Design and metrological characteristics of micrometers for external measurements ISO 13383-1, Fine ceramics (advanced ceramics, advanced technical ceramics) — Microstructural characterization — Part 1: Determination of grain size and size distribution ISO 13385-1, Geometrical product specifications (GPS) — Dimensional measuring equipment — Part 1: Design and metrological characteristics of callipers ISO/IEC 17025, General requirements for the competence of testing and calibration laboratories

3 Terms and definitions

For the purposes of this document, the following terms and definitions apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:

  • ISO Online browsing platform: available at https:// www .iso .org/ obp
  • IEC Electropedia: available at https:// www .electropedia .org/ PROOF/ÉPREUVE

ISO 17561:2026(en)

3.1 dynamic elastic moduli

elastic moduli determined non-quasistatically, i.e. under quasi-adiabatic conditions, such as in the sonic resonance and impulse excitation methods

3.2 Young’s modulus

E stress required in a material to produce unit strain in uniaxial extension or compression E / where E is Young’s modulus in pascals (Pa); σ is the tension or compression stress in pascals (Pa); ε is the tension or compression strain.

3.3 shear modulus

G shear stress required in a material to produce unit angular distortion G / where G is the shear modulus in pascals (Pa); τ is the shear or torsional stress in pascals (Pa); γ is the shear or torsional strain.

3.4 Poisson's ratio

ν ratio of transverse strain to the corresponding axial strain resulting from uniformly distributed axial stress below the proportional limit of the material Note 1 to entry: In isotropic materials, Young’s modulus (E), shear modulus (G) and Poisson's ratio (ν) are related by the following formula:

vE / 21G 

3.5 flexural vibration

vibration in a flexural mode vibration apparent when the oscillation in a slender beam is in plane normal to the length dimension

3.6 torsional vibration

vibration in a torsional mode vibration apparent when the oscillation in each cross-section plane of a slender bar is such that the plane twists around the length dimension axis

3.7 resonance

state in which, when a slender bar is driven into a flexural or torsional mode of vibration, the imposed frequency is such that the resultant displacements for a given amount of driving force are at a maximum Note 1 to entry: The resonant frequencies are natural vibration frequencies which are determined by the elastic modulus, mass and dimensions of the test piece.

PROOF/ÉPREUVE

ISO 17561:2026(en)

3.8 fundamental frequency

lowest frequency of a periodic waveform

3.9 node

location in a vibrating shape where the displacement is zero for a given frequency of vibration Note 1 to entry: For the fundamental flexural resonance in a slender beam, the nodes are located at 0,224 L from each end, where L is the length of the bar.

4 Method A: Sonic Resonance

4.1 Principle

This test method measures the flexural or torsional frequencies of test specimens of a slender rectangular prism or cylindrical rod by exciting them at continuously variable frequencies. Mechanical excitation of the specimens is provided through the use of a transducer that transforms a cyclic electrical signal into a cyclic mechanical force on the test piece. A second transducer senses the resulting mechanical vibrations of the test piece and transforms them into an electrical signal. The amplitude and the frequency of the signal are measured by an oscilloscope or other means to detect resonance. The peak response is obtained at the resonant frequency. The fundamental resonant frequencies, dimensions and mass of the specimen are used to calculate the dynamic elastic moduli. The Young’s modulus is determined from the flexural resonance frequency, and the shear modulus is determined from the torsional resonance frequency, together with the test piece dimensions and mass. Poisson's ratio is determined from the Young’s modulus and the shear modulus.

4.2 Apparatus

4.2.1 General

There are various techniques that may be used to determine the resonant frequency of the test piece. The test piece can be excited by direct mechanical contact of a vibrator, or it can be suspended by a wire from a vibrator. It can be driven electromagnetically by attaching thin foils of magnetic material to one surface, or electrostatically by attaching an electrode to, or painting a conducting film of metal or graphite on, one surface.

One example of the test apparatus is shown in Figure 1. The driving circuit consists of an oscillator, an amplifier, a driver and a frequency counter. The detecting circuit consists of a detector, an amplifier and an oscilloscope. Figure 1 shows the suspension style of the apparatus. The direct contact support style of the test apparatus, shown in Figure 2, is also possible. It consists of a variable-frequency audio oscillator, used to generate a sinusoidal voltage, and a power amplifier and suitable transducer to convert the electrical signal to a mechanical driving vibration. A frequency meter (preferably digital) monitors the audio oscillator output to provide accurate frequency determination. A suitable suspension coupling system supports the test piece. A transducer detector acts to detect mechanical vibration in the specimen and to convert it into an electrical signal which is passed through an amplifier and displayed on an indicating meter. The meter may be a voltmeter, a microammeter or an oscilloscope. An oscilloscope is recommended because it enables the operator to positively identify resonances, including higher order harmonics, by Lissajous figure analysis, which is a superposition of two perpendicular harmonics. If a Lissajous figure is desired, the output of the oscillator is also coupled to the horizontal plates of the oscilloscope. PROOF/ÉPREUVE

ISO 17561:2026(en) Key 1 frequency counter 2 oscillator 3 amplifier 4 driver 5 oscilloscope 6 detector 7 suspending string Figure 1 — Example of the test apparatus and the suspension for fundamental flexural resonance Key 1 driving 2 detecting 3 flexural Figure 2 — Example of the direct contact support of the test piece for fundamental flexural resonance PROOF/ÉPREUVE

ISO 17561:2026(en)

4.2.2 Oscillator

The oscillator shall be able to vary the frequency from 100 Hz to at least 30 kHz, with a frequency resolution of 1 Hz and a maximum frequency drift of 1 Hz/min.

4.2.3 Amplifier

The audio amplifier shall have a power output sufficient to ensure that the type of transducer used can excite any specimen, the mass of which falls within a specified range. A power amplifier in the detector circuit shall be impedance-matched with the type of detector transducer selected and shall serve as a prescope amplifier.

4.2.4 Driver

The driver shall be able to convert electrical vibration to mechanical vibration. The frequency response of the driver transducer across the frequency range of interest shall have at least a 6,5 kHz bandwidth before −3 dB power loss occurs.

NOTE For flexibility in testing, the bandwidth can, with advantage, be at least as large as the frequency range given in Table 1.

4.2.5 Detector

The detector shall generate a voltage proportional to the amplitude, velocity or acceleration of the mechanical vibration of the specimen. The frequency response of the detector across the frequency range of interest shall have at least a 6,5 kHz bandwidth before a −3 dB power loss occurs. NOTE For flexibility in testing, the bandwidth can, with advantage, be at least as large as the frequency range given in Table 1.

Table 1 — Examples of the test piece size and calculated resonant frequencies

When the density = 3 g/cm E = 200 GPa E = 300 GPa E = 400 GPa L × b × t ν = 0,25 ν = 0,25 ν = 0,25 f = 12 255 Hz 15 010 Hz 17 332 Hz f 45 x 4 x 3 f = 50 756 Hz 62 163 Hz 71 780 Hz t f = 4 453 Hz 5 453 Hz 6 297 Hz f 75 × 15 × 3 f = 12 699 Hz 15 553 Hz 17 959 Hz t f = 1 676 Hz 2 053 Hz 2 371 Hz f 100 × 20 × 2 f = 5 014 Hz 6 141 Hz 7 091 Hz t f = 2 977 Hz 3 646 Hz 4 210 Hz f 75 × 20 × 2 f = 6 715 Hz 8 224 Hz 9 496 Hz t

When the density = 6 g/cm E = 200 GPa E = 300 GPa E = 400 GPa L × b × t ν = 0,25 ν = 0,25 ν = 0,25 f = 8 666 Hz 10 613 Hz 12 255 Hz f 45 x 4 x 3 f = 35 890 Hz 43 956 Hz 50 756 Hz t Key L is the length in millimetres (mm); b is the width in millimetres (mm); t is the thickness in millimetres (mm); f is the fundamental flexural resonant frequency in Hertz (Hz); f f is the fundamental torsional resonant frequency in Hertz (Hz). t PROOF/ÉPREUVE

ISO 17561:2026(en) TTabablele 1 1 ((ccoonnttiinnueuedd)) f = 3 148 Hz 3 856 Hz 4 453 Hz f 75 × 15 × 3 f = 8 979 Hz 10 998 Hz 12 699 Hz t f = 1 185 Hz 1 452 Hz 1 676 Hz f 100 × 20 × 2 f = 3 546 Hz 4 342 Hz 5 014 Hz t f = 2 105 Hz 2 578 Hz 2 977 Hz f 75 × 20 × 2 f = 4 748 Hz 5 815 Hz 6 715 Hz t Key L is the length in millimetres (mm); b is the width in millimetres (mm); t is the thickness in millimetres (mm); f is the fundamental flexural resonant frequency in Hertz (Hz); f f is the fundamental torsional resonant frequency in Hertz (Hz). t

4.2.6 Frequency counter

The frequency counter, preferably digital, shall be able to measure frequencies to within ±1 Hz.

4.2.7 Specimen suspension means

Any method of specimen support that permits the free vibration of the test piece with no significant effect on the vibration frequencies shall be used. Test pieces are commonly supported either by suspension from threads or wires or on direct contact supports. If the test piece is to be supported from beneath, the support shall be made of rubber, cork or similar material, and shall have a minimum contact area with the test piece. If the test piece is suspended from the driving and detecting transducers, fine thread or metal wires shall be used. The vibrating mass of the suspension system shall be less than 0,1 % of the mass of the test piece. For the electromagnetic or electrostatic method, the mass of any magnetic foil or electrode attached to the test piece shall be negligible compared with the mass of the test piece. NOTE For the electrostatic method it can be necessary to make the support electrically conducting.

4.2.8 Micrometer

A micrometer with a resolution of 0,002 mm or 0,1 % of the specimen, in accordance with ISO 3611, shall be used to measure the thickness, width and diameter of the test piece. Alternative dimension measuring instruments that have a resolution of 0,002 mm or finer may be used.

4.2.9 Vernier calliper

A vernier calliper with a resolution of 0,05 mm or 0,1 % of the specimen, in accordance with ISO 13385-1, shall be used to measure the length of the test piece. Alternative dimension measuring instruments that have a resolution of 0,05 mm or finer may be used.

4.2.10 Balance

A balance with a resolution of 1 mg or 0,1 % of the specimen or finer, shall be used to measure the mass of the test piece.

4.2.11 Oven for drying test pieces at 110 °C ± 10 °C, or other suitable device. 4.2.12 Desiccator for storage of dried test pieces.

PROOF/ÉPREUVE

ISO 17561:2026(en)

4.3 Test pieces

4.3.1 General

This test method is not satisfactory for test pieces that have major discontinuities, such as large cracks (surface or internal) or internal voids.

The test piece shall be a rectangular prism in accordance with 4.3.2.1 and 4.3.3.1, or a circular cross section rod in accordance with 4.3.2.2 and 4.3.3.2.

The maximum grain size, in accordance with ISO13383-1, excluding deliberately added whiskers, shall be less than 10 % of the minimum dimension of the test piece.

The surface of the test piece shall be smooth and flat. The surface shall be finished using a fine grind (400 grit or finer). The machining procedure shall not affect the test results. The edges of the specimen shall not be chamfered. However, if the chipping of the specimen from the edges affects the results, the edges may be chamfered, but the amount of the chamfering shall be as small as possible.

[1] NOTE ASTM C1259, Annex A2 describes how to correct the calculation of Young’s modulus for edge chamfers or radii in rectangular beams.

For the suspension method, the mass of the specimen is, with advantage, at least 5 g in order to assist keeping a suspension system straight.

4.3.2 Flexural resonance
4.3.2.1 Rectangular prism

The test piece shall have a length (L) greater than 40 mm and a ratio of length to thickness (t) greater than 10 and preferably greater than 20. The ratio of length to width (b) shall be greater than or equal to 10. The dimensions of the test piece shall be such as to have a fundamental flexural resonant frequency in the range 100 Hz to 20 kHz.

[2] NOTE For convenience, a flexural test piece as defined in ISO 14704 can be used, provided that the ends of the bar are machined square and parallel, subject to the allowable frequency range above. If the moduli of the test material are high (E > 200 GPa), or when the available oscillator power is marginal, it is recommended that L/t >> 10 and that 10 > b/t > 2,5. It is also recommended that b/t is > 1,1 or < 0,9 to avoid confusion of different vibration modes.

The parallelism of the upper and lower surfaces perpendicular to the direction of flexural vibration shall be better than t/100, of the sides parallel to the direction of vibration, better than b/100, and of the ends of the test piece, better than L/200.

4.3.2.2 Cylindrical rod

The test piece shall have a length (L) greater than 40 mm and a ratio of length to diameter (d) greater than 10 and preferably greater than 20.

The diameter of the test piece shall be constant to within d/100 and the ends shall be flat and parallel to better than L/200 PROOF/ÉPREUVE

ISO 17561:2026(en)

4.3.3 Torsional resonance
4.3.3.1 Rectangular prism

The test piece shall have a length (L) greater than 40 mm and a ratio of length to thickness (t) greater than 10, and preferably greater than 20. The ratio of width (b) to thickness (t) shall be in the range of 1,5 to 10 (5 is recommended).

The parallelism of the upper and lower surfaces perpendicular to the direction of flexural vibration shall be better than t/100, of the sides parallel to the direction of vibration, better than b/100, and of the ends of the test piece better than L/200.

4.3.3.2 Cylindrical rod

The test piece shall have a length (L) greater than 40 mm and a ratio of length to diameter (d) greater than 10 and preferably greater than 20.

The diameter of the test piece shall be constant to within d/100 and the ends shall be flat and parallel to better than L/200

4.3.4 Number of test pieces

The minimum number of test pieces prepared shall be three.

4.4 Test procedure

4.4.1 Measurement of the size and the mass

Dry the test pieces at 110 °C ± 10 °C until the mass is constant and cool in the desiccator. Weigh each test piece to the nearest 1 mg or 0,1 % (whichever is greater). Measure the cross-sectional dimensions of each test piece (i.e. the thickness and the width, or the diameter) at three positions along its length to the nearest 0,002 mm or 0,1 % (whichever is greater) using the micrometer (4.2.8) and calculate the mean values. Measure the length with the vernier calliper (4.2.9) to the nearest 0,05 mm or 0,1 % (whichever is greater).

4.4.2 Positioning of the test pieces

Position each test piece in turn properly. If the fundamental mode of the flexural resonance is measured, the vibration nodes appear at a distance of 0,224 of the total length from each end. If the specimen is suspended by threads or wires that will be used to drive and detect vibration, position the threads outside the nodal points, as shown in Figure 1 (distance of 0,2 of the length from each end is recommended). If the specimen is to be supported from below, position two supports at the nodal points, as shown in Figure 2. If the fundamental mode of the torsional resonance is measured, the vibration nodes appear as shown in Figure 3. If the specimen is supported from below, position one support at the centre of the specimen, as shown in Figure 3. If the specimen is suspended by threads, position the supports at diagonally opposed corners of the specimen, as shown in Figure 4. The suspending devices shall permit the free vibration of the test piece. Cotton thread is recommended for suspending the specimen. Cork or rubber is recommended for supporting the specimen.

It is recommended that external noise is excluded as far as is practical to avoid extraneous excitations of the test piece. For very small test pieces, the use of a vacuum envelope for the apparatus is recommended. PROOF/ÉPREUVE

ISO 17561:2026(en) Key 1 driving 2 detecting 3 nodal Figure 3 — Nodes and direct contact support on the fundamental torsional resonance Key 1 driving 2 detecting Figure 4 — Suspension for the fundamental torsional resonance

4.4.3 Measurement of resonant frequency

Activate the equipment so that the power adequate to excite the specimen is delivered to the driving transducer. Set the gain of the detector circuit high enough to detect vibration in the specimen and to display it on the oscilloscope screen with sufficient amplitude to accurately measure the frequency at which the signal amplitude is maximized. Adjust the oscilloscope so that a sharply defined horizontal baseline exists when the test piece is not excited. Scan frequencies with the audio oscillator until test piece resonance (flexural or torsional) is indicated by a sinusoidal pattern of maximum amplitude on the oscilloscope or by a single closed loop Lissajous pattern. It is recommended that the frequency scan starts at a low frequency and then increases.

PROOF/ÉPREUVE

...

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 3.5 flexural vibration
  • 4 Method A: Sonic Resonance
  • 4.1 Principle
  • 4.2 Apparatus
  • 4.3 Test pieces
  • 4.4 Test procedure
  • 4.5 Calculations
  • 4.6 Measurement uncertainty
  • 5 Method B: Impulse excitation method
  • 5.1 Principle
  • 5.2 Apparatus
  • 5.3 Test pieces
  • 5.4 Procedure
  • 5.5 Calculations
  • 5.6 Measurement uncertainty
  • 6 Report
  • 6.1 General
  • 6.2 Method A
  • 6.3 Method B
  • Annex A
  • Annex B
  • Bibliography

1 Scope

This document specifies test methods for determining the dynamic elastic moduli, specifically Young’s modulus, shear modulus and Poisson’s ratio, of fine ceramics at room temperature. This standarddocument specifies two alternative methods:

a) a) method A - determination of moduli by forced sonic resonance of a slender beam; b) b) method b - determination of moduli from the fundamental natural frequencies of a struck slender beam (impulse excitation technique - IET).

[3] Both test methods assume the use of test pieces of homogeneous, isotropic and linear elastic materials .[3]. NOTE 1 Not all ceramic materials are equally and linearly elastic in tension and compression, such as some porous materials, and some piezoelectric materials.

NOTE 2 At high porosity levels, these methods can become inappropriate. NOTE 3 The merits of the two methods described in the present document have been addressed in a European roundrobin comparing four methods for the determination of the elastic moduli of monolithic ceramics at room temperature. The results of this exercise are provided in the informative Annex BAnnex B (see also reference [3]).[3]).

2 Normative references

The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. <std>ISO 3611, Geometrical product specifications (GPS) — Dimensional measuring equipment — Design and metrological characteristics of micrometers for external measurements</std> <std>ISO 13383-ISO 13383-1, Fine ceramics (advanced ceramics, advanced technical ceramics) — Microstructural characterization — Part 1: Determination of grain size and size distribution</std> <std>ISO 13385-ISO 13385-1, Geometrical product specifications (GPS) — Dimensional measuring equipment - Part 1: Design and metrological characteristics of callipers</std> <std>ISO/IEC 17025, General requirements for the competence of testing and calibration laboratories</std> ISO/IEC 17025, General requirements for the competence of testing and calibration laboratories

3 Terms and definitions

For the purposes of this document, the following terms and definitions apply.

ISO/PRF 17561:2026(en) ISO and IEC maintain terminology databases for use in standardization at the following addresses:

  • — ISO Online browsing platform: available at https://www.iso.org/obphttps://www.iso.org/obp
  • — IEC Electropedia: available at https://www.electropedia.org/https://www.electropedia.org/ 3.1 3.1 dynamic elastic moduli elastic moduli determined non-quasistatically, i.e. under quasi-adiabatic conditions, such as in the sonic resonance and impulse excitation methods 3.2 3.2 Young’s modulus E stress required in a material to produce unit strain in uniaxial extension or compression E =/

𝐸 = 𝜎/𝜀 where E is Young’s modulus in pascals (Pa); σ is the tension or compression stress in pascals (Pa); ε is the tension or compression strain.

3.3 3.3 shear modulus G shear stress required in a material to produce unit angular distortion G =/

𝐺 = 𝜏/𝛾 where G is the shear modulus in pascals (Pa); τ is the shear or torsional stress in pascals (Pa); γ is the shear or torsional strain.

3.4 3.4 Poisson's ratio ν ratio of transverse strain to the corresponding axial strain resulting from uniformly distributed axial stress below the proportional limit of the material Note 1 to entry: In isotropic materials, Young’s modulus (E), shear modulus (G) and Poisson's ratio (ν) are related by the following formula:

v=−E /21G

3.5𝑣 = 𝐸/(2𝐺) − 1

ISO/PRF 17561:2026(en)

3.5 flexural vibration

vibration in a flexural mode vibration apparent when the oscillation in a slender beam is in plane normal to the length dimension 3.6 3.6 torsional vibration vibration in a torsional mode vibration apparent when the oscillation in each cross-section plane of a slender bar is such that the plane twists around the length dimension axis 3.7 3.7 resonance state in which, when a slender bar is driven into one of the above modesa flexural or torsional mode of vibration, the imposed frequency is such that the resultant displacements for a given amount of driving force are at a maximum Note 1 to entry: The resonant frequencies are natural vibration frequencies which are determined by the elastic modulus, mass and dimensions of the test piece.

3.8 3.8 fundamental frequency lowest frequency of a periodic waveform 3.9 3.9 node location in a vibrating shape where the displacement is zero for a given frequency of vibration Note 1 to entry: For the fundamental flexural resonance in a slender beam, the nodes are located at 0,224 L from each end, where L is the length of the bar.

4 Method A: Sonic Resonance

4.1 Principle

This test method measures the flexural or torsional frequencies of test specimens of a slender rectangular prism or cylindrical rod by exciting them at continuously variable frequencies. Mechanical excitation of the specimens is provided through the use of a transducer that transforms a cyclic electrical signal into a cyclic mechanical force on the test piece. A second transducer senses the resulting mechanical vibrations of the test piece and transforms them into an electrical signal. The amplitude and the frequency of the signal are measured by an oscilloscope or other means to detect resonance. The peak response is obtained at the resonant frequency. The fundamental resonant frequencies, dimensions and mass of the specimen are used to calculate the dynamic elastic moduli. The Young’s modulus is determined from the flexural resonance frequency, and the shear modulus is determined from the torsional resonance frequency, together with the test piece dimensions and mass. Poisson's ratio is determined from the Young’s modulus and the shear modulus.

4.2 Apparatus

4.2.1 General

There are various techniques that may be used to determine the resonant frequency of the test piece. The test piece can be excited by direct mechanical contact of a vibrator, or it can be suspended by a wire from a vibrator. It can be driven electromagnetically by attaching thin foils of magnetic material to one surface, or electrostatically by attaching an electrode to, or painting a conducting film of metal or graphite on, one surface.

ISO/PRF 17561:2026(en) One example of the test apparatus is shown in Figure 1.Figure 1 . The driving circuit consists of an oscillator, an amplifier, a driver and a frequency counter. The detecting circuit consists of a detector, an amplifier and an oscilloscope. Figure 1Figure 1 shows the suspension style of the apparatus. The direct contact support style of the test apparatus, shown in Figure 2,Figure 2 , is also possible. It consists of a variable-frequency audio oscillator, used to generate a sinusoidal voltage, and a power amplifier and suitable transducer to convert the electrical signal to a mechanical driving vibration. A frequency meter (preferably digital) monitors the audio oscillator output to provide accurate frequency determination. A suitable suspension coupling system supports the test piece. A transducer detector acts to detect mechanical vibration in the specimen and to convert it into an electrical signal which is passed through an amplifier and displayed on an indicating meter. The meter may be a voltmeter, a microammeter or an oscilloscope. An oscilloscope is recommended because it enables the operator to positively identify resonances, including higher order harmonics, by Lissajous figure analysis, which is a superposition of two perpendicular harmonics. If a Lissajous figure is desired, the output of the oscillator is also coupled to the horizontal plates of the oscilloscope. 17561_ed3fig1.EPS

Key 1 frequency counter 2 oscillator 3 amplifier 4 driver 5 oscilloscope 6 detector 7 suspending string Figure 1 — Example of the test apparatus and the suspension for fundamental flexural resonance

ISO/PRF 17561:2026(en) 17561_ed3fig2.EPS

Key 1 driving 2 detecting 3 flexural Figure 2 — Example of the direct contact support of the test piece for fundamental flexural resonance 4.2.2 4.2.2 Oscillator The oscillator shall be able to vary the frequency from 100 Hz to at least 30 kHz, with a frequency resolution of 1 Hz and a maximum frequency drift of 1 Hz/min.

4.2.3 4.2.3 Amplifier The audio amplifier shall have a power output sufficient to ensure that the type of transducer used can excite any specimen, the mass of which falls within a specified range. A power amplifier in the detector circuit shall be impedance-matched with the type of detector transducer selected and shall serve as a prescope amplifier. 4.2.4 4.2.4 Driver The driver shall be able to convert electrical vibration to mechanical vibration. The frequency response of the driver transducer across the frequency range of interest shall have at least a 6,5 kHz bandwidth before −3 dB power loss occurs.

NOTE For flexibility in testing, the bandwidth can, with advantage, be at least as large as the frequency range given in Table 1.Table 1 .

4.2.5 4.2.5 Detector The detector shall generate a voltage proportional to the amplitude, velocity or acceleration of the mechanical vibration of the specimen. The frequency response of the detector across the frequency range of interest shall have at least a 6,5 kHz bandwidth before a −3 dB power loss occurs. NOTE For flexibility in testing, the bandwidth can, with advantage, be at least as large as the frequency range given in Table 1.Table 1 .

ISO/PRF 17561:2026(en) Table 1 — Examples of the test piece size and calculated resonant frequencies

When the density = 3 g/cm E = 200 GPa E = 300 GPa E = 400 GPa L × b × t ν = 0,25 ν = 0,25 ν = 0,25 ff = 12 255 Hz 15 010 Hz 17 332 Hz 45 x 4 x 3 ft = 50 756 Hz 62 163 Hz 71 780 Hz f = 4 453 Hz 5 453 Hz 6 297 Hz f 75 × 15 × 3 ft = 12 699 Hz 15 553 Hz 17 959 Hz f = 1 676 Hz 2 053 Hz 2 371 Hz f 100 × 20 × 2 f = 5 014 Hz 6 141 Hz 7 091 Hz t ff = 2 977 Hz 3 646 Hz 4 210 Hz 75 × 20 × 2 f = 6 715 Hz 8 224 Hz 9 496 Hz t

When the density = 6 g/cm E = 200 GPa E = 300 GPa E = 400 GPa L × b × t ν = 0,25 ν = 0,25 ν = 0,25 ff = 8 666 Hz 10 613 Hz 12 255 Hz 45 x 4 x 3 ft = 35 890 Hz 43 956 Hz 50 756 Hz f = 3 148 Hz 3 856 Hz 4 453 Hz f 75 × 15 × 3 ft = 8 979 Hz 10 998 Hz 12 699 Hz f = 1 185 Hz 1 452 Hz 1 676 Hz f 100 × 20 × 2 f = 3 546 Hz 4 342 Hz 5 014 Hz t ff = 2 105 Hz 2 578 Hz 2 977 Hz 75 × 20 × 2 f = 4 748 Hz 5 815 Hz 6 715 Hz t Key L is the length in millimetres (mm); b is the width in millimetres (mm); t is the thickness in millimetres (mm); ff is the fundamental flexural resonant frequency in Hertz (Hz); f is the fundamental torsional resonant frequency in Hertz (Hz). t 4.2.6 4.2.6 Frequency counter The frequency counter, preferably digital, shall be able to measure frequencies to within ±1 Hz. 4.2.7 4.2.7 Specimen suspension means Any method of specimen support that permits the free vibration of the test piece with no significant effect on the vibration frequencies shall be used. Test pieces are commonly supported either by suspension from threads or wires or on direct contact supports. If the test piece is to be supported from beneath, the support shall be made of rubber, cork or similar material, and shall have a minimum contact area with the test piece. If the test piece is suspended from the driving and detecting transducers, fine thread or metal wires shall be used. The vibrating mass of the suspension system shall be less than 0,1 % of the mass of the test piece. For the electromagnetic or electrostatic method, the mass of any magnetic foil or electrode attached to the test piece shall be negligible compared with the mass of the test piece. NOTE For the electrostatic method it can be necessary to make the support electrically conducting. 4.2.8 4.2.8 Micrometer

ISO/PRF 17561:2026(en) A micrometer with a resolution of 0,002 mm or 0,1 % of the specimen, in accordance with ISO 3611, shall be used to measure the thickness, width and diameter of the test piece. Alternative dimension measuring instruments that have a resolution of 0,002 mm or finer may be used. 4.2.9 4.2.9 Vernier calliper A vernier calliper with a resolution of 0,05 mm or 0,1 % of the specimen, in accordance with ISO 13385-1, shall be used to measure the length of the test piece. Alternative dimension measuring instruments that have a resolution of 0,05 mm or finer may be used.

4.2.10 4.2.10 Balance A balance with a resolution of 1 mg or 0,1 % of the specimen or finer, shall be used to measure the mass of the test piece.

4.2.11 4.2.11 Oven for drying test pieces at 110 °C ± 10 °C, or other suitable device. 4.2.12 4.2.12 Desiccator for storage of dried test pieces.

4.3 Test pieces

4.3.1 General

This test method is not satisfactory for test pieces that have major discontinuities, such as large cracks (surface or internal) or internal voids.

The test piece shall be a rectangular prism in accordance with 4.3.2.14.3.2.1 and 4.3.3.1,4.3.3.1, or a circular cross section rod in accordance with 4.3.2.24.3.2.2 and 4.3.3.2.4.3.3.2. The maximum grain size, in accordance with ISO13383-1, excluding deliberately added whiskers, shall be less than 10 % of the minimum dimension of the test piece.

The surface of the test piece shall be smooth and flat. The surface shall be finished using a fine grind (400 grit or finer). The machining procedure shall not affect the test results. The edges of the specimen shall not be chamfered. However, if the chipping of the specimen from the edges affects the results, the edges may be chamfered, but the amount of the chamfering shall be as small as possible. [1] NOTE ASTM C1259, Annex A2 [1] describes how to correct the calculation of Young’s modulus for edge chamfers or radii in rectangular beams.

For the suspension method, the mass of the specimen is, with advantage, at least 5 g in order to assist keeping a suspension system straight.

4.3.2 Flexural resonance
4.3.2.1 Rectangular prism

The test piece shall have a length (L) greater than 40 mm and a ratio of length to thickness (t) greater than 10 and preferably greater than 20. The ratio of length to width (b) shall be greater than or equal to 10. The dimensions of the test piece shall be such as to have a fundamental flexural resonant frequency in the range 100 Hz to 20 kHz.

[2] NOTE For convenience, a flexural test piece as defined in ISO 14704 [2] can be used, provided that the ends of the bar are machined square and parallel, subject to the allowable frequency range above.

ISO/PRF 17561:2026(en) If the moduli of the test material are high (E > 200 GPa), or when the available oscillator power is marginal, it is recommended that L/t >> 10 and that 10 > b/t > 2,5. It is also recommended that b/t is > 1,1 or < 0,9 to avoid confusion of different vibration modes.

The parallelism of the upper and lower surfaces perpendicular to the direction of flexural vibration shall be better than t/100, of the sides parallel to the direction of vibration, better than b/100, and of the ends of the test piece, better than L/200.

4.3.2.2 Cylindrical rod

The test piece shall have a length (L) greater than 40 mm and a ratio of length to diameter (d) greater than 10 and preferably greater than 20.

The diameter of the test piece shall be constant to within d/100 and the ends shall be flat and parallel to better than L/200

4.3.3 Torsional resonance
4.3.3.1 Rectangular prism

The test piece shall have a length (L) greater than 40 mm and a ratio of length to thickness (t) greater than 10, and preferably greater than 20. The ratio of width (b) to thickness (t) shall be in the range of 1,5 to 10 (5 is recommended).

The parallelism of the upper and lower surfaces perpendicular to the direction of flexural vibration shall be better than t/100, of the sides parallel to the direction of vibration, better than b/100, and of the ends of the test piece better than L/200.

4.3.3.2 Cylindrical rod

The test piece shall have a length (L) greater than 40 mm and a ratio of length to diameter (d) greater than 10 and preferably greater than 20.

The diameter of the test piece shall be constant to within d/100 and the ends shall be flat and parallel to better than L/200

4.3.4 Number of test pieces

The minimum number of test pieces prepared shall be three.

4.4 Test procedure

4.4.1 Measurement of the size and the mass

Dry the test pieces at 110 °C ± 10 °C until the mass is constant and cool in the desiccator. Weigh each test piece to the nearest 1 mg or 0,1 % (whichever is greater). Measure the cross-sectional dimensions of each test piece (i.e. the thickness and the width, or the diameter) at three positions along its length to the nearest 0,002 mm or 0,1 % (whichever is greater) using the micrometer (4.2.8)(4.2.8) and calculate the mean values. Measure the length with the vernier calliper (4.2.9)(4.2.9) to the nearest 0,05 mm or 0,1 % (whichever is greater).

4.4.2 Positioning of the test pieces

Position each test piece in turn properly. If the fundamental mode of the flexural resonance is measured, the vibration nodes appear at a distance of 0,224 of the total length from each end. If the specimen is suspended

ISO/PRF 17561:2026(en) by threads or wires that will be used to drive and detect vibration, position the threads outside the nodal points, as shown in Figure 1Figure 1 (distance of 0,2 of the length from each end is recommended). If the specimen is to be supported from below, position two supports at the nodal points, as shown in Figure 2.Figure 2 . If the fundamental mode of the torsional resonance is measured, the vibration nodes appear as shown in Figure 3.Figure 3 . If the specimen is supported from below, position one support at the centre of the specimen, as shown in Figure 3.Figure 3 . If the specimen is suspended by threads, position the supports at diagonally opposed corners of the specimen, as shown in Figure 4.Figure 4 . The suspending devices shall permit the free vibration of the test piece.

Cotton thread is recommended for suspending the specimen. Cork or rubber is recommended for supporting the specimen.

It is recommended that external noise is excluded as far as is practical to avoid extraneous excitations of the test piece. For very small test pieces, the use of a vacuum envelope for the apparatus is recommended. 17561_ed3fig3.EPS

Key 1 driving 2 detecting 3 nodal Figure 3 — Nodes and direct contact support on the fundamental torsional resonance

ISO/PRF 17561:2026(en) 17561_ed3fig4.EPS

Key 1 driving 2 detecting Figure 4 — Suspension for the fundamental torsional resonance

...